MVH3200D Series High Performance Digital Relative Humidity & Temperature Sensor General Description

Similar documents
MiCo SnP HT-01D HT-01D. Humidity & Temperature Sensor Module. User s Manual. MiCo SnP. 1/16

DTH-14. High Accuracy Digital Temperature / Humidity Sensor. Summary. Applications. Data Sheet: DTH-14

P1P Portable Gaming Audio/Video Multimedia. MARKING DIAGRAM. Features

Application Note. E2 Interface for EE03, EE07 and EE08

APPLICATION NOTE. ATA6629/ATA6631 Development Board V2.2 ATA6629/ATA6631. Introduction

ICS CLOCK SYNTHESIZER FOR PORTABLE SYSTEMS. Description. Features. Block Diagram PRELIMINARY DATASHEET

Programmable 300mA Camera Flash LED Driver

Si501/2/3/4 LVCMOS CMEMS Programmable Oscillator Series

AH1812. Description. Pin Assignments NEW PRODUCT. Applications. Features. Typical Applications Circuit (Note 4) OUTPUT V DD GND 2

1 A Constant-Current LED Driver with PWM Dimming

IS31FL3209 IS31FL CHANNELS LED DRIVER; 1/24 DC SCALING WHITE BALANCE. December 2017

HTU21S Sensor Miniature Relative Humidity and Temperature Sensor

AH5794 SINGLE PHASE HALL EFFECT LATCH FAN MOTOR DRIVER. Description. Pin Assignments NEW PRODUCT. Applications. Features. (Top View) O2 3 V SS TSOT26

P2042A LCD Panel EMI Reduction IC

FLD00042 I 2 C Digital Ambient Light Sensor

AH1815. Description. Pin Assignments. Features. Applications LOW SENSITIVITY MICROPOWER OMNIPOLAR HALL-EFFECT SWITCH AH1815 SC59 SOT553 SIP-3

AH1892 PROGRAMMABLE MICROPOWER OMNIPOLAR HALL-EFFECT SENSOR SWITCH. Pin Assignments. Description NEW PRODUCT. Features.

LDS8710. High Efficiency 10 LED Driver With No External Schottky FEATURES APPLICATION DESCRIPTION TYPICAL APPLICATION CIRCUIT

ASM1232LP/LPS 5V μp Power Supply Monitor and Reset Circuit

Freescale Semiconductor, I

SKY LF: 0.05 to 2.7 GHz SP4T Switch with Integrated Logic Decoder

TSL250RD, TSL251RD, TSL260RD, TSL261RD LIGHT-TO-VOLTAGE OPTICAL SENSORS

SKY LF: 0.02 to 4.0 GHz High Isolation SP4T Absorptive Switch with Decoder

AH1898. Description. Pin Assignments NEW PRODUCT. Applications. Features PROGRAMMABLE MICROPOWER OMNIPOLAR HALL-EFFECT SWITCH U-WLB AH1898

Features. Applications

Ultra-Low Pressure Digital Sensor

Description. Benefits CONTROL LOGIC. Rev 1.2, December 21, 2010 Page 1 of 12

PCS3P73U00/D. USB 2.0 Peak EMI reduction IC. General Features. Applications. Product Description. Block Diagram

PCS3P73U00/D. USB 2.0 Peak EMI reduction IC. General Features. Application. Product Description. Block Diagram

TSYS02D Digital Temperature Sensor

TLE4916-1K. Datasheet. Sense & Control. Low Power Automotive Hall Switch. Rev.1.0,

Description. Benefits. Low Jitter PLL With Modulation Control. Input Decoder SSEL0 SSEL1. Figure 1. Block Diagram. Rev 2.6, August 1, 2010 Page 1 of 8

IS31FL3236A 36-CHANNEL LED DRIVER; SELECTABLE PWM FREQUENCY IS31FL3236A. February 2018

CLOCK DISTRIBUTION CIRCUIT. Features

Fully Integrated Proximity and Ambient Light Sensor with Infrared Emitter and I 2 C Interface

FDMA3028N. Dual N-Channel PowerTrench MOSFET. FDMA3028N Dual N-Channel PowerTrench MOSFET. 30 V, 3.8 A, 68 mω Features. General Description

SPECIFICATION. PRODUCT: Relative Humidity&Temperature Sensor System

CAT5136, CAT5137, CAT5138. Digital Potentiometers (POTs) with 128 Taps and I 2 C Interface

Atmel ATA6629/ Atmel ATA6631 Development Board V2.2. Application Note. Atmel ATA6629/ATA6631 Development Board V

AH1893. Pin Assignments. Description NEW PRODUCT. Features. Applications. Typical Applications Circuit

