Modeling of overhead transmission lines with line surge arresters for lightning overvoltages. Poland

Similar documents
Analysis of lightning performance of 132KV transmission line by application of surge arresters

The Many Uses of Transmission Line Arresters

Introduce system protection relays like underfrequency relays, rate of change of frequency relays, reverse - power flow

2000 Mathematics Subject Classification: 68Uxx/Subject Classification for Computer Science. 281, 242.2

New Modeling of Metal Oxide Surge Arresters

PREVENTING FLASHOVER NEAR A SUBSTATION BY INSTALLING LINE SURGE ARRESTERS

Analysis of MOV Surge Arrester Models by using Alternative Transient Program ATP/EMTP

Effect of High Frequency Cable Attenuation on Lightning-Induced Overvoltages at Transformers

Parameters Affecting the Back Flashover across the Overhead Transmission Line Insulator Caused by Lightning

The Influence of Atmospheric Overvoltages on High-Voltage SF 6. Substations

Modeling insulation in high-voltage substations

Effect of Surge Arrester on Overhead Transmission Lines as Shield against Over Voltage

High voltage engineering

Lightning Flashover Rate of an Overhead Transmission Line Protected by Surge Arresters

Maximum Lightning Overvoltage along a Cable due to Shielding Failure

Effective Elimination Factors to the Generated Lightning Flashover in High Voltage Transmission Network

Computation of Lightning Impulse Backflashover Outages Rates on High Voltage Transmission Lines

Effect of Shielded Distribution Cables on Lightning-Induced Overvoltages in a Distribution System

B2-301 IMPROVING DOUBLE CIRCUIT TRANSMISSION LINE RELIABILITY THROUGH LIGHTNING DESIGN

LIGHTNING OVERVOLTAGES AND THE QUALITY OF SUPPLY: A CASE STUDY OF A SUBSTATION

Modeling for the Calculation of Overvoltages Stressing the Electronic Equipment of High Voltage Substations due to Lightning

Lightning performance of a HV/MV substation

Simulation of Short Circuit and Lightning Transients on 110 kv Overhead and Cable Transmission Lines Using ATP-EMTP

INSTALLATION OF LSA ON A 400 KV DOUBLE-CIRCUIT LINE IN RUSSIA

ABSTRACTS of SESSION 6

The relationship between operating maintenance and lightning overvoltage in distribution networks based on PSCAD/EMTDC

Utility System Lightning Protection

Lightning current field measurement on a transmission line, comparison with electromagnetic transient calculations

Simulation and Analysis of Lightning on 345-kV Arrester Platform Ground-Leading Line Models

Hazard of Induced Overvoltage to Power Distribution Lines Jiang Jun, Zhao Rui, Chen Jingyang, Tian Hua, Han Lin

Insulation Coordination Fundamentals Where Arrester and Insulator Characteristics Meet

When surge arres t ers are installed close to a power transformer, overvoltage TRANSFORMER IN GRID ABSTRACT KEYWORDS

Lightning Protection of Distribution Substations by Using Metal Oxide Gapless Surge Arresters Connected in Parallel

Lightning Overvoltage Performance of 110 kv Air-Insulated Substation

X International Symposium on Lightning Protection

TECHNICAL NOTE 2.0. Overvoltages origin and magnitudes Overvoltage protection

Simulation of Lightning Transients on 110 kv overhead-cable transmission line using ATP-EMTP

The Analysis Results of Lightning Overvoltages by EMTP for Lightning Protection Design of 500 kv Substation

Electric Stresses on Surge Arrester Insulation under Standard and

A SIMPLIFIED LIGHTNING MODEL FOR METAL OXIDE SURGE ARRESTER. K. P. Mardira and T. K. Saha s: and

A Study on Lightning Overvoltage Characteristics of Grounding Systems in Underground Distribution Power Cables

GIS Disconnector Switching Operation VFTO Study

Lightning Performance Improvement of 115 kv and 24 kv Circuits by External Ground in MEA s Distribution System

Comparison between Different InstallationLocations of Surge Arresters at Transmission Line Using EMTP-RV

OVERVOLTAGE PROTECTION OF POLE MOUNTED DISTRIBUTION TRANSFORMERS

Including Surge Arresters in the Lightning Performance Analysis of 132kV Transmission Line

Simplified Approach to Calculate the Back Flashover Voltage of Shielded H.V. Transmission Line Towers

Earthing of Electrical Devices and Safety

EXPERIMENTAL ISSUES OF OVERVOLTAGE COORDINATION

Topic 6 Quiz, February 2017 Impedance and Fault Current Calculations For Radial Systems TLC ONLY!!!!! DUE DATE FOR TLC- February 14, 2017

The Effect of Lightning Parameters on Induced Voltages Caused by Nearby Lightning on Overhead Distribution Conducting Line.

