Product and Applications Description

Similar documents
The universal input/output device is a DIN rail mounted device. It is connected to the EIB via a bus connecting terminal.

Wireless multizone receiver RDE-MZ6

Time Switch, 2-channel, MDRC SW/S 2.5, GH Q R0001

Instabus Radio Control Converter Installation Instructions

Unidirectional Gateway EnOcean - KNX/BUS

Universal Radio Cord Dimmer Order No.: Function

WAGO Application: Plastic Technology Center (SKZ) in Würzburg, Germany

1. Function. Universal dimming actuator REG-K/2x230/ 300 W. Universal dimming actuator REG-K/230/ 500 W. Universal dimming actuator REG-K/230/ 1000 W

Technical data: Instabus EIB supply Voltage: YY 6 x 0.6 mm; red: bus (+) / black: bus (-)

17/2 Introduction. Display, Operation 17/6 Introduction 17/7 Pushbuttons 17/10 Pushbutton accessories 17/11 Remote controls

Radio motion detector comfort 1.1 m/2.2 m quicklink Order number

14/2 14/5 14/9 14/11 DELTA 14/12 DELTA

Wireless Receiver E28Q Mounting and Operating Instructions (Original operating instructions)

KNX Powerline PL 110. KNX Association

Rev ABB i-bus KNX 6151/11 U-500. Power and productivity for a better world TM

Operating Instructions

Width (W): 44 mm. bus connecting and branching terminal External supply --- Inputs: Number: up to 2 (depending on parameterization: channel 1 to 2)

10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units

AT-SL-ADR & AT-SL-ADR/SA

AT-SL-DDR & AT-SL-DDR-SA

Subject to changes 11/2003 Page 1/7

gesis EIB V Manual Installation system for European Installation Bus Products and Objects description

AT-SL-DDR & AT-SL-DDR-SA

JUMO Wtrans Receiver Universal Receiver for JUMO Wireless Measuring Probes

Transformers, Power Supply Units and Socket Outlets

Manual. Radio Control Central Unit

1 Safety instructions. 2 Device components. Radio bus system. Radio socket outlet adapter for dimming Order No. : Operating instructions

Wireless Room Thermostat Installation and Operation Y6630D1007

KNX radio wall-transmitter 1gang/2gang flat quicklink Order no.: 8565 x2 xx

Radio bus system Radio-universal dimming actuator, 1-gang. 1 Safety instructions. 2 Device components. Order-No. : Operating instructions

Wireless wall transmitter, 1-gang with inscription space, Wireless wall transmitter, 3-gang with inscription space

Product Manual. ABB i-bus EIB / KNX. Universal Interface US/U Intelligent Installation Systems

Electronic timer CT-AWS Impulse-OFF with 1 c/o contact Data sheet

instabus EIB product documentation

ProLine P Precise Temperature Measurement at High Voltage Potentials up to 6.6 kv

Solid-State Relays Zero-point switching, without heatsink


EC5401B. B-Tronic EasyControl. Assembly and Operating Instructions. Wall/hand-held transmitter, 1-channel, bidirectional

Radio Management. Radio Management Controller. Manual. Art.-no.: FMC 1000 GB J:

JUMO Wtrans Receiver with Wireless Data Transmission

For controlling 4 independent shutter or sunblind drives via ABB i-bus including the functions Up/Down, Step/Stop.

Operating Instruction

MINI-PS AC/24DC/1.3

PHOENIX CONTACT

DATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection

DB 112 B. Double Sheet Testing Unit TECHNICAL DESCRIPTION. en / We reserve the right to. make technical changes

STC-KNX (32-channel AP)

Technical data lumina MS4/RC

Electronic timer CT-ERS ON-delayed with 2 c/o contacts Data sheet

KNX ENO 634 (32-channel AP)

Shutter Actuator with Manual Operation, 4-fold, 230 V AC, MDRC JA/S M, GH Q R0111. ABB i-bus EIB / KNX

DATASHEET - ETR4-51-A. Delivery program. Technical data General. Timing relay, star-delta, 50 ms, 1W, 3-60s, VAC/DC

Type CP-S, CP-C & CP-A Switch mode

No-wear isolation of potentials in terminal block design

INSTRUCTION MANUAL. IBRit - rf1 - usb PC - Station for wireless Data transmission. M e s s t e c h n i k. Messtechnik GmbH & Co.

