Valve amplifier for proportional pressure valves

Similar documents
Valve amplifier for proportional directional valves and proportional pressure valves. Type VT-VSPA2-1. Features. Contents

Valve amplifier for proportional directional valves. Type VT-VRPA2. Features. Contents. RE Edition: Replaces: 07.05

Valve amplifier for proportional valves. Type VT-MSPA2-1. Contents. Features. RE Edition: Replaces:

Valve amplifier for proportional valves with electrical position feedback

Analog amplifier. RE 29926/10.06 Replaces: Type VT Component Series 3X

Valve amplifier for proportional pressure valves

Valve amplifier for high-response valves. Type VT-VRRA X/V0/2STV, VT-VRRA X/V0/PO-IS. Contents. Features

Valve amplifier for proportional valves. Type VT-SSPA1-1 (5, 50, 100, 150) Features. Contents. RE Edition: Replaces:

Analogue amplifier. Features. Table of contents. RE 29980/09.05 Replaces: Type VT-SR2. Series 1X 1/6

Electric amplifiers. Table of contents. Features. RE 30052/02.12 Replaces: Type VT-VRPA X/V0/... Component series 1X 1/6

Electric amplifier for flow control with proportional

Electric amplifiers. Table of contents. Features. RE 30054/03.12 Replaces: Type VT-VRPA X/...-RTP. Component series 1X 1/6

Electric amplifiers. Table of contents. Features. RE 30048/08.12 Replaces: Type VT-VRPA X/V0/RTP. Component series 1X 1/6

Plug-in amplifier. Table of contents. Features. RE 30264/07.12 Replaces: Type VT-SSPA1. Component series 2X 1/8

Booster amplifier. Table of contents. Features. RE 30260/04.12 Replaces: Type VT-MSFA1. Component series 1X 1/6

p/q closed-loop control amplifier

Digital Proportional Amplifier. Type: RT-VSPA2-50. Series: 3X. Table of contents. Features. RD13763/11.07 Replaces:

Electronic amplifier for the control of proportional valves without position control Model VT 3006, Series 3X H/A 4240/94 VT X

Electronic Amplifier Model VT 3017 and VT 3018 (Series 3X) for the control of proportional directional valves, without positional feedback

Electric amplifier for proportional cartridge throttle valves

Electronic amplifier for the control of proportional valves without position control Model VT 3024, Series 3X H/A 4149/94 VT X

Electric amplifiers. List of contents. Features. RE 30052/08.05 Replaces: Type VT-VRPA1. Unit series 1X 1/6

Directional control valves, direct operated, with electrical position feedback and integrated electronics (OBE)

Analogue amplifier modules for 4/3 and 4/2 proportional directional valves 4WRE

RT-5005/5006/5007/5008

RA / /6. Replaces: Table of contents RA /06.98

4/3 proportional directional valve direct operated, with integrated electronics

4/3 proportional directional valve with integrated digital electronics and field bus interface (IFB-P) Type 4WREF. Features.

External control electronics for the SYDFE1 control of the A10VSO axial piston variable displacement pump

High-response valve with integrated digital axis controller (IAC-R) and field bus interface

External control electronics for the SYDFE1 control of A10VSO axial piston pumps Analogue amplifier, configurable

External control electronics for the SYDEF1 adjustment of the A10VSO axial piston pump

Analog Amplifier RA. RE / /12 replaces: RE RE RE RE Technical Data Sheet

Analog amplifier RA. RE Edition: Replaces:

Directional control valves, direct operated, with electrical position feedback and integrated electronics (OBE)

DENISON HYDRAULICS Proportional Pressure Control Valves

External control electronics for the SYDFE1 control of the A10VSO axial piston variable displacement pump

Service case with test unit for servo and proportional valves with integral electronics (OBE)

Electric amplifiers. Table of contents. Features RA 30052/ Model VT-VRPA1. Series 1X 1/6

Directional control valve, direct operated, with integrated digital axis controller (IAC-Multi-Ethernet) Type 4WRPDH. Features.

