Isolators A3/1.

Similar documents
Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160

Isolating Repeater Input Series 9163

09746E00. ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone Zone Division Ex i

Isolators A3/1.

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160 Rev. F

Binary Output Series 9175

Isolators A3/1. Vibration Transducer Supply Unit Series

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series

Isolators A3/1. Temperature Transmitter Field Circuit Non-Ex i Series

Binary Output without Power Supply Series 9176

06528E00. ATEX / IECEx NEC 505 NEC 506 NEC 500

3 Ex i Isolators. Temperature Transmitter without Output 0/ ma, with Limit Value Contact (Field Circuit Ex i) Type 9182/.

Isolators A3/1. Ex i Power Supply Field Circuit Ex i Series

3 Ex i Isolators. Temperature Transmitter with Output 0/ ma, without Limit Value Contact (Field Circuit Ex i) Type 9182/.0-5.

Fieldbus Isolating Repeater Series 9185/11

Analog Universal Module HART for Zone 2 Series 9468/33

3 Ex i Isolators. Switching Repeater with Power Relay (250 V / 4 A) Type 9170/ Type 9170/

Isolators Isolating Repeater Field Circuit Ex i ISpac 9165/ s Art. No

Digital Input Output Module for Zone 2 Series 9470/33

Digital Input Output Module for Zone 1 Series 9470/32

Digital Input Output Module for Zone 2 Series 9470/33

Temperature Input Module for Zone 1 Series 9482/32

Analog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/

Digital Input Module NAMUR Ex i / I.S. Inputs, 16 Channels for Zone 1 / Div. 1 Series 9470/22

Digital Input Module 24 V Ex n Inputs, 16 Channels Series 9471

Digital Input Output Module 24 V for Ex n Zone 2 Series 9472/35

Digital I/O Coupler (4-wire) Series 9413/21

Single-Channel Safety Barriers with Electronic Current Limitation Series 9004

Two-channel safety barriers Series 9002

Two-channel safety barriers Series 9002

Single-Channel Safety Barriers Series 9001

Remote I/O. 74 Remote I/O. Remote I/O System

Engineering Guideline. pac-carriers Type for Yokogawa Centum VP

Inductive sensor slot-type SI2-K08-AP7

2 Safety Barriers. Single-Channel Safety Barriers with Electronic Current Limitation Series 9004

Assembly. Front view. HiC2441. SL2 1b. Termination Board

Assembly. Front view. LED yellow: Relay output. LED red: LB/SC

Technical Information Barrier RB223

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

MACX MCR-EX-SL-RPSSI-I

Temperature Transmitter itemp RTD DIN rail TMT 127

Assembly. Front view. Parametrization interface. Power Bus

MACX MCR-EX-SL-RPSSI-I-UP(-SP)

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Temperature transmitter itemp PCP DIN rail TMT 121

SINEAX TI 807 Passive DC signal isolator. SINEAX TI 807 Passive DC signal isolator

SINEAX TI 807 Passive DC signal isolator

itemp HART DIN rail TMT112

0 2 1 â Ó. itemp HART TMT182. Technical Information

Signal conditioner - MACX MCR-UI-UI-NC

Assembly. Front view. Switch Power Rail

Digital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version

Digital temperature transmitter Model T15.H, head mounting version Model T15.R, rail mounting version

ISOLATING SWITCHING AMPLIFIERS POWER SUPPLIES

Temperature Measurement

Data Sheet KFD2-UFC-EX1.D. Supplied by. .com. Call us on +44 (0)

Technical Data. General specifications. Rated operating distance s n 3 mm

â itemp Pt100 TMT127 Technical information Pt100 transmitter for DIN rail mounting for high accuracy temperature monitoring

0 2 1 â Ó. itemp HART TMT182. Technical Information

Assembly. Front view. Switch Power Rail

Field indicator for current loops with HART communication Models DIH50, DIH52

Signal Beacon - LED Series 6162

Temperature transmitter itemp RTD DIN rail TMT 127

Analogue Temperature Transmitter Model T24.10, PC configurable, Head Mounting

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Temperature Measurement Transmitters for mounting in sensor head

Connection. Input EEx ia IIC. Sense. Fine tuning adjustment. Fine tuning amplifying. Amplifying. Adjustment. Output. Composition

Digital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting

Temperature Measurement Transmitters for mounting in sensor head

SINEAX B 811 Power Pack with additional Functions

D1072. SIL 2 Temperature Signal Converter, Duplicator, Adder/Subtractor DIN-Rail Models D1072S, D1072D. Front Panel and Features:

Technical Information RMA42

Temperature Measurement

SITRANS T measuring instruments for temperature

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 20 ms. 60 ms. 60 ms. Approx. 1.3 kg. Approx. 0.9 kg. Approx. 5.

Submersible pressure sensor For oils and fuels Model LF-1

Submersible pressure sensor For water and wastewater Model LW-1

MACX MCR-UI-UI-UP(-SP)(-NC)

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1.

