Single phase energy meter with Serial Modbus interface

Similar documents
3 phase energy meters with integrated Serial Modbus interface

3-Phase Energy meter with serial S-Bus interface

3-Phase Energy meter with Serial S-Bus interface

3-Phase Energy meter for high current measurement converter with Serial S-Bus interface

Data sheet Energy meter with integrated S-Bus interface

3-phase energy meters with S0 pulse output

Three-phase energy meter for transformer connection with S0 pulse output

S0 pulse counter. with S-Bus interface. Main features: Order number. Technical Data. Mounting

Data sheet AWD3 3-phase, bidirectional energy meter for current converter metering with integrated S0-output Controls Division

COUNTIS E23. Three-phase energy meter Direct - 80 A MODBUS. Instruction manual. en/countis-e2x

3-phase meter with direct connection and pulse or Modbus RS485 output

METERSUK. SmartLink D Y N A M i T E. EM415 MOD Series. User Manual KEY FEATURES INDEX 3. TECHNICAL DESCRIPTION. Single Phase Metering

Energy Management Energy Meter Type EM340

1 2 3 GridVis Pulse output 2 tariffs Modbus MID M-Bus

Energy Management Energy Meter Type EM111

Energy Management Energy Meter Type EM112

Energy Management Energy Analyzer Type EM111

Single phase meter with direct connection and pulse or Modbus RS485 output

Energy Management Energy Meter Type EM21 72R Retro-Fit

Energy Meters for DIN Rail Mounting Electric energy meter WS0101, WS0102,WS1102 WS0301, WS0302,WS1302

KE-N80. Item: kg/pc unit Item No. KE-N80 three phase Energy Meter for direct connection 80A 0, DIN rail 35mm

RI-D440. Three Phase easywire Multifunction DIN Rail Energy Meter. Telephone : +44 (0) Displayed Parameters

MID. Energy Management Energy Meter Type EM23 DIN. Product Description. Type Selection. How to order EM23 DIN AV9 3 X O1 PF A EM23 DIN

EMU Electronic AG. Jöchlerweg 4 CH-6340 Baar Switzerland Telefon +41 (0) Fax +41 (0)

Energy Management Energy Analyzer Type EM112

PRELIMINARY DATA SHEET RI-D140. Three Phase Multifunction DIN Rail Energy Meter (MID Certified) MID

12/2 Product overview. 12/3 7KT1 14, 7KT1 53 E-counters. 12/9 7KT1 11, 7KT1 12 digital measuring devices. 12/11 7KT1 0 analog measuring devices

Energy Management Energy Analyzer Type EM280-72D

MID. Energy Management Energy Analyzer Type EM11 DIN. Product Description. How to order EM11 DIN AV8 1 X O1 PF. Type Selection EM11 DIN

Energy Management Energy Analyzer Type EM270-72D

Energy Management Energy Meter GM3T E GM3T-RS485 E

MID. Energy Management Energy Meter Type EM33 DIN. Product Description. How to order EM33 DIN AV3 3 X XS PF. Type Selection EM33 DIN

MID energy meter B21 Single-phase energy meter, 65 A

RI-F200 Series. Single and Three Phase Multifunction Energy Meter. Telephone : +44 (0) Displayed Parameters

COUNTIS E27/E28 Three-phase energy meter Direct - 80 A Ethernet

Power-meters three-phase

Energy Management Three-phase energy meter with output modules Type EM4-DIN

7E Series - Energy meter. Features PTB 1

ENGLISH 3 Phase Multi-function Power Meter 1/5A MID MID

Energy Management Energy Meter with plug-in Output Modules Type EM4-DIN

EASTRON SDM630MCT-RJV / SDM630MCT-RJA User Manual V1.1. Three phase multifunction din rail energy meter

Measuring Instruments. Measuring Instruments

DMTME-96 2CSG133030R4022 M DMTME-I Operation and assembly instructions 2CSG163030R4022 M CSG445001D0202

ENA33LCD. Power line analyzer. User and service manual. Obrezija 5 SI-1411 Izlake

PRELIMINARY DATA SHEET. RI-F300 Series. easywire Single and Three Phase Multifunction Energy Meter (MID Certified) MID

Introduction DIN rail mounted electricity meters

MID. RI-F300 Series. easywire Single and Three Phase Multifunction Energy Meter (MID Certified) MID

INDUSTRIAL+COMMERCIAL ZMD310AT/CT TECHNICAL DATA. Measurement Accuracy. Measurement Behaviour. MID-specific data. Current (for Class B) General

ma/bcd Converter Model MFC-201 ma/bcd The MFC-201 ma/bcd Converter is a device designed to convert a DC current signal into BCD (8421) signals.

