Operating Instructions

Similar documents
Operating Instruction

Level and Pressure. Product Information. Conductive level detection

Operating Instruction

Level and Pressure. Product Information. Vibrating level switches

KSR-Level sensor KSR-Schwimmer-Magnetschalter KSR Contact Protection Relays

Operating Instruction

Operating Instructions

SINEAX B 811 Power Pack with additional Functions

DT1100 E xx xx (PS) Galvanic Isolators. Operating Instructions

Level Limit Switch nivotester FTL 370, FTL 372

DT1100 xx xx xx PS. Isolators, Isolator / Power Supplies. Operating Instructions

Operator Manual. Transmitters Series KAT-... Analog transmitters in 2-wire technique

SINEAX TI 807 Passive DC signal isolator. SINEAX TI 807 Passive DC signal isolator

Level detection in liquid. Conductive. VEGAKON 61 VEGAKON 66 Probes EL 1, 3, 4, 6, 8. Product Information

SINEAX TI 807 Passive DC signal isolator

Intrinsically Safe Compact Controller CTR 210i. Intrinsically Safe Bargraph Indicator. BGI 210i

Level Limit Switch nivotester FTL 325 P

SALES SERVICE +358 (0)

Operating Instructions. Indication and adjustment module PLICSCOM

3 Ex i Isolators. Switching Repeater with Power Relay (250 V / 4 A) Type 9170/ Type 9170/

MINI MCR-SL-UI-I-LP-NC

Transducer transmitter BILT 4 II 2(1) G. Technical Manual

Indicomp 2, Indicomp 2-Ex. Indicator and alarm signalling unit 10/ EN

Inductive sensor slot-type SI2-K08-AP7

Level Measurement silometer FMX 570

Remote Switching Unit nivotester FTL 320

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

SIMEAS-T. Operating Instructions Transducer without auxiliary power. 7KG6111 and 7KG6101. Operating Instructions

06528E00. ATEX / IECEx NEC 505 NEC 506 NEC 500

Electronic relays. Monitoring. Monitoring

INSTALLATION AND OPERATION MANUAL

Binary Output Series 9175

Temperature Input Module for Zone 1 Series 9482/32

JUMO dtrans T02 Programmable 4-wire Transmitter (Smart Transmitter)

JUMO dtrans T02 Programmable 4-wire Transmitter (Smart Transmitter)

Connection. Input EEx ia IIC. Sense. Fine tuning adjustment. Fine tuning amplifying. Amplifying. Adjustment. Output. Composition

Installation and Operational Instructions for ROBA -switch Type 017._00.2

RMA42. Technical Information

SINEAX / EURAX 2I1 Passive DC signal isolator

Digital Input Module NAMUR Ex i / I.S. Inputs, 16 Channels for Zone 1 / Div. 1 Series 9470/22

Technical Information Nivector FTC968, FTC968Z

... for hydraulic and general applications in hazardous areas

2 Safety Barriers. Single-Channel Safety Barriers with Electronic Current Limitation Series 9004

DS 400 DS 400. Intelligent Electronic Pressure Switch Completely in Stainless Steel. piezoresistive stainless steel sensor

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. appmeas.co.uk +44 (0)

SET Installation and Operating Instructions. Level switch for two sensors

Pressure measurement. Process pressure/hydrostatic VEGAWELL 72. Product Information

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Isolators A3/1. Vibration Transducer Supply Unit Series

SINEAX TV 808, 1 channel Isolating Amplifier unipolar/bipolar

EMD-FL-3V-400. Electronic monitoring relay for voltage monitoring in three-phase networks. INTERFACE Data sheet _en_03. 1 Description.

PRetrans Table of contents

Hydrostatic Level Measurement silometer FMB 672 Z, FMB 677 Z

MACX MCR-EX-SL-RPSSI-I-UP(-SP)

Zelio Control Measurement Relays

3 Ex i Isolators. Temperature Transmitter with Output 0/ ma, without Limit Value Contact (Field Circuit Ex i) Type 9182/.0-5.