Is Now Part of To learn more about ON Semiconductor, please visit our website at

TSYS01-FAMILY Digital Temperature Sensors

SKY LF: MHz Low-Noise, Low-Current Amplifier

High Accuracy Ambient Light Sensor with I 2 C Interface

RFX8425: 2.4 GHz CMOS WLAN/Bluetooth Dual-Mode RFeIC with PA, LNA, and SP3T

Data Sheet STSC1 Temperature Sensor IC

ICS High SPL Analog Microphone with Extended Low Frequency Response

Dual Photovoltaic MOSFET Driver Solid-State Relay

SKY LF: GHz High Linearity, Active Bias Low-Noise Amplifier

VSS VDD. Applications. Li + Rechargeable Battery Pack

AH1911/AH1921. Description. Pin Assignments NEW PRODUCT. Features. Applications. Typical Applications Circuit (Note 4) 2 OUTPUT GND 3 1 VDD

AH3574. Description. Pin Assignments NEW PRODUCT. Features. Applications HIGH VOLTAGE HIGH SENSITIVITY HALL EFFECT OMNIPOLAR SWITCH 3 OUTPUT GND 2

SKY LF: 2.2 to 2.8 GHz Two-Way, 0 Degrees Power Divider

Sendyne SFP200MOD Precision Current and Voltage Measurement Module

Is Now Part of To learn more about ON Semiconductor, please visit our website at

Storage Telecom Industrial Servers Backplane clock distribution

AHLxxx Low-Voltage Nanopower Digital Switches

IS31FL3206 IS31FL CHANNEL LED DRIVER; SELECTABLE PWM FREQUENCY. Preliminary Information May 2018

Freescale Semiconductor Data Sheet: Technical Data

LD A low-dropout linear regulator with programmable soft-start. Datasheet. Features. Applications. Description

RoHS compliant, Pb-free Industrial temperature range: 40 to +85 C Footprint-compatible with CDCLVC , 2.5, or 3.3 V operation 16-TSSOP

Is Now Part of To learn more about ON Semiconductor, please visit our website at

SKY LF: 20 MHz to 6.0 GHz GaAs SPDT Switch

LC898302AXA Advance Information

Obsolete Product(s) - Obsolete Product(s)

Data Sheet SHTW2. WLCSP Humidity and Temperature Sensor IC

Si52112-B3/B4 PCI-EXPRESS GEN 2 DUAL OUTPUT CLOCK GENERATOR. Features. Applications. Description. compliant. 40 to 85 C

TSYS01 Digital Temperature Sensor

EFC2J013NUZ/D. Power MOSFET for 1-Cell Lithium-ion Battery Protection 12 V, 5.8 mω, 17 A, Dual N-Channel

CPS131. Data Sheet. Water Resistant Pressure Sensor. Consensic. Preliminary 0.1 January 2013 DAT 0006

RFX8050: CMOS 5 GHz WLAN ac RFeIC with PA, LNA, and SPDT

(Top View) operation modes for setting the output voltage. Fixed output voltage mode senses the output voltage on V OUT, adjustable output voltage

SKY LF: GHz High Linearity, Active Bias Low-Noise Amplifier

Data Sheet. APDS-9702 Signal Conditioning IC for Optical Proximity Sensors with Digital I 2 C Interface. Features. Description.

Datasheet SDP3x-Digital Digital Differential Pressure Sensor

Digital humidity and temperature sensor

General Description. Applications. Power management Load switch Q2 3 5 Q1

Aluminum Electrolytic Capacitors Axial High Temperature, High Ripple Current

Applications. Tape and Reel Device Qualification Packaging AL5802LP4 Commercial X2-DFN ,000/Tape & Reel -7

SKYA21012: 20 MHz to 6.0 GHz GaAs SPDT Switch

PCS2I2309NZ. 3.3 V 1:9 Clock Buffer

SKYA21001: 20 MHz to 3.0 GHz SPDT Switch

SKY LF: 0.5 to 6.0 GHz SPDT Switch, 50 Ω Terminated

SKY LF: 0.1 to 3.0 GHz SP8T Antenna Switch

RFX8053: CMOS 5 GHz WLAN ac RFeIC with PA, LNA, and SPDT

SKY LF: 0.1 to 6.0 GHz GaAs SPDT Switch

Applications AP7350 GND

SKY LF: 0.1 to 3.8 GHz SP6T Antenna Switch

PCS2P2309/D. 3.3V 1:9 Clock Buffer. Functional Description. Features. Block Diagram

7 OUT1 8 OUT2 9 OUT3 10 OUT4 11 OUT5 12 OUT6 13 OUT7 14 OUT8 15 OUT9 16 OUT10 17 OUT11 18 OUT12 19 OUT13 20 OUT14 21 OUT15 22 OUT16 OUT17 23 OUT18

LDS ma, Dual Output LED Flash/Lamp Driver FEATURES APPLICATION DESCRIPTION TYPICAL APPLICATION CIRCUIT

