Led Spot MR16 10W Neutral White with 700 ma constant current driver by CDE Technology BV

Similar documents
Led Spot MR16 10W Cold White by CDE Technology BV

Led 12V 3W Spot Light GU5.3 by Tuono Lighting

High Bay Led Lamp by Glo

LED T5 30cm Warm White by BS Ledlight

20W TL 324 smd LED Warm White by Simplify-It

Led Tube Light KLV-T8-121-WA by KLV Ledverlichting

Flood Light LVS-70 Warm White by Ledverlichting Soest

Line Lite International BV 150 watt Cree PowerLED Streetlight 50 x 3 watt IP65 60 degr

Line Lite International BV Petrol Gas Station Light 50 watt IP65

Line Lite International BV 7W Dimmable Downlight Sharp

Lamp measurement report 1 Feb 09 for Line Lite International BV Line Lite International BV Sharp 4W GU10 WW

LVS C42 GU10 4W WW by Ledverlichting Soest

Lamp measurement report 25 March 09 for LedNed LedNed spotlight MR16GU5.3 WW

LVS D01 GU10 3W WW dim by Ledverlichting Soest

1200 x 300 mm led panel by ElektoLED

LVS A16 MR16 3x3W Cree by Ledverlichting Soest

LVS C76 GU10 9W Nichia by Ledverlichting Soest

Negative ion Lamp GTFL-13 by GreenTubes

Pharox MR16 by Lemnis

Lamp measurement report - 13 May 2012 Led TL 120 cm 18W 6500K by Prolumia

Lamp measurement report - 13 Nov 2012 LED light bulb E14 dimmable by Oxxy Light

Lamp measurement report - 11 Feb 2013 E27 led light bulb XP-e Cree 8x1W by TOP.LED.SHOP

Lamp measurement report - 13 April 2016 ONT x18 by Triolight B.V.

Orb Optronix, Inc th Ave Kirkland, WA Device Ref #: P30LN-L540-C27-B25 tel: fax: lm x 0.

Orb Optronix, Inc th Ave Kirkland, WA Device Ref #: P30LN-L600-C30-B25 tel: fax: lm x 0.

Orb Optronix, Inc th Ave Kirkland, WA Device Ref #: P20-L360-C27-B25 tel: fax: lm x 0.

Basic lighting quantities

Report No.: EASZE Page 2 of 14

Report No.: HZ a/R2. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Photometric Test Report

Report No.: HZ b. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

PAR30S GU W OUTPUT RANGE: VIVID SERIES OUTPUT RANGE: BRILLIANT SERIES COLOR TEMPERATURE RANGE

Photometric Test Report

Address: IES LM Luminaire Description: Indoor High Bay Light Source: LGIT 5630 Ballast/Driver: VPL Overdrive L320HBL46DIM/50K

Report No.: HZ b. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

NVLAP LAB CODE LM Test Report. For. MaxLite Inc. (Brand Name: MaxLite) 12 York Ave West Caldwell NJ 07006

LM Test Report. for. Philips (China) Investment Co., Ltd. InstantFit LEDtube Model:

57-100W-XXK-WPH12-SG W-40K-WPH12-SG W-57K-WPH12-SG

Report No.: HZ a/R2. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

NVLAP LAB CODE LM Test Report For. Outdoor Pole/Arm-mounted Area and Roadway Luminaires

NVLAP LAB CODE LM Test Report. For GREEN LOGIC LED ELECTRICAL SUPPLY INC. Outdoor Full-Cutoff Wall-mounted Area Luminaire

Photometric Test Report

LM-79 Test Report. Electrical and Photometric tests as required by IESNA LM-79 test standard

Report No.: HZ h/R1. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

(Lumens) Stabilization Time CRI (K) (Light & Power) Table 1 Executive Data Summary

Photometric Test Report

Sample Report. IES LM Test Report. LED Lamp 001. Test results reported for: Orb Optronix report: LEDC WG. Original issue date:

(Lumens) Stabilization Time CRI (K) (Light & Power) Table 1 Executive Data Summary

Eternal Shine Technology Co.,Ltd. EST

True energy-efficient lighting: the fundamentals of lighting, lamps and energy-efficient lighting

LM Test Report

Ledison LED Troffer Light Back Lit Structure


OUTPUT RANGE: VIVID SERIES OUTPUT RANGE: BRILLIANT SERIES COLOR TEMPERATURE RANGE. Form Factor Operating Temperature Electrical Dimming and Flicker