Tegra 710 and 810 Digital metering with RS485 Modbus TM o/p

PRELIMINARY DATA SHEET. RI-F400 Series. easywire Single and Three Phase Multifunction Energy Meter

Energy Management Energy Analyzer Type EM210 MID

Energy Management Energy Meter GM3D

Multifuncion Measuring Device, 4 mod. DIN, connection via CT, with RS485 port

Energy Management Power Analyzer with plug-in Output Modules Type W M22-DIN

RTU560. Multimeter 560CVD03. Power Measuring Display. Characteristics. Application. Data Sheet Multimeter 560CVD03

Power Meter Series PM3200 Functions and characteristics

Power analyzers and Energy Meters Power Analyzer Type WM14-96

PLA 33. Power line analyzer. User and service manual. version 2.4

INTELLIGENT DIGITAL MULTI POWER METER [DIC-MPM]

PowerLogic power-monitoring units. PM700 series power meter. Technical data sheet

Energy Management Energy Analyzer Type EM210

Energy Management. Type WM14 DIN Advanced version. Product Description 3-phase advanced power analyzer with integrated programming

Centrale de mesure Power Meter PM500 Merlin Gerin

Environmental Influences. Display. Inputs and Outputs. Electromagnetic Compatibility. Communication Interfaces. Insulation Strenght.

Protection components

Universal-Transducer Multi-E11-MU

Multifuncion Measuring Device, 4 mod. DIN, connection via CT, with RS485 port

RISH PQM. Power Quality Monitor. Preliminary Datasheet subject to change without notice. Individual Harmonics measurement upto 56th Harmonics

Energy Management Modular Power Analyzers Type WM2-96

PEM353. Universal measuring device

Contents. Introduction and description Package contents Device identification PM Options... 80

UMG 103. UMG 103 Universal measurement device for DIN rails. GridVis Analysis software. Harmonics. Measurement accuracy 0.5.

emeter1 Single-phase energy meter emeter3 Three-phase energy meter User manual NO POWER & SIGNAL CABLES TOGETHER READ CAREFULLY IN THE TEXT!

VFSC9 ELECTRONIC SPEED CONTROLLER. Mounting and operating instructions

EM-72 Electricity Meters for Current Transformers

Modbus communication module for TCX2: AEX-MOD

LARSEN & TOUBRO LIMITED

INDUSTRIAL+COMMERCIAL ZMG400AR/CR, ZFG400AR/CR TECHNICAL DATA. IEC-specific data. Current. Measurement Accuracy. Measurement Behaviour.

SolarEdge Feed-in Limitation Application Note

ELECTRONIC METER MX2-A01E MX2-C01E MX2-C41E MX2-B41E MODBUS RTU Interface Specifications MDD-T0026

Multifunction network analyzer Q15U Q96U2L - Q96U4... Q15E Q96E MCU - MCUH Programmable transducer MCUU

DPF-MAC Auto power factor controller

SUPPLY NETWORK ANALYZER CVM-96 SERIES

EN61036 EN61268 CARLO GAVAZZI

Position Indicator model MFC-300/IP. Technical Manual. Licht

Multimeter 500CVD21 RTU500 series

This certificate must be used in conjunction with a certificate covering the product verification as required in Annex D or Annex F.

Power quality Harmonics up to 40th harmonic Unbalance, rotary field indication Distortion factor THD-U / THD-I

COUNTIS E25/E26 Three-phase active energy meter 63A direct M-BUS

E550 Series 2. Electricity Meters IEC/MID Industrial and Commercial ZMG400AR/CR. Technical Data

Hardware Manual. PCD3.F240/PCD2.F2400 LON interface module for TP/FT-10 channel. Hardware Manual PCD3.F240/PCD2.F2400, LON interface module

Energy Management Energy Analyzer Type EM24 DIN

E550 Series 2. Electricity Meters IEC/MID Industrial and Commercial ZMG310AR/CR. Technical Data

Energy Management. Type WM14-DIN Basic Version. How to order WM14-DIN AV5 3 D PGX. Type Selection. Input specifications. CptBSoft