4-Way Servo Valve Model 4 WS. 2 E , (Series 2X) with Mounting Pattern to DIN or CETOP RP 115 H PSI (315 bar) H/A 3012 H/A 3013

2-Way Proportional Logic Cartridge Valve Model FE.. (Series 1X and 2X) PSI (315 bar) F with electrical connection 12 X Y

Drive electronics pq11

Mobile dual solenoid driver

Product overview. Features. Product specifications. Order codes. 1kΩ Resistance Output Module

Accessories Power Amplifiers

ELECTRONIC REGULATOR FOR OPEN LOOP

Drive Electronics pq11

MDSD (Series 2X) Mobile Dual Solenoid Driver

Digital axis control HNC100

SAS-2 6Gbps PHY Specification

Proportional directional valves

Electronic regulator for PWM controlled proportional solenoid valves FABER -

Smart Power Relay E I...

Technical Documentation

Section 1, General information Introduction... 3 Description... 3 Specifications... 4 Wiring connections... 5

Digital amplifier for proportional valves PEM XD

Speed sensor DSA series 12

Operating Instruction

ISOMETER IRDH575. Approvals

Lock-In Amplifiers SR510 and SR530 Analog lock-in amplifiers

Directional control valve, direct operated, with integrated digital axis controller (IAC Multi Ethernet) Type 4WRPDH. Features.

Sensor technologies Proximity sensors Series ST9. Brochure

12 30 ripple included external fuse 3,0 A Current consumption A 1,0 2,6 depending from solenoid current. V ma. V ma. Output current A 1,0-1,6-2,6

Continental Hydraulics Installation Manual CEM-RA-A

Technical data. General specifications. Measurement range min max. 360

PHOENIX CONTACT - 03/2007

4/3-way fast response valve Type 4WRGE

Overexcitation protection function block description

Current consumption ma solenoid current consumption ( max 300 ma) Hz % V ma. Housing dimensions mm 120(d) x 99(h) x 23(w)

Fuse, external A 6A, medium time lag. Power consumption W min 20 - max 60 (see paragraph 5.2) Output current A maximum 4.5 (see paragraph 5.

This data sheet is only valid in association with the IL SYS INST UM E user manual.

Solid State Relays & Its

Analog position controller

MODEL AT-10 ANALOG TRANSMITTER

M224. M C bis. TYPE CODE M K Y 45 / 18 x 60 - / / / - #

Frequency converter. Frequency Converter Fe

Proportional Directional Control Valves Nominal sizes 16 and 25

Proportional Directional Control Valves Size 6

Continental Hydraulics Installation Manual CEM-PA-A

PCB relay for DC voltage, polarized, monostable or bistable

Electronic amplifier type EV1D

Directional valves Coils Series CO1. Brochure

Proportional amplifier type EV1M3

FREQUENCY SYNTHESIZERS, SIGNAL GENERATORS

Coils & Electronic Controls

ELECTRONIC THERMOSTAT: T920

TECHNICAL DATASHEET #TDAX A DC MOTOR CONTROLLER P/N: AX Variable Speed Control, Onboard I/O CAN SAE J1939, Rugged Packaging

FA-3300 Heavy Duty Electric Actuator. Features and Benefits. FA-3300 Actuator with VG8000 valve. Constant running time. Fixed close-off force.

MRS ELECTRONIC DATASHEET CAN I/O AND PLC DESCRIPTION TECHNICAL DATA REGULATORY APPROVALS AND TESTING SOFTWARE/PROGRAMMING

Controller. 1 Proportional amplifier module ESSK 103. ESSK 103 and ELSK Description. 1.2 Application examples. 1.