Session Four: Practical Insulation Co-ordination for Lightning Induced Overvoltages

Considerations for Choosing a Switching Converter

CHOICE OF MV FEEDER BIL TO MAXIMIZE QOS AND MINIMIZE EQUIPMENT FAILURE

Tab 8 Surge Arresters

Substation Insulation Coordination Study

Study of Tower Grounding Resistance Effected Back Flashover to 500 kv Transmission Line in Thailand by using ATP/EMTP

Computer Based Model for Design Selection of Lightning Arrester for 132/33kV Substation

Analysis of current distribution among long-flashover arresters for 10 kv overhead line protection against direct lightning strikes

The impact of distributed generation to the lightning protection of modern distribution lines

CONTENTS. 1. Introduction Generating Stations 9 40

Lightning transient analysis in wind turbine blades

Great Northern Transmission Line: Behind the (Electrical) Design

University of Zagreb Faculty of Electrical Engineering and Computing

SWITCHING OVERVOLTAGES IN A 400-KV CABLE SYSTEM

Research on Lightning Over-voltage and Lightning Protection of 500kV. HGIS Substation

Protection against unacceptable voltages in railway systems

A Study on Ferroresonance Mitigation Techniques for Power Transformer

ArresterFacts 024. Separation Distance for Substations. ArresterFacts 024 Separation Distance for Substations. September 2014 Rev 7 Jonathan Woodworth

Journal of Asian Scientific Research SUBSTATION PROTECTION AND THE CLIMATIC ENVIRONMENT OF NIGER DELTA. John Tarilanyo Afa

ABSTRACT 1 INTRODUCTION

Lightning and Lightning Arrester Simulation in Electrical Power Distribution Systems

MODIFICATION OF THE ARRESTER ARRANGEMENT WHEN CONVERTING THE METHOD OF NEUTRAL TREATMENT

Influence Of Lightning Strike Location On The Induced Voltage On a Nearby Overhead Line

Calculation of Transient Overvoltages by using EMTP software in a 2-Phase 132KV GIS

Estimating BFOR on HV Transmission Lines Using EMTP and Curve of Limiting Parameters

MARCEL A. ARAÚJO, ROGÉRIO A. FLAUZINO, OURESTE E. BATISTA, LUCAS A. MORAES

Lightning overvoltage and protection of power substations

Secondary Arresters. Figure 1. Type L secondary surge arrester rated 175 Vac, 125 Vdc.

DEPARTMENT OF EEE QUESTION BANK

HIGH VOLTAGE Insulation Coordination

A Case Study on Selection and Application of Lightning Arrester and Designing its Suitable Grounding Grid

Performance of Surge Arrester to Multiple Lightning Strokes on Nearby Distribution Transformer

Distribution Transformer Random Transient Suppression using Diode Bridge T-type LC Reactor

APPLICATION OF LONG FLASHOVER ARRESTERS FOR IMPROVEMENT OF LIGHTNING PROTECTION AND OPERATING VOLTAGE RELIABILITY OF DISTRIBUTION LINES

Tab 2 Voltage Stresses Switching Transients

Prediction of Transient Transfer Functions at Cable-Transformer Interfaces

EMC Philosophy applied to Design the Grounding Systems for Gas Insulation Switchgear (GIS) Indoor Substation

Electrical Power and Energy Systems

Evaluating the Response of Surge Arresters

Transmission Line Transient Overvoltages (Travelling Waves on Power Systems)

Energy Division. Bowthorpe LV/MV Surge Arresters

Transmission of Electrical Energy

International Journal of Advance Engineering and Research Development. Analysis of Surge Arrester using FEM

