MHPS MHPS. Modular pressure transmitter. Technical documentation. Table of content. Characteristics - applications - technical data

Similar documents
Ultrasonic Sensor (HART)

DS 400 DS 400. Intelligent Electronic Pressure Switch Completely in Stainless Steel. piezoresistive stainless steel sensor

Rosemount Specifications. Product Data Sheet , Rev BA February 2009 PERFORMANCE SPECIFICATIONS

JUMO Wtrans E01. Measuring probe for humidity, temperature, and CO 2 with wireless data transmission. Brief description. Universal Wtrans receiver

ATM.ECO - Analog Pressure Transmitter with Temperature Compensation

Pressure Transmitter SIL

Submersible pressure sensor For oils and fuels Model LF-1

Process transmitter Model UPT-20, with pressure port Model UPT-21, with flush diaphragm

Materials (other materials see WIKA diaphragm seal program) Model S-10

Miniature resistance thermometer Model TR33, thread-mounted

ED701 General Industry Pressure Transmitter

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Submersible pressure sensor For water and wastewater Model LW-1

DTM.OCS.S/N - Modbus Level Transmitter

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. appmeas.co.uk +44 (0)

Pressure transmitter for general industrial applications Model A-10

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

OEM pressure transmitter for general industrial applications Models O-10 (T), O-10 (5)

Flush pressure transmitter For viscous and solids-containing media Model S-11

High-quality pressure transmitter For general industrial applications Model S-10

STD96. Universal Pressure Transmitter with local LCD Display

General Specifications

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

OEM pressure transmitter For mobile working machines Model MH-3

OPTITEMP TT 20 Technical Datasheet

Screw-in resistance thermometers with plug connector

PROGRAMMABLE FIELD TEMPERATURE TRANSMITTER

Field indicator for current loops with HART communication Models DIH50, DIH52

2600T Series Pressure Transmitter Model 264DS Differential Pressure Transmitter. Kent-Taylor

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

Pressure transmitter for mobile hydraulic applications With output signals CANopen and J1939

Strong monosilicon gauge pressure transmitter

Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F

Type F-20-3A Sanitary Pressure Transmitter NEMA 4X with Integral Junction Box

OEM pressure sensor For industrial applications Models O-10 (T), O-10 (5)

MODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With

Online data sheet. PBSH-CB010ST1S0BMA0Z PBS Hygienic PRESSURE SENSORS

Digital flow transmitter for continuous flow measurement

Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F

Valve Island with Electronic I/O

Pressure transmitter for general industrial applications Model A-10

TEK-TEMP 2100A. Explosion-Proof Temperature Transmitter. TEMPERATURE. Technology Solutions

Intrinsically Safe Pressure Transmitter for applications in hazardous environments and shipbuilding industry Model IS-20-S, IS-21-S, IS-20-F, IS-21-F

Intrinsically Safe Pressure Transmitter for highest pressure applications in hazardous environments Model IS-20-H

SATRON VB Pressure Transmitter

Optical laser distance sensors. Dimensioned drawing

Electronic temperature switch with display Model TSD-30

TURCK Inc Campus Drive Minneapolis, MN Application Support: PROX Fax: (763)

Submersible pressure sensor For superior applications Model LF-1

DL.WMS/GPRS/R/SDI-12. Watermanager solution CUSTOMER BENEFITS

SITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview

Pressure transmitter with flameproof enclosure For applications in explosion-protected areas Models E-10 and E-11

DPS 100 DPS 100. Gauge- / Differential- / Absolute Pressure Transmitter

Technical data. General specifications. Measurement range min max. 360

Pressure transmitter For general industrial applications Model A-10

SITRANS T measuring instruments for temperature

ph or ORP Transmitter

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

High-quality pressure transmitter For general industrial applications Model S-20

Assembly 249 (9.80) 259 (10.2) Example: level probe with Pt100 and HUT temperature head transmitter ( ma) ma. Core colors: RD BK YE BU

HART field temperature transmitter Models TIF50, TIF52, TIF62

Non-Submersible Industrial Pressure Transducer

Pressure measurement PBMR Fully welded pressure transmitter for railway applications

Temperature sensor with integrated transmitter for maritime applications, MBT 5560

Digital flowmeter for continuous flow measurement

Digital flow ELEMENT transmitter for continuous flow measurement

Pressure Transmitter Type AKS 32 and AKS 33 REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Digital flowmeter for continuous flow measurement