SolarEdge Feed-in Limitation Application Note

Energy Management Energy Meter Type EM110

HVR. Lead Wire Length (H, mm)

DIRIS Ap RS485 JBUS/MODBUS COM. Systèmes de Coupure et de Protection Industrial Switching and Protection Systems ON 1

MID. Energy Management Energy Analyzer Type EM Product Description. How to order EM26 96 AV5 3 H O3 S1 PF A. Type Selection EM26 96

Transcription:

Data sheet www.sbc-support.com Single phase energy meter with Serial Modbus interface Energy meters with a Serial RS-485 Modbus interface allow direct reading of all relevant data, such as energy (total and partial), current, voltage, active and reactive power. Main features Single-phase energy meter, 230 VAC 50 Hz Direct measurement up to 32 A Display of active power, voltage and current Modbus RTU Interface to query the data Reactive power and cosφ available through interface Up to 247 meters can be connected to the Modbus Interface 7-digits display Lead seal possible with cap as accessory Accuracy class according to EN50470-3, accuracy class 1 according to IEC62053-21 Order Number Standard Version: D00A2A00 MID Version: D00A3A00 Sealing caps 4 104 7420 0 Technical data Precision class Operating voltage Mounting according to EN50470-3 1 according to IEC62053-21 230 VAC, 50 Hz Tolerance 20 % / +15 % Reference/maximal current Iref = 5 A, Imax = 32 A Starting/minimum current Ist = 20 ma, Imin = 0.25 A Power consumption Active 0.4 W Counting range 00'000.00 99'999.99 100'000.0 999'999.9 Pulses per kwh LC-Display Mounting On 35 mm rail, according to EN60715TH35 Terminal connections main circuit Conductor cross-section max. 6 mm2. Screwdriver Pozidrive no. 1, Slot no. 1 reak torque: 1.2 Nm Terminal connections control circuit Conductor cross-section max. 2.5 mm2. Screwdriver Pozidrive no. 0, Slot no. 1 reak torque: 0.5 Nm Insulation characteristics 4 kv / 50 Hz test according to VDE0435 for Energy Meter part 6 kv 1.2 / 50 µs surge voltage According to IEC255-4 2 kv / 50 Hz test according to VDE0435 for Interface 2000 Imp./kWh device protection class II Ambient temperature 25 +55 C Storage temperature 30 +85 C Environment Mechanical M2 Electromagnetic E2 Relative humidity 75 % without condensation EMC/interference immunity Surge voltage according to IEC61000-4-5 at main circuit 4 kv, at Modbus interface, 1 kv urst voltage according to IEC61000-4-4 at main circuit 4 kv, at Modbus interface 1 kv ESD according to IEC61000-4-2, contact 8 kv, air 15 kv

Dimension diagram Display elements, direct measurement Structure Ttotal (kwh) Tpart. (kwh) 2000 Imp/kWh I (A) T total (kwh) T part (kwh) Indicates the instantaneous power Indicates the voltage Indicates the current Indicates the total consumption Indicates the partial consumption. This value can be reset 2000 pulses/kwh Pulsates according to the amount of used power. Error indication (Line 1L/2L inverted) pulsating with 600/600 ms 2 www.sbc-support.com Energy meter with Serial Modbus interface Datasheet

Menu to display the value on LCD Start T total Total consumption Tpart. Partial consumption > 3 s > 3 s P Instantaneous power U Voltage > 3 s I Current > 2 s 20 s ack to Start ack to Start Datasheet Energy meter with Serial Modbus interface www.sbc-support.com 3

Wirings Diagram 5560 N Modbus over RS-485 serial line max. 1200 m L1 230 VAC 4 www.sbc-support.com Energy meter with Serial Modbus interface Datasheet