Isolators A3/1.

Positioner with HART Communication Type 3780

Original operating instructions Fail-safe inductive sensor GG507S / / 2013

09746E00. ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone Zone Division Ex i

Original operating instructions Fail-safe inductive sensor GM504S / / 2010

RAD-IN/OUT-8D. Digital extension modules for the bidirectional wireless system. INTERFACE Data sheet _en_05. 1 Description

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160

Operating instructions Fail-safe delay timer AZS About this document. Content

JUMO dtrans T01 HART / T01T HART / T01 Junior / T01 Ex / T01 HART Ex Programmable 2-wire transmitter

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160 Rev. F

Power supply CP-D 12/2.1

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

QUINT-PS-24DC/24DC/10

3 Ex i Isolators. Temperature Transmitter without Output 0/ ma, with Limit Value Contact (Field Circuit Ex i) Type 9182/.

Analog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/

Power supply CP-T 24/20.0 Primary switch mode power supply

INSTRUCTION MANUAL (ATEX / IECEx)

KFS. Flap-type flow meter. Design and range of application

Isolating Repeater Input Series 9163

Valve amplifier for proportional valves with electrical position feedback

MINI MCR-SL-UI-f(-SP)

Power supply CP-E 24/2.5

Power supply CP-D 24/4.2 Primary switch mode power supply

Nivotester FTR325. Technical Information. 1-channel switch amplifier for the microwave barrier Soliwave FDR50/FQR50

JUMO dtrans T01 HART / T01T HART / T01 Junior / T01 Ex / T01 HART Ex Programmable 2-wire transmitter

Resistance thermometer Model TR30, compact design

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series

Power supply CP-T 48/20.0 Primary switch mode power supply

Safety Manual VEGATOR 121, 122. With SIL qualification. Document ID: 49221

Plug-in module SIRAX TI 807 Passive DC signal isolator

Connection. Input EEx ia IIC. Input I. Input II R 1 R 1 A B A 2+ B LB SC. yellow. red. Composition

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 20 ms. 60 ms. 60 ms. Approx. 1.3 kg. Approx. 0.9 kg. Approx. 5.

Submersible pressure sensor For water and wastewater Model LW-1

Submersible pressure sensor For oils and fuels Model LF-1

Power supply CP-T 48/5.0 Primary switch mode power supply

Safety Manual VEGATOR 111, 112. With SIL qualification. Document ID: 49220

Operating Instructions

User and Safety Manual ProLine P224xx P1

Power supply CP-T 24/10.0 Primary switch mode power supply

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1.

Power supply CP-T 24/40.0 Primary switch mode power supply

Process Protection Acoustic sensors for pump monitoring

Binary Output without Power Supply Series 9176

Transcription:

Level and Pressure Operating Instructions VEGATOR 620, 621, 622 max. 0 10 min. 0 10 on VEGATOR 622! 6 7 8 9 10 11 12 13 14 in out

Contents Contents Safety information... 2 Note Ex area... 2 1 Product description 1.1 Function and configuration... 3 1.2 Approvals... 3 1.3 Types and versions... 4 1.4 Technical data and dimensions... 2 Mounting and installation instructions... 9 3 Electrical connection 3.1 Connection instructions... 10 3.2 Connection instructions for Ex approved applications... 10 3.3 Connection diagrams... 11 4 Setup 4.1 Indicating and adjustment elements... 13 4.2 Setup sequence... 14 4.3 Switching point adjustment... 1 Diagnostics.1 Maintenance... 17.2 Repair... 17.3 Failure rectification... 18 Safety information Please read this manual carefully, and also take note of country-specific installation standards (e.g. the VDE regulations in Germany) as well as all prevailing safety regulations and accident prevention rules. For safety and warranty reasons, any internal work on the instruments, apart from that involved in normal installation and electrical connection, must be carried out only by qualified VEGA personnel. Note Ex area Please note the attached safety instructions containing important information on installation and operation in Ex areas. These safety instructions are part of the operating instructions and come with the Ex approved instruments. 2 VEGATOR 620 622