Owner s Manual S10 SERIES ELECTRONIC STEP CONTROLLER WITH VERNIER CONTROL

Servo Amplifier 4-Quadrant PWM for Brushless DC-Servomotors

Proportional Directional Control Valves Size 6

Original operating instructions Fail-safe inductive sensor GG507S / / 2013

Hydraulic Valve Interface Products

EPA-M*** POWER AMPLIFIER FOR OPEN LOOP PROPORTIONAL VALVES SERIES 20

Directional valves Electrically operated Series 563, 565, 567. Brochure

Electro-Hydraulic 4-Way Directional Servo Valve Model 4 WS 2 E.10 and 4 WSE 2 E. 10 (Series 4X) PSI (315 bar) K K

EFC 3600 Frequency converter for higher energy efficiency and improved process control

Transcription:

Valve ampliier or proportional pressure valves Type VT-VSPA1-2 RE 30115 Edition: 2013-09 Replaces: 2013-02 Component series 1X Analog, Euro-card ormat Suitable or controlling proportional pressure valves: DBET-6X, DBEM...-7X tb0185_d Features Contents Dierential input (0... +10 V) Current input (4... 20 ma) Ramp generator with separately adjustable ramp times "up/down" External ramp time presetting Enable input Clocked power output stage "Ready or operation" message Reverse polarity protection o the supply voltage Short-circuit protection and cable break detection o the solenoid conductor Features 1 Ordering code 2 Function 2 Block diagram 4 Setting and operating controls 5 Technical data 6 nit dimensions 7 Project planning inormation/maintenance instructions/ additional inormation 7

2/8 VT-VSPA1-2 Valve ampliier Ordering code 01 02 03 04 05 06 VT-VSPA1 2 1X / V0 / / * 01 Valve ampliier or proportional pressure valves, analog, Euro-card ormat VT-VSPA1 02 For controlling direct operated proportional pressure valves DBET-6X and DBEM...-7X 2 03 Component series 10 to 19 (10 to 19: nchanged technical data and pin assignment) 1X 04 Version: Standard V0 05 Option: Standard 0 Option: 4 command value call-ups A4 06 Further details in the plain text (additional unctions on request) * Accessories card holder VT 3002-1-2X/48F (see data sheet 29928) Function Power supply unit (1) The ampliier has a power supply unit with making current limiter. This unit supplies all internally required positive and negative supply voltages. Command value speciication (2), (3), (4) 1), (5), (6) The internal command value signal is calculated rom the total (6) o the external command value signal or the calledup signal (4) 1) available at the dierential input (2) or at the current input (3) and the zero point oset (5) (zero point potentiometer "Zw"). The ollowing applies: Standard values Current Dierential Command input input value socket 0 % 4 ma 0 V 0 V +100 % 20 ma +10 V +10 V There is no switch-over between current and voltage input. The inputs are permanently available (see block diagram). Command value call-ups (4) 1) Four command value call-ups "w1" to "w4" can be called up. The external voltages (command values 1 to 4) are either deined directly by the voltage output +10 V or by external potentiometers. I these command value inputs are directly connected to the regulated voltage, the command values are set at the potentiometers "w1" to "w4". When using external potentiometers, the internal potentiometers will unction as attenuators or limiters. Only one call-up can be operated at the same time. I several call-ups are operated simultaneously, call-up "w1" has the lowest priority and call-up "w4" has the highest priority. The active call-up is indicated by a yellow LED. Enable unction (7) The enable unction (7) enables the power output stage and orwards the internal command value signal to the ramp generator (8). The enable signal is indicated by an LED. I the release is connected (via 24 V input or jumper J1), the internal command value is changed (with any kind o command value speciication) by the set ramp time. Thus, a controlled valve does not open abruptly. Ramp generator (8) The ramp generator (8) limits the rise o the control output. The downstream amplitude limiter (12) does not extend or shorten the ramp time. sing the jumper J3, the ramp time is changed by the actor 10. The ollowing applies: J3 socket /V 2 1 0.2 0.1 0.02 * t/ms 50 100 500 1000 5000 t/s 0.5 1 5 10 50 * Basic setting (condition as supplied) 1) Only with option A4