Report No.: HZ c/R1. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

NVLAP LAB CODE LM Test Report. For. Maxlite Inc. (Brand Name: ) 12 York Avenue, West Caldwell, NJ

LED Dimmable High Bay 150W PRODUCT DATA SHEET

LM Test Report. For FALKOR INDUSTRY INC. (Brand Name: Falkor Lighting) 5580 Bandini Blvd Bell,CA USA

OUTPUT RANGE: VIVID SERIES OUTPUT RANGE: BRILLIANT SERIES COLOR TEMPERATURE RANGE. Form Factor Operating Temperature Electrical Dimming and Flicker

LM Test Report. for EiKO Global, LLC. 25W Floodlight Model: FLM-2C-N-U

LM Test Report

Report No.: HZ k/R1. (Lumens) Stabilization Time CRI (K) (Light & Power) Table 1: Executive Data Summary

NVLAP LAB CODE LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name: N/A) 188 S. Northwest Highway Cary, IL 60013

NVLAP LAB CODE LM Test Report. For. LED2 Lighting Group, Inc. (Brand Name: LED2) 600 Minnesota Ave, Kansas City, KS 66101

Visibility, Performance and Perception. Cooper Lighting

NVLAP LAB CODE LM Test Report. For. LED2 Lighting Group, Inc. (Brand Name: LED2) 600 Minnesota Ave, Kansas City, KS 66101

NVLAP LAB CODE LM Test Report. Outdoor Full-Cutoff Wall-mounted Area Luminaires. Model name(s): LWA-50W

NVLAP LAB CODE LM Test Report. Outdoor Non-Cutoff and Semi-Cutoff Wall-mounted Area Luminaires

Photometric Test Report

NVLAP LAB CODE LM Test Report. For ATG ELECTRONICS CORP. (Brand Name: N/A) th Street Rancho Cucamonga, CA 91730

NVLAP LAB CODE LM Test Report. For BEYOND LED TECHNOLOGY Mountain Industrial Blvd. Suite A-1 Tucker, GA USA

Lumen lm 1 lm= 1cd 1sr The luminous flux emitted into unit solid angle (1 sr) by an isotropic point source having a luminous intensity of 1 candela

Report No.: HZ w. Stabilization Time (Light & Power) CRI. Table 1: Executive Data Summary. Figure 1- Overview of the sample

LM Test Report

Radiometric and Photometric Measurements with TAOS PhotoSensors

LM Test Report

Catalog Number UPC Number LED Spot Bullet Flood Light 42W 4204 Lumens White

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD. (Brand Name: THAILIGHT)

NFMS THEORY LIGHT AND COLOR MEASUREMENTS AND THE CCD-BASED GONIOPHOTOMETER. Presented by: January, 2015 S E E T H E D I F F E R E N C E

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MAXLED) 12 York Avenue West Caldwell, NJ

Report No.: HZ f. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

71332 LED Dusk To Dawn (Area Light)

NVLAP LAB CODE LM Test Report. For MAXLITE,INC. (Brand Name: N/A) 12 YORK AVENUE WEST CALDWELL,NJ 07006

RoHS QPL ID # PNZ72BAB

RoHS QPL ID # PNZ72BAB

Cat# LED Wall-PACK

RoHS VAC 50/60HZ 0.38A Max W PF LM LM/W x 90

07-Lighting Concepts. EE570 Energy Utilization & Conservation Professor Henry Louie

Report No.: HZ j. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

NVLAP LAB CODE LM Test Report. For EIKO GLOBAL, LLC W 84th St., Shawnee, KS

NVLAP LAB CODE LM Test Report. Outdoor Non-Cutoff and Semi-Cutoff Wall-mounted Area Luminaires. Model name(s): WML-50W

RoHS QPL ID # PLC6V1PABNUJS

LM Test Report

LM Test Report. For. Revolution Lighting Technologies, Inc. (Brand Name: ) 2280 Ward Ave. Simi Valley, CA

LM Test Report. For. Builders Pack. ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China

OUTPUT RANGE: VIVID SERIES OUTPUT RANGE: BRILLIANT SERIES COLOR TEMPERATURE RANGE. Form Factor Operating Temperature Electrical Dimming and Flicker

