Interactive Catalog Replaces Catalog Pages

CSN Series Closed Loop Current Sensors (Continued) CSLA Series Open Loop Current Sensors CURRENT CURRENT OPTIONS.

High Performance Current Transducer IT 200-S ULTRASTAB = A. ε L

High Performance Current Transducer ITL 900-T = A

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

CYHCS-RC2S Split Core Hall Effect DC Current Sensor

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

ULTRASTAB I U Precision

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

Data Sheet. Hall effect transducers, current and voltage

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

MSA Hall effect transducer

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

AUTOMOTIVE CURRENT TRANSDUCER HC6F600-S

AUTOMOTIVE CURRENT TRANSDUCER HC6F700-S

AUTOMOTIVE CURRENT TRANSDUCER HAH3DR 700-S00

MSA500 - Hall effect transducer

Linear Current Sensor with differential outputs

AUTOMOTIVE CURRENT TRANSDUCER HC2F100-SN CLIPS

AUTOMOTIVE CURRENT SENSOR HC6H500-S. Datasheet

AUTOMOTIVE CURRENT SENSOR HC6H300-S

ULTRASTAB IHF Precision Current Transducer

AUTOMOTIVE CURRENT TRANSDUCER HC6H1000-S

AUTOMOTIVE CURRENT TRANSDUCER HAH3DR 700-S02

DC Current Sensor CYCT04-xnL20

Current Transducer CTSR 1-P = 1A

AUTOMOTIVE CURRENT TRANSDUCER HAH1DR 300-S

DS400ID. Specification highlights Symbol Unit Min Typ Max. Features. Applications: Linearity error maximum 1.5 ppm. MPS for particles accelerators

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

SPECIFICATION Item no.: T60404-N4646-X764

DL2000ID. Specification highlights Symbol Unit Min Typ Max. Features. Applications: 1 ppm linearity. MPS for particles accelerators.

DS2000UBLA-10V. Features. Applications: 20 ppm linearity. MPS for particles accelerators. 15 ppm offset. Gradient amplifiers for MRI devices

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

HC2F100-SN CLIPS AUTOMOTIVE CURRENT TRANSDUCER HC2F100-SN CLIPS. Datasheet

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

DQ600ID. Specification highlights Symbol Unit Min Typ Max. Features. Applications: Linearity error maximum 1 ppm. MPS for particles accelerators

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and secondary circuit.

DS2000ICLA. Specification highlights Symbol Unit Min Typ Max. Features. Applications: 1 ppm linearity. MPS for particles accelerators.

MSV200 - Hall effect transducer

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

Ref: HLSR 10-P/SP3, HLSR 20-P/SP3, HLSR 40-P/SP3, HLSR 50-P/SP3

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary circuit and the secondary circuit.

AUTOMOTIVE CURRENT TRANSDUCER HAB 60-S/SP5

DS200ID-CD100. Specification highlights Symbol Unit Min Typ Max. Features. Applications: Linearity error maximum 2 ppm. MPS for particles accelerators

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

AUTOMOTIVE CURRENT TRANSDUCER DHAB S/15

DC CURRENT SENSOR DC VOLTAGE SENSOR

DM1200ID. Specification highlights Symbol Unit Min Typ Max. Applications: Features. Power measurement and power analysis

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

SPECIFICATION Item no.: T60404-N4646-X762

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HAH1DRW 300-S

When you have completed this exercise, you will be able to relate the gain and bandwidth of an op amp

AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HAH3DR 1100-S07

World-Class Accuracy & Measurement Range (40 Conventional Models)

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

SPECIFICATION Item no.: T60404-N4646-X651

SPECIFICATION Item no.: T60404-N4646-X663

Feed back element in high performance gradient amplifiers Feed back element in precision current regulated power supplies

SPECIFICATION Item no.: T60404-N4646-X400

Ref: HO 50-S/SP33, HO 100-S/SP33, HO 150-S/SP33, HO 200-S/SP33, HO 250-S/SP33

SPECIFICATION Item no.: T60404-N4646-X662

Mors Smitt Industrial Technology. Industrial current & voltage sensors. Hall effect current & voltage sensors

Current transducer FHS 40-P/SP600

Technical catalog. Current sensors Voltage sensors. Contact John G Peck Ltd - jgpl.com

Current transducer FHS 40-P/SP600

For the electronic measurement of current: DC, AC, pulsed..., with galvanic isolation between the primary and the secondary circuit.

AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HAH1DR 200-S

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

Ref: HLSR 10-SM, HLSR 16-SM, HLSR 20-SM, HLSR 32-SM, HLSR 40-SM, HLSR 50-SM

Current Sensor: ACS750xCA-100

I PM. Current Transducer ITZ 5000-SB FLEX ULTRASTAB = 5000 A

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

Technical Catalogue. Current Sensors Voltage Sensors

Ref: HLSR 10-SM/SP33, HLSR 20-SM/SP33, HLSR 32-SM/SP33, HLSR 40-P/SP33, HLSR 50-SM/SP33

DC Current Transducers 4XCT-100-C-HP User s Manual All Rights Reserved CAEN ELS s.r.l. Rev. 1.0 February 2017

Technical catalogue. Current sensors Voltage sensors

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

PRECISION CURRENT TRANSDUCERS. DC Current Transducers CT-100 CT-150. User s Manual. All Rights Reserved CAEN ELS d.o.o. Rev. 1.

Module Input type Ranges TEDS Filters (LP = lowpass, HP = highpass) Piezoresistive bridge ±0.5 to mv/ma 1 ma exc

IMC-Hall Current Sensor

Current Sensor : F02P***S05L

I PN. Ref: HO 50-S, HO 100-S, HO 150-S, HO 200-S, HO 240-S, HO 250-S

DC Current Transducers CT-200 CT-300 CT-400 User s Manual All Rights Reserved CAEN ELS d.o.o. Rev. 1.0 November 2014

HO 50-S/SP30, HO 100-S/SP30, HO 150-S/SP30, HO 200-S/SP30, HO 250-S/SP30 and HO 200-S/SP31

How to Select the Right Current Probe APPLICATION NOTE

AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY DHAB S/124

I P. /dt. di p V S Applications. Standards 1) IEC : 2007; IEC : ) IEC : 2016; IEC : 2017

DS10000ULFS-10V/10kA

SPECIFICATION Item no.: T60404-N4646-X410

AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HAH3DR 800-S03/SP2

Typical Application VCC IP+ ACS755 GND C F 3 R F

Transcription:

Solid State Sensors Closed Loop Sensors CSN Series FEATURES sensing up to 1200 amps Measures AC, DC and impulse currents Lowest cost/performance ratio Rapid response, no overshoot High overload capacity High level of electrical isolation between primary and secondary circuits Small size and weight CLOSED LOOP SENSORS Closed loop current sensors measure AC, DC and impulse currents over 0-25, 0-50, 0-100, 0-600 and 0-1200 Amp ranges. The CSN Series is based on the principles of the Hall effect and the null balance or zero magnetic flux method (feedback system). The magnetic flux in the sensor core is constantly controlled at zero. The amount of current required to balance zero flux is the measure of the primary current flowing through the conductor, multiplied by the ratio of the primary to secondary windings. This closed loop current is the output from the device and presents an image of the primary current reduced by the number of secondary turns at any time. This current can be expressed as a voltage by passing it through a resistor. CATALOG NUMBER SYSTEM PLEASE NOTE: This matrix is intended only to aid you in identifying sensor catalog listings. It is not all-inclusive, and must not be used to form new listings. Example: CSNA111 CSN Closed Loop Sensor Range (Peak/RMS nom.) A ±70 A/50 A rms nom. B ±100 A/50 A rms nom. C ±90 A/50 A rms nom. D ±22 A/15 A rms nom. E ±36 A/25 A rms nom. F ±150 A/100 A rms nom. J ±600 A/300 A rms nom. K ±1200 A/500 A rms nom. L ±600 A/300 A rms nom. M ±1200 A/500 A rms nom. P ±90 A/50 A rms nom. R ±200 A/125 A rms nom. T ±150 A/50 A rms nom. Supply Voltage 1 ±15 V 2 ±13 V 3 ±5V 4 ±12Vto18V 5 ±15Vto24V 6 ±12Vto15V Coil Characteristics 1 1:1000 turns/90 @ 70 C 2 1:2000 turns/160 @ 70 C 3 1:2000 turns/130 @ 70 C 4 1:1000 turns/50 @ 70 C 5 1:1000 turns/110 @ 70 C 6 1:1000 turns/30 @ 70 C 7 1:2000 turns/80 @ 70 C 8 1:2000 turns/25 @ 70 C 9 1:5000 turns/50 @ 85 C Housing Material 1 Polycarbonate/ABS blend PDFINFO p a g e - 0 6 0 60 HoneywellSensingandControl 1-800-537-6945USA 1-815-235-6847 International 1-800-737-3360 Canada