OEM radar transmitter, for aggressive media level measurement

Type PLC Fitting. Valve for Continuous control. Diaphragm valve. Output

Analogue temperature transmitter Model T91.10, head mounting version DIN form B Model T91.20, head mounting version form J

Resistance thermometer Model TR31, miniature design

JUMO Wtrans probe RTD temperature probe with wireless transmission of the measured values

Optical laser distance sensors. Dimensioned drawing

JUMO Wtrans Receiver with Wireless Data Transmission

Pressure transmitter For sanitary applications Model SA-11

TPFADA FLUSH DIAPHRAGM PRESSURE TRANSMITTER WITH DIGITAL AUTOZERO & SPAN

SEM104 SERIES. SEM104P Pt100 Temperature Transmitter. SEM104TC Thermocouple Temperature Transmitter INDEX SECTION CONTENTS PAGE NO.

prosonic T FMU230, FMU231

Datasheet Platinum Resistance Pt100 In-head (Push Button) Temperature Transmitter TX203P mA output, default range supplied C

Watermanager solution DL.WMS/GPRS/R

Field indicator for current loops with HART communication Models DIH50, DIH52

KENCO Loop Powered Magnetostrictive Transmitter. KMD SERIES Operation and Installation Manual. Table of Contents

Digital inductive conductivity transmitter

Absolute pressure gauge with output signal For the process industry Models APGT and APGT43.160, NS 100 and 160

DOC. NO. : C3200-E04A APPROVED. Smart PressureTransmitter for Gauge and Absolute Pressure Measurement MODEL APT3200

AC AC AC

600T Series Transmitters Model 653L Electronic temperature transmitter (PC programmable for RTD and resistance) Specification Sheet

mass flowmeter for compressed air

General Specifications

JUMO Wtrans Receiver Universal Receiver for JUMO Wireless Measuring Probes

PAD - Heavy Duty Differential Pressure Trasmitter

M224. M C bis. TYPE CODE M K Y 45 / 18 x 60 - / / / - #

Ultrasonic level measuring device, non-contact

Specifications (in accordance with DIN 16086) Equipment family Digibar II Type 1-PE50A1/...; K-PE PE00A1/...; K-PE00... Class of accuracy 0.2 0

Field IT 2600T Series Pressure Transmitters

Ultrasonic level transmitter, non-contact

Incremental encoders Redundant sensing, isolated blind hollow shaft ø mm, cone shaft ø17 mm pulses per revolution

Programmable transmitter of temperature, relative humidity and other derived humidity values with 0 to 10 V outputs Instruction Manual

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Transcription:

Technical documentation Table of content Page 2: Page 3: Page 4: Page 5: Page 6: Page 7: Page 8: Characteristics - applications - technical data Technical data - input quantity - output quantity Electrical connection - process connection 4...20 ma test signal - external operator s control - turning of enclosure Elektronics insert with display - HART communication Dimensions - definitions Ordering code Page-1