Cat# 71426A LED Wall-PACK QPL ID # PLO3JLI4OV69

SpecSheet_AR111_18.5W_VIVID UND BRILLIANT 2 SpecSheet_AR111_12.5W_VIVID UND BRILLIANT 7 SpecSheet_AR111_6W_VIVID UND BRILLIANT 12

Report No.: HZ h. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

NVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING)

Transcription:

Led Spot MR16 10W Neutral White with 700 ma constant current driver by CDE Technology BV Page 1 of 18

Summary measurement data parameter Color temperature Luminous meas. remark result 4130 K Neutral white 248 Cd Measured straight underneath the light bulb intensity I v Beam angle 62 deg Power P 10.4 W Power Factor 0.86 For every 1 kwh net power consumed, there has been 0.6 kvahr for reactive power. Luminous flux 252 Lm Luminous 24 Lm/W efficacy CRI_Ra 75 Color Rendering Index. Coordinates x=0.3754 chromaticity and diagram y=0.3765 Fitting 230V It uses a current driver for the leds, converting 230 V mains into current. PAR-value 2.2 The number of photons seen by an average plant µmol/s/m 2 when it is lit by the light of this light bulb. Value valid at 1 m distance from light bulb. S/P ratio 1.6 This factor indicates the amount of times more efficient the light of this light bulb is perceived under scotopic circumstances (ow environmental light level). D x H external 50 x 72 mm External dimensions of the light bulb. dimensions D luminous area 46 mm Dimensions of the luminous area (used in Eulumdat file). This is equal to the ID of the reflector end at the front of the light bulb. Page 2 of 18

General remarks The ambient temperature during the whole set of measurements was 23-24.5 deg C. Warm up effect: during the warm up time the illuminance decreased with 10 % and the consumed power decreased with 1 %. Voltage dependency: the power consumption and illuminance do vary lineasly when the voltage is varied from 200-250 V. This article contains some additional photos at the end Page 3 of 18

Overview table Lamp measurement report 30 Oct 2009 The overview table is explained on the OliNo website. Please note that this overview table makes use of calculations, use this data with care as explained on the OliNo site. Eulumdat light diagram This light diagram below comes from the program Qlumedit, that extracts these diagrams from an Eulumdat file. It is explained on the OliNo site. The light diagram giving the radiation pattern. It indicates the luminous intensity around the light bulb. This light bulb has the same Page 4 of 18

light diagram for the C0-C180 as for the C90-C270 plane since it has symmetry over is height axis. Illuminance Ev at 1 m distance, or luminous intensity Iv Herewith the plot of the averaged luminous intensity Iv as a function of the inclination angle with the light bulb. The radiation pattern of the light bulb. This radiation pattern is the average of the light output of the light diagram given earlier. Also, in this graph the luminous intensity is given in Cd. These averaged values are used (later) to compute the lumen output. Page 5 of 18

Intensity data of every measured turn angle at each inclination angle. This plot shows per inclination angle the intensity measurement results for each turn angle at that inclination angle. There normally are differences in illuminance values for different turn angles. However for further calculations the averaged values will be used. When using the average values per inclination angle, the beam angle can be computed, being 62º. This is the average value but as the light bulb has a symmetry over its height axis, this angle is valid for all turn-angles the light bulb is looked at. Luminous flux With the averaged illuminance data at 1 m distance, taken from the graph showing the averaged radiation pattern, it is possible to compute the luminous flux. The result of this computation for this light spot is a luminous flux of 252 Lm. Luminous efficacy The luminous flux being 252 Lm, and the power of the light bulb being 10.4 W, yields a luminous efficacy of 24 Lm/W. A power factor of 0.86 means that for every 1 kwh net power consumed, a reactive Page 6 of 18

component of 0.6 kvar was needed. Light bulb voltage (used on power supply!) 230 VAC Light bulb current 53 ma Power P 10.4 W Apparent power S 12.1 VA Power factor 0.86 Of this light bulb the voltage across ad the resulting current through it+its constant current driver power supply are measured and graphed. See the OliNo site how this is obtained. Voltage across and current through the lightbulb The current does not exactly have a sinusiodal form but it looks like it (more a swuare wave). The phase is the same as the voltage waveform. It contains some peaks that will lead to some higher harmonics. All together the powerfactor is fine with a value > 0.85. Also the power spectrum of the current is determined. Page 7 of 18

