METHODS IN OPERATIONAL TRANSMISSION POWER GRID

Similar documents
ASSESSMENT OF MEDIUM VOLTAGE EQUIPMENT OPERATIONAL RELIABILITY WITH IN THE MANAGEMENT OF BRASOV SDEE

IMPLEMENTATION OF ADVANCED DISTRIBUTION AUTOMATION IN U.S.A. UTILITIES

Texas Reliability Entity Event Analysis. Event: May 8, 2011 Loss of Multiple Elements Category 1a Event

Electric Power Quality Monitoring and Analysis at a Tri-generation Plant under Development

Power Quality Permanent Monitoring Systems in Romania

Life Cycle Management of Station Equipment & Apparatus Interest Group (LCMSEA) Getting Started with an Asset Management Program (Continued)

Power Quality Control on The Romanian Energy Market

METHODS AND PRINCIPLES OF OPTIMIZATION SPECIFIC TO THE DOMAIN OF EQUIPMENT AND MANUFACTURING PROCESSES

Power System Stability. Course Notes PART-1

Power transformers. Shunt reactors Proven history for future success

Single Line Diagram of Substations

MEDIUM & HIGH VOLTAGE

Survey of Operational Events

Transmission System Phase Backup Protection

LOW LEVEL CURRENTS AND VOLTAGES MEASUREMENTS

METHODS AND PRINCIPLES OF OPTIMIZATION SPECIFIC TO THE DOMAIN OF EQUIPMENTS AND MANUFACTURING PROCESSES

Unit 2. Single Line Diagram of Substations

ANSE VISUAL, developed within the

INPUT MODELLING USING STATISTICAL DISTRIBUTIONS AND ARENA SOFTWARE

ISO Rules Part 500 Facilities Division 502 Technical Requirements Section SCADA Technical and Operating Requirements

Transmission Availability Data System Phase II Final Report

PRC Generator Relay Loadability. Guidelines and Technical Basis Draft 4: (June 10, 2013) Page 1 of 75

Anti-IslandingStrategyforaPVPowerPlant

Instrumentation and Control

FACULTATEA DE INGINERIE ELECTRICĂ. Ing. Lucian Diodiu. PHD Thesis ABSTRACT

EH2741 Communication and Control in Electric Power Systems Lecture 2

PRC Generator Relay Loadability. Guidelines and Technical Basis Draft 5: (August 2, 2013) Page 1 of 76

Module 10. Initiation Code RELIABILITY ACCOUNTABILITY

Geoff Brown & Associates Ltd

Combination of Adaptive and Intelligent Load Shedding Techniques for Distribution Network

Transformer energisation after network blackout

Ferroresonance Experience in UK: Simulations and Measurements

ISO Rules Part 500 Facilities Division 502 Technical Requirements Section SCADA Technical and Operating Requirements

ESB National Grid Transmission Planning Criteria

RESEARCHES ON QUALITY MANAGEMENT IN THE FIELD OF KNITWEAR INDUSTRY

THE USE OF PASSIVE CURRENT LIMITERS, A MODERN ALTERNATIVE AND EFFICIENT ALTERNATIVE TO REACTORS

1

Condition-based maintenance of power transformers Complete three-phase system Turns Ratio: Recovery Voltage: Winding Resistance:

Partial Discharge Measurements on 110kV Current Transformers. Case Study. Results

INCIDENTS CLASSIFICATION SCALE METHODOLOGY

Phase Shifter Application Workshop. Siemens Energy, Inc.

E S C R I P T I V E B U L L E T I N .,.,.,. Bulletin DB-106. October, Square D Company Power System Studies ---1 I SQU ARED COMPANY --

Short-Circuit Apparent Power of System Survey Comments

Robert W. Cummings - NERC Director of System Analysis and Reliability Initiatives William Herbsleb - Chairman of Frequency Response Standard Drafting

Reliability Guideline: Generating Unit Operations During Complete Loss of Communications

Capacitor protection relay

Stability Issues of Smart Grid Transmission Line Switching

Grounding System Theory and Practice

Reliability Guideline: Generating Unit Operations During Complete Loss of Communications

Hamdy Faramawy Senior Application Specialist ABB Sweden

TRAINING Learning and Training application on site. QUALIFYING Evaluation of quiz Knowledge Validation To learn required skills

