ATLAS Corneal Topography System

Similar documents
(495) (495)

Refractive Power / Corneal Analyzer. OPD-Scan III

OCULUS Keratograph 4. Topographer. We focus on progress

Optical Path Difference Scanning System OPD-Scan II ARK-10000

OCULUS Easygraph. Topographer. We focus on progress

OCULUS Easygraph. So Small and Yet a Topographer. Small, but Efficient As a Big One. All Important Parameters at a Glance

Sirius TOMOGRAPH AND CORNEAL TOPOGRAPHER


Headline. IOLMaster. Subline. The gold standard in biometry

MEL 80 Excimer Laser. When you want to see better performance

THE BEST OF BOTH WORLDS Dual-Scheimpflug and Placido Reaching a new level in refractive screening

Wave Front Topography. ReSeeVit Evolution Topography Module for Modi Topographer

OCULUS Keratograph 5M Topographer

CLARUS 500 from ZEISS HD ultra-widefield fundus imaging

CLARUS 500 from ZEISS HD ultra-widefield fundus imaging

The Aberration Structure of the Keratoconic Eye

An Interesting Use of Bausch and Lomb s KeraSoft IC Lens

Headline. SL 130 Slit Lamp. Subline. Maximum quality for optimum performance

OCULUS Pentacam AXL Always an Axial Length Ahead

EDoF IOL. ZEISS AT LARA 829MP Next generation Extended Depth of Focus Intraocular Lens. NEW EDoF IOL from ZEISS

Wave-Front Analyzer KR-1W

The First True Color Confocal Scanner

Optical Connection, Inc. and Ophthonix, Inc.

Aberrometry in Clinical Practice

The First True Color Confocal Scanner on the Market

ClearKone Restoring vision. Changing lives.

Impressive Wide Field Image Quality with Small Pupil Size

The First True-Color Wide-Field Confocal Scanner

AT LISA tri 839MP and AT LISA tri toric 939MP from ZEISS The innovative trifocal IOL concept providing True Living Vision to more patients

How do I acquire a high-quality scan on my CIRRUS HD-OCT? (Part 1 of 3 iris alignment)

FOR PRECISE ASTIGMATISM CORRECTION.

FITTING GUIDE PRACTITIONER S ROSE K2 KC ROSE K2 NC ROSE K2 IC ROSE K2 PG NIPPLE CONE IRREGULAR CORNEA POST GRAFT

NEW. AT LISA tri 839MP and AT LISA tri toric 939MP from ZEISS The innovative trifocal IOL concept providing True Living Vision to more patients

10/25/2017. Financial Disclosures. Do your patients complain of? Are you frustrated by remake after remake? What is wavefront error (WFE)?

KERATOCONUS. In the most advances cases, the corneal deformation can be easy observed fig. 1. Fig. 1

VISULAS Trion. Treatment flexibility to the power of three. Multicolor Photocoagulation Laser

REF KERATRON. The Standard in Corneal Topography

Rediscover quality of life thanks to vision correction with technology from Carl Zeiss. Patient Information

Optics of Wavefront. Austin Roorda, Ph.D. University of Houston College of Optometry

Patient information. Your options for cataract treatment Enjoy clear vision at all distances with multifocal IOLs

DesiGneD and ManUFaCTUreD in italy The sharpest vision.

Auto Ref/ Keratometer / Auto Refractometer ARK-1 / AR-1

Fitting Manual Use with kerasofttraining.com

What is Wavefront Aberration? Custom Contact Lenses For Vision Improvement Are They Feasible In A Disposable World?

Corneal Asphericity and Retinal Image Quality: A Case Study and Simulations

THE SHARPEST VISION. DESIGNED AND MANUFACTURED IN ITALY

Corporate Perspective Alcon Unanswered Technical Challenges that Still Need to be Overcome

FITTING GUIDE. Duette Hybrid Contact Lenses Duette Progressive Hybrid Contact Lenses - Center Distance - Center Near

NIDEK ADVANCED VISION EXCIMER LASER SYSTEM

What you should know about LASIK and Femto-LASIK Understanding Laser Vision Correction. Patient information

Keratoconus contact lenses

The War against Corneal Warpage

OCULUS Keratograph 5M Topographer

Paragon CRT Dual Axis Quick Reference Guide

Ron Liu OPTI521-Introductory Optomechanical Engineering December 7, 2009

Principles and clinical applications of ray-tracing aberrometry (Part II)

Auto Ref/ Keratometer / Auto Refractometer ARK-1 / AR-1

Performance Meets Simplicity

Introduces The OK -EX -Total Tear Layer Control- Features. What is the OK-EX? Multi-Axis Toric Option.