Technical data Modbus Protocol us system Transmission rate (bps) Transmission mode us cable Response time Modbus RTU according to IDA specification RS-485 Serial line 2400-4800-9600-19'200-38'400-57'600-115'200. The transmission aud rate is automatically detected Even parity: 8 data bits, 1 stop bit Odd parity: 8 data bits, 1 stop bit No parity: 8 data bits, 2 stop bits Twisted, shielded, 2 0.5 mm 2, 1200 m max. typ. 5 character times max. 60 ms The communication is ready 30 s after the Power On. Refresh Time for the Data is 5 s. Therefore the delay between reads of the same Data should be at least 5 s. The use of Energy meters in us with intensive communication can increase the data refresh time. 247 Devices can be connected to the Modbus. Over 128 Devices, a repeater should be used. The Interface don t have a terminal resistor, this should be provided external. For the following transmission rate change a restart of the counter is necessary: 2400 115'200. For a description of the used Registers please look at the Register Page. Data transmission Only «Read Holding Registers [03]/ Write Multiple Registers [16]» instructions are recognized. Up to 20 Registers can be read at a time. The device supports broadcast messages. In accordance with the Modbus protocol, a register R is numbered as R - 1 when transmitted. The device has a voltage monitoring system. In case of voltage loss, registers are stored in EEPROM (transmission rate, etc.) Exception Responses ILLEGAL FUNCTION [01]: The function code is not supported. ILLEGAL DATA ADDRESS [02]: The address of some requested registers is out of range or more than 20 registers have been requested. ILLEGAL DATA VALUE [03]: The value in the data field is invalid for the referenced register. Change the Modbus address direct on device In the menu, go for «U» Push long ( 3 s) «Adr» Push short address +1, push long address +10 Once the desired address is selected, wait to validate, till the root menu to come back Datasheet Energy meter with Serial Modbus interface www.sbc-support.com 5

Registers For double registers (4 5, 16 17, 28 29, 30 31) the high register is sent first (big-endian). Partial counter (30 31) can be reset by writing 0 in both registers in the same message. R Read Write Description Unit 1 X Firmware-Version Ex: 11 = FW 1.1 2 X Number of supported registers Will give 40 3 X Number of supported flags Will give 0 4 5 X audrate Ex: audrate High = 1 audrate Low = 49'664 1 65'536 + 49'664 = 115'200 bps 6 Not Used Will give 0 7 X Type / ASN function Will give «AL» 8 X Type / ASN function Will give «D1» 9 X Type / ASN function Will give «D5» 10 X Type / ASN function Will give «FD» 11 X Type / ASN function Will give «00» 12 X Type / ASN function Will give «Ax» x : 2 = Non MID x : 3 = MID 13 X Type / ASN function Will give «A0» 14 X Type / ASN function Will give «0» 15 X HW vers. Modif. Ex: 11 = HW 1.1 16 17 X Serial number Unique 32 bit serial number Low 18 X Serial number Unique 32 bit serial number High 19 Not Used Will give 0 20 Not Used Will give 0 21 Not Used Will give 0 22 X Status 0 = no Problem 1 = problem with last communication request 23 X Response timeout ms 24 X X 1) Modbus Address Range 1 247 25 X Error register 0 : No error; 1 : Error 26 Not Used Will give 0 27 Not Used Will give 0 28 29 X WT1 total Counter Energy Total Tariff 1 30 31 X X WT1 partial Counter Energy Partial Tariff 1 32 Not Used Will give 0 10 2 kwh (multiplier 0,01) Ex: WT1 total High = 13 WT1 total Low = 60'383 13 65'536 + 60'383 = 912'351 = 9123.51 kwh 10 2 kwh (multiplier 0,01) Ex: WT1 partial High = 13 WT1 partial Low = 60'383 13 65'536 + 60'383 = 912'351 = 9123.51 kwh 6 www.sbc-support.com Energy meter with Serial Modbus interface Datasheet

33 Not Used Will give 0 34 Not Used Will give 0 35 Not Used Will give 0 36 X URMS phase 1 Effective Voltage of Phase 1 37 X IRMS phase 1 Effective Current of Phase 1 38 X PRMS phase 1 Effective active Power of Phase 1 39 X QRMS phase 1 Effective reactive Power of Phase 1 V Ex: 230 = 230 V 10 1 A (multiplier 0,1) Ex: 314 = 31.4 A 10 2 kw (multiplier 0,01) Ex: 1545 = 15,45 kw 10 2 kvar (multiplier 0,01) Ex: 1545 = 15,45 kvar 40 X cos phi phase 1 10 2 (multiplier 0,01) Ex: 67 = 0,67 1) The Modbus Address register is not writable with a broadcast message. Datasheet Energy meter with Serial Modbus interface www.sbc-support.com 7

Saia-urgess Controls AG ahnhofstrasse 18 3280 Murten, Switzerland T +41 26 672 72 72 F +41 26 672 74 99 www.saia-pcd.com support@saia-pcd.com www.sbc-support.com P+P26/529 EN03 10.2013 Subjects to change without notice