PDFINFO p a g e - 0 6 1 Catalog Listing Range Amps Supply Voltage VDC ±5% Coil Characteristics Turns Resistance s Nom. Resist (@ Inom) CSNA111 ±70 ±15 1000 90 @70 C 50 ma for 50 A 40 to 130 CSNB121 ±100 ±15 2000 160 @70 C 25 ma for 50 A 40 to 270 CSNB131 ±100 ±15 2000 130 @70 C 25 ma for 50 A 40 to 300 CSNE151 ±5-36 ±15 1000 110 @70 C 25 ma for 25 A 100 to 320 CSNE381* ±5-36 ±5V 1000 66 @70 C 25 ma for 25 A 0 to 84 CSNH151* ±4-43 ±15V 1000 110 @70 C 25 ma for 25 A 100 to 320 NOTE: Extended temperature range and potting also available. * Contact the 800 number for more information. SPECIFICATIONS Catalog Listing CSNA111 CSNB121 CSNB131 CSNE151 Offset @ 25 C, ma max. ±0.20 ±0.10 ±0.10 ±0.10 Temperature Drift, 0 to 70 C, ma ±0.35 typ. ±0.20 typ. ±0.20 typ. ±0.17 typ. ±0.60 max. ±0.30 max. ±0.30 max. ±0.60 max. Linearity 0.1% 0.1% 0.1% 0.2% Supply Voltage ±15V ±15V ±15V ±15V Galvanic Isolation @ 50 Hz/1 min. 2.5 kv rms 5 kv rms Accuracy ±0.5% of IN (nominal ) at 25 C Response Time <1 s Bandwidth DC to 150 khz Temperature Operating: 0 to 70 C (32 to 150 F) Storage: 25 to 85 C ( 13 to 185 F) Primary Circuit Connection Thru-hole Thru-hole Thru-hole Invasive on 10 pins Secondary Circuit Connection 3 Pins 3 Pins 3 Pins 3 Pins Drain 10 ma (no load current) + output current (secondary current) In-Out Sense Signal To obtain positive measuring current on O/P terminal, current must flow in direction of arrow Mounting PCB, 3 pins, hole size 0.95 mm PCB, 13 pins PRIMARY PIN CONNECTIONS FOR CSNE151 Primary Output Primary Primary Turns Nom. IDN (A) Max. ID (A) (ma) Resistance (m ) 1 24 36 25 0.3 2 12 18 24 1.1 Primary Pin Connections 3 8 12 24 2.5 4 6 9 24 4.4 5 5 7 25 6.3 WIRING DIAGRAMS CSNA111/CSNB121/CSNB131 CSNE151

PDFINFO p a g e - 0 6 2 CSNE151/CSNE381 CSNH151

PDFINFO p a g e - 0 6 3 Catalog Listings Range Amps Supply Voltage VDC ± 5% Turns Coil Characteristics Resistance s Nom. Resist (@ Inom) CSNJ481 ±600 ±12 to 18 2000 25 @70 C 150 ma for 300 A 0 to 70 CSNJ481-001* ±600 ±12 to 18 2000 25 @70 C 150 ma for 300 A 0 to 70 CSNJ481-002 ±600 ±12 to 18 2000 25 @70 C 150 ma for 300 A 0 to 70 CSNJ481-003* ±600 ±12 to 18 2000 25 @70 C 150 ma for 300 A 0 to 70 CSNK591 ±1200 ±15 to 24 5000 50 @70 C 100 ma for 500 A 0 to 130 CSNK591-001* ±1200 ±15 to 24 5000 50 @70 C 100 ma for 500 A 0 to 130 CSNK591-002 ±1200 ±15 to 24 5000 50 @70 C 100 ma for 500 A 0 to 130 CSNK591-003* ±1200 ±15 to 24 5000 50 @70 C 100 ma for 500 A 0 to 130 *Fitted with busbar SPECIFICATIONS Catalog Listings CSNJ481 CSNJ481-002 CSNK591 CSNK591-002 CSNJ481-001 CSNJ481-003 CSNK591-001 CSNK591-003 Offset @ 25 C, ma max. ±0.30 ±0.30 ±0.20 ±0.20 Temperature Drift, 0 to 70 C, ma ±0.30 typ. ±0.30 typ. ±0.20 typ. ±0.20 typ. ±0.50 max. ±0.50 max. ±0.30 max. ±0.30 max. Linearity ±0.1% ±0.1% ±0.1% ±0.1% Supply Voltage ±12 to ±18V ±12 to ±18V ±15 to ±24V ±15 to ±24V Galvanic Isolation @ 50 Hz/1 min. 7.5 kv rms 7.5 kv rms 6 kv rms 6 kv rms Accuracy ±0.5% of IN (nominal ) at 25 C Response Time Bandwidth <1 s DC to 150 khz Operating Temperature 40 to 85 C 0 to 70 C 40 to 85 C 0 to 70 C ( 40 to 185 F) (32 to 158 F ( 40 to 185 F) (32 to 158 F) Storage Temperature 40 to 90 C 25 to 85 C 40 to 90 C 25 to 85 C ( 40 to 194 F) ( 13 to 85 F ( 40 to 194 F) ( 13 to 85 F) Primary Circuit Connection Thru-hole or busbar Thru-hole or busbar Thru-hole or busbar Thru-hole or busbar Secondary Circuit Connection 3 pins 3 pins 3 pins 3 pins Drain 14 ma (no load current) + output current 22 ma (24 V) + output current In-Out Sense Signal To obtain positive measuring current on O/P terminal, current must flow in direction of arrow Mounting Faston, 3 pins Push-on (spade), 3 terminals WIRING DIAGRAM