Flexible AC current probes

02/11/2015

Pulse Scaler for DIN Rail Attachment

Analogue temperature controllers

RISH Ducer TV 808, 2 channels Isolating amplifier unipolar / bipolar

KNX manual 1-channel flush-mounted switch actuator SU 1

Precipitation Monitor ,

Electronic circuit breaker ESS30-Sxxx-DC24V

TRANSDUCER of TEMPERATURE and STANDARD SIGNALS P20 type

Mounting instruction and operating manual. Access Point (UK) HmIP-HAP-UK

SensyTemp TSBA (BA R) Resistance thermometer for building automation, machine construction and environmental engineering

Electronic timer CT-TGD.22

User Manual March 2008

IsoTrans 41. The load capability of the 20 ma source is limited and therefore requires efficient use of the load voltage.

Electronic Circuit Breaker with reset input ESS20-1..

Astra-R Kit Wireless Alarm System Operation Manual

Electronic Circuit Breaker ESS20-0..

Air damper actuators. OpenAir GSD...1A. Electric motor-driven rotary actuators for open-close, three-position and modulating control

Operating instructions II / 2004

PART NUMBERING SYSTEM

02/11/2015

NSD Safety Mat Controller Modules Both Modules are compliant to OSHA & ANSI Standards - EN ISO EN EN 81-1 EN NSD VDC

LH630 LH635 LH1035. Operating Instructions Mode d emploi Bedienungsanleitung Istruzioni per il funzionamento Instrucciones de Funcionamiento

Digital Input Output Module 24 V for Ex n Zone 2 Series 9472/35

Coupling Relays and Converters

HUMIDITY/TEMP. CONTROLLER/MONITOR

1 Safety instructions. 2 Device components. 3 Function. Radio bus system. Radio socket-outlet adapter for switching Order No. :

B-Tronic EasyControl EC5401B

Operating instructions Flat-Type Wall-Mounted Radio Control

INSTABUS RADIO GATEWAY

Portable equipment for insulation fault location for unearthed and earthed systems (IT and TN systems) to be used in conjunction with or without an

Configured air damper actuators 6FU11xx-xDxxx-xxxx

Radio controlled home automation

Technical Information Barrier RB223

Precipition Sensor with analogue Intensity Output ,

PHOENIX CONTACT

Series 1. Remote. Multiple Mode Remote Controlled Electro Stimulation Control Unit. User Manual

luxcontrol lighting control system basicdim basicdim ILD 16DPI 69f Compact control module with ambient light sensor and motion sensor

DT1100 xx xx xx PS. Isolators, Isolator / Power Supplies. Operating Instructions

GESTRA Steam Systems LRS English. Installation & Operating Instructions Conductivity Switch LRS 1-50

5.5 SLG 75. Read/Write Devices Read/Write Antennas

3RF A A 0 2. Switching function. Control voltage Operating voltage with heat sink 10 = 10.5 A. A = Zero-point switching

PHASED OUT. LED Driver Compact fixed output. Driver LCI 10W 350mA 900mA TOP C TOP series

Rotary actuators for ball valves

Air damper actuators. OpenAir GDB..1E. Electronic motor driven actuators for open-close, three-position and modulating control

Transcription:

Product and pplications Description Diagram The transmitter 230V wave UP 110 (Diagram ) is a flushmounted device with radio communication for the wireless operation of room functions. It is possible to connect a 1- fold or 2-fold instabus push button (to be ordered separately) or a motion detector (in development) via a 10-pin plug-in connector. Via the push button rocker(s) of a plugin instabus push button, it is possible to operate other radio-controlled actuators and to store and retrieve scenes in the actuators via remote control. The transmitter 230V wave is connected to the 230V network and supplied with current via an integrated power supply unit. When the operator interface is removed, the commissioning of the transmitter 230V wave is carried out without any special tools via the six DIL switches located at the front of the device (Easy mode Push utton: EP). There are two different operation modes for the transmitter 230V wave: Normal function With an instabus push button: operation of other actuators that are linked via radio, storing and retrieving of scenes With a motion detector: reporting of detected movements to other devices that are linked via radio Special function Establishing connections to other radio-controlled components Deleting connections to other radio-controlled components Operation The 1-fold or 2-fold instabus push button placed on the transmitter 230V wave can be operated at the TOP or OTTOM. The exact operational functionality depends on the devices connected via radio control: switching, dimming, shutter control or scene function. Switching (ctions shorter than 0.4s): TOP In connection with a switch actuator: ON; in connection with a dimmer: switching ON with dimming to the saved memory value OTTOM OFF Dimming (ctions longer than 0.4s): TOP Dimming RIGHTER up to max. light intensity OTTOM Dimming DRKER down to min. light intensity Shutter STEP command (ctions shorter than 0.4s): TOP STOP/OPEN slats (by 1 step) OTTOM STOP/CLOSE slats (by 1 step) Shutter UP/DOWN command (ctions longer than 0.4s): TOP UP command OTTOM DOWN command Scene function: Preselected states for the lighting (ON or OFF or any brightness value) and the shutters (UP or DOWN) can be saved in a scene and reset via a push button action. Up to four scenes can be saved and retrieved with the transmitter 230V wave. If a 1-fold instabus push button is used, scenes 1 and 2 are operated via the rocker. If a 2- fold instabus push button is used, scenes 1 and 2 are operated via the left rocker and scenes 3 and 4 are operated via the right rocker. efore saving a scene, each switch, dimmer and shutter control insert sys or radio-controlled actuator that is linked via radio must be set to the state to be stored: Switch actuator: ON or OFF Dimmer: Desired light intensity value Shutter: TOP or OTTOM (limit position) a) Saving scenes (ctions longer than 3s): When saving a scene, each connected actuator saves the current state under the activated scene number. TOP Saves scene 1 (or scene 3 when operating OTTOM Saves scene 2 (or scene 4 when operating b) Retrieving scenes (ctions shorter than 0.4s): When retrieving a scene, each connected actuator is set to the state that has been stored under this scene number. TOP Retrieves scene 1 (or scene 3 when operating Siemens G wave UP 110, 6 pages Technical Manual utomation and Drives Group Electrical Installation Technology Siemens G 2005 Update: http://www.siemens.de/gamma P.O. ox 10 09 53, D-93009 Regensburg 2.20.1.6/1

OTTOM Retrieves scene 2 (or scene 4 when operating CE norm complies with the EMC regulations (residential buildings), low voltage regulations and R&TTE regulations: Technical Specifications Frequency band 868 MHz (transmission is not susceptible to interference; frequency band reserved for system and security applications) Range of radio control approx. 100 m (applying to free field applications) Power supply via the 230V mains connection, rated voltage: C 230V, 50Hz Connections 2 screw terminals for mains connection; Insulation strip length: approx. 5 mm The following conductors are permitted per screw terminal: - two solid conductors 0.5 to 1.5 mm² - one solid or finely-stranded conductor 0.5 to 2.5 mm² 10-pole socket connector for the connection of a 1-fold or 2-fold instabus push button Mechanical specifications Housing: plastic Dimensions: Spacer units: 71 x 71mm - Mounting depth: 32 mm Weight: approx. 65 g Fire load: approx. 1000 kj Mounting: inserted in box mounts according to DIN 49073-1, 60 mm, min. depth 40 mm. Electrical safety Pollution degree (acc. to IEC 60664-1): 2 Protection (acc. to EN 60529): IP 20 Overvoltage category (acc. to IEC 60664-1): III Device complies with EN 60669-2-1 Electromagnetic compatibility complies with EN 300-220, EN 301-489, EN 60669-2-1 Environmental specifications Climatic conditions: EN 50090-2-2 mbient operating temperature: - 5... + 45 C Storage temperature: - 25... + 70 C Relative humidity (non-condensing): 5% to 93% - stan- Certification VDE certificate in preparation, complies with dard radio frequency rf easy mode push button EP The CE declaration can be inspected at: SIEMENS G Siemensstraße 10 93055 Regensburg Installations Instructions Caution: The installation of the device into metal walls has to be avoided since this considerably reduces the range of radio control. Occasionally the transmission range may be influenced by structural conditions (e.g. reinforced concrete) or electric / electronic sources of interference. minimum distance of 1 m must be maintained between the transmitter and the relevant receivers. Though the radio transmission is carried out in the safe 868 MHz range, disruptions to the radio transmission cannot be excluded. The used radio transmission is not suitable for security applications. V DNGER The device may be used for interior installations and in dry rooms only. The device must be mounted and commissioned by an authorised electrician. The device must not be opened. The device may be mounted in switch and socket combination box mounts provided that only VDE-certified devices are used. The prevailing safety and accident regulations must be observed. Technical Manual wave UP 110, 6 pages Siemens G utomation and Drives Group Update: http://www.siemens.de/gamma Siemens G 2005 Electrical Installation Technology P.O. ox 10 09 53, D-93009 Regensburg 2.20.1.6/2

