OEM radar transmitter, for aggressive media level measurement

Similar documents
Ultrasonic level measuring device, non-contact

Level measurement Radar

Ultrasonic level transmitter, non-contact

INLINE flowmeter for continuous flow measurement

INLINE flowmeter for continuous flow measurement

INLINE flowmeter for continuous flow measurement

Digital inductive conductivity transmitter

Type PLC Fitting. Valve for Continuous control. Diaphragm valve. Output

Digital flow ELEMENT transmitter for continuous flow measurement

Pressure measurement. Process pressure/hydrostatic VEGAWELL 52. Product Information

Digital flow transmitter for continuous flow measurement

Pressure measurement. Process pressure/hydrostatic VEGAWELL 72. Product Information

Process transmitter Model UPT-20, with pressure port Model UPT-21, with flush diaphragm

3DLevelScanner. Technical Data Sheet. Level Sensor. Non-Contact, Multiple-Point Measurement

INSERTION paddle wheel flowmeter for continuous flow measurement

Pressure measurement. Process pressure/hydrostatic VEGAWELL 52. Product Information

3DLevelScanner. Technical Data Sheet. Level Sensor. Non-Contact, Multiple-Point Measurement

Digital batch controller

Digital flowmeter for continuous flow measurement

Digital flow ELEMENT transmitter for continuous flow measurement

Digital flowmeter for continuous flow measurement

Level Measurement. Continuous level measurement - Radar transmitters SITRANS LR400 5/229. Overview

Level Measurement. Continuous level measurement - Radar transmitters SITRANS LR400 5/229. Overview

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

SALES SERVICE +358 (0)

ph or ORP Transmitter

The Radar Level Meters can be installed both in metallic or non metallic tanks; their use is not harmful to humans or environment.

Conductivity Transmitter

Level Measurement Continuous level measurement Radar transmitters

Digital conductivity transmitter

Positioner with HART Communication Type 3780

Level Measurement Continuous level measurement Radar transmitters

Electromagnetic Flow Transmitter

Main features. Operation. LEVEL Transmitters

Level and Pressure. Product Information. Vibrating level switches

Mobrey Ultrasonic. MSP422, MSP400RH, and MSP900GH Level Transmitters. Product Data Sheet February 2015 IP2045, Rev EA

Level Measurement. Continuous level measurement Radar transmitters SITRANS LR460. 4/258 Siemens FI

prosonic T FMU230, FMU231

Valve Island with Electronic I/O

Miniature resistance thermometer Model TR33, thread-mounted

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Flow Measurement SITRANS F M

Technical Information Condumax CLS21D/CLS21

Intrinsically safe pressure transmitter MBS 4201, MBS 4251, MBS 4701 and MBS 4751

FLOWave SAW-Flowmeter

The transducer component converts the measured signal and displays the actual value.

Absolute pressure gauge with output signal For the process industry Models APGT and APGT43.160, NS 100 and 160

2/2 way Proportional Valve (motordriven)

TLR wire System Level Radar. MICROWAVE level meter GENERAL FEATURES OPERATION PRINCIPLE

2-Wire. Level Gauge BM 702

OPTIWAVE 1010 Technical Datasheet

Valve Series V2001 Globe Valve Type 3321 with Pneumatic or Electric Actuator

PiloTREK SZINTTÁVADÓK LEVEL TRANSMITTERS PU L S E BU RS T R A DA R LE V E L TR A NSMIT TERS K- BA N D R A DA R FO R LI Q U I DS

Flow Measurement SITRANS F M. Flow sensor MAG /49. Overview

RMA42. Technical Information

Explosion proof rotary actuator - On/Off or programmable regulating actuator

Digital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting

K-BAND RADAR FOR LIQUIDS

Technologies, Solutions, and Applications. Guided Wave Radar for Level

2-way motor valve. Power consumption. Type 8746 MFC/MFM. Technical data Materials Body Housing Seals 1) Pressure Range 2) < 1 % FS Sensitivity Span