Input: Characteristics Output: Option: Turn down: up to 100:1 Accuracy: Indication: Configuration: Applications Technical data overpressure (0,1 bar up to 1000 bar) / absolute pressure (0,25 bar up to 25 bar) 4...20 ma current loop (15...45 VDC), HART-protocol additionally with limit value contacts <0,25% of sensor range (up to 0,25 bar: <0,5% of sensor range) LCD-display with backlighting with keys and/or software Enclosure for electronics: diecast aluminium (degree of protection: IP65 ) Process connection: G1/2B / G1/4B / G1/4A / 1/2NPT / 1/4NPT / M20x1,5 (pressurized parts: NiCr steel) The pressure sensor is suitable to measure overpressure (negative, positive) and absolute pressure. From overpressure can be derived: level (level, volume, mass). Typical areas of use are chemical industry and process engineering. Input Overpressure: 0,1 / 0,16 / 0,25 / 0,4 / 0,6 / 1 / 2,5 / 4 / 6 / 10 / 16 / 25 / 40 / 60 / 100 / 250 / 400 / 600 / 1000 bar Absolute pressure: 0,25 / 0,4 / 0,6 / 1 / 2,5 / 4 / 6 / 10 / 16 / 25 bar Output Analog: 4...20 ma, 2-wire, with superimposed communication signal (HART-protocol) Signal range: 3,6...22,8 ma (on failure: 3,6 ma) Option: additionally with limit value contacts Performance Accuracy: <0,25% of sensor range (up to 0,25 bar: <0,5% of sensor range) According BFSL: <0,125% of sensor range (up to 0,25 bar: <0,25% of sensor range) including non-linearity, hysteresis, non-repeatability, zero point and full scale error (according to IEC 61298-2) Influences: supply: <0,005% of nominal range/1v vibration: <0,01% of nominal range/g at 200 Hz Response time 10...90%: <1ms (<10 ms at medium temperature <-30 C for nominal ranges up to 25 bar) Non-linearity: <0,2% of nominal range (BFSL) according IEC 61298-2 Non-repeatability: <0,1% of nominal range Stability: <0,2% of span (1 year, at reference conditions) Temperature range: 0...80 C (compensated, pressure sensor) Temperature coefficient: within compensated range Mean TC of zero: <0,2% of nominal range / 10 K (<0,4% for ranges <0,25 bar) Mean TC of range: <0,2% of nominal range / 10 K Settings Rise-delay time: Cycle time, update: Damping: Filter adjustment: Display 5 s 0,25 s 200 ms (without concideration of electronic damping) 0...160µA Visible range: 32,5x22,5 mm Indication: 5-digits 7-segments, 8 mm / 8-digits 14-segments, 5 mm / bargraph with resolution 2% Range: -19999...99999 Supply Voltage: 15...45 VDC (current loop) Insulation resistance: >250 MOhm Short circuit-proof: permanent Reverse battery protection: yes (no destruction, no funtion) Overvoltage protection: 500V Environmental conditions Temperature: Operating: -20...70 C / Ambient: -20...70 C / Storing: -40...+85 C Medium: -30...100 C / -40...125 C Humidity: 5...98% relative humidity Shock resistance: 1000 g according IEC 60068-2-27 (mechanical shock) ^Vibration resistance: 20 g according IEC 60068-2-6 (vibration at resonance) Page-2

Technical data (continued) Mechanics Material: Enclosure ektronics: diecast aluminium Enclosure pressure sensor: CrNi steel Wetted parts: CrNi steel Type plate: stainless steel 1.4301 Viewing glass: laminated glass Internal transmission fluid: syntetic oil Process connection: G1/2B / G1/4B / G1/4A / 1/2NPT / 1/4NPT / M20x1,5 Dimensions: see page 7 Protection: degree IP 65 Weight: approx. 1,7 kg Connection: terminal screw (maximum 1,5 mm²), via srewed cable gland M20x1,5 Standards: IEC 61000-4-3 / Pressure equipment directive 97/23/EG Input Measurand: Measuring ranges: overpressure (positive, negative), absolute pressure derived from this: level (level, volume, mass) 0,1 bar up to 1000 bar Pressure range 0,1 0,16 0,25 0,4 0,6 1 1,6 2,5 Over pressure safety 1 1,5 2 2 4 5 10 10 Burst pressure 2 2 2,4 2,4 4,8 6 12 12 Pressure range 4 6 10 16 25 40 60 100 Over pressure safety 17 35 35 50 50 80 120 200 Burst pressure 20,5 42 42 96 96 400 550 800 Pressure range 160 250 400 600 1000 Over pressure safety 320 500 800 1200 1500 Burst pressure 800 1250 1300 1800 3000 Output Output signal: Signal range: Load: 4...20 ma, 2-wire connection with superimposed communication signal for HART protocol 3,6...22,8 ma RLmax = (U - 15 V ) / 0,0228 A RL(max) [ohms] 1333 1111 666 Voltage supply: 15...45 VDC RLmax: maximum load resistance U: Voltage supply Please note: When using communication via a HART modem, a comunication resistance of minimum 250 ohms has to be taken into account. 222 15 20 30 40 45 U[V] Resolution: Read cycle time: Damping: current output: 16 bit indication: adjustable (factory setting: 0...100%) HART commands all 200 ms. continuously adjustable from 0 to 160 µa via electronic insert inside the device, hand-held equipment or PC-software. Factory configuration: 0 µa Page-3

