Ametek, Inc. Rotron Technical Products Division. 100 East Erie St., Suite 200 Kent, Ohio User's Guide. Number Revision F

Similar documents
Analog Servo Drive 25A20DD

815-BR SERVO AMPLIFIER FOR BRUSH SERVOMOTORS

B25A20FAC SERIES BRUSHLESS SERVO AMPLIFIERS Model: B25A20FAC 120VAC Single Supply Operation

1525-BRS INFORMATION MANUAL SERV O D YN A M ICS. D y n ad r iv e Ave Crocker Suite 10 Valencia, CA

Analog Servo Drive 30A20AC

DynaDrive INFORMATION MANUAL SDFP(S)

Peak Current. Continuous Current. See Part Numbering Information on last page of datasheet for additional ordering options.

S100A40AC SERIES BRUSHLESS SERVO AMPLIFIERS Model: S100A40AC

Analog Servo Drive. Peak Current 16 A (11.3 A RMS )

Analog Servo Drive. Continuous Current. Features

Analog Servo Drive BD15A8

Brushless DC Motor Controller Specification Assemblies 025F0248

Analog Servo Drive 30A8

Analog Servo Drive 20A20

Analog Servo Drive 30A8

AxCent Servo Drive A25A100

Analog Servo Drive 100A40

FEATURES DESCRIPTION THE OEM ADVANTAGE

SPECIFICATION, CONTROLS AND ACCESSORIES

EC 45 flat with integrated electronics Document ID: en Operating Manual

PRELIMINARY AVB250A060 PRELIMINARY. Servo Drive. Peak Current (10 seconds)

Dynamo Brushless DC Motor and GreenDriveTM Manual

40 Amp Digital Bidirectional PWM Motor Controller with Regenerative Braking BIDIR-340-DR

AxCent Servo Drive A50A100

Thornwood Drive Operating Manual: Two-SCR General Purpose Gate Firing Board FCRO2100 Revision H

Options & Accessories

SPECIFICATION, CONTROLS AND ACCESSORIES

MMP SA-715A SERVO AMPLIFIER

ACE726C. 500KHz, 18V, 2A Synchronous Step-Down Converter. Description. Features. Application

IAP200T120 SixPac 200A / 1200V 3-Phase Bridge IGBT Inverter

AC/DC Power Supply Series APPLICATION NOTE

AC/DC Power Supply Series APPLICATION NOTE

Options & Accessories

MODEL 503 DC BRUSHLESS SERVO AMPLIFIER

AxCent Servo Drive AZBE10A4IC

SixPac Series of SCR AC Controller and DC Converters

BC145 SIGNAL ISOLATOR BOARD

AC/DC Power Supply Series APPLICATION NOTE

SCS Automation and Control Ltd

A7221A DC-DC CONVERTER/BUCK (STEP-DOWN) 600KHz, 16V, 2A SYNCHRONOUS STEP-DOWN CONVERTER

maxon motor maxon motor control 1-Q-EC Amplifier DEC 24/1 Order numbers , , , ,

Analog Servo Drive B25A20

D.C. BRUSHLESS MOTORS DRIVE. BLD07-IT Service Manual

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W

DB Motorized Impeller

This convection-cooled series is designed for use in commercial and industrial environments in temperatures up to 50 C.

MDC VAC Input Brushless Controller. User s Guide. 910 East Orangefair Lane, Anaheim, CA

TENTATIVE PP225D120. POW-R-PAK TM 225A / 1200V Half Bridge IGBT Assembly. Description:

HB-25 Motor Controller (#29144)

SPECIFICATION ARP

Variable Speed Brushed DC Motor Drive

Rotek AS440 compatible VOLTAGE REGULATOR (AVR)

Product Specification

M/V Series Servo Drive AB250A060

LSI/CSI LS7560N LS7561N BRUSHLESS DC MOTOR CONTROLLER

MBC Bipolar Microstep Driver. User s Guide E. Landon Drive Anaheim, CA

7I25 H-BRIDGE MANUAL

Everything s possible. AxCent Panel Mount Drives. for Servo Systems. Hardware. Installation Manual. MNACHWIN-06

10 AMP, 75V, 3 PHASE MOSFET BRUSHLESS MOTOR CONTROLLER

DB Motorized Impeller

DM8010 tm. Hardware Reference Manual. Document Revision B3 May 16, 2018

DESCRIPTION FEATURES APPLICATIONS TYPICAL APPLICATION. 500KHz, 18V, 2A Synchronous Step-Down Converter

DB Motorized Impeller

Medical Safety Approvals (-M versions) Industrial Heavy Duty Terminals. Output Power up to 1500 W. High Power Density - 18W/in 3