Product description 1 Product description 1.1 Function and configuration VEGATOR 620 622 signal conditioning instruments are module units with plug-in socket, suitable for carrier rail mounting (DIN 46 277). In conjunction with sensors they are used for level detection and switching command output, which is triggered by relay and transistor switches. Typical applications are double point controls, e.g. pump controls (on/off) and monitoring functions such as overfill or dry run protection. The instruments are equipped with adjustable integration time. The integrated fault monitoring (not with VEGATOR 620) detects short circuit or interruption of the measuring circuit. In case of failure, a failure LED lights up. The level relay and the transistor output deenergise. To construct a measuring system you need a VEGATOR level switch and a sensor with analogue measured data transmission, i.e. - capacitive meas. probes, - hydrostatic pressure transmitters or - process pressure transmitters. 1.2 Approvals If measuring systems are installed according to the following approvals, the appropriate official documents have to be noted and the regulations observed. The documents are supplied with the respective measuring system. WHG approval VEGATOR 621 and 622 signal conditioning instruments with capacitive meas. probes or pressure transmitters as part of an overfill protection according to WHG. General type approval no. Z.-6.13-10 Ex approval When using measuring systems in Ex and StEx areas, the instruments must be suitable and approved for these applications and explosion zones. The suitability is checked by approval authorities and certified in approval documents. VEGATOR 621 Ex and 622 Ex are provided with Ex approval according to CENELEC (PTB no. Ex-96.D.2068). max. min. 0 10 CE conformity VEGATOR 620, 621 and 622 signal conditioning instruments see 1.4 Technical data. 0 10! on VEGATOR 622 6 7 8 9 10 11 12 13 14 p p VEGATOR VEGATOR 620 622 3

Product description 1.3 Types and versions VEGATOR 620 Single point level switch (fixed switching hysteresis) with selectable mode A/B (A = overfill protection, B = dry run protection) and adjustable integration time Inputs: - active 1 capacitive probe, 1 hydrostatic pressure transmitter or 1 process pressure transmitter - passive for connection to an active circuit Output: Application: 1 relay (spdt) level detection, overfill protection, dry run protection Level VEGATOR 620 single point level switch off on Time t When using two VEGATOR 620 connected to one sensor, it is possible to provide a dual single point control. It is possible to connect up to 10 VEGATOR 620 to one sensor, see 3.3 Connection diagrams. Level 1 off 1 on 1 off 1 2 on 2 off 2 on 2 Time t Double single point control with two VEGATOR 620 VEGATOR 621 Single point level switch (fixed switching hysteresis) with fault monitoring, selectable mode A/B (A = overfill protection, B = dry run protection) and adjustable integration time Input: Outputs: Approval: Application: 1 capacitive probe or 1 hydrostatic pressure transmitter or 1 process pressure transmitter 1 relay (spdt) 1 transistor [EEx ia] IIC, as part of an overfill protection acc. to WHG level detection, overfill protection, dry run protection Ex area Level VEGATOR 621 single point level switch off Non-Ex area on Time t 4 VEGATOR 620 622