OPTIFLUX 5000 Technical Datasheet

SITRANS F flowmeters SITRANS F M. Flow sensor MAG /48 Siemens FI Overview

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

TIDALFLUX 2300 F Technical Datasheet

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

Resistance thermometer Model TR30, compact design

RTD Temperature Sensor omnigrad T -TSM 480, TR 480. Hygienic RTD sensor with Pt 100, class A TSM 480 with electronics programmable via PC

Coriolis Massflowmeter

Universal process controller econtrol

2-wire level transmitter

2/2-Way Solenoid Control Valve

JUMO dtrans T01 HART / T01T HART / T01 Junior / T01 Ex / T01 HART Ex Programmable 2-wire transmitter

Universal process controller econtrol

Resistance thermometer Model TR30, compact design

Georg Fischer Piping Systems Point, Ultrasonic & Radar Level Products

Rosemount 3101, 3102, and 3105

Process pressure transmitter Model IPT-10, standard version Model IPT-11, flush diaphragm

Field indicator for current loops with HART communication Models DIH50, DIH52

OEM pressure transmitter for general industrial applications Models O-10 (T), O-10 (5)

Liquid Level Switches

Design and applications

6GHz Intelligent Radar Level Meter Product Manual. Model:KRD520 SERIES

Switching. Radar. Overview 114 VEGAMIP series Mounting adapter 120

JUMO dtrans T01 HART / T01T HART / T01 Junior / T01 Ex / T01 HART Ex Programmable 2-wire transmitter

Technical Data. General specifications. Rated operating distance s n 3 mm

omnigrad T - TSM 480, TR 480. Technical Information. RTD Temperature Sensor Hygienic design TSM 480 with electronics programmable via PC

Resistance thermometers for process technology

OEM pressure sensor For industrial applications Models O-10 (T), O-10 (5)

Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F

OPTIFLUX 5000 Technical Datasheet

0 2 1 â Ó. itemp HART TMT182. Technical Information

Digital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version

Pressure transmitter For general industrial applications Model A-10

Submersible pressure sensor For oils and fuels Model LF-1

Micropilot M FMR250. Technical Information

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

ECHOTEL 961/962. Ultrasonic level switches. Loop or line powered D E S C R I P T I O N F E AT U R E S A G E N C Y A P P R O VA L S

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Pressure transmitter for general industrial applications Model A-10

Cable Glands, Metal, for shielded EMC Cables CG.EM.*.*.*

Transcription:

OEM radar transmitter, for aggressive media level measurement C ompact for level measurement up to 20 m 4... 20 ma/hart - 2 wires Adjustable with P C ATEX approvals Type 8136 can be combined with... Type 8611 Type 8635 Type 2712 (8630) Type 8644 PLC Universal PI controller econtrol SideControl EEx Continuous TopControl system Valve islands The Type 8136 is a non-contact radar level transmitter for continuous level measurement. The unit is available in two versions: - with encapsulated horn antenna particularly suitable for level measurement of aggressive liquids in small vessels. - with plastic horn antenna particularly suitable for flow measurement in open flumes or gauge measurement in waters. Accuracy diagram } Dead zone Encapsulated horn antenna version Plastic horn antenna version General data Materials Housing / Cover Seal ring / Ground terminal Mounting strap / Fixing screws Wetted parts Encapsulated horn antenna version Process fitting / Antenna / Seal Plastic horn antenna version Process fitting Horn antenna / Focussing lens Display * Process fitting Max. torque mounting boss PBT, Stainless steel 316L / P C NBR / Stainless steel 316Ti/316L (1.4571/1.4435) Stainless steel 304 (1.4301) / Stainless steel 316L (1.4435) PVDF / PVDF (completely encapsulated) / FKM Stainless steel 316L (1.4435) PBT-G F30 / PP LC D in full dot matrix (in option) Thread G 1 1/2 A or NPT 1 1/2 (Encapsulated horn antenna version) Mounting strap 170 mm (Plastic horn antenna version) 4 Nm (mounting screws - strap on the sensor housing) Electrical connection Cable glands Measuring type Min. dielectric figure εr > 1.6 Dead zone 50 mm 1) Measuring range Process temperature -40 up to + 80 C Vessel pressure Vibration resistance Temperature coefficient Resolution Frequency Interval Beam angle at 3dB Adjustment time Distance between process fitting and product surface 0.05 up to 10 m (Encapsulated horn antenna version) 0 up to 20 m (Plastic horn antenna version) -1 up to 3 bar (-100 up to 300 kpa) Mechanical vibrations with 4.g and 5...100 Hz 0.03%/10K (Average temperature coefficient of the zero signal - temperature error) max. 1mm K-band (26 GHZ technology) approx. 1s 22 (Encapsulated horn antenna vers.); 10 (Plastic horn antenna vers.) > 1 s (dependent on the parameter adjustment) Accuracy ± 5 mm (see diagramm) * to be ordered separately 1) Encapsulated horn antenna version. In products with low dielectric value up to 50 cm. www.burkert.com p. 1/6