Frequency in Hz * Valve ampliier VT-VSPA1-2 3/8 Formula: t = 100 ms socket / V Ramp on/o (9) sing jumper J2 or the "Ramp on/o" input (9) (see terminal assignment), the ramp time is set to a minimum (< 50 ms). An activated ramp is indicated by an LED. "Ramp on/o" input J2 LED "T" Ramp 0 V On On +24 V O O 0 V O O +24 V On On Ramp time setting external (10) sing an external potentiometer or an external voltage presetting (according to the ormula in section "Ramp generator"), the internally set ramp time can be extended. The setting can be veriied at the measuring sockets. In case o a cable break, the internal deault setting will be valid automatically. The ollowing applies to the external potentiometer: Setting range* R Min. ramp time (potentiometer at let turn) Max. ramp time (rotary angle o potentiometer at approx. 95 %) 1 kω 100 ms 1 s 100 Ω 1 s 10 s * The minimum ramp time can only be reached i the internally set ramp time is lower, i.e. the corresponding potentiometer is at the let turn. The speciied ramp times are true or J3 = open. Characteristic curve generator (11) The maximum current or the solenoid is set using the "Gw" (12) potentiometer. In the characteristic curve generator (11), the command value signal is changed so that a linear command value pressure characteristic curve (correction characteristic curve or DBET-6X and DBEM...-7X) results. For this purpose, jumper J4 has to be closed and jumper J5 has to be opened. In order to deactivate the correction characteristic curve, jumper J4 has to be opened and jumper 5 has to be closed. Amplitude limiter (12) The internal command value is limited to approx. +120 % o the nominal range. Command value output (13) 0 % 0 V +100 % +10 V A requency dependent on the command value signal is generated using the jumper J6 (or DBET-6X and DBEM...-7X). For a universal use, jumper J6 is to be opened. A requency adjustment via the "requency" potentiometer can be realized by means o jumper J7. Example 1: (requency adjustment via "requency" potentiometer without command value dependency; J6 = open, J7 = closed) Setting range: 210 Hz... 310 Hz ± 15 % Example 2: (command-value dependent requency J6 closed) 450 B 34 V 400 28 V 350 24 V 300 18 V 250 200 150 100 50 0 0 20 40 60 80 100 Command value in % * Tolerance: ±15 % Via the "requency" potentiometer, the requency can be corrected by > ±10 % (J6 and J7 closed). Power output stage (15) The power output stage creates a clocked solenoid current or the proportional valve. The output stage output is de-energized in case o an internal ault signal or i the release is missing. The output stage output is short-circuit-proo. Actual value output (16) 1 ma (I solenoid ) 1 mv (actual value output) Fault recognition (17) The solenoid conductor is monitored or cable break and short-circuits. I there is no ault, a voltage > 16 V is output at the "ready-or-operation" output and the "ready-or-operation" LED is illuminated. In case o a ault, the ollowing applies: Output LED Short-circuit Low O Cable break Clocking Flashing Clock generator (14) In the clock generator (14), a requency or the output stage is generated. The requency is inluenced by the supply voltage. RE 30115, edition: 2013-09, Bosch Rexroth AG

1 Power supply unit 7 Enable 13 Command value output 2 Dierential input 8 Ramp generator 14 Clock generator 3 Current input 9 Ramp on/o 15 Power output stage 4 Command value call-ups 10 Ramp time external 16 Actual value output 5 Zero point setting 11 Characteristic curve generator 17 Fault recognition 6 Command value summation 12 Amplitude limiter 4/8 VT-VSPA1-2 Valve ampliier Block diagram Ramp on/o Ramp time external + Command value 5: 0...+10 V Command value 6: 4...20 ma + + Command value 4 1) Command value 3 1) Command value 2 1) Command value 1 1) Command value call-up 4 1) Command value call-up 3 1) Command value call-up 2 1) Command value call-up 1 1) Enable 24 V 0 V 1) Only with option A4 b12 10 d24 d28 b14 b16 b22 b24 b8 b6 b4 b2 d8 d6 d4 d2 d18 z30 z32 +15V 10k >50k >50k I 100 100k 100k w4 w3 100k w2 100k J1-1 9 t< t> t< t> 2 3 6 w1 4 5 Zw w4 w3 w2 w1 7 8 L0 J2 Ramp time selection logics 8 Command value selection logics DC 1 DC up/down max t ok + 7,5 V + 10 V M0 7,5 V L 13 W J3 J3 8 T t ramp max/sec t 5 50 Gw 11 PWM requency J6 (z) ~ (z, y) J6 y (y, z) PWM z I L J7 12 15 J5 "requency" ok J4 14 16 I Enable Error detection & 17 ok L J8 Reserve jumper d30 z2 z4 d32 z10 d20 d22 b32 d26 b28 z20 Internal command value Solenoid Actual value Reserved Ready or operation +10 V/25 ma Reserved Reerence external System earth