Product description VEGATOR 622 Double point level switch with fault monitoring, adjustable switching hysteresis, selectable mode A/B (A = overfill protection, B = dry run protection) and with adjustable integration time Input: 1 capacitive electrode 1 hydrostatic pressure transmitter 1 process pressure transmitter Outputs: 1 relay (spdt) 1 transistor Approvals: [EEx ia] IIC, as part of an overfill protection acc. to WHG Application: Min./max. control, overfill protection, dry run protection Max. Min. Ex area Level VEGATOR 622 double point level switch off on Non-Ex area off Time t 1.4 Technical data and dimensions General data Power supply Operating voltage Power consumption Fuse - supply range T 1 A, 20 V Measurement data input, general Number Input type Range Sensor 20 72 V DC 20 20 V AC, 0/60 Hz (sine) in case of emergency power supply with curve form extremely deviating from sine: max. 12 V AC (rectangle) max. 3 W (3 18 VA) Sensor supply voltage - VEGATOR 620 24 V DC - VEGATOR 621, 622 1 18 V DC Switching threshold Min. hysteresis - VEGATOR 620, 621 80 µa - VEGATOR 622 80 16000 µa 1 current input active two-wire input analogue 4 20 ma capacitive probes hydrostatic pressure transmitters process pressure transmitters 4 20 ma adjustable Current limitation Temperature error Connection cable Resistance per wire - VEGATOR 620 max. 20 Ohm - VEGATOR 621, 622 max. 3 Ohm at 24 ma, permanently shortcircuit proof 0.0 %/10 K of range 2-wire (standard cable) VEGATOR 620 622

Product description Additional measurement data input on VEGATOR 620 Number 1 additional current input Input type passive two-wire input analogue Range 4 20 ma Inner resistance 22 Ohm Application switching in series with active inputs of e.g. VEGATOR 620, VEGAMET 601 Hysteresis 80 µa Temperature error 0.0 %/10 K of range Relay output Number Contact Contact material Switching voltage Switching current Breaking capacity 1 output 1 spdt (12-13 open, 12-14 close) AgCdO and Au plated min. 10 mv DC max. 20 V AC, 20 V DC min. 10 µa DC max. 3 A AC, 1 A DC max. 70 VA, 4 W Transistor output (not on VEGATOR 620) Number 1 output (synchronously switching with the relay outputs) Switching voltage U CE max. 36 V DC Switching current I C max. 60 ma DC (short circuit proof, transistor limits the current in case of short circuit to a stand-by current of approx. ma) Voltage loss U CE - 1. V at I B = 60 ma Blocking current I O < 10 µa Electrical connection Screw terminal max. 1. mm 2 Electrical protective measures Protection - instrument IP 30 - socket IP 20 Protection class II Overvoltage category II Mechanical data Mounting carrier rail mounting acc. to DIN 46 277, p. 3 Dimensions W = 36 mm, H = 118. mm, D = 134 mm Weight approx. 170 g 6 VEGATOR 620 622

Product description Ambient conditions Permissible ambient temperature Storage and transport temperature Option Indicating elements LED in front plate Functions Mode (selectable) Integration time (adjustable) -20 C +60 C VEGATOR 620: With an operating voltage of 60 V DC 72 V DC the permissible ambient temperature declines linearly from 60 C to 40 C. -40 C +70 C specially protected (tropicalised) electronics green on: operating voltage on yellow: switching point control red: fault signal overfill protection (A) dry run protection (B) 0.2 20 sec. Adjustment elements Front plate one or two potentiometers with scale 0 10 for switching point adjustment On top cover, to the side DIL for adjustment of: - mode A/B (A = overfill protection, B = dry run protection) - integration time - switch on/off delay Electrical separation measures Reliable separation acc. to VDE 0106, part 1; between - reference voltage 20 V - insulation resistance 2.3 kv - test voltage 2.3 kv power supply, measurement data input, level relay and transistor output CE conformity VEGATOR 620 622 signal conditioning instruments meet the protective regulations of EMC (89/336/EWG) and NSR (73/23/EWG). The conformity has been judged acc. to the following standards: EMC Emission EN 0 081-1: 1992 Susceptibility EN 0 082-2: 199 NSR EN 61 010-1: 1993 VEGATOR 620 622 7