â Ó itemp TC TMT128 Technical information DIN rail mounted Temperature Transmitter for Thermocouples (TC)

Trip amplifier, 1 channel

SINEAX V 624 Programmable Temperature Transmitter for RTD and TC inputs

RMA42. Technical Information

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. appmeas.co.uk +44 (0)

Assembly. Front view. Power Rail

OPTITEMP TT 10 C/R Technical Datasheet

Assembly. Front view. LED yellow: Relay output I. LED red: LB/SC channel I. LED yellow: Relay output II. LED red: LB/SC channel II

TR 104, TR 104-Ex Rail mounted Temperature Transmitters

SITRANS T measuring instruments for temperature

Resistance thermometer Model TR30, compact design

Temperature Measurement

JUMO dtrans T01 HART / T01T HART / T01 Junior / T01 Ex / T01 HART Ex Programmable 2-wire transmitter

BAR-ANT-N-N-EX. Antenna barrier for the hazardous area. Data sheet. 1 Description

Submersible pressure sensor For superior applications Model LF-1

Assembly. Front view. LED yellow: Relay output I. LED red: LB/SC channel I. LED yellow: Relay output II. LED red: LB/SC channel II

PRetrans Table of contents

SINEAX TV809, 1 channel Programmable Isolating Amplifier

MINI MCR-SL-UI-I-LP-NC

Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F

INSTRUCTION MANUAL. SIL 3 - SIL 2 Digital Output Loop/Bus Powered DIN-Rail Models D1040Q, D1041Q, D1042Q, D1043Q, D1040Q - D1041Q - D1042Q - D1043Q

Transcription:

> Compact limit value switch with 2 configurable limiting values and 4... 20 ma output > Suitable for 2-, 3-wire transmitters, 2-wire HART transmitters and ma sources > Intrinsically safe input [Ex ia] IIC > Open circuit / short-circuit monitoring and messaging > For use with up to SIL 2 (IEC 61508) www.stahl.de 11025E00 The transmitter supply unit with limit value contacts is used for intrinsically safe operation of 2- and 3-wires transmitters or for connection to intrinsically safe ma sources. Furthermore, the device gives the opportunity to compare the analogue signal with two adjustable limiting values. Exceeding the limiting values or falling below them is reported by the contacts. The transmitter supply unit can be easily parameterised by means of the ISpac Wizard software. ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone 0 1 2 20 21 22 Zone 0 1 2 20 21 22 Division 1 2 1 2 1 2 Installation in x x Installation in x x Installation in x x x WebCode 9162A Isolators /1

max. connectable capacitance C o IIC 90 nf 90 nf max. connectable inductance L o IIC 2.3 mh 2.3 mh PFD AVG at T [Proof] 1 year 1.30 x 10-4 2.23 x 10-4 1.29 x 10-4 Transmitter Supply Unit with Limit Contact Selection Table Version Channels Input Output Limit Order number Art. no. contact Transmitter supply unit with limit contact 1 4... 20 ma with HART 4... 20 ma with HART 2 NO 9162/13-11-14s 238251 Note The order numbers listed in the table are for devices equipped with screw terminals. For devices equipped with springclamp terminals, replace the ending "s" for screw terminals with "k" for spring clamp terminals. Explosion Protection Global (IECEx) Gas and dust IECEx BVS 15.0013X Ex na nc [ia Ga] IIC T4 Gc [Ex ia Da] IIIC Europe (ATEX) Gas and dust Certifications and certificates Certificates Ship approval Safety data When connecting transmitters BVS 15 ATEX E018X E II 3 (1) G Ex na nc [ia Ga] IIC T4 Gc E II (1) D [Ex ia Da] IIIC IECEx, ATEX, India (PESO), Canada (cfm), Kazakhstan (TR), Russia (TR), USA (FM), Belarus (TR) DNV GL 2-wire transmitter 3-wire transmitter max. voltage U o 27 V 27 V max. current I o 87.9 ma 88.3 ma max. power P o 574 mw 574 mw internal capacitance C i negligible negligible internal inductance L i negligible negligible Safety-related maximum voltage 253 V 253 V When connecting current max. output voltage U o 4.1 V sources max. output current I o ~ 0 ma Max. output power P o ~ 0 mw max. connectable voltage U i 30 V max. connectable current I i 100 ma internal capacitance C i negligible internal inductance L i negligible Further parameters Installation in Zone 2 and in the safe area Further information see respective certificate and operating instructions Functional safety (IEC 61508) Test report Exida STAHL 13/12-013 R029 Max. SIL 2 Output 4... 20 ma Limit contact Limit contacts in series Safe Failure Fraction SFF 93 % 90 % 94 % MTBF 118 years 116 years 116 years /2 Further information Isolators 2 years 2.43 x 10-4 4.19 x 10-4 2.38 x 10-4 5 years 5.81 x 10-4 1.01 x 10-3 5.67 x 10-4 For further information, see Safety manual and test reports.