AM4835P. Analog Power P-Channel 30-V (D-S) MOSFET THERMAL RESISTANCE RATINGS. Symbol Maximum Units

Multi SMD LED RGB FEATURES APPLICATIONS. WAVELENGTH (nm) at I F (ma)

High Speed Infrared Emitting Diode, 830 nm, GaAlAs Double Hetero

AH3373. Description. Pin Assignments NEW PRODUCT. Applications. Features HIGH VOLTAGE HIGH SENSITIVITY HALL EFFECT UNIPOLAR SWITCH AH3373

LC75847T/D. 1/3, 1/4-Duty General-Purpose LCD Driver

AP7217 AP mA CMOS LDO. Pin Assignments. Description. Applications. Features. Typical Application Circuit. ( Top View ) AP7217 SOP-8L U1 2

IS31FL3208A 18-CHANNEL LED DRIVER; SELECTABLE PWM FREQUENCY. August 2018

ASM3P2669/D. Peak EMI Reducing Solution. Features. Product Description. Application. Block Diagram

SKY LF: 20 MHz-6.0 GHz GaAs SP4T Switch

Transcription:

Datasheet Rev. 3.3 MVH3200D Series High Performance Digital Relative Humidity & Temperature Sensor General Description [Patents protected & patents pending] MEMS Vision s relative humidity (RH) and temperature (T) sensors are built by combining the company s revolutionary MoSiC technology with its extensive ASIC design experience. This combination enables high levels of performance, such as fast RH measurement response time and high accuracy. The technology also offers a very robust proprietary sensor-level protection, ensuring excellent stability against aging and harsh environmental conditions such as shock and volatile chemicals. The highly miniaturized smart sensors are fully calibrated and provide standard digital I 2 C outputs to enable plug-and-play integration. The output RH & T resolutions can be independently programmed for maximum flexibility and to minimize power consumption, depending on the application and operating conditions. The micro-watt levels of power consumption of these sensors make them the ideal choice for portable and remote applications. MEMS Vision s combined RH/T sensors offer the industry s most competitive performance-to-price value, for a wide range of applications and end users. Features Fast RH response time - Typical 4 seconds time constant High accuracy - Relative humidity (MVH3201D): ±1.5% RH typ. (10 90%RH, 25ºC) - Temperature (MVH3201D): ±0.2 C typ. (-10 80 C) Independent resolution settings for RH and T - 8, 10, 12 or 14 bits Fully compliant I 2 C interface Extended supply voltage range of 1.8V 5.5V Very low power consumption - 1.0 μa avg. current at one RH + T meas. per second (8-bit res., 1.8V supply) Small form factor for use in compact systems - 3 2.4 0.8 mm DFN-style LGA package User Benefits Long Term Stability and Reliability: Proprietary sensing structures and protection technology, robust biasing circuitry, and self-diagnosis algorithms ensure accurate and repeatable measurements. Digital Output: Allows for native interfacing with embedded system components such as FPGAs or off-the-shelf micro-controllers. Fully Calibrated System: Built-in digital sensor calibration ensures high accuracy measurements and linear behavior under varying sensing environments. Applications The MVH3200D series is ideal for use in environmental sensing for consumer electronics, automotive, industrial, agricultural, and other sectors. Some application examples include: OEM products Battery-powered systems Smart phones and tablets Instrumentation Drying HVAC systems Medical equipment Meteorology Building automation White goods Refrigeration equipment Data logging Revision 3.3 MEMS Vision 1/17

Table of Contents 1. Pin Configuration... 4 2. Pin Assignment and Connection Diagram... 4 3. Functional Description... 4 4. Chip Performance Summary... 5 5. Sleep Current... 7 6. Relative Humidity and Temperature Sensor Performance... 8 6.1. Accuracy Tolerances... 8 6.2. Normal Operating Conditions... 9 7. Sensor Interface... 9 7.1. Sensor Communications... 9 7.2. Performing Measurements with the MVH3200D Series... 10 7.3. Accessing the Sensor Non-volatile Memory... 11 7.3.1. Setting the Measurement Resolution... 12 7.3.2. Reading the Sensor ID Number... 13 7.4. I 2 C Timing Specifications... 13 8. Package and PCB Information...14 8.1. Package Drawing... 14 8.2. Tape and Reel Information... 15 8.3. Soldering Information... 15 8.4. PCB Layout Considerations... 16 9. Storage and Handling Information...16 10. Part Numbers...17 List of Tables Table 1: Pin assignment... 4 Table 2: MVH3200D Series Specifications.... 5 Table 3: RH+T measurement times (including wake-up time) at different resolution settings....11 Table 4: Non-volatile memory registers....12 Table 5: Register values for different resolution settings....13 Table 6: I 2 C timing parameters....13 List of Figures Fig. 1: Diagram of pin configuration (top view).... 4 Fig. 2: DFN-style LGA package.... 4 Fig. 3: Connection diagram.... 4 Fig. 4: MVH3200D series functional diagram.... 4 Fig. 5: Sleep current variation over temperature (at V DD = 3.3V).... 7 Fig. 6: Relative humidity and temperature tolerances (RH tolerances given at T A = +25 C).... 8 Fig. 7: Diagram of an I 2 C interconnect with one master and three slave devices.... 9 Fig. 8: I 2 C bus start and stop conditions.... 9 Fig. 9: Typical measurement sequence....10 Fig. 10: Sequence of commands to enter the programming mode....11 Fig. 11: Sequence of commands to modify the relative humidity measurement resolution....12 Fig. 12: I 2 C timing diagram....13 Fig. 13: LGA package drawing....14 Fig. 14: LGA package land pattern (top view)....14 Fig. 15: Packaging tape drawing....15 Fig. 16: Recommended lead-free soldering profile...15 Revision 3.3 MEMS Vision 2/17