Servo Amplifier PMA 90 / 180

CAP6637A AC-DC Open Loop Converter

Matrix Power Company MH xxx-va series Specification Document

PEAKTRONICS AMC-103 ADDITIONAL FEATURES. AC Motor Controller, 2A AMC-103 AMC-103A AMC-103B

Analog Servo Drive. Features

PP400B060-ND. H-Bridge POW-R-PAK IGBT Assembly 400 Amperes/600 Volts

AC/DC Power Supply Series APPLICATION NOTE

LZS-A500-3 POWER SUPPLY Installation, Operation, and Maintenance Manual. IM-LZSA500-3 January 2008 Revision H

Current Loop Interface Module M 2025D

Features: Phase A Phase B Phase C -DC_A -DC_B -DC_C

IAP200B120 Integrated Advanced PowerStack 200A / 1200V Full-Bridge IGBT Inverter

MDC V, 2A Brushless Controller. User s Guide E. Landon Drive Anaheim, CA

AxCent Servo Drive AB25A100

VF-nC1 Adjustable Speed Drive Engineering Specification

Index 2. G Gain settings 4 31 Glossary of terms A 2 Grommets 2 13

Sealed Interface Control: EC20300

SPECIFICATION, CONTROLS AND ACCESSORIES

TC-750PD8. Switching Power Supply ( PS2 ATX750W 8 0 PLU S ) SPECIFICATION. Revision: 1.0

Silencer Series Brushless Controllers

Yaskawa Electric America Unit Troubleshooting Manual Section Two: Power Checks GPD 506/P5 and GPD 515/G5 (0.4 ~ 160kW)

MLA High Performance Microstepping Driver. User s Guide E. Landon Drive Anaheim, CA

ECC100 Series. -40 ºC to +75 ºC Operation. 100 W - Baseplate Cooled. High Efficiency Resonant Topology. Screw Terminals Available.

µservo drive user s guide

An American Control Electronics Brand PCM4 SERIES USER MANUAL PCM4.

IAP100T120 Integrated Advanced PowerStack 100A / 1200V Three-Phase-Bridge IGBT Inverter

The MPB150 product line is approved to the latest international regulatory standards, and displays the CE Mark.

P o w e r. C O N T R O L S A N D a t h e n a c o n t r o l s. c o m. ATHENA CONTROLS, INC Campus Drive Plymouth Meeting, PA U.S.A.

PWM CONTROL CONNECTION (OPTION) BLU (COMMON) PWM IN (BLK) NOT USED TACHOUT (WHT) DC VOLTAGE (RED) 4X R..38 (9.7)

Technical. Application. Assembly. Availability. Pricing. Phone

GE FANUC Spares. GE Fanuc Automation. Stepping Motor Cube with Pulse and Direction Interface. Programmable Control Products.

MTS Automation P R O D U C T S P E C I F I C A T I O N. MaxPlus Digital Servo Drive. MP-FLX 230 Series. MP-FLX 230 Series. Single- and Dual-Axis

TENTATIVE PP800D120-V01

Linear Power Supplies Data Sheet

5 x 3 x 0.75 Inches form factor. 275 Watts with Forced Air Cooling. Efficiencies up to 92% Standby Power < 0.5 W

10 Amp Digital PWM Motor Speed Controller CV-2110-HD and CV-2110-HDS

Motion Controller 2-Quadrant PWM for Brushless DC-Servomotors

Transcription:

Ametek, Inc. Rotron Technical Products Division 100 East Erie St., Suite 200 Kent, Ohio 44240 User's 120 Volt, 800 Watt and 240 Volt, 1200 Watt Brushless Motor Drive Electronics 5.7" (145 mm) and 7.2" (183 mm) Windjammer Products November 2018 Proprietary Notice "This document has been prepared by the Dynamic Fluid Solutions (DFS) of AMETEK, Inc. and is supplied on the condition that it will be used by the customer solely for the purpose of supporting the installation, operation, service and maintenance of this DFS product. The Dynamic Fluid Solutions (DFS) Division believes that the information contained in this document is accurate and reliable, and much care has been taken in its preparation. However, no responsibility, financial or otherwise, is accepted for any consequences arising out of the use or mis-use of this document or product. The information contained herein is subject to change. Revisions may be issued to advise of such changes and/or additions. The information included in this document shall not be duplicated by the customer nor released, disclosed, or used, in full or in part, for any other purpose other than as stated herein, without the express written consent of the Dynamic Fluid Solutions (DFS) Division of AMETEK, Inc." REV NO.: C D E ECN NO.: 57152 57901 58328 DATE: 3/7/97 5/10/99 6/5/00 APP D: F 58328 11/19/18