Technical Data Electrical data Auxiliary power Nominal voltage U N 24 V DC Voltage range 18... 31.2 V Residual ripple ( 3.6 V SS Nominal current at U N, 20 ma 85 ma Power consumption at U N, 20 ma 2 W Power dissipation at U N, 1.5 W R L = 250 Ω Polarity reversal protection yes Operation indication LED green "PWR" Undervoltage monitoring yes (no faulty devices / output states) Galvanic separation Test voltages acc. to standard EN 60079-11 Ex i input to output 1.5 kv AC Ex i input to auxiliary power 1.5 kv AC Ex i input to 1.5 kv AC error message contact Ex i input to limit contact 1.5 V AC acc. to standard EN 50178 Output to auxiliary power 350 V AC Output to limit contact 350 V AC Error message contact to 350 V AC auxiliary power and outputs Ex i input Input signal 4... 20 ma with HART Functional range 2... 22 ma Max. input current for 50 ma ma sources Supply voltage for transmitter ) 16 V at 20 ma (T Amb > - 10 C, T Amb < -10 C: U S - 0.2 V / 10K) Residual ripple of supply voltage ( 25 mv eff Open-circuit voltage ( 26 V Short-circuit current ( 35 ma Input resistance > 250 Ω (AC impedance HART) Input resistance for ma sources 30 Ω Communication signal bidirectional HART transmission, 0.5... 10 khz (in 2-wire transmitters) Output Output signal 4... 20 ma with HART Load resistance R L 0... 600 Ω (terminal 1+ / 2-) Functional range 2... 22 ma Residual ripple ( 40 μa eff Communication signal bidirectional HART transmission, 0.5... 10 khz Signal delay < 30 ms Signal rise, signal drop < 45 ms Limiting values Configuration using ISpac Wizard (V3.04.00 and following) Message 2 NO Switching voltage ( ± 30 V Switching current (resistive load) ( 170 ma Switching current, max. 100 ms ( 750 ma Switch on resistance ( 2.5 Ω (typical < 1 Ω ) Reclosing lockout Reset using the DIP switch or "Power-Off" (configurable) Switching delay < 80 ms Switch-back delay < 100 ms Error detection Ex i input Wire breakage < 3.6 ma Short circuit > 21 ma Behaviour of the output = Input signal Message of line fault and auxiliary power failure - contact (30 V / 100 ma) closed to earth in case of error - pac-bus, potential-free contact (30 V / 100 ma) Isolators /3

Technical Data Electrical data Error limits Accuracy, typical data expressed as % of calibrated span (20 ma) at U N, 23 C Deviation ( 0.2 % Temperature effect ( 0.1 % / 10K Electromagnetic compatibility Tested under the following standards and regulations: EN 61326-1 (use in industrial environment) Ambient conditions Ambient temperature Single device -40... +70 C Group assembly -40... +60 C The installation conditions affect the ambient temperature. Observe the "Cabinet installation guide". Storage temperature -40... +80 C Relative humidity (no condensation) ( 95 % Use at the height of < 2000 m Electrical connection Connection diagram Hazardous area Safe area Division 1 Zone 0 / 1 pac-bus Division 2 Zone 2 passive Field device ISpac Isolator Control system 13620E01 Technical Data Mechanical data Connection Single-wire connection - rigid - flexible - flexible with core end sleeves (without / with plastic sleeve) two-wire connection - rigid - flexible - flexible with core end sleeves Screw terminals 0.25... 2.5 mm 2 0.2... 1 mm 2 0.2... 1.5 mm 2 0.25... 1 mm 2 Spring clamp terminals 0.25... 2.5 mm 2 0.5... 1 mm 2 Weight approx. 160 g Mounting type on top hat rail (NS35/15, NS35/7.5) or in pac-carrier Mounting orientation horizontal or vertical Enclosure IP30 Terminals IP20 Enclosure material PA 6.6 Fire resistance (UL-94) V0 /4 Isolators

Dimensional drawings (all dimensions in mm [inches]) Subject to alterations X 99 [ 3, 90 ] 17,6 [0,69] Dimension X Screw terminals 108 mm / 4.25 Spring clamp terminals 128 mm / 5.04 122 [ 4, 80 ] 114,5 [ 4, 51 ] Accessories and Spare Parts Designation Description Order number Transparent cover yellow, transparent. 200914 Clear marking of the device for SIL applications. (Packaging unit: 10 pieces) Parameterising set - ISpac - Wizard The software serves for commissioning, configuring and diagnosing the ISpac isolators Series 9146, 9162 and 9182. For further information, see operating instructions. Form of delivery: CD-ROM; parameterising software incl. parameterising cable / adaptor 9199/20-02 09685E00 System requirements: IBM compatible PC with Windows 2000, XP, Vista, Windows 7&8 CD-ROM drive RS 232 C interface RS 232 / USB adaptor Isolators /5

Customer specific parameterisation 17085E02 We reserve the right to make alterations to the technical data, dimensions, weights, designs and products available without notice. The illustrations cannot be considered binding. /6 Isolators