Fig. 17: Thermal isolation of sensor using milled PCB openings....16 Revision 3.3 MEMS Vision 3/17

1. Pin Configuration VC SDA SCL 3 2 1 4 5 6 VDD NC VSS Fig. 1: Diagram of pin configuration (top view). Fig. 2: DFN-style LGA package. 2. Pin Assignment and Connection Diagram Table 1: Pin assignment. Pin Name Function 1 SCL 1 I 2 C clock (up to 400 khz) 2 SDA 1 I 2 C data 3 VC A 0.1 µf decoupling capacitor 4 VDD Positive supply 5 NC No connect 6 VSS Negative supply or ground 1Requires a 2.2 kω pull-up resistor. 3. Functional Description The MVH3200D series are fully digital sensors which accurately measure relative humidity and temperature levels. An analog-to-digital converter (ADC) with a configurable resolution is interfaced with an analog multiplexer and two sensors in order to allow for the measurement of both relative humidity and temperature. High precision biasing and clock generation ensures stable operation over a wide temperature range. The sensor can MVH320xD Fig. 3: Connection diagram. be used to measure the ambient relative humidity and temperature in real-time or be used for datalogging, and can interface with any I 2 C compliant system for digital transmission of the acquired data. Calibration data and compensation logic are integrated within the system, such that the chip does not require any user calibration, and is readily compensated for accurate operation over a wide range of temperature and humidity levels. Fig. 4: MVH3200D series functional diagram. Revision 3.3 MEMS Vision 4/17

4. Chip Performance Summary Table 2: MVH3200D Series Specifications. At T A = +25 C, V DD = +1.8 V to +5.5 V unless otherwise noted. PARAMETER CONDITION MIN TYP MAX UNITS RELATIVE HUMIDITY Range 0 100 %RH Accuracy Tolerance 3 Resolution MVH3201D ±1.5 ±1.8 10% to 90% RH MVH3202D ±2.0 ±2.3 MVH3203D ±2.5 ±3.5 20% to 80% RH MVH3204D ±3.5 ±4.5 8 bits 0.7 1.0 14 bits 0.01 0.015 %RH %RH Noise in Humidity (RMS) 14 bits 0.014 %RH Hysteresis ±1.0 %RH Non-Linearity from Response Curve MVH3201D ±0.15 ±0.25 10% to 90% RH MVH3202D ±0.15 ±0.25 MVH3203D ±0.15 ±0.25 20% to 80% RH MVH3204D ±0.15 ±0.25 %RH Long-term Stability 0.1 0.25 %RH/yr Response Time Constant 4 (τ H ) 20% to 80% RH Still air 3.0 4.0 6.0 sec. Temperature Sensitivity 50% RH, 5 to 60ºC 0.05 0.1 %RH/ C TEMPERATURE SENSOR Range -40 125 C Accuracy Tolerance 5 Resolution MVH3201D ±0.2 ±0.3-10ºC to 80ºC MVH3202D ±0.2 ±0.3 MVH3203D ±0.25 ±0.35 0ºC to 70ºC MVH3204D ±0.3 ±0.5 8 bits 0.6 0.9 1.5 14 bits 0.01 0.015 0.025 Response Time Constant 6 (τ T ) 5.0 20.0 sec. Long-term Stability 0.04 C/yr VDD>2.8 V 0.03 0.1 Supply Voltage Dependency 7 1.8 V<VDD<2.8 V 1.25 2.25 C C C/V Revision 3.3 MEMS Vision 5/17