INSTRUCTION MANUAL WAVE-FRONT ANALYZER. KR-1W Viewer. Version TOPCON Corporation

Irregular Cornea. ROSE K2 Soft TM. Practitioner s Fitting Guide

INSTRUCTIONS FOR USE CORNEAL ANALYZER CA-800 CORNEAL ANALYZER

Fitting Manual Use with

Auto Ref/ Keratometer / Auto Refractometer ARK-1 / AR-1

Infra Red Interferometers

PROCEEDINGS OF SPIE. Measurement of low-order aberrations with an autostigmatic microscope

Soft CL Multifocals Design and Fitting. Soft Multifocal Lens Designs. Issues Surrounding Multifocals. Blur Interpretation. Simultaneous Vision Designs

ULTRA-THIN CUSTOM CONTACT LENS FOR KERATOCONUS AND IRREGULAR CORNEAS

ULTRA-THIN SPECIALIST CONTACT LENS FOR KERATOCONUS AND IRREGULAR CORNEAS

Quality Testing of Intraocular Lenses. OptiSpheric IOL Family and WaveMaster IOL 2

Quality Testing of Intraocular Lenses. OptiSpheric IOL Family and WaveMaster IOL 2

Customized intraocular lenses

Author Contact Information: Erik Gross VISX Incorporated 3400 Central Expressway Santa Clara, CA, 95051

NOW. Approved for NTIOL classification from CMS Available in Quar ter Diopter Powers. Accommodating. Aberration Free. Aspheric.

Chapter 20 Human Vision

WaveMaster IOL. Fast and accurate intraocular lens tester

Trouble Shooting Guide for Ortho-K lenses

Cardinal Points of an Optical System--and Other Basic Facts

Assessing Visual Quality With the Point Spread Function Using the NIDEK OPD-Scan II

NIMO TR1504 CONTACT US. Lambda-X s.a. Av. Robert Schuman 102 B-1400 NIVELLES Belgium

Auto Ref / Keratometer ARK-560A / 530A / 510A

Digitalise your Practice with Ease, Speed and Comfort. NEW from Gendex!

WaveMaster IOL. Fast and Accurate Intraocular Lens Tester

The soft approach to RGPs

Difrotec Product & Services. Ultra high accuracy interferometry & custom optical solutions

HRK-7000 / HRK-7000A Auto Ref-Keratometer

CA-800 Corneal Analyzer

Optical Biometer AL-Scan

Choices and Vision. Jeffrey Koziol M.D. Thursday, December 6, 12

CA-800 Corneal Analyzer

Spectroradiometer CS-2000/2000A. The world's top-level capability spectroradiometers make further advances with addition of second model to lineup.

Spectroradiometer CS-2000/2000A. The world's top-level capability spectroradiometers make further advances with addition of second model to lineup.

Optical Biometer AL-Scan

Unique Aberration-Free IOL: A Vision that Patients

AUTO REF / KERATOMETER ARK-560A / 530A / 510A

PREMIUM LENSES WITH VARIABLE BASE CURVE

Straightforward Vestibular testing

Sets distance refraction. Moves camera forward / backward. Moves camera up / down. Moves camera left / right. Starts image acquisition (HRT 3 only)

ERK-9000 Auto Ref/Kertometer

Explanation of Aberration and Wavefront

Transcription:

ATLAS Corneal Topography System Simply accurate for maximum productivity Model 9000

The New ATLAS Take your practice to the next level Carl Zeiss Meditec has taken the world s leading corneal topography system 1 and made it better. The ATLAS System delivers the clinical accuracy essential to today s eye care practice, now in a more powerful and easier to use platform. With applications including contact lens fitting, pathology detection and management, and selection of aspheric IOLs, the new ATLAS System is the right choice for reliable real-world results, every time, from virtually any operator. Superior Performance Designed for How You Practice Compact, all-in-one system, now easier to use and more efficient Improved repeatability and reliability Compatible with your existing ATLAS data From Carl Zeiss Meditec, with more than a decade of experience in corneal topography Elevate Your Practice with ATLAS The next-generation ATLAS System provides new tools and superior data acquisition and analysis to set your practice apart. From increasing patient satisfaction, to gaining greater clinical insight, to improving overall workflow, the ATLAS System can take your practice to new heights. 1- Marketscope, The Surgical and Office Based Diagnostic Equipment Market, April 2006

Proprietary Technologies Deliver Superior Accuracy The ATLAS System has been proven to deliver the clinical accuracy that your practice requires. The all-in-one system combines a suite of unique technologies and is simple and efficient for virtually any operator to use. The result is a new level of confidence in every exam and for every patient. Proven Placido Disk Technology Placido Rings Cone of Focus Corneal Surface Patented Cone-of-Focus Alignment System and Arc-Step Algorithm deliver sub-micron elevation accuracy 22-ring Placido disk optimized to avoid ring crossover, which means reliable results for a wide range of patients Long, comfortable 70 mm working distance minimizes focusing error found in small cone systems Triangulation with the Cone-of-Focus, Placido rings, and corneal surface delivers superior accuracy SmartCapture Image Analysis Helps Your Staff Get it Right the First Time SmartCapture analyzes 15 digital images per second during alignment and automatically selects the highest quality image Next-generation image processing provides more repeatable, reliable results, even in difficult cases Less dependence on operator technique means greater efficiency and fewer repeat exams SmartCapture makes image acquisition easy Ergonomic Design Ideally Suited for You and Your Patient Unique chinrest positions patient for easy image capture and wide peripheral coverage and automatically detects OD/OS Non-visible Placido ring illumination increases corneal coverage and patient comfort Compact system with integrated computer makes examination effortless