Electrical connection A supply Z S B C D 1+ 2-3+ signal ma test signal E FIELD TERMINALS Electrical connection 4...20 ma HART A: Enclosure B: Voltage supply 15...45 VDC (1+ / 2-) C: 4...20 ma test signal between 2- and test point 3+ D: Internal earthing E: External earthing 1+ 4...20 ma 2- test 3+ The device has a protective system against overvoltage peaks, RF interferences and wrong polarity. Voltage supply: between 15...45 VDC Cable entry: screwed cable gland M20x1,5 (metal) Cable: outer diameter: 6...12 mm cross-sectional area: 0,5...1,5 mm² shielded and twisted 2-wire cable (recommended) Residual ripple: no influence on ma-signal up to 5% within nominal voltage range Influence supplied power: <0,005% of nominal range / 1V Process connection G1/2 (EN837) manometer X1* 20 Pressure connetion: G1/2B manometer (EN837) G1/4B manometer (EN837) G1/4A (DIN3852-E) M20x1,5 1/2NPT 1/4NPT Measuring membrane: NiCr-steel G1/2B *X1: width across 27 G1/4 (DIN 3852-E) G1/4 (EN837) manometer X1* X1* X1* 1/2NPT X1* 1/4NPT 14 G1/4A 13 G1/4B 19 1/2NPT 13 1/4NPT Page-4

4...20 ma test signal 3+ + test signal ma The 4...20 ma test can be measured without interruption of the low-potential circuit between terminal 3(+) and terminal 2(-). The output current is measured with an ammeter for ma across a diode in the output circuit. 2-1+ 4...20 ma current loop External operator s control Span Zero Below the type plate there are 2 key button for easy configuration of zero and span. The keys are Hall effect devices and are completely seperated from other parts of the enclosure. Advatages: - Protection against environmental influence - without wear - ease of operation Rotating of enclosure After unscrewing the M6 Allen screw the enclosure can be rotated up to 360. Advatages: Good reading of the display Operator s controls of the device are easy approachable maximum 360 FIELD TERMINALS Example: turning 90 FIELD TERMINALS Accessories 37 mm 109 mm Holder wall / tube: Holder made of stainless steel for mounting the device on walls or tubes. Supplied parts: holder, fixing clamp with nuts and washers. 70 mm 108 mm 70 mm 99 mm Page-5

Electronic insert with display Display with key buttons for configuration Display F1 P F2 The display is rotatable for approx. 330 With 3 operator s keys is configurable: - Starting measuring value (reference pressure has to be supplied) - Final measuring value (reference pressure has to be supplied) - Zero offset compensation (compensation of position) - Reset - Starting measuring value (reranging without reference pressure) - Final measuring value (reranging without reference pressure) - Damping - Unit (ma, mbar, %) - Fixed current output - Visible range 32,5x22,5 mm - 5-digits 7-segment line, 8 mm high (-19999...99999) - 8-digits 14-segment line, 5 mm high - Bargraph with resolution 2% Electronics V- S Z M XS3 W S Z I- I+ V- L4 XS7 L3 L2 V+ T1 XS1 L+ L- - XS1 voltage supply 15...45 V - XS2 connection sensor - XS3 external keys - XS7 display - J1 solder bridge to select sensor supply J1 vi V+S+U-S-T XS2 U3 HART Communication HART tool: The HART-Tool is a graphical user interface for the MH series with menu-driven progam for configuration. It can be used for putting into operation, configuration, analysis of signals, data backup and documentation of the device. Operating systems: Windows 2000, Windows XP Functions: - Configuration of the devices in on-line operation - Loading and storing the devices data (upload / download) - Linearization of characteristic curve - Documentation of the measuring point Possible HART devices to use: - HART interface (modem) with serial interface of a PC - HART interface (modem) with USB interface of a PC - Hand-held HART communicator Configuration with software via HART communication The following settings are possible: - Adjustment of output current - Simulation of output current - Configurable characteristic values: limits of measuring range unit for display filter function decimal-place linear / square root output signal for flow - HART address - HART TAG number - 2-point calibration (start and end of value) - 6-point calibration Page-6