Table 2 (cont d): MVH3200D Series Specifications PARAMETER CONDITION MIN TYP MAX UNITS CHIP TEMPERATURE RANGE Operating Range -40 125 C Storage Range -55 150 C MEASUREMENT TIME Wake-up Time 0.10 8 bits Resolution 0.55 10 bits Resolution Temp. or Humidity 1.31 Including digital 12 bits Resolution compensation 4.50 14 bits Resolution 16.90 SLEEP MODE Sleep Current 8 POWER SUPPLY I SD Chip inactive (-40 to 85ºC) ms 0.6 µα Operating Supply Voltage V DD 1.8 3.3 5.5 V Average Current 9 I Q 8 bits resolution one RH + T meas./s 10 bits resolution one RH + T meas./s 12 bits resolution one RH + T meas./s 14 bits resolution one RH + T meas./s 1.0 1.5 1.7 2.0 2.6 2.8 5.5 7.0 7.1 20.1 24.4 24.4 3For monotonic increases in the range of 10% to 90% RH, after the sensor has been stabilized at 50% RH. See Fig. 6 for more details. 4From initial value to 63% of total variation. 5See Fig. 6 for more details. 6Response time depends on system thermal mass and air flow. 7Sensor accuracy can be optimized for application-specific supply voltages upon request. 8See Fig. 5 for more details. 9Mininum, typical, and maximum average currents are given at a 1.8V, 3.3V, and 5.5V VDD, respectively. µα Revision 3.3 MEMS Vision 6/17

5. Sleep Current The sleep current of the MVH3200D series sensors depends on the operating temperature, as shown in Fig. 5. Note that there is no significant dependence of the sleep current on the supply voltage, V DD. Fig. 5: Sleep current variation over temperature (at V DD = 3.3V). Revision 3.3 MEMS Vision 7/17

6. Relative Humidity and Temperature Sensor Performance 6.1 Accuracy Tolerances The typical and maximum relative humidity and temperature accuracy tolerances for the MVH3200D series sensors are shown in Fig. 6. MVH3201D MVH3202D MVH3203D MVH3204D Fig. 6: Relative humidity and temperature tolerances (RH tolerances given at T A = +25 C). Revision 3.3 MEMS Vision 8/17

6.2 Normal Operating Conditions The sensor has been optimized to perform best in the more common temperature and humidity ranges of 10 C to 50 C and 20% RH to 80% RH (non-condensing), respectively. If operated outside of these conditions for extended periods of time, especially at high humidity levels, the sensors may exhibit an offset. In most cases, this offset is temporary and will gradually disappear once the sensor is returned to normal temperature and humidity conditions. The amount of the shift and the duration of the offset vary depending on the duration of exposure and the severity of the relative humidity and temperature conditions. The time needed for the offset to disappear can also be decreased by using the procedure described in Section 9 of this datasheet. 7. Sensor Interface 7.1 Sensor Communications The MVH3200D series sensor communicates using the Inter-IC (I 2 C) standard bus protocol. To accommodate multiple devices, the protocol uses two bi-directional open-drain lines: a Serial Data Line (SDA) and a Serial Clock Line (SCL). Because these are open-drain lines, pull-up resistors to VDD must be provided as shown in Fig. 7. Several slave devices can share the I 2 C bus, but only one master device can be present on the line. VDD Master SCL SDA Pull-up resistors Slave 1 Slave 2 Slave 3 Fig. 7: Diagram of an I 2 C interconnect with one master and three slave devices. Each transmission is initiated when the master sends a 0 start bit (S), and the transmission is terminated when the master sends a 1 stop bit (P). These bits are exclusively transmitted while the SCL line is high. The waveforms corresponding to these conditions are illustrated in Fig. 8. Start Condition Stop Condition SCL SDA Start SCL SDA Stop Fig. 8: I 2 C bus start and stop conditions. Once the start condition has been set, the SCL line is toggled at the prescribed data-rate, clocking subsequent data transfers. Data on the SDA line is always sampled on the rising edge of the SCL line and must remain stable while SCL is high to prevent false Start or Stop conditions (see Fig. 8). Revision 3.3 MEMS Vision 9/17