Product description Ex technical data Measurement data input (intrinsically safe signal circuit) Classification [EEx ia] IIC Max. values - voltage U O - 20 V - current I O - 12 ma - wattage P O - 624 mw Characteristics linear Effective internal inductance L i negligible Effective internal capacitance C i negligible [EEx ia] IIC [EEx ib] IIC Max. permissible external inductance L O 0. mh 1 mh 1. mh 2 mh Max. permissible external capacitance C O 97 nf 78 nf 68 nf 200 nf The intrinsically safe circuits are reliably separated from the non intrinsically safe circuits up to a peak value of 37 V. In case of failure, the max. voltage on the non intrinsically safe circuits must not exceed 20 V. Carrier rail mounting 3 x 7. or 3 x 1 acc. to EN 0 022 Transparent cover 4, 118, on 6 7 8 9 10 11 12 13 14 134 36 8 VEGATOR 620 622

Mounting and installation instructions 2 Mounting and installation instructions Mounting Each series 600 signal conditioning instrument consists of a terminal socket for carrier rail mounting DIN 46 277 and a module unit. The supply voltage can be connected to the terminals 9 and 10 of the terminal socket. If there are adjoining series 600 instruments, it is possible to continue the connection L1 and N via the supplied jumpers. Note! The jumpers must never be used on single instruments or at the respective end of a row of instruments, as there is the danger of coming into contact with the supply voltage, or of causing a short circuit. The signal conditioning instrument must always be mounted outside hazardous areas or special Ex protective measures must be taken. Transparent cover To protect the instrument against unauthorised or inadvertent use, the front plate of VEGATOR can be provided after setup with a lockable transparent cover. To remove transparent cover, see drawing below. Coding To avoid inadvertent swapping of the different signal conditioning instruments, the terminal socket is provided with pins and the signal conditioning instrument with appropriate gaps (mechanical coding). An instrument coding with coded pins in different positions ensures that the various signal conditioning instruments cannot get mixed up. Ex instruments An Ex coding with fixed coded pin ensures that non Ex and Ex instruments cannot get mixed up. The coding is part of the explosion protection: On VEGATOR Ex the supplied coded pins (instrument coded pin and Ex coded pin) must be inserted by the user according to the table below. Instrument Ex coding coding VEGATOR 620 2 VEGATOR 621 2 VEGATOR 622 2 VEGATOR 621 Ex 2 A VEGATOR 622 Ex 2 A Separating wall (must be always plugged on Ex instruments) Ex coding Instrument coding VEGATOR 620 622 A o B o C o 1 o 2 o 3 o o o o 0...10V VEGA Plug 7 o 8 o 9 o o o o N L1 6 7 8 9 10 11 12 13 14 VEGATOR 620 622 9

Electrical connection 3 Electrical connection 3.1 Connection instructions The following connection plans are valid for standard as well as for Ex versions of the signal conditioning instruments. Please observe the following instructions: - the relay contacts are shown in their condition in the absence of current - if strong electromagnetic interferences are expected, we recommend the use of shielded cable for the signal cables - the shielding must be grounded only on one sensor or signal conditioning instrument side - if there is the danger of overvoltage, the use of VEGA overvoltage arresters is recommended - the connection should be made according to country-specific installation standards (e.g. in Germany acc. to the VDE regulations). 3.2 Connection instructions for Ex approved applications For the following applications, certified instruments are required: - in hazardous areas (if necessary, observe the special national regulations) - as part of an overfill protection system acc. to WHG - in the shipbuilding industry - for pressurized vessels. For these applications, the respective official documents (test reports, test certificates, general type approval and conformity certificates) as well as the applicable mounting and operating instructions should be observed. The official documents are supplied with the respective instrument. In Ex applications, the voltage supply of the sensor must be delivered only through an intrinsically safe circuit. This can be done by means of: - VEGATOR series 600 signal conditioning instrument in Ex version - not certified VEGATOR series 600 signal conditioning instrument with VEGA safety barrier type 14 Please also note the official documents of these additional instruments. 10 VEGATOR 620 622