Electrical data Power supply Permissible residual ripple Output signal Resolution 1.6 µa Fault signal Current limitation Load Damping (63% of the input variable) Environment Ambient temperature Relative humidity Standards and approvals Protection Overvoltage category Protection class Standard EMC Security NAMUR Approvals 14 to 36 V DC or 14 to 30 V DC (EEx ia instrument) < 100 Hz: U ss <1 V 100 Hz...10 khz: U ss <10 mv 4...20 ma/hart current output unchanged; 20.5 ma; 22 ma < 3.6 ma (adjustable) 22 ma Fulfilled NAMUR recommendation NE 43 Specifications EEx see load diagram 0...999 s, adjustable -40 to +80 C (operation and storage) 20-80 %; non condensated IP66/IP67 with gland mounted and tightened III II EN61326 EN61010-1 NE 21; NE 43 ATEX : EN50014; EN50020; EN50284 WHG FM (in progress) - Protection Categories 1/2 G or 2G - Certification EEx ia IIC T6 Conformity specifications 1) Power supply Ui Short circuit rating li Power limitation Pi Ambient temperature Internal capacity Ci Internal inductivity Li 1) homologation certificate PTB 03 ATEX 2060 X Load diagram 30 V 131 ma 983 mw -40 up to +55 C (depend on categories) negligible negligible Target applications Dosing and processing systems Level measurement: The radar measuring principle is particularly suitable for continuous level measurement of toxic and corrosive substances. The measurement is non-contacting, i.e. there is no direct contact with the medium. Due to the very small process connection and the PVDF encapsulated antenna, the 8136 radar sensor is ideal for this application. Open flumes Flow measurement for heavy demands: Radar sensors like the Type 8136 are also suitable for flow measurement in open flumes. For wastewater treatment in chemical plants, where wastewater temperatures change drastically or where solvents are contained in the wastewater, the use of radar sensors is recommended. 1 HART load 2 Voltage limit EEx ia instrument 3 Voltage limit non-ex instrument 4 Supply voltage p. 2/6

Principle of operation The radar transmitter consists of an electronic housing, a process fitting element the antenna and a sensor. The antenna emits short radar pulses with a duration of approximate 1 ns to the measured product. These pulses are reflected by the product surface and received by the antenna as echoes. Radar waves travel at the speed of light. The running time of the radar pulses from emission to reception is proportional to the distance and hence to the level. The determined level is converted into an output signal and transmitted as an measured value. The transmitter can be adjusted with: the program module with display the suitable Bürkert DTM in conjunction with adjustment software according to the FDT/DTM standard, e.g. PACTware and PC. a HART handheld The entered parameters are generally saved in the transmitter Type 8136. Optionally, parameters may also be uploaded and downloaded with the program module with display or in PACTware Set up with program module with display The program module with display can be inserted into the transmitter and removed again at any time. It is not necessary to interrupt the power supply. The transmitter is ajusted via the four keys of the program module with display. Program module with display LCD Display Interrupt input Jump to the next higher menu Indicating of the menu item number Move to the menu overview Confirm selected menu Edit parameter Save value Change value of parameter Menu change List entry select editing position Set up with PACTware / DTM and HART communication The transmitter can be operated directly on the instrument via PACTware or via the HART signal on the signal cable. An interface adapter is necessary for the adjustment with PACTware. For the setup of the Type 8136, DTM-Collection in the actual version must be used. The basic version of this DTM Collection incl. PACTware is available as a free-of-charge download from the Internet at www.burkert.com. Connecting the PC via HART to the signal cable 1. Transmitter 8136 2. HART-USB Modem 3. Resistance 250 Ohm Power supply Necessary components : Transmitter 8136 PC with PACTware and suitable Bürkert DTM HART-USB Modem from the market Resistance approx. 250 Ohms Power supply unit Bürkert DTM p. 3/6