Introduction The brushless drive electronics module is used to power a variety of brushless DC motors and blower systems in the Ametek 5.7" (145 mm) and 7.2" (183 mm) Windjammer family. The 800 and 1200 Watt input power designation refers to a nominal mid-range operating point; actual power input will depend upon the application. The Printed Circuit Board (PCB) electronics provides: Conversion of the AC input to a DC bus of approximately 160 VDC (800 Watt) or 310 VDC (1200 Watt), a small signal power source for the analog and digital components, commutation and power electronics, input command, and velocity sensing and feedback. When used in the 5.7"/7.2" blower products, the PCB also supports the motor stator and Hall Effect Rotor Position Sensors, providing a compact and reliable package. The electronics module implements uni-directional, single quadrant speed control. Motor speed is monitored by converting the frequency of the signals from the Rotor Position Sensors to an analog DC voltage. This voltage is compared to the User's Input Command. The compensated error between actual speed and commanded speed is used to control the voltage applied to the motor windings in a manner to minimize the speed error. The Command Input is optically isolated from the AC source and all internal power circuits. A variety of speed control options are available. Protection features include overtemperature and overcurrent sensing and shutdown. A fuse, in-rush current limiter, and MOV voltage transient protector are connected to the AC source. This User's will provide information on the use and operation of the electronics module and its interfaces. Actual blower performance will depend upon the blower characteristics and the User's application. Electrical Performance Characteristics AC Input: 1200 Watt: 180 to 264 VAC RMS, 50/60Hz, single phase; maximum inrush current 15 AMPS RMS, maximum running current 10 AMPS RMS. 800 Watt: 90 to 132 VAC RMS, 50/60Hz, single phase; maximum inrush current 15 AMPS RMS, maximum running current 10 AMPS RMS. Note: Although the unit contains a lock-out feature that detects low voltage conditions, the electronics should not be operated continuously with the AC Input lower than 90 VAC RMS. Also, the maximum blower performance changes with applied line voltage. Isolated Speed Control Input: Analog Input Voltage Range: 2 to +10 VDC nominal, 0 to +18 VDC maximum. Page 2

Isolated Speed Control Input: (continued) Connector: Digital Pulse Input: 150 Hz to 400 Hz, 0 to +10 Volt pulse nominal, 0 to +18 Volt maximum, minimum duty cycle 10%. (It is possible to provide a 10VDC, 12mA source to pin 2 and pulse the ground (sink) at pin 1.) Speed Control Input Current: Less than 12 ma at 10 volts input. Speed Control Drift with Temperature: Analog Mode: Typ. ±15% from nominal speed at +23 o C Digital or Direct Mode: Typ. ±4% from nominal speed at +23 o C 5-Pin nylon flying lead connector. The following AMP plug or equivalent may be used for mating connector: 800 Watt AMP 350810-1 INTERNAL EXTERNAL POST HEADER ASSEMBLY 1200 Watt AMP 350809-1 INTERNAL EXTERNAL Page 3

POST HEADER ASSEMBLY Ambient Temperature: Operational: Storage: 0 o C to +50 o C -40 o C to +85 o C High Potential: Electromagnetic Compatibility: 1500 VAC RMS (50/60Hz) applied for one second between AC input and ground, 2 ma leakage maximum. 1500 VAC RMS (50/60 Hz) applied for one second between AC input and Isolated Speed Control Input, 1 ma leakage maximum. This Ametek family of blower products comply with electromagnetic defined by: interference requirements as & limits. EN50082-1 IEC801-2 IEC801-3 IEC801-4 IEC801-5 Refer to TÜV Rheinland test report number P9571147.01 for severity levels These Ametek products are capable of causing conducted electromagnetic interference on the power mains. In applications where this is a concern, a suitable line filter should be used in the AC mains as near as possible to the blower AC power input. In all cases, when performing associated leakage tests, The measurement circuit must be faithfully reproduced as specified in the applicable agency document. For compliance with IEC555-2 and IEC555-3 line perturbation and flicker requirements consult the factory for assistance. Solutions are available depending on the application. Regulatory Agency Certification: TÜV Rheinland Bauart Certification, qualified per EN60950. Underwriters Laboratories Inc., qualified per UL507. Canadian Standards Association, qualified per C22.2 #113. The Isolated Speed Control Input is a "Safety Extra-Low Voltage Circuit" per EN60950. Locked Rotor test per UL507, condition 8. Page 4