Current power spectrum in % of the first harmonic (50 Hz). The peaks in the current result in the appearance of the higher harmonics. Color temperature and Spectral power distribution Page 8 of 18

The spectral power distribution of this light bulb, energies on y-axis valid at 1 m distance. The measured color temperature is about 4125 K which is neutral white. This color temperature is measured straight underneath the light bulb. Below a graph showing the color temperature for different inclination angles. Color temperature as a function of inclination angle. The measurement of CCT (correlated color temperature) has been stopped when less than 5 lux (low illumination value) was measured or when the inclination angle was 90 degrees. With this lamp at 70 degree inclination angle less than 5 lux was measured (at the specific measurement distance). The maximum beam angle is 62 degrees, meaning at an inclination angle of 31 degrees Page 9 of 18

there is 50 % left of the initial illuminance value at 0 degrees. Most of the light energy is within this area. In this area the color temperature stays within 2 % of its value at 0 degrees inclination angle. PAR value and PAR spectrum To make a statement how well the light of this light bulb is for growing plants, the PARarea needs to be determined. See the OliNo website how this all is determined and the explanation of the graph. The photon spectrum, then the sensitivity curve and as result the final PAR spectrum of the light of this light bulb The PAR number for this light results in 2.2 µmol/s/m 2. This value is valid at 1 m distance from the light bulb and valid roughly inside its beam angle. The PAR efficiency is 64 % (valid for the PAR wave length range of 400-725 nm). So maximally 64 % of the total of photons in the light is effectively used by the average plant (since the plant might not take 100 % of the photons at the frequency where its relative sensitivity is 100 %). Page 10 of 18

S/P ratio The S/P ratio and measurement is explained on the OliNo website. Here the results are given. The power spectrum, sensitivity curves and resulting scotopic and photopic spectra (spectra energy content defined at 1 m distance). The S/P ratio is 1.6. More info will come in a separate article. Page 11 of 18

Chromaticity diagram The chromaticity space and the position of the lamp s color coordinates in it. The light coming from this lamp is close to the Planckian Locus (the black path in the graph). Its coordinates are x=0.3754 and y=0.3765. Page 12 of 18

Color Rendering Index (CRI) or also Ra Herewith the image showing the CRI as well as how well different colors are represented (rendered). The higher the number, the better the resemblance with the color when a black body radiator would have been used (the sun, or an incandescent lamp). Each color has an index Rx, and the first 8 indexes (R1.. R8) are averaged to compute the Ra which is equivalent to the CRI. CRI of the light of this lightbulb. The value of 75 is (a bit lower) than 80 which is considered a minimum value for indoor usage. Note: the chromaticity difference is 0.0014 indicates the distance to the Planckian Locus. Its value is lower than 0.0054, which means that the calculated CRI result is meaningful. Voltage dependency The dependency of a number of lamp parameters on the lamp voltage is determined. For this, the lamp voltage has been varied and its effect on the following light bulb parameters measured: illuminance E_v [lx], the lamppower P [W], the (Correlated) Color Temperature [K] and the luminous efficacy [Lm/W]. Page 13 of 18

Lamp voltage dependencies of certain light bulb parameters, where the value at 230 V is taken as 100 %. There is some variation of the illuminance and consumed power when the grid voltage is varied widely over a range of 200-250 V. When the voltage at 230 V varies with + and - 5 V, then the illuminance varies within 1 %, so when abrupt voltage changes occur this effect is not visible in the illuminance output. Warm up effects After switch on of a cold lamp, the effect of heating up of the lamp is measured on illuminance E_v [lx], color temperature CT or correlated color temperature CCT [K], the lamppower P [W] and the luminous efficacy [lm/w]. Page 14 of 18

Effect of warming up on different light bulb parameters. At top the 100 % level is put at begin, and at bottom at the end. Page 15 of 18

The warm-up time is about 25 minutes. During this time the illuminance value and the consumed power decrease with 10 % and 1 % respectively. Additional photos Close up of the LED inside the lamp reflector Page 16 of 18

Side view of the light bulb Page 17 of 18

The used current driver This current driver is set at 700 ma when the light bulb was measured. Disclaimer The information in this OliNo report is created with the utmost care. Despite of this the information can have inaccuracies. OliNo cannot be held liable for the content of the information in this report nor for the consequences of its use. The data in this report is not legally binding. Page 18 of 18