Electrical connection 3.3 Connection diagrams Sensor Sensor Sensor Current input passive + - + - + - 1 2 + - 1 2 VEGATOR 620 VEGATOR 621 VEGATOR 622 Transistor output + - + - 6 6 Relay output 9 10 11 12 13 14 9 10 11 12 13 14 9 10 11 12 13 14 + Ð + Ð + Ð L1 N L1 N L1 N Supply voltage Transistor outputs in conjunction with a PLC I C + - - U CE U B + E 1.0 + I C U CE - + E 1.1 VEGATOR 621 VEGATOR 622 PLC VEGATOR 620 622 11

Electrical connection Extension example for VEGATOR 620 Instrument 1 = VEGATOR 620 622 switched to active mode Instrument 2 through (max.) 10: VEGATOR 620 switched to passive mode Sensor + - + - + - + - + - + - VEGATOR 620 622 VEGATOR 620 VEGATOR 620 (active) (passive) (passive) Instrument 1 Instrument 2... through... (max.) instrument 10 As the above extension example shows, it is possible to control several signal conditioning instruments with one sensor in order to detect different levels. This wiring layout can be extended to include 10 instruments (loop current). 12 VEGATOR 620 622

Setup 4 Setup 4.1 Indicating and adjustment elements 4 4 4 max. 9 0 10 1 1 min. min. 10 0 10 0 10 0 10 8 2 3 on 2 3 on! 2 3 on! 8 VEGATOR 620 6 7 8 VEGATOR 621 VEGATOR 622 6 6 6 6 7 8 6 7 8 9 10 11 12 13 14 7 9 10 11 12 13 14 7 9 10 11 12 13 14 7 View, laterally on top 11 12 1 Potentiometer for switching point adjustment 2 Status indication of the outputs 3 LED, supply voltage 4 Separating wall Terminals, inputs 6 Terminals, transistor output 7 Terminals, supply voltage and relay output 8 LED, fault signal 9 Potentiometer for max. switching point 10 Potentiometer for min. switching point ;;;;;;; ;;;;;;; ;;;;;;; ;;;;;;; ;;;;;;; ;;;;;;; ;;;;;;; ;;;;;;; 13 14 11 Bar code, serial number 12 DIL switch block 13 Screws 14 Ventilation opening 1 Transparent cover 1 VEGATOR 620 622 13

Setup Potentiometer The potentiometers (1, 9 and 10), allow continuous adjustment of the switching points. Signal lamps Green (3) - supply voltage available - ready for operation Yellow (2) - status indication of the relay and transistor outputs LED lights (relay energised, transistor conductive), LED extinguished (relay deenergised, transistor blocked) Red (8) - failure indication DIL switch block (12) When VEGATOR is installed, the terminal socket covers the DIL switch block. Adjustments are only possible when the instrument is dismounted. VEGATOR 620 VEGATOR 621, 622 off B 12 6 t sec 2 ze za A 12 t sec 6 2 ze za A The individual switches are assigned as follows: - switch A/B: mode switch A - max. detection (overfill protection) B - min. detection (dry run protection) - switch ze and za ze - switch on delay za - switch off delay - switch 2, 6, 12 With these you can adjust the delay time. The time intervals of the activated time switches sum up. When the on delay/off delay switches are switched on together, the set time is valid for both delay modes (see the following table). off B Switch on/off Switch delay za ze 2 6 12 0,2 s off off off off off 0,3 s on on off off off 2 s on on on off off 6 s on on off on off 8 s on on on on off 12 s on on off of on 14 s on on on off on 18 s on on off on on 20 s on on on on on 4.2 Setup sequence The following list explains briefly the essential setup steps - mount the terminal socket - wire the terminal socket according to your control requirements - cover the input terminals with the separating wall (4) - set the requested mode (A/B) on the DIL switch block (12) - deactivate the on delay/off delay modes (switches ze, za, 2, 6, 12 to position off ) on the DIL switch block (12) - mount the instrument module onto the terminal socket - switch on the power supply, the green LED (3) lights - adjust the switching points acc. to 4.3 Switching point adjustment - if an integration time (on delay/ off delay) should be necessary, the instrument must be removed again to set the time on the DIL switch block (12). 14 VEGATOR 620 622