Precautions for Use WARNING: THIS PRODUCT OPERATES FROM AND USES VOLTAGES THAT ARE POTENTIALLY DANGEROUS! FAILURE TO OBSERVE APPROPRIATE SAFETY PRECAUTIONS COULD RESULT IN SERIOUS BODILY INJURY, INCLUDING DEATH IN EXTREME CASES. We recommend that adequate instructions and warnings by the Original Equipment Manufacturer (OEM) include labels clearly stating the precautions necessary for this type of equipment in the application. WARNING: Secure blower prior to initial start to prevent sudden movement and possible damage. NOTE: Please refer to the Ametek Safety Bulletin, number 4930700, included with this User's. Installation Interface: Please refer to the Block Diagram. All electrical connections are made through J1. Safety ground connections should be made to J1 pin 3. Warning! Use care when making initial power connections. Application of main power to the User Speed Command Input pins will result in destruction of the velocity control circuit. Check all connections before applying power! Power Input: The 50/60 Hz AC power source is connected to J1, pins 5 and 4. Speed Command Input (when applicable): The Speed Command is connected to J1, pin 2 (positive) and pin 1 (negative). Page 5

Note: Application of opposite polarity voltages to these input pins may destroy the unit. Operation Prior to initial application of power, check all connections and grounds. Speed Control: Depending upon the option jumpers set at the factory, various speed control modes are available. The control electronics has a built in 25 turn potentiometer that may be used to directly control speed or to adjust motor speed in response to the signals on the Speed Command Input. Direct Control: In this mode, no input is required at the Speed Command Input; J1 pins 1 and 2 must be left open. The internal potentiometer is connected to the drive electronics and may be used to directly control motor speed over the design range. Potentiometer Fully Counter-Clockwise: Motor RPM Maximum Potentiometer Fully Clockwise: Motor RPM Minimum Analog Control: In this mode, an analog signal between 2 to 10 VDC is used to control motor speed. The internal potentiometer is wired to provide scaling of the input voltage. The analog voltage is applied between J1 pin 2(+) and pin 1(-). The analog input is used both for powering the velocity error amplifier and providing the speed command, therefore, a minimum voltage must be present at J1-2 and J1-1 for proper operation. This minimum voltage threshold ensures that the controller will be "OFF" for voltages under 0.8 volts. The command scaling potentiometer is wired such that fully counter-clockwise represents maximum command gain. With the potentiometer fully counter-clockwise: J1-1,2 10 Volts: J1-1,2 0 Volts: Maximum RPM Motor Off Digital Control: In this mode, the internal potentiometer must be set fully counter-clockwise. The User then supplies a Pulse Width Modulated (PWM) signal switching between 0 and 10 volts to the Speed Command Input, J1 pin 2(+) and pin 1(-). The PWM signal may have a base frequency of 150 to 400 Hz. Since the PWM input signal is also used to power the velocity error amplifier, the minimum duty cycle in Digital Mode control is 10%. The motor may rotate slowly at any duty cycle greater than 0%. The Velocity Error amplifier and Filter and Compensation circuits (see the Block Diagram) will convert the pulse width duty cycle to a DC voltage for use by the Commutation and Control circuits. J1-1,2 100% Duty Cycle: J1-1,2 0% Duty Cycle: Maximum RPM Motor Off In the Analog and Digital Modes, due to the location of the Velocity Error Amplifier, the motor will not begin to rotate until a threshold voltage or threshold duty cycle is reached. In the Analog mode, this threshold voltage will 120 Volt/800 Watt & 240 Volt/1200 Watt User's Page 6