The Lightning Event. White Paper

INTERNATIONAL STANDARD

SURGE PROPAGATION AND PROTECTION OF UNDERGROUND DISTRIBUTION CABLES

Lightning Performance of Transmission Lines with Tall Sections

Fatima Michael College of Engineering & Technology

Reducing the magnetizing inrush current by means of controlled energization and de-energization of large power transformers

Transcription:

Application of Line Surge Arresters in Power Distribution and Transmission Systems COLLOQUIUM Cavtat 2008 Modeling of overhead transmission lines with line surge arresters for lightning overvoltages M. JAROSZEWSKI *, J. POSPIESZNA *, P. RANACHOWSKI **, F. REJMUND ** * Wroclaw University of Technology, Institute of Electrical Engineering Fundamentals ** Polish Academy of Sciences, Institute of Fundamental Technological Research Poland SUMMARY Lightning is one of the most significant source of overvoltages in overhead transmission lines. The lightning overvoltages could lead to failure of the devices connected to the transmission line. A fundamental constraint on the reliability of an electrical power transmission system is the effectiveness of its protective system. The role of the protective system is to safeguard system components from the effects of electrical overstress. Surge arresters are an important means of lightning protection in distribution systems. Therefore, it is necessary to analyze influence of such overvoltages in order to applying the line surge arrester for improving the reliability of transmission line system. The method used to analyze the increase in voltage due to lightning was done by using the ATP/EMTP software This paper is aimed at analyzing the lightning performance improvement of a transmission line after installing line surge arresters. KEYWORDS overvoltage, arrester, simulation maciej.jaroszewski@pwr.wroc.pl

OVERVIEW In spite of protection of distribution lines by shield wires, they are still exhibit to lightning caused interruptions by shielding failures and backflashes. With effective shielding, it is possible to minimize direct strokes to the phase conductors, but this does not necessarily mean that the line will have satisfactory lightning performance. Shielding failures occur when the lightning stroke does not terminate on the tower or shield wire, but on the phase conductor instead. If the travelling wave - generated at the stricken point - is of sufficient magnitude, it will cause an insulator flashover. This flashover will result in a service interruption. Strokes to either a shield wire (or strokes to pole) or a phase conductor. can produce a flashover if the backflash overvoltage exceeds the insulator strength. The stroke current induces voltages in the phase conductor. The voltages induced in the phase conductors is a function of time, footing resistance and structure geometry. The voltage stress on the line insulation is equal to the difference between the structure voltage at the insulator attachment point and the induced voltage in the phase conductor. If the voltage stress across the line insulation exceeds the flashover voltage of the insulator, a flashover will occur [1]. The resulting backflash has a very fast rate of rise. There is evidence that these rapidly rising waves may be responsible for substation transformer failures, even where metal-oxide arresters are used in the substation [2]. The metal-oxide surge arresters use nonlinear metal-oxide varistors having a high impedance at system voltage. When a high voltage surge (such as from lightning) is impressed on the surge arrester, the impedance of the metal-oxide varistors drops dramatically. The metal-oxide surge arrester is connected electrically in parallel with the line insulation. The metal-oxide surge arrester limits the surge voltage across the line insulation by going into conduction at a voltage below the flashover voltage of the line insulation. After the surge arrester has successfully discharged the lightning surge, the voltage across the arrester returns to the line-to-ground value. The arrester is only in conduction for the duration of the lightning stroke. This event is of too short duration to be detected by relaying methods. Therefore, the operation of the surge arrester will not result in an interruption. Strokes to phase conductor are limited in magnitude to the maximum shield failure current, which for the usual line is between 5 and 15 ka. These shield failure currents plus currents from subsequence strokes produce arrester energies that normally exceed the energy caused by strokes to shield wire. However, in general, the energy discharged through the arrester is within the energy capability of the arrester [3]. Lightning interruptions are becoming a major problem for electric utilities. The application of surge arresters provides better performance than overhead shield wires. The use of surge arresters gives up significant improvement in lightning performance over use of overhead shield wire alone. In addition to improved lightning performance, the use of polymer-housed surge arresters insulators have other benefits, like [2]: reduced pole top weight, reduced line structure heights, reduced line losses due to elimination of shield wire, reduced magnetic fields due to closer phase spacing. 2