Dimensions [mm] Encapsulated horn antenna version approx. Cable gland Closing screw Plastic horn antenna version approx. Cable gland Mounting strap Closing screw Adapter flange for plastic horn antenna ø 80 mm version O-ring seal * the strap is to order separately Flange ø D ø k ø d Number of hole DN100 PN16 220 180 18 8 x 45 (=360 ) ASME (ANSI B16.5) 4 150 psi 228.6 190.5 19.1 8 x 45 (=360 ) p. 4/6

Ordering chart for compact transmitter Type 8136 Specifications Voltage supply Output Antenna version Process connection Electrical connection Item no. without program module no display Standard version 14-36 V DC 4-20 ma/hart Encapsulated horn G 1 1/2 Cable gland M 20 x 1.5 560 146 (2 wires) - 40 mm NPT 1 1/2 Cable gland M 20 x 1.5 560 148 Plastic horn - 80 mm Mounting strap or adapter flange Cable gland M 20 x 1.5 560 150 EEx version - 14-30 V DC 4-20 ma/hart Encapsulated horn G 1 1/2 Cable gland M 20 x 1.5 560 147 ATEX approval (2 wires) - 40 mm NPT 1 1/2 Cable gland M 20 x 1.5 560 149 Plastic horn - 80 mm Mounting strap or adapter flange Cable gland M 20 x 1.5 560 151 Process connection Tri-Clamp 2, 3 bolting DN50, DN80 PN3, DIN 11851 / 316L without compression flange, with compression flange DN80PN16, ANSI3, JIS DN80 10K / PPH adapter flange DN150PN16 FKM /PPH ANSI4 150PSI FKM /PPH ANSI6 150PSI FKM /PPH JIS DN100 10K FKM /PPH JIS DN150 10K FKM /PPH Please also use the request for quotation form on page 6 for ordering a customized transmitter. Approvals FM agreement (in progress) Ordering chart - accessories for transmitter Type 8136 (has to be ordered separately) Specifications Item no. Set with 2 reductions M 20 x 1.5 / NPT1/2 + 2 neoprene flat seals for cable gland + 2 screw-plugs M 20 x 1.5 551 782 Program module with display 559 279 Hart-USB Modem 560 177 Mounting strap 300 mm 559 839 Adapter flange DN100PN16 FKM / PPH 560 437 Adapter flange ASME (ANSI B 16.5) 4 150 PSI FKM /PPH 560 436 p. 5/6

Customized transmitter Type 8136 - request for quotation Please fill in and send to your local Bürkert Sales Centre with your inquiry or order. Company: Contact person: Customer No.: Department: Address: Tel. / Fax.: Postcode / Town: E-mail: Radar level transmitter 8136 Quantity: Desired delivery date: Antenna Encapsulated horn in PVDF Plastic horn in PP Process fitting connection: Compression flange with without External thread G 1 1/2 NPT 1 1/2 Tri-Clamp 2 PN3 3 PN3 Bolting DN50 PN3 DN80 PN3 Mounting strap 170 mm 300 mm Adapter flange DN100 PN16 ANSI 4 JIS DN100 10K DN150 PN16 ANSI 6 JIS DN150 10K Program module and display Yes No ATEX approval Yes No WHG approval Yes No FM approval in progress PLC Type 2712 with 8630 - Valve with TopControl system Type 8136 - Radar level transmitter Type 2100 - Angle seat valve Type 8110 - Level sensor To find your nearest Bürkert facility, click on the orange box www.burkert.com In case of special application conditions, please consult for advice. We reserve the right to make technical changes without notice. Christian Bürkert GmbH & Co. KG 0806/1_EU-en_00895041 p. 6/6