Intuitive Analysis and Reporting Color Scale Customize colors and scales for detailed corneal assessments Topography Map Display as curvature, elevation, corneal wavefront, even image simulations. Landmarks such as corneal apex, pupil contour, and pupil center help explain the impact on visual acuity Data Automatically display preferred parameters such as simulated keratometry, shape factor, eccentricity, and HVID (white to white) Cursor Value Obtain the exact value at any point on the map Versatility That Is Visible Flexible, customizable displays provide instant insight into corneal curvature, shape, and visual function for improved practice efficiency. OD/OS Comparison Quickly assess both eyes for corneal health and refraction. Automatic Pupillometry and HVID Measurement Enhance contact lens fitting and refractive surgery planning with scotopic and photopic pupil images and HVID. Corneal Wavefront Overview Educate patients about higher-order aberrations and simulate visual acuity. Corneal Wavefront Zernike Analysis Measure corneal spherical aberration to optimize the selection of aspheric IOLs.

Gain Clinical Insight and Confidence Track corneal health for improved patient care 1. Axial map reveals inferior steepening and corneal warpage from years of wearing an improperly fit RGP contact lens with a highly aspheric back surface. 2. Image simulation displays higher-order corneal aberrations and confirms patient s complaints of severe spectacle blur. Case Example: Corneal Warpage Rehabilitation 3. The cornea was allowed to normalize over approximately 4 months and returned to a normal appearing astigmatic shape. 4. Image simulation shows the improvement in visual acuity with a reduction in higherorder aberrations. Screen for improved pathology detection and management 1. Axial map reveals a displaced corneal apex and inferior steepening, which standard keratometry at 3 mm would have missed. 3. Irregularity map, relative to a best-fit ellipsoid, highlights surface irregularities that may limit bestcorrected visual acuity. 2. Elevation map shows a 29 micron protrusion above a best-fit reference sphere. Case Example: Suspect Keratoconus 4. Mean Curvature map eliminates corneal astigmatism, highlighting underlying features, such as this cone peak.

ATLAS Model 9000 When patients entrust you with their eyesight, their vision and your expertise converge. ATLAS from Carl Zeiss Meditec empowers you with the most intuitive, advanced diagnostic solution. Along with our dedication to clinical and technical excellence, we offer world-class training, on-site support and ongoing educational opportunities. Partner with Zeiss for maximum productivity. Technical Specifications Working Distance Field of View Placido Rings Illumination Source Optics Curvature HVID (white to white) Pupillometry Views Presentation Displays Optional Software 2 Computer Dimensions/Weight (Instrument only) Electrical Measurement Range Accuracy Reproducibility Measurement Range Resolution Acquired Images Measurement Range Resolution 70 mm 17 mm X 14.5 mm 22 (18 superiorly, 22 inferiorly) Non-visible infrared (950 nm) LED Digital CMOS camera with 1280x1024 pixel resolution 15 to 95 D (3.5 to 22.5 mm) ± 0.05 D (± 0.01 mm) 1 ± 0.10 D (± 0.02 mm) 1 10.0 to 14.0 mm 0.1 mm Scotopic and photopic (700 nm) 0.5 to 11.0 mm 0.1 mm Axial Curvature Tangential Curvature Elevation (Best-Fit Sphere) Irregularity (Best-Fit Ellipsoid) Videokeratoscopic (Rings, Scotopic, Photopic) Keratometry Refractive Power Mean Curvature Corneal Wavefront Image Simulation Point Spread Function (PSF) Modulation Transfer Function (MTF) Single View Overview OD/OS Comparison Difference Trend with Time Custom PathFinder II Corneal Analysis Software MasterFit II Contact Lens Software ATLAS Review Software Windows XP Professional Pentium M Processor Internal storage: up to 35,000 exams CD-RW/DVD-ROM 3 Ethernet, 2 USB 2.0 ports Integrated 12.1 color flat panel display 52 L x 37 W x 50 H (cm) 39 lbs. (17.7 kg) 100-240V~: 50/60Hz, 2-1A ATL.1587 SAP 000000-1502-420 2007 Carl Zeiss Meditec, Inc. All rights reserved. Specifications subject to change. Printed in USA. 0907 5M NOTE: All technical specifications are subject to change without notice. Windows is a registered trademark of Microsoft Corporation. Pentium is a registered trademark of Intel Corporation. 1- To one standard deviation on a properly calibrated 42.51 D (7.94 mm) test object. 2- Available with ATLAS Software version 2.0 Carl Zeiss Meditec AG Phone: +49 3641220-333 Carl Zeiss Meditec Inc. Phone: +1 925 557 4100 Goeschwitzer Str. 51-52 Fax: +49 3641220-282 5160 Hacienda Drive Fax: +1 925 557 4101 07745 Jena info@meditec.zeiss.com Dublin, CA 94568 info@meditec.zeiss.com Germany www.meditec.zeiss.com USA www.meditec.zeiss.com