A New Approach for Transformer Bushing Monitoring. Emilio Morales Technical Application Specialist Qualitrol

Substation Testing and Commissioning: Power Transformer Through Fault Test

SUSTAINABILITY OF RESEARCH CENTRES IN RELATION TO GENERAL AND ACTUAL RISKS

Case Study Survey of Harmonic Pollution Generated by Railway Systems and Filtering Solutions

Nauticus (Propulsion) - the modern survey scheme for machinery

Process Equipment Troubleshooting

Voltage Sags Evaluating Methods, Power Quality and Voltage Sags Assessment regarding Voltage Dip Immunity of Equipment

UNIT-III LIFE-CYCLE PHASES

Bruce L. Graves /01/$ IEEE. IEEE Industry Applications Magazine PhotoDisc, Inc.

Specify Gain and Phase Margins on All Your Loops

Blackout Theory. EE8725 Apoorva Mysore Nataraja

CHAPTER 8 Effect of HT Distribution Feeder Voltage on Distribution Transformer Losses

Substation: From the Outside Looking In.

Computer Control System Application for Electrical Engineering and Electrical Automation

Development of Recommended Practices for Audio Frequency Track Circuits. Robert A. MacDonald Director of Systems Engineering B&C Transit Oakland, CA

CONTENTS. 1. Introduction Generating Stations 9 40

Artificial Island Proposal Window

European Nuclear Education Network Association

System and equipment for measurement, registration of parameters and analyse of the quality of the electric energy

Appendix D Fault Levels

THE POWER OF TRANSMISSION ENERGY

System grounding of wind farm medium voltage cable grids

Electrical and Automation Engineering, Fall 2018 Spring 2019, modules and courses inside modules.

SYNCHRONISING AND VOLTAGE SELECTION

ATCO ELECTRIC LTD. (Transmission System) SERVICE QUALITY AND RELIABILITY PERFORMANCE, MEASURES AND INDICES Revision 0

DUKE ENERGY CAROLINAS TRANSMISSION SYSTEM PLANNING GUIDELINES. Transmission Planning

Dynamic Analysis of Electronic Devices' Power Signatures

GridLiance Reliability Criteria

Electrical Equipment Condition Assessment

MEASUREMENT OF THE PARAMETERS FOR ELECTRIC ENERGY QUALITY. (1) Gabriel VLADUT, (2) Petre-Marian NICOLAE

25 The Choice of Forms in Licensing Agreements: Case Study of the Petrochemical Industry

Integration of Wind Generation into Weak Grids

Experiences of Using Synchrophasors at Duke Energy

AUTOMATED MEASUREMENT SETUP FOR MICROCONTROLLERS AND MAGNETIC SENSORS

Standard Development Timeline

The Role of Effective Parameters in Automatic Load-Shedding Regarding Deficit of Active Power in a Power System

Appendix S: PROTECTION ALTERNATIVES FOR VARIOUS GENERATOR CONFIGURATIONS

THE IMPACT OF NETWORK SPLITTING ON FAULT LEVELS AND OTHER PERFORMANCE MEASURES

Publishing date: 23/07/2015 Document title: We appreciate your feedback. Share this document

Contents. 1 Introduction Assessment criteria Assessment Recommendations References... 8

Functional Range. Synchronising Relay : UN1, FN2, SY1, SY/SP. C&S Protection & Control Ltd.

REMOTE LABORATORY: HOW TO RENDER LESS VIRTUAL AS POSSIBLE THE MEET WITH THE INSTRUMENTATION

ROBOT DESIGN AND DIGITAL CONTROL

Experimental Investigations and Calculations in 6-35 kv Networks with Various Neutral Conditions

(Circuits Subject to Requirements R1 R5) Generator Owner with load-responsive phase protection systems as described in

The Polytransformer. The Multivoltage Substation Power Transformer

NETWORK INNOVATION COMPETITION ANGLE-DC PROJECT HOLISTIC CIRCUIT CONDITION MONITORING SYSTEM REPORT

A Study on Ferroresonance Mitigation Techniques for Power Transformer

Research on State Estimation and Information Processing Method for Intelligent Substation

Transcription:

METHODS IN OPERATIONAL TRANSMISSION POWER GRID DANIEL MORAR, Romania NC Transelectrica, Sibiu Transmission Subsidiary, 154 Ştefan cel Mare str., Sibiu, 550321, +40269207142, daniel.morar@transelectrica.ro BASARAB GUZUN, University Politehnica Bucharest, Energy Power and Utility Dept., 131 Spaiul Independenţei str., Bucharest, 060042, +40214029401, guzunbasarabdan@yahoo.com Abstract: The paper present the methods propose by the authors to be applied in operating of the substations. The substations take in consideration was rehabilitates by replace the existing equipments to new equipments made in the last generation. The substations take in consideration, also are change there architecture itself. The methods for the implementation of new equipments are issue. The technical difficulty in operational power grid and there resolution is present. The rehabilitated substations require new methods to complete the operational substations tasks. The method expose are the operational reliability. The mathematic methods and new analyses methods for resolve the operational substations tasks are issue. The analysis methods take in consideration the operational reliability, the technical parameters of equipments and those variations in operation, the importance of the equipments parameters, the statistics and the reliability and the specific parameters. The behavior of the equipments all over the operation time is analysis and was giving the solution for the future operation. The result of this research is use in the several applications. The local example for this application on a substation is issue. The elasticity of several type of the system architecture is analyzed. In the paper is answer the question how opportune is to make live maintenance to high voltage equipments. Key words: Operational methods, Power 1. INTRODUCTION The high voltage power networks, operating activities undergoing a transition from equipment and systems whose life is exhausted in new equipment and systems. Mining activity is booming and follows a Quality Plan, which is a modern policy of quality, environmental protection and operational safety and health. As part of the application of probability theory is still operating at the beginning, is hardly applicable due to small number of technical information that can be collected from the network. By upgrading facilities to start a new period, this will build new technical databases. Such databases will be created for new equipment will be useful only if they are created by a guide and will form the basis of applying the modern theory of probability. In this context the authors propose a method of operation based on information provided by probability theory. 2. EQUIPMENT BEHAVIOR THROUGHOUT LIFE Plant operation means all activities undertaken using the best conditions and the useful capacity of high voltage equipment, high voltage equipment tracking behavior and prevention of damage due to improper use, avoidance of high voltage equipment failures that could lose power system stability and security and a weakening carried. Avoiding high-voltage equipment failure during operation is the target pursued within operating activities. This requires knowledge of parameters affecting the operation of the equipment. Only partial knowledge of the technical parameters of high voltage equipment operated resulting in the need to estimate their evolution, their use more efficient and better operating activities. These estimates can be made using indicators of probability. Analyzes the records of accidental events in plants has been observed that these events have multiple causes. Thus the authors have classified these cases the following criteria: - Works with that equipment - Before its entry into service - Was in operation during the normal life of equipment - In service after the normal life of equipment - Found in the reserve - Operating times and seasons of the year with events - Type of error committed - Human error - User error - Technical error - defective equipment - Technical error - misuse the power grid - Technical error - error maintenance Activities affecting equipment were divided on stage investment. From analysis of the incident made the authors found that the causes of incidents can be classified as the period in which the error occurred, intervals that exactly suited investment stages. Investment stages we defined as: a) The request - is initially, the intention of making an investment b) The market - is leaving the market with investment, auctions c) The design - the design phase is 42