Dimensions (in mm) ~130 113 S Z 128 P F1 F2 120 183 width across 27 Definitions G1/2 view front view side view top LRL: lower range limit LRV: lower range value TD: turn down Example 1 LRL = LRV URL: upper range limit URV: upper range value URV URL Example 2 0 bar 0,6 bar +1 bar adjusted working range sensor range / nominal range LRV < URV : lower range value (LRV) = 0 bar upper range value (URV) = 0,6 bar upper range limit (URL) = 1 bar Turn down: URL / URV = 1 bar / 0,6 bar Turn down = 1,66 : 1 Set span: URV - LRV = 0,6 bar - 0 bar set span = 0,6 bar (adjusted) (The span is based on the zero point) LRL -1 bar 0 bar adjusted working range 0,8 bar +1 bar nominal range sensor range LRV < URV lower range value (LRV) = 0 bar upper range value (URV) = 0,8 bar upper range limit (URL) = 1 bar mbar Turn down: URL / LRV = 1 bar / 0,8 bar Turn down = 1,25 : 1 Set span: URV - LRV = 0,8 bar - 0 bar set span = 0,8 bar (adjusted) (The span is based on the zero point) Example 3 LRL -1 bar -0,7 bar 0 bar +1 bar adjusted working range nominal range sensor range LRV > URV lower range value (LRV) = -0,7 bar upper range value (URV) = 0 bar upper range limit (URL) = 1 bar LRV Turn down: URL / LRV = 1 bar / 0,7 bar Turn down = 1,43 : 1 Set span URV - LRV = 0 bar - (-0,7 bar) set span = 0,7 bar (adjusted) (The span is based on zero point) URV URL LRV URV URL Page-7

Ordering code H P X X X X X X - X X X Output: 4...20 ma (HART) 0 4...20 ma (HART), electronical limit contacts 1) 1 Kind of pressure: 2) relative 0 absolute 1 relative (±) 2 Pressure range: 3) (please indicate) X Process connection: G 1/2 (EN 837), manometer 0 G 1/4 (EN 837), manometer 1 G 1/4 (DIN 3852 E) 2 1/2 NPT 3 1/4 NPT 4 M20x1,5 5 Material process connection: 4) 1/4-18 NPT 1.4435 (316L) 0 Temperature medium: -30...+100 C 0-40...+125 C 1 Enclosure / connection: diecast aluminium with screwed cable gland M20x1,5 0 5) Configuration: factory configuration 0 6) 1) For more details see the corresponding data sheet: - MH-LVE for electronical limit value contacts customized configuration (please indicate) 1 Other / accessories: special model 0 HART Interface, USB, software 1 Holder wall / tube (stainless steel) 3 2) relative: positive overpressure, negative overpressure (subatmospheric pressure) relative (±): above and below the prevailing atmospheric pressure 3) Coding for X (pressure ranges), given in bar: relative pressure: 0 = 0...0,1 / 1 = 0...0,16 / 2 = =...0,25 / 3 = 0...0,4 / 4 = 0...0,6 / 5 = 0...1 / 6 = 0...1,6 / 7 = 0...2,5 / 8 = 0...4 / 9 = 0...6 / A = 0...10 / B = 0...16 / C = 0...25 / D = 0...40 / E = 0...60 / F = 0...100 / G = 0...160 / H = 0...250 / I = 0...400 / J = 0...600 / K = 0...1000 / L = -1...0 absolute pressure: 2 = =...0,25 / 3 = 0...0,4 / 4 = 0...0,6 / 5 = 0...1 / 6 = 0...1,6 / 7 = 0...2,5 / 8 = 0...4 / 9 = 0...6 / A = 0...10 / B = 0...16 / C = 0...25 / relative pressure (±): M = -1...+1 4) Material in contact with medium: CrNi steel 5) zero: 4,000 ma / span: 20,000 ma / zero offset compensation: without / turn down: without / calibration points: 2 / damping: without / display mode: 100% / output on alarm: 3,6 ma / fixed output: without When the MH-device is ordered with factory configuration this limiting value unit will have the following settings: - Range of indication: 4,0...20,0 - Refresh display: 1 s - Decimal point: XX.xx - Unit: without - Stabilisation zero point: 2 - Limit value 1: trigger value 12 ma / delay time: 0 s - Limit value 1: reset value 11 ma / delay time: 0 s - Limit value2: trigger value 18 ma / delay time: 0 s - Limit value 2: reset value 16 ma / delay time: 0 s - Locking of programming: without - Calibration points: without - TAG number: 0 6) the possibilities of the technical data can be selected. In case of not given values the details of factory-set are used. Page-8 Subject to change, version 42-030