CSNK591 PDFINFO p a g e - 0 6 4

PDFINFO p a g e - 0 6 5 Catalog Listings Peak Range Amps Supply Voltage VDC ± 5% Turns Coil Characteristics Resistance s Nom. CSNL181 ±600 ±12 to 18 2000 25 @70 C 150 ma for 300 A 0 to 70 Resist (@ Inom) CSNM191 ±1000 ±12 to 18 5000 50 @70 C 100 ma for 500 A 0 to 120 SPECIFICATIONS Catalog Listings CSNL181 CSNM191 Offset @ 25 C, ma max. ±0.30 ±0.20 Temperature Drift, 0 to 70 C, ma ±0.30 typ. ±0.20 typ. ±0.50 max. ±0.30 max. Linearity ±0.1% ±0.1% Supply Voltage ±12 to ±18V ±12 to ±18V Galvanic Isolation @ 50 Hz/1 min. 7.5 kv rms 7.5 kv rms Accuracy ±0.5% of IN (nominal ) at 25 C Response Time 500 ns <1 s Bandwidth Operating Temperature Storage Temperature DC to 150 khz 40 to 85 C ( 40 to 185 F) 40 to 90 C ( 40 to 194 F) Primary Circuit Connection Thru-hole Thru-hole Secondary Circuit Connection 3 pins 3 pins Drain In-Out Sense Signal Mounting 14 ma (no load current) + output current To obtain positive measuring current on O/P terminal, current must flow in direction of arrow Faston, 3 pins WIRING DIAGRAM

CSNM191 PDFINFO p a g e - 0 6 6

PDFINFO p a g e - 0 6 7 Catalog Listings Peak Range Amps Supply Voltage VDC ± 5% Turns Coil Characteristics Resistance s Nom. Resist (@ Inom) CSNP661 ±90 ±12 to 15 1000 30 @70 C 50 ma for 50 A 50 to 100 CSNT651 ±150 ±12 to 15 2000 100 @70 C 25mAfor50A 40to75 CSNF161 ±150 ±12 to 15 1000 30 @70 C 100 ma for 100 A 10 to 40 CSNF151 ±180 ±12 to 15 2000 100 @70 C 50mAfor100A 10to75 CSNR161 ±200 ±12 to 15 1000 30 @70 C 125 ma for 125 A 30 to 40 CSNR151 ±200 ±12 to 15 2000 100 @70 C 62.5 ma for 125 A 10 to 40 NOTE: Busbar options available. SPECIFICATIONS Catalog Listings CSNP661 CSNT651 CSNF161 CSNF151 CSNR161 CSNR151 Offset @ 25 C, ma max. ±0.20 ±0.10 ±0.20 ±0.10 ±0.20 ±0.10 Temperature Drift, 0 to 70 C, ma ±0.30 typ. ±0.15 typ. ±0.30 typ. ±0.15 typ. ±0.30 typ. ±0.15 typ. ±0.50 max. ±0.25 max. ±0.50 max. ±0.25 max. ±0.60 max. ±0.30 max. Linearity ±0.1% ±0.1% ±0.1% ±0.1% ±0.1% ±0.1% Supply Voltage ±12 to 15V ±12 to 15V ±12 to 15V ±12 to 15V ±12 to 15V ±12 to 15V Galvanic Isolation @ 50 Hz/1 min. 3 kv rms 3 kv rms 3 kv rms 3 kv rms 3 kv rms 3 kv rms Accuracy ±0.5% of IN (nominal ) at 25 C Response Time Bandwidth <500 ns DC to 150 khz Operating Temperature 40 to 85 C( 40 to 185 F) 40 to 85 C ( 40 to 185 F) Storage Temperature 40 to 90 C( 40 to 194 F) 40 to 90 C ( 40 to 194 F) Primary Circuit Connection Secondary Circuit Connection Thru-hole 3 pins Drain 10 ma (no load current) + output current In-Out Sense Signal Mounting 14 ma (no load current) + output current To obtain positive measuring current on O/P terminal, current must flow in direction of arrow 3 pins Pin Style A A B B B B WIRING DIAGRAM

PDFINFO p a g e - 0 6 8