d) The production - the stage production is designed equipment e) The assembly - assembly equipment is used instead of c) The operation - is using a network equipment g) The maintenance and repairs - performing maintenance on equipment Table 1. Number of events analyzed plants Events OHL Substations Time AR fails primary system fails secondary system fails small problems Number of plants 3. THEORETICAL BASIS USED TO ANALYZE EVENTS During operation, the data acquired the equipment in service think that can be used to estimate the events. The authors were able to calculate: - Probability of good functioning of equipment - Probability of failure of equipment - Probability of an operation or failure - The probability of providing power to all consumers or energy requirement - Frequency of equipment failure - The probability of rapid and selective elimination of a defect - The probability of making revisions to a minimum delay - Intensity of damage - Failure intensity Probability calculations we have done with the following distribution functions: - Exponential - x E 1 e (1) - Weibull x W 1 e (2) We recommend that the choice of distribution functions to be made by each user and the functions chosen by the authors are not strict. Choice of distribution functions in an analysis depends on the type of analysis, equipment analysis and variation in time of incident. 5 years 717 629 88 4582 512 584 2486 206 In table 1 we show the number of events analyzed plants. Table 2 show the deviation from the ideal equipment and table 3 show the deviation from the ideal equipment on stage. Table 2. Deviation from the ideal equipment Equipment Total life cycle Circuit breakers 0,390 Disconnectors 0,372 Current transformers 0,378 Voltage transformers 0,373 Power transformers 0,410 Secondary systems 0,450 OHL 0,420 The graphics result from the table 3 are show in figure 1, 2, 3 and 4. Base on these results we calculate the behavior of systems. Table 3. Deviation from the ideal equipment on stage Plants The request The market The design The production 4. RESULTS The method was considered accidental events occurring in an electrical network for a period of 5 years and a volume of 206 plants. Substations 0,07 The assembly The operation OHL 0,10 0,14 0,09 0,42 0,88 0,40 0,76 43

Power transformers 0,07 0,12 0,09 0,41 0,82 The difference between the owner demand and the necessities and equipment acquisitioned appeared in demand and/or marketing steps. Secondary systems (SCPA) 0,11 0,04 0,15 0,11 0,45 0,91 During the operational time service of the equipment, several failures were experienced, having different causes, as: - data error - missing data, insufficient data or wrong data about the equipments (location, technical issue, fitting, operational and maintenance, quality, maintenance paper, other maintenance or operational service paper from Quality Plan, environmental plan, geological plan, other data etc.), Fig. 3. Transformers and autotransformers units evolution on live cycle Fig. 4. Secondary systems fron substation evolution on live cycle Fig. 1. OHL evolution on live cycle - setting error - data error about place, equipment parameters, error - communication, error demand etc, - fitting error, - operational error (overload, wrong maneuver, external cause, natural phenomenon, human error, planning error). Fig. 5. Deviation for secondary systems in time Fig. 2. Primary equipments from substations evolution on live cycle This error has the following causes: - demand, containing parameters which can't be come true; - demand (different) as needed by the substation; - demand incomplete; 44

- missing that very type of equipment on the market; - economic, unfavorable situation. The probability to appear failures must be known by the personnel of decision, in order to further improve the methods to be applied into the operational substation. Failure can appear during the operation of the substations and, the need for estimation is related with: - the break of the equipment, - lose the load, - late and non selective eliminated failures, - breaker failure action, - long time for maintenance, - lost the auxiliary transformer or without the self-start Diesel generator, - AR or break the OHL, - wrong actions of the equipment The equipment behavior under detailed analyses, was derived by using standard calculus for the operational reliability affected to a substation, seen as a system with different schemes and types of architecture. We did study how can be used the equipment in several type of architecture of the system, safer and economically. The study indicates which type of system architectures are the most profitably, from both points safety and economic. The data from the operational reliability calculus of the equipments, which was presented above, was used to calculate the reliability of the system (equipment gathered into the substation). We have taken into consideration the behavior of the system in relation to each kind of failure. The conclusions of the analysis on the system's types are: - can't function for long time with the equipment on the by-pass, - the grater reliability of a system belongs to the followings: - 1.5 circuit breaker type, - double type, - hexagonal type. For the installations reliability estimation (OHL, bay, power transformer, protection, auxiliaries services) were considered different system architectures. Table 4. The Reliability of the Systems No. System type Reliability, R (%) 1 simple - OHL - simple 0.36 2 simple - transformer - simple 0.34 5 double with by-pass - OHL - double with by-pass 6 double with by-pass - with by-pass 7 double - OHL - double with by-pass 8 double - with by-pass 9 1.5 circuit breaker - OHL - 1.5 circuit breaker 10 1.5 circuit breaker - OHL - double 11 1.5 circuit breaker - transformer - 1.5 circuit breaker 12 1.5 circuit breaker - with by-pass 13 hexagonal - OHL hexagonal 14 hexagonal - OHL - 1.5 circuit breaker 15 hexagonal - transformer hexagonal 16 hexagonal - 17 "H" system - "H" system 0.52 0.60 0.45 0.52 0.41 0.44 0.45 0.39 0.38 0.10 3 double - OHL - double 0.41 18 "H" system - OHL - 1.5 circuit breaker 0.21 4 double - 0.42 45