Mounting The transmitter 230V wave is connected to the mains cable (L and N conductor) (Diagram ) and inserted in a boxmount (Ø 60 mm and 40 mm depth) using screw or claw fixing. 1-fold or 2-fold instabus push button or a motion detector with the relevant frame (to be ordered separately) is placed on the transmitter 230V wave with guide and mounting clamps (Diagram C). C 230 V N L C1 Installation box (60 mm Ø, acc. to DIN 49073-1) C2 Transmitter 230V wave UP 110 C3 Mounting claws C4 Mounting slots for screw fixing C5 Cable for mains connection C6 10-pole socket connector C7 Mounting screws C8 Frame C9 instabus push button Location and Function of the Display and Operating Elements D2 D1 SIEMENS instabus rf EP Wandsender 230V wave UP 110 Transmitter 230V wave UP 110 L N Un ~ 230V/50Hz Made in Germany 0125! Diagram D3 Diagram D C2 C4 C1 D1 D2 D3 DIL switches for selecting the function and connecting the transmitter actuator via radio control LED for displaying the operating state while the connections to other radio control components are established 10-pole socket connector for connecting an instabus push button or a motion detector C5 Dimension Diagram C7 C4 C6 C3 Dimensions in mm 71 32 C8 C9 Diagram C Siemens G wave UP 110, 6 pages Technical Manual utomation and Drives Group Electrical Installation Technology Siemens G 2005 Update: http://www.siemens.de/gamma P.O. ox 10 09 53, D-93009 Regensburg 2.20.1.6/3

Commissioning Note: The transmitter 230V wave must be connected to the 230V cable for the commissioning. The commissioning is carried out without the instabus push button via the 6 DIL switches (D1) located at the front and is indicated via the flashing of the LED (D2) located beside the DIL switches. Function of the DIL switches Diagram E shows the DIL switches in the supplied state. In the lower switch position, a DIL switch is switched off (=OFF) while it is switched on in the upper switch position (=ON). efore connecting a rocker, all the DIL switches should be switched off. Switches K1 to K3 are used for the assignment of the channels. If a 1-fold instabus push button is used or when using a motion detector, DIL switch K1 must be used for commissioning the device. If a 2-fold instabus push button is implemented, DIL switch K1 is required for commissioning the left rocker while DIL switch K2 is required for commissioning the right rocker. DIL switch K3 is only needed during the start of a master reset. K1 1-fold rocker or left rocker, motion detector K2 K3 Right rocker (only to be operated when starting a master reset) The DIL switches F1 to F3 can be used for setting the available functions of switching, switching/ dimming, shutter control or scene function when the transmitter is operated with an push button or for selecting the motion detector function when the transmitter is operated with a motion detector. Diagram E Diagram F shows various switch displays that are used in the subsequent diagrams to explain the commissioning process. Diagram F1 is used to display a triggered action. If the switch is moved from the position to the position, a connection via radio is triggered. Diagram F2 is used to show a position which the relevant DIL switch must occupy. Diagram F3 indicates that the relevant DIL switch must first be switched to the corresponding position according to the required function. F1 F2 F3 Diagram F Diagram G shows which position the function switches F1 to F3 must be switched to in order to preselect a specified function: Diagram G1 Function: Switching Diagram G2 Function: Switching / Dimming Diagram G3 Function: Shutter control Diagram G4 Function: Scene control Diagram G5 Function: Detection of movement fterwards only one of the channel switches K1 or K2 has to be switched to position. Diagram G Connection via radio control: Diagrams H and J indicate the connection of the rocker or the left rocker of a transmitter 230V wave with a single rocker or a twin rocker with a radio-controlled actuator e.g. a switch insert sys with a plug-in push button wave. H1 Transmitter 230V wave UP 110 H2 Push button wave UP 210 H3 Switch insert sys G1 G2 G3 G4 G5 Technical Manual wave UP 110, 6 pages Siemens G utomation and Drives Group Update: http://www.siemens.de/gamma Siemens G 2005 Electrical Installation Technology P.O. ox 10 09 53, D-93009 Regensburg 2.20.1.6/4