Setup 4.3 Switching point adjustment Adjustment example 1, mode A (overfill protection) - VEGATOR 620, 621 - single point control - sensors: vertically mounted measuring probes, hydrostatic pressure transmitters or process pressure transmitters Adjustment example 2, mode B (dry run protection) - VEGATOR 620, 621 - single point control - sensors: horizontally mounted capacitive meas. probes or capacitive meas. probes for adhesive products Capacitive meas. probes Process pressure transmitters Capacitive meas. probes Procedure Set the potentiometer (1) to 0. Fill the vessel up to 100 mm below the electrode. Hydrostatic pressure transmitters Level/Pressure 100 mm Switching point Mode A Mode B t Rel. Transistor conductive blocked 12 13 14 12 13 14 conductive blocked Procedure Set the potentiometer (1) to 10. Fill the vessel up to the requested level or pressure. Turn the potentiometer (1) very slowly anticlockwise until the status indication (2) changes, i.e. the status indication extinguishes. The signal conditioning instrument is now ready for operation. Please close with the transparent cover (1). Turn the potentiometer (1) very slowly clockwise until the status indication (2) changes, i.e. lights in mode A, extinguishes in mode B. Note the dial position of the potentiometers (1). Continue filling the vessel until the measuring probe is completely covered. With measuring probes for adhesive products, the sensitive tip must be covered completely (standard 100 mm above the electrode). The status indication (2) changes due to the additional filling. 100 mm VEGATOR 620 622 1

Setup Turn the potentiometer (1) very slowly clockwise until the status indication (2) changes, i.e. lights in mode A, extinguishes in mode B. Note the position of the potentiometer. Determine the average value and adjust it on the potentiometer (1). The signal conditioning instrument is now ready for operation. Please close with the transparent cover (1). The relay and transistor output as well as the status indication behave in mode A and B as previously shown in Adjustment example 1, see top left. Procedure Set the potentiometers (1) of the two signal conditioning instruments to 10. Fill the vessel up to level 1. Turn the potentiometer (1) of the first VE- GATOR very slowly anticlockwise until the status indication (2) changes, i.e. lights in mode B, extinguishes in mode A. Now fill the vessel up to level 2. Now turn the potentiometer (1) of the second VEGATOR very slowly anticlockwise until the status indication (2) changes, i.e. lights in mode B, extinguishes in mode A. The two signal conditioning instruments are now ready for operation. Please close each with the transparent cover (1). Adjustment example 3 - two VEGATOR 620 - as dual single point control (see 3.3 Connection plans, extension example ) - vertically mounted capacitive measuring probes Adjustment example 4 - VEGATOR 622 - double point control - sensors: vertically mounted capacitive meas. probes or hydrostatic pressure transmitters Level 2 2nd VEGATOR Level 1 1st VEGATOR Max. level Min. level Level/Pressure Level/Pressure Switching points Level 2 Level 1 Switching points Max. level Min. level 2nd VEGATOR Mode A Mode B 1st VEGATOR Mode A t Rel. 12 13 14 12 13 14 12 13 14 Transistor conductive blocked conductive blocked conductive blocked Mode A Mode B t Rel. 12 13 14 12 13 14 Transistor conductive blocked conductive blocked Mode B 12 13 14 conductive blocked 16 VEGATOR 620 622