Following the start bit, address bits set the device targeted for communications, and a read/write bit indicates the transfer direction of any subsequent data. The master sends the unique 7-bit address of the desired device and a read/write bit set to 1 to indicate a read from slave to master, or to 0 to indicate a write from master to slave. All transfers consist of eight data bits and one response bit set to 0 for Acknowledge () or 1 for Not Acknowledge (N). After the acknowledge signal is received another data byte can be transferred, or the communication can be stopped with a stop bit. The MVH3200D series sensor operates as a slave on the I 2 C bus, and supports data rates of up to 400 khz in accordance with the I 2 C protocol. The default address of the sensor is 0x44. Custom I 2 C addresses can be provided upon request (please contact support@mems-vision.com for details). The sensor can be interfaced with any I 2 C master such as a microcontroller, and the master is responsible for generating the SCL signal for all communications with the MVH3200D series sensor. The official I 2 C-bus specification and user manual documentation can be found at: http://www.nxp.com/documents/user_manual/um10204.pdf. 7.2 Performing Measurements with the MVH3200D Series A measurement sequence consists of two steps, as illustrated in Fig. 9: 1. Wake up the MVH3200D series sensor from its sleep mode and initiate a measurement sequence by sending its I 2 C address and a write bit. 2. Once the relative humidity and temperature measurements are completed by the MVH3200D series chip, read the results by sending the I 2 C address of the sensor and a read bit. The sensor will then transmit the relative humidity and temperature data (if requested) on the bus for the master to capture. Step 1 Initiation of measurement sequence MVH320xD measuring relative S 1 0 0 0 1 0 0 0 P humidity and temperature I 2 C Address + Write bit S 1 0 0 0 1 0 0 1 I 2 C Address + Read bit 15 14 13 12 11 10 9 8 Step 2 Request for measurement data transfer Relative humidity data transfer 15 14 13 12 11 10 9 8 Don t care 7 6 5 4 3 2 1 0 Humidity bits [13:8] Humidity bits [7:0] Data Byte 1 Data Byte 2 Temperature data transfer and end of data transfer Temperature bits [13:6] Temperature bits [5:0] Data Byte 3 Data Byte 4 Master can stop data transmission here if temperature data is not needed. P 7 6 5 4 3 2 1 0 Don t care S Start bit from the master P Stop bit from the master N N P Bits generated by the master Bits generated by the MVH320xD chip Fig. 9: Typical measurement sequence. The entire output from the sensor is 4 bytes. The most significant bits of the relative humidity sensor output come out first, followed by the least significant bits. This is followed by the most and least Revision 3.3 MEMS Vision 10/17

significant bits of the temperature sensor output. The first two and last two bits ( don t care bits) do not contain measurement data and should be discarded. As such, the humidity and temperature measurements are always scaled to 14-bits regardless of the selected resolution of the sensor. The relative humidity (in percent) and the temperature (in degrees Celsius) are obtained as follows: Humidity[13:0] Humidity [%RH] = 100 14 2 1 Temperature[13:0] Temperature [ C] = 165 40 14 2 1 In the event that temperature data is not needed by the user, the read can be terminated by issuing a N after the 2 nd byte. Alternatively, if only 8-bit resolution is desired for the temperature output, the read can be terminated after the 3 rd byte by issuing a N followed by a stop bit. The measurement time depends on the configured sensor resolution. Table 3 lists examples when the resolutions for the relative humidity and temperature measurements are the same. For different relative humidity and temperature resolution settings, the measurement times in Table 2 should be used, along with the 0.1 ms wake-up time. For example, an 8-bit relative humidity measurement and a 12-bit temperature measurement results in a total measurement time of: 0.1 ms + 0.55 ms + 4.5 ms = 5.15 ms. Table 3: RH+T measurement times (including wake-up time) at different resolution settings. Resolution 9 Measurement (bits) time (ms) 8 1.20 10 2.72 12 9.10 14 33.90 9Same resolutions are assumed for both relative humidity and temperature. 7.3 Accessing the Sensor Non-volatile Memory The MVH3200D series non-volatile memory stores its measurement resolution setting and its ID number. To change the sensor resolution or read the ID number, the master must place the MVH3200D series chip into programming mode while the chip is powering up. Figure 10 shows the sequence of commands needed to enter the programming mode, which must be sent within 10 ms after applying power to the sensor. The master must send the I 2 C address and a Write bit followed by the command 0xA0 0x00 0x00. Request for measurement data transfer Apply Power to Sensor Proceed to next step within 10 ms S 1 0 0 0 1 0 0 0 1 0 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 P I 2 C Address + Write Command = 0xA0 Command = 0x00 Command = 0x00 S Start bit from the master P Stop bit from the master Bits generated by the master Bits generated by the MVH320xD chip Fig. 10: Sequence of commands to enter the programming mode. This command takes 120 µs to process, after which the master has access to the non-volatile memory registers listed in Table 4. All of these registers are 16 bits wide. Revision 3.3 MEMS Vision 11/17