1. Radio-controlled actuator: Switch to the special function. (see the commissioning instructions of the radio controlled actuator) 2. Transmitter: Select the required function via the DIL switches F1 and F2 according to diagram G. 3. Transmitter: Trigger a connection telegram via DIL switch K1 (Diagram J). ction: Switch DIL switch K1 to position. The transmitter sends a connection telegram. Display: When K1 has been toggled, the LED of the transmitter wave flashes slowly for approx. 2 seconds (approx. once per second). fter a successful connection, the LED flashes rapidly for approx. 2 seconds (approx. twice per second) and is then extinguished. If a connection cannot be established, the LED is already extinguished after the first period of 2 seconds when it was flashing slowly. The teaching-in process must then be repeated. 4. Transmitter: Reset all the DIL switches to. H1 Diagram H H2 Diagram J H3 Note: If the DIL switches are inadvertently not reset to position after the connection, this is indicated by the LED of the plug-in instabus push button which continuously flashes at a rapid rate. If the transmitter 230V wave should be connected to other radio-controlled actuators, the process described above should be repeated for each actuator. When using a 2-fold push button, if the right rocker should be linked with a radio-controlled actuator, the above procedure should be repeated, whereby the sending of the connection telegram must now be triggered by the toggling of DIL switch K2 (Diagram K). n unlimited number of radio-controlled actuators can be operated remotely via the rockers of a transmitter 230V wave. Switch and dimmer inserts can be operated together. The common operation of dimming and shutter functions is however only possible via scenes. Diagram K Connecting a scene function via radio control: Use of a double instabus push button for control of 4 scenes. 1. Radio controlled actuator: Switch to the special function. 2. Transmitter: Select the scene function via DIL switch F1 and F2. 3. Transmitter: Trigger linking telegram via DIL switch K1 (for the left rocker; Scene 1 and 2). 4. Transmitter: Switch DIL switch K1 back to position. 5. Radio controlled actuator: Switch to the special function again. 6. Transmitter: Trigger linking telegram via DIL switch K2 (for the right rocker; Scene 3 and 4). Repeat steps 1 to 6 for each further radio controlled actuator that is involved in scene function. 7. Transmitter: Switch all DIL switches back to position. Deleting a link via radio control: The deletion of a connection is carried out by a new assignment (see Connection via radio control ). Master reset (Resetting the device to the supplied state, Diagram L) Diagram L Prerequisite: No other radio-controlled device may be switched to the special function. 1. First set the DIL switches F1 to F3 and then the DIL switches K1 to K3 to and wait 10 seconds. 2. Reset all the DIL switches to. Once all the DIL switches have been toggled the LED of the transmitter flashes quicker and quicker and is extinguished after approx. 10 seconds. ll the previously stored associations and connections are then deleted. If one of the DIL switches will be switched to before the deletion of the LED the master reset will be stopped and all previous associations will be retained. Siemens G wave UP 110, 6 pages Technical Manual utomation and Drives Group Electrical Installation Technology Siemens G 2005 Update: http://www.siemens.de/gamma P.O. ox 10 09 53, D-93009 Regensburg 2.20.1.6/5

General Notes Notes The operating instructions must be handed over to the client. ny faulty devices should be returned to the local Siemens office. If you have further questions concerning the product please contact our technical support: +49 (0) 180 50 50-222 " +49 (0) 180 50 50-223! adsupport@siemens.com h www.siemens.de/automation/support-request Technical Manual wave UP 110, 6 pages Siemens G utomation and Drives Group Update: http://www.siemens.de/gamma Siemens G 2005 Electrical Installation Technology P.O. ox 10 09 53, D-93009 Regensburg 2.20.1.6/6