Setup / Diagnostics Procedure Set both potentiometers (9 and 10) to 0. Fill the vessel to min. level. Turn the min. potentiometer (10) very slowly clockwise until the status indication (2) changes, i.e. lights in mode A, extinguishes in mode B. Now turn the potentiometer (9) to 10. Continue filling the vessel to max. level, the status indication (2) remains unchanged. Turn the max. potentiometer (9) very slowly anticlockwise until the status indication (2) changes, i.e. extinguishes in mode A, lights in mode B. The signal conditioning instrument is now ready for operation. Please close with the transparent cover (1). Note: VEGATOR 622 can also be used for single point control. The max. potentiometer must be set to 0, the min. potentiometer then acts as single point adjustment. Diagnostics.1 Maintenance The instrument is maintenance free..2 Repair Repairs require accessing internal parts of the instrument to correct an instrument defect. For safety and warranty reasons, repair must only be carried out by qualified VEGA personnel. In case of a defect, please return respective instrument with a short description of the flaw to our repair department. Failures are short-term malfunctions caused by wrong adjustment or defects in the sensor or in the connection cables. Failures, their possible causes and their rectification are listed under.3 Failure rectification. VEGATOR 620 622 17

Diagnostics.3 Failure rectification Failure Instrument is dead/ Green operating lamp extinguishes VEGATOR 620 functions incorrectly or not at all Red failure LED of VEGATOR 621 or 622 lights Rectification / Measure Check the voltage supply and the mains connections as described under Connection instructions. If the instrument still does not function, please call our service department. Check the sensor inputs for the following failures: - short-circuit on the input - sensor not connected correctly or polarity-reversed - sensor line interrupted - supply voltage too low Check if the sensor is connected correctly. - failures in the sensor, effecting a current change to below 2 ma or above 23 ma, generate a fault signal on VEGATOR. 4 20 ma ma V 1 18 V (24 V with VEGATOR 620) Measure the current in the connection cable to the sensor. + - VEGATOR 12 3 4 For Ex systems, make sure that the Ex protection is not degraded by the measuring instruments. a. Current value < 2 ma - Check the supply voltage on the connection cable to the sensor. The voltage should be at least 17 V. Should a value below 17 V be measured, it indicates a defect in the signal conditioning instrument. In this case, return the instrument for repair to VEGA. - If at least 17 V are available, separate the signal conditioning instrument from the connection cable and connect to the sensor input of the signal conditioning instrument a resistor of 2.2 kohm. If the failure lamp continues to light, the signal conditioning instrument is defective. In such a case, return the instrument for repair to VEGA. - Should the failure lamp extinguish, reconnect the signal conditioning instrument. Separate the sensor from the connection cable and connect a resistor of 2.2 kohm in its place. - Should the failure lamp continue to light, there is probably an interruption of the connection line. Check the connection cable to the sensor. - If the failure lamp extinguishes, the sensor is defective. Check the connected sensor. 18 VEGATOR 620 622

Diagnostics Failure Rectification / Measure VEGATOR 620 functions incorrectly or not at all Red failure LED of VEGATOR 621 or 622 lights b. Current value > 22 ma - Check all connections and the connection cable to the sensor. - Should the red failure lamp continue to light, separate the sensor from the connection cable and connect a resistor of 2.2 kohm in its place. If the failure lamp extinguishes, the sensor is defective. Check the connected sensor. - Should the failure lamp continue to light, reconnect the sensor. Separate the signal conditioning instrument from the connection cable and connect a resistor of 2.2 kohm to its sensor input. - Should the failure lamp continue to light, the signal conditioning instrument is defective. In such a case, return the instrument for repair to VEGA. - If the failure lamp extinguishes, there is probably a short circuit in the connection line. Check the connection cable to the sensor. Note: A flawlessly operating VEGATOR has the following switching point values: Potentiometer position Sensor current 0 approx. 4 ma approx. 12. ma 10 approx. 21 ma VEGATOR 620 622 19

VEGA Grieshaber KG Am Hohenstein 113 77761 Schiltach/Germany Phone +49 (0) 7836 0-0 Fax +49 (0) 7836 0-201 E-Mail info@de.vega.com www.vega.com ISO 9001 The statements on types, application, use and operating conditions of the sensors and processing systems correspond to the latest information at the time of printing. Technical data subject to alterations 2.19 90 / July 2001