To return to normal sensor operation and perform measurements, the master must send the I 2 C address and a Write bit, followed by the command: 0x80 0x00 0x00. Table 4: Non-volatile memory registers. Address Register Description 0x06 Humidity Sensor Resolution Read Register (bits [11:10]) 0x46 Humidity Sensor Resolution Write Register (bits [11:10]) 0x11 Temperature Sensor Resolution Read Register (bits [11:10]) 0x51 Temperature Sensor Resolution Write Register (bits [11:10]) 0x1E Read Sensor ID Upper 2 bytes 0x1F Read Sensor ID Lower 2 bytes 7.3.1 Setting the Measurement Resolution The MVH3200D series relative humidity and temperature measurement resolutions can be set independently to 8, 10, 12, or 14 bits by writing to the non-volatile memory, and are initially set to 14 bits by default. The procedure to set the humidity sensor resolution is illustrated in Fig. 11. The relative humidity and temperature resolution can be read in registers 0x06 and 0x11, respectively, or written in registers 0x46 or 0x51. The resolution information is stored in bits [11:10] of these registers, as listed in Table 5. All of the other bits in these registers must be left unchanged. As such, before writing new resolution settings, the contents of the read registers must be read, and only bits [11:10] can be changed in the write registers. Once bits [11:10] are changed to set the desired resolution, the entire register must be written back to the MVH3200D series chip. Step 1 Write the register address S 1 0 0 0 1 0 0 0 0 0 0 0 0 1 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 P I 2 C Address + Write Register Address 0x06 Command = 0x00 Command = 0x00 Step 2 Read the register contents S 1 0 0 0 1 0 0 1 I 2 C Address + Read 7 6 5 4 3 2 1 0 Status (Success = 0x81) 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 P Register Value [15:8] Register Value [7:0] N Step 3 Change bits [11:10] of the register to the desired resolution setting, without changing the other bits Step 4 Write the register contents back S 1 0 0 0 1 0 0 0 0 1 0 0 0 1 1 0 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 P I 2 C Address + Write Register Address 0x46 Register Value [15:8] Register Value [7:0] S Start bit from the master P Stop bit from the master Bits generated by the master Bits generated by the MVH320xD chip Fig. 11: Sequence of commands to modify the relative humidity measurement resolution. Revision 3.3 MEMS Vision 12/17

Table 5: Register values for different resolution settings. Resolution register bits [11:10] Resolution (bits) 00 B 8 01 B 10 10 B 12 11 B 14 The sensor non-volatile memory requires 120 µs to load the data into the registers after step 1, and requires 14 ms to write the data after step 4. Failure to comply with these processing times may result in data corruption and introduce errors in sensor measurements. The procedure to change the temperature sensor resolution is the same as that depicted in Fig. 11, except the register address in Step 1 must be set to 0x11 and the register address in Step 4 will be 0x51. 7.3.2 Reading the Sensor ID Number The sensor ID is a 32-bit number, and can be read in a similar fashion as illustrated in steps 1 and 2 of Fig. 11, using the appropriate register address values. The ID number is stored in two registers, with the upper and lower 16 bits stored in register addresses 0x1E and 0x1F, respectively. 7.4 I 2 C Timing Specifications The timing diagram for all I 2 C communications is shown in Fig. 12, and the minimum and maximum values for each critical timing parameter (e.g., setup times, hold times) are listed in Table 6. t su-data t h-start t idle SDA SCL t h-start t h-data t high t su-start t low t su-stop Fig. 12: I 2 C timing diagram. Table 6: I 2 C timing parameters. Parameter Symbol Min Max Units SCL frequency f SCL 20 khz Start bit setup time t su-start 0.1 µs Start bit hold time t h-start 0.1 µs Minimum SCL low/high widths t low t high 0.6 µs Data setup time t su-data 0.1 µs Data hold time t h-data 0 0.5 µs Stop bit setup time t su-stop 0.1 µs SDA unused time between stop and start bit t idle 1 µs Revision 3.3 MEMS Vision 13/17

8. Package and PCB Information The MVH3200D series sensors are packaged in a 3 2.41 0.8 mm 6-pin dual-flat no-leads (DFN)-style LGA package. 8.1 Package Drawing The mechanical drawing of the LGA package is shown in Fig. 13, and a suitable land pattern for soldering the sensor to a PCB is shown in Fig. 14. The units used for all dimensions are mm. Fig. 13: LGA package drawing. TOP VIEW OF PCB 0.30 0.52 1.37 Package Outline 0.5 1.00 BSC Fig. 14: LGA package land pattern (top view). Revision 3.3 MEMS Vision 14/17

8.2 Tape and Reel Information The MVH3200D series sensors can be shipped in tape and reel packaging, enclosed in sealed anti-static bags. Standard packaging sizes are 400, 1500, and 2500 units (please contact MEMS Vision for other volumes). The tape has a 470mm leader (117 pockets) and a 410mm trailer (103 pockets). A drawing of the packaging tape is shown in Fig. 15, which also shows the sensor orientation. 0.30 2.00 4.00 4.00 Ø1.55 Ø1.0 min 1.75 3.30 MVH 33AA 3.50 8.0 1.40 2.70 R0.30 8.3 Soldering Information Fig. 15: Packaging tape drawing. Standard reflow ovens can be used to solder the MVH3200D series sensor to the PCB. The peak temperature (T p ) for use with the JEDEC J-STD-020D standard soldering profile is 260 C. For manual soldering, the contact time must be limited to 5 seconds at up to 350 C. In either case, if solder paste is used, it is recommended to use no-clean solder paste to avoid the need to wash the PCB. Note that reflow soldering is recommended for optimal performance. The recommended lead-free (RoHS compliant) reflow soldering profile is shown in Fig. 16. Fig. 16: Recommended lead-free soldering profile After soldering, the humidity sensor element should be exposed to a humidity of 75% RH for at least 12 hours in order to rehydrate the element. Otherwise, there may be an initial offset in the relative humidity readings, which will slowly disappear as the sensor gets exposed to ambient conditions. Revision 3.3 MEMS Vision 15/17