also depend upon the setting of the potentiometer. This feature allows the Speed Command Input to also be used as a logical "ON/OFF" signal. With the internal potentiometer set to minimum resistance (fully counter-clockwise), a 2 Volt Speed Command Input (10% duty cycle) will guarantee motor start. Ametek may pre-set the internal gain potentiometer for specific user applications during final factory test. With the Speed Command Input voltage or duty cycle set to minimum, or, in Direct Mode, with the internal potentiometer set fully clockwise, apply AC appropriate to the unit. Increase the Speed Command Input voltage or duty cycle until rotation begins. In the Direct Mode, the motor will begin to rotate slowly; adjust the potentiometer to obtain the desired speed, pressure, or flow. NOTE: For initial testing, or in order to check performance, the AC voltage may be brought up slowly using an adjustable AC voltage source or variable transformer with the Speed Command set to Maximum RPM. Prolonged operation at low line voltages under load is not recommended. The motor must never be allowed to stall when running under low line conditions! Use care when starting the motor with low line conditions! Detailed Operation Refer again to the Block Diagram. Input AC power is rectified and filtered to provide an internal DC bus of approximately 160 VDC (800 Watt) or 310 VDC (1200 Watt). In-rush current is limited using a Negative Temperature Coefficient (NTC) device in series with the Bridge Rectifier. A pre-regulated low voltage power source supplies the analog and digital circuits with approximately 15 VDC. The low voltage source allows operation with input AC voltages as low as 25 VRMS. The Commutation and Control chip further regulates the 15 VDC to provide a stable reference (Ref Voltage) of approximately 6.25 VDC. The User Speed Command Input may be used in the three Modes described above. In Analog Mode (JP5 and JP6 installed), the voltage applied input powers the Velocity Error Amplifier and, through the internal command scaling potentiometer, is compared to the velocity feedback, amplified, and translated into a velocity error voltage that controls the commutation circuits. When the Digital Mode is used (JP5 and JP6 installed), the PWM duty cycle is also converted to power the error amplifier. The internal Command Gain potentiometer may be used to alter the amplitude of the PWM input to the error amplifier. This signal is also converted to an error voltage that controls the commutation circuits. In the Direct Mode (JP2 and JP3 installed), the Command Input is disconnected through the use of factory installed jumpers and the internal potentiometer directly controls the velocity command. The electronics module implements six-step commutation of the brushless DC motor using Hall Effect devices to detect motor rotor position. The Hall Effect information is used to select which MOSFET transistors in the Power Output Stage are turned ON to enable rotation in the desired direction. Opto-isolated Level Shift circuits between the Commutation and Control circuits and the upper rail MOSFET's in the Power Output Stage ensure proper operation over a wide range of AC Power Inputs. The Hall Effect signals are also used by a Frequency to Voltage converter to provide motor velocity feedback. Velocity scaling is determined by the factory based on the motor winding and blower maximum speed. The error between the Analog, Digital, or Direct Mode velocity error voltage is amplified, compensated and translated across the isolation interface using an opto-coupler. This method ensures that temperature variance of the opto-coupler characteristics will have minimal effect on performance. The velocity error is used as a current command which is compared to the Current Feedback and amplified and compensated by the Commutation and Control Error Amplifier. The Page 7

output of this amplifier controls the duty cycle of an internal PWM Modulator which operates at approximately 25 KHz. This frequency ensures good bandwidth and minimum current ripple in the stator. A single sensing resistor in the lower bus supply line is used to measure current. The output of this resistor is used to set the Current Limit and is also fed back to the Commutation and Control Error Amplifier to close a single-quadrant current loop. In Current Limit, the duty cycle of the PWM Modulator is shortened in proportion to the overcurrent condition and the Fault Out signal goes low. The Fault Out signal is filtered and used to pull the Enable input low. The time constant of the filter ensures that the control electronics will "disable" approximately 2 seconds after a continuous overcurrent condition occurs. Overcurrent is a latched fault condition; power must be removed in order to restart the unit. A Negative Temperature Coefficient (NTC) resistor is mounted on the Power Output Stage heatsink. This device will shut down the Commutation and Control logic if the internal temperature exceeds approximately +90 o C. Overtemperature is a latched fault condition; power must be removed in order to restart the unit. If the Overtemperature condition still exists, the unit will not return to normal operation until the heatsink temperature is less than +90 o C. Blower Operation As mentioned, the actual performance of the blower in the User's system will depend upon the application. The ability to control motor speed provides many benefits: 1) Adjusting speed varies the blower output, allowing the User to "tune" the blower to a particular application; 2) The blower may be part of an outer control loop. For example, the User may adjust motor speed to maintain constant pressure or temperature. Page 8

Troubleshooting 1) Unit Will Not Start a) AC Power not applied; b) Connector is miss-wired; c) Polarity of Speed Control Input is reversed; d) In Analog Mode, combination of internal potentiometer setting and input voltage prevents unit from starting; e) In Digital Mode, Speed Control Input duty cycle is too low or base frequency is too low (<150 Hz); f) Motor is stalled, blower impeller is blocked, overcurrent condition exists; g) Controller internal temperature still exceeds +90 o C due to operating point, ambient temperature, or both. h) Fuse has blown. 2) Unit Runs, but Will Not Reach Required Speed a) Blower output capability is undersized for the application; b) Line Voltage is outside normal range; c) Internal pot is improperly adjusted; d) Blower impeller or motor shaft is blocked; e) Insufficient voltage at Speed Command Input. 3) Unit Starts, Runs Briefly, then Stops Controller internal temperature still exceeds +90 o C due to operating point, ambient temperature, or both. Page 9

BLOCK DIAGRAM Page 10