19 1.5 circuit breaker - "H" system - OHL - double 20 "H" system - cross function 21 "H" system - 2 OHL with 1 transformer 22 OHL in double with by-pass system in function on proper bay 23 OHL in double with by-pass system in function on by-pass 24 transformer in double with by-pass system in function on proper bay 25 transformer in double with by-pass system in function on by-pass 0.24 0.38 0.18 0.84 0.80 0.84 0.80 proved to be that of "double bus-bar, 3/2 circuit breaker" - type. Until the last year, this configuration was unique and was used only into the 400kV substation, devoted to the first Romanian nuclear power plant NPP Cernavodă, having great steam turbine-generator units, each rated 720MW, 24/400kV and 1500rpm. 5. CONCLUSION As far as the reliability offered by the substations, the work was focused mainly over the great achievements, quite recently erected and putted into operation. Other schemes were also analyzed, but because there were not considered representative, none comment was given herewith. In so doing, by comparing a lot of schemes, the results of the behavior of different systems over 5 years of operation are present into one condensed form shown. The second large substation in our country, refurbished at Sibiu Sud with the levels 20kV, 110kV, 220kV and 400kV; at the highest voltage levels, this substation is a vital linking node between southern part and the mid country s generating power plants, responsible at some extent for the NPG stable operation, as a whole. This selection stands also as a great achievement in the field we have already discussed above in this paper and does underline the conclusion of our study as being correct, sustained by the calculations given, which could be found into one condensed presentation 26 single OHL 0.79 27 double OHL 0.82 28 1.5 circuit breaker OHL 0.83 30 hexagonal OHL 0.81 31 OHL - transformer in "H" system 0.42 The assessment of the reliability of the systems we did consider the reliability of equipment in each hand, indicated also as the number of equipment failure. This information gives more insights when it is to compute as the deviation from ideal case and decrease the reliability in the operational time of the equipment, as seen in Table 4. Among the most convenient substations schemes system for reliable operation are "double bus-bar with by-pass - installations - double with by-pass " and "1.5 circuit breaker- installations - double with by-pass ". However, the most reliable system chosen, affordable also from the economic point of view into our country, REFERENCES [1]. NPG Transelectrica-SA, Raport anual, NPG Transelectrica- SA, pp. 15-19, Dec. 2009. [2]. NPG Transelectrica-SA, Raport anual, NPG Transelectrica- SA, pp. 15-19, Dec. 2008. [3]. I. Felea, N. Cheroiu Fiabilitatea şi mentenanţa echipamentelor electrice Oradea University Publishing House, 2001, p. 21-50. [4]. I. Felea, Ingineria fiabilităţii în electroenergetică. Bucharest Didactic and Pedagogic Publishing House, 1996, p. 15-150. [5]. A. Leca and co-authors, Principii de management energetic ET Bucharest Technical Publishing House, 1997, p. 15-250. [6]..SC Tehnorob, Estimarea duratei de viaţă a LEA 220-400kV din gestiunea ST Sibiu, SC Tehnorob, Bucharest, Tech. Rep.C12, Nov. 2007. [7]. D. Morar and B.D. Guzun, Optimum Methods for Power Grid s Operation, presented at the International World Energy System Conference - WESC, The Politehnica University from Iaşi, Romania, July 2008. [8]. D. Morar, Retehnologizarea staţiilor de înaltă tensiune, Ph.D. dissertation, The Politehnica University from Bucharest - PUB, The Faculty of Power Engineering, Power Generation & Use Chair Dept. Bucharest, 2003. [9]. D. Morar, Sisteme de protecţii pentru staţiile de înaltă tensiune, Ph.D. dissertation, The Politehnica University from Bucharest - PUB, The Faculty of Power Engineering, Power Generation & Use Chair Dept., 2004. [10]. D. Morar, Metode de optimizare a exploatării staţiilor de înaltă tensiune, Ph.D. dissertation, The Politehnica University from Bucharest - PUB, The Faculty of Power Engineering, Power Generation & Use Chair Dept. Bucharest, 2007. 46