8.4 PCB Layout Considerations When designing the PCB, undesired heat transfer paths to the MVH3200D series chip must be minimized. Excessive heat from other components on the PCB will result in inaccurate temperature and relative humidity measurements. As such, solid metal planes for power supplies should be avoided in the vicinity of the sensor since these will act as thermal conductors. To further reduce the heat transfer from other components on the board, openings can be milled into the PCB as shown in Fig. 17. Milled opening MVH320xD MV3001D Milled opening Fig. 17: Thermal isolation of sensor using milled PCB openings. 9. Storage and Handling Information Once the sensors are removed from their original packaging, it is recommended to store them in metal-in antistatic bags. Polyethylene antistatic bags (light blue or pink in color) should be avoided as they may affect sensor accuracy. The nominal storage conditions for the MVH3200D series chip are at temperatures in the range of 10 to 50 C and at humidity levels within the range of 20% to 60% RH. If the chip is stored outside of these ranges for extended periods of time, the relative humidity sensor readings may exhibit an offset. The sensor can be brought back to its calibration state by applying the following reconditioning procedure: 1. Baking at a temperature of 100 C with a humidity < 10% for 10-12 hours. 2. Rehydrating the sensor at a humidity of 75% RH and a temperature between 20 to 30 C for 12 to 14 hours. Note that the sensor may also return to its calibrated state if left at ambient conditions for a longer period of time.

10. Part Numbers Evaluation Board MVEVB3 MVH3200D series evaluation board and USB cable MVH3201D MVH3201D MVH3201D a 3 2.4 0.8 mm 6-pin DFN-style LGA package MVH3201D-M MVH3201D sensor module, for use with the MVEVB3 evaluation board MVEVB3-K1 Evaluation kit, includes MVEVB3 and MVH3201D-M (x3) MVH3202D MVH3202D MVH3202D a 3 2.41 0.8 mm 6-pin DFN-style LGA package MVH3202D-M MVH3202D sensor module, for use with the MVEVB3 evaluation board MVEVB3-K2 Evaluation kit, includes MVEVB3 and MVH3202D-M (x3) MVH3203D MVH3203D MVH3203D a 3 2.41 0.8 mm 6-pin DFN-style LGA package MVH3203D-M MVH3203D sensor module, for use with the MVEVB3 evaluation board MVEVB3-K3 Evaluation kit, includes MVEVB3 and MVH3203D-M (x3) MVH3204D MVH3204D MVH3204D a 3 2.41 0.8 mm 6-pin DFN-style LGA package MVH3204D-M MVH3204D sensor module, for use with the MVEVB3 evaluation board MVEVB3-K4 Evaluation kit, includes MVEVB3 and MVH3204D-M (x3) 2017 MEMS Vision Worldwide. All rights reserved. MEMS Vision, its logo, and MoSiC are trademarks or registered trademarks of MEMS Vision International Inc., Canada, and its subsidiaries in Canada and other countries. Other trademarks used herein are the property of MEMS Vision or their respective third party owners. The information in this document is believed to be accurate in all respects at the time of publication, but shall not be regarded as a guarantee of conditions or characteristics. MEMS Vision assumes no responsibility for errors and omissions, and disclaims responsibility for any consequences resulting from the use of information included in this document. MEMS Vision also assumes no responsibility for the functioning of features or parameters not explicitly described herein. MEMS Vision reserves the right to make changes without further notice. MEMS Vision makes no warranty, representation, or guarantee regarding the suitability of its products for any particular purpose, nor does MEMS Vision assume any liability arising out of the application or use of any product or circuit and, specifically DISCLAIMS ANY AND ALL LIABILITY, including without limitation consequential or incidental damages, as well as warranties of non-infringement of intellectual property rights of any third party. MEMS Vision products are not designed, intended, or authorized for use in applications intended for safety, emergency stopping, or supporting or sustaining life, or for any other application in which the failure of the MEMS Vision product could create a situation where personal injury or death may occur. Should Buyer purchase or use MEMS Vision products for any such unintended or unauthorized application, Buyer shall indemnify and hold MEMS Vision harmless against all claims and damages. www.mems-vision.com info@mems-vision.com Revision 3.3 MEMS Vision 17/17