The use of surge arresters on existing shielded construction with higher footing resistances can reduce lightning caused interruptions. For footing resistances of 100 ohms, the addition of the surge arresters reduces the interruption rate by 34 percent over shield wire alone [2]. SIMULATION PROCESS The most simple MOV model, presented in Figure 1, corresponds to the physics of metal-oxide disc [4].The resistance R corresponds to the nonlinear resistance of the intergranular layers, where the resistivity ρ changes in the range from 10 5 Ωm to 0.01 Ωm. The resistance R Z is the resistance of the ZnO grains with low resistivity 0.01 Ωm. The inductance L is inductance of the MOV and is determined by the current flow path. Frequency dependence is obtained with the serial inductance L, providing that the voltage peak across the MOV occurs before the current peak. The inductance L also provides different amplitudes of the clamping voltage for different surge current amplitudes and rates of rise. The major disadvantage of this model is that model parameters must be tuned for each current waveform shape and amplitude. Figure 1. Physical model of ZnO varistor The IEEE (Working Group 3.4.11) proposed the frequency-dependent model with two nonlinear resistors, presented in Figure 2. The IEEE model is the most accepted varistor model for transients and we will treat, in this paper, implementation of IEEE MOV model in ATPDraw. Figure 2. Model of ZnO arrester proposed by IEEE Working Group 3.4.11 3

This model take into account different delays in the conduction mechanism at different wavefronts of current surges with a set of nonlinear V-I curves. The nonlinear elements A 0 and A 1 are divided by the R-L filter, which ensures high impedance for the fast surges. The characteristics A 0 and A 1 (Figure 3) are defined in relative units, according to the MOV rated voltage. For long duration surge wavefronts, filter has low impedance and elements A 0 and A 1 are in parallel. For fast surge wavefronts, element A 1 is blocked and current flows only through the element A 0. Since characteristic A 0 is higher than A 1, MOV model provides the higher voltage than for the slow surge. The inductance L 0 represents the inductance of the current path through the arrester, also present in the physical model. The role of resistance is to provide convergence in the numerical simulations. Figure 3. Characteristics of nonlinear elements A 0, A 1 of IEEE arrester model The detailed analysis of different varistor model advantages and disadvantages is given in [4]. The overhead distribution lines are represented by distributed parameter model, using the JMARTI frequency dependent model which are the most accepted model for transient study [5,6]. The transformer are represented by BCTRAN model with parameters determined on the basis of evidence and rating data. As an example we analyze real circuit shown as a ATP model on Figure 4 This is an initial model and it was extended of line surge arresters. Results shown on Figure 5 indicates reduction of overvoltage stress due to applying line surge arresters. 4

Figure 4. Initial model of analyzed circuit a) b) c) Figure 5. Simulation results a) system without arresters, b) system with arresters installed with transformer, c) system with line arresters CONCLUSIONS Applying of line surge arresters have led to means of significantly improving line lightning performance. But, this does not necessarily mean that the transmission line with line arresters will have satisfactory outages performance. It is because surge arresters have been installed on distribution lines in high density, in order to decrease outages caused by lightning. As a result, outages due to flashover at insulators on distribution lines have been gradually decreasing. However, as the number of surge arresters installed increases, surge arrester outages may increase as a proportion of total distribution line equipment outages. 5

BIBLIOGRAPHY [1] Wiesław Nowak, Romuald Włodek; Analysis of reverse flashover on outdoor insulation of high and highest voltage lines ; Electrical Review R.LXXVIII Nr 10s/2002, p.226 [2] Harold S. Brewer Reduction of Lightning Caused Interruptions on Electric Power Systems ; Ohio Brass 2004 [3] T. Thanasaksiri; Comparison of Simulation Tools ATPDraw and TFlash for Lightning Overvoltage Studies [4] Nermin Suljanovic, Aljo Mujcic, Vladimir Murko, Practical issues of metal-oxide varistor modeling for numerical simulations ; 28th Conference on Lightning Protection, 2006 [5] Janina Rząsa, Stanisław Wyderka; Modelling of electric power overhead lines in ATP-EMTP; Energetyka XII/2007, p.121 [6] Jakub Furgał; Analysis of operational effects of metal-oxide surge arresters in medium voltage network, Electrical Review V.1/2003, p.85 6