Valve ampliier VT-VSPA1-2 5/8 Setting and operating controls Rexroth J3 J5 J2 "requency" potentiometer Ready or operation Enable Ramp activated Zw Gw w1 w2 w3 w4 t< t> Zero point calibration "Zw" Amplitude attenuator "Gw" Command value 1 "w1" 1) Command value 2 "w2" 1) Command value 3 "w3" 1) Command value 4 "w4" 1) Ramp up "t <" Ramp down "t >" J7 J6 J4 Name plate t< t> w I Measuring sockets VSPA1-2 1) Only with option A4 J8 J1 Fuse 2 A medium time-lag Measuring sockets t < Ramp time "Ramp up" t > Ramp time "Ramp down" w Command value output (0...10 V) I Actual value (1 mv 1 ma ) Clock requency o the output stage Reerence or outputs Additional potentiometer "requency" Frequency setting (to be activated using J7) LED T w1-w4 Ready-or-operation LED Enable LED ("enable") "Ramp on active" LED "Command value call-up" LEDs (only with A4 variant) Jumpers J1 J2 J3 J4 J5 J6 J7 J8 Reserve jumper = Jumper condition as supplied No enabled Enable activated Ramp unction on/o ( = open) (see table under "Ramp on/o" on page 3) Ramp time 20 ms... 5 s Ramp time 200 ms... 50 s Command value pressure characteristic curve correction inactive Command value pressure characteristic curve correction active Command value pressure characteristic curve correction active Command value pressure characteristic curve correction inactive Command value-dependent requency deactivated Command value-dependent requency activated (or DBET-6X and DBEM...-7X) Frequency adjustment via "requency" potentiometer deactivated Frequency adjustment via "requency" potentiometer activated J4 and J5 must not be simultaneously closed. RE 30115, edition: 2013-09, Bosch Rexroth AG

6/8 VT-VSPA1-2 Valve ampliier Technical data (or applications outside these parameters, please consult us!) Operating voltage B 24 VDC + 40 % 20 % Operating range pper limit value u B (t) max 35 V Lower limit value u B (t) min 18 V Power consumption P S < 24 VA Current consumption I < 2 A Fuse I S 2 A medium time-lag, exchangeable Inputs, analog Command values 1 to 4 (potentiometer inputs) * e 0... +10 V, R e > 100 kω Dierential input e 0... +10 V, R e > 50 kω Current input I e 4... 20 ma, load R B = 100 Ω Ramp time external e 0... +5 V, R e > 10 kω Inputs, digital Command value call-ups (only with option A4) 8.5 V... B > call-up operated, R e > 100 kω 0... 6.5 V > no call-up, R e > 100 kω Ramp on/o 8.5 V... B > ramp on, R e > 100 kω 0 V... 6.5 V > ramp o, R e > 100 kω Release 8.5 V... B > ON, R e > 100 kω 0... 6.5 V > OFF, R e > 100 kω Clock requency 250 Hz ± 10 % (J6 and J7 = open) Setting ranges Zero adjustment (potentiometer "Zw") +30 % Command values (potentiometers "w1" to "w4") 0... 100 % Ramp times (potentiometer "t <" and "t >") t 20 ms... 5 s, switchable to 0.2 s... 50 s Amplitude attenuator (potentiometer "Gw") 0... +120 % Frequency adjustment with "requency" potentiometer (J7 operated) See explanation: Clock generator, page 3 Outputs Command value signal 0... +10 V ± 2 %, I max = 2 ma Actual value signal 0... +10 V ± 2 %, I max = 2 ma Ready or operation high: >16 V, I max = 50 ma low: <1 V Regulated voltage +10 V ± 2 %, I max = 25 ma, short-circuit-proo Ramp signals measuring socket +100 mv... +5 V ± 10 %, +10 mv... +100 mv ± 50 % Power output stage I 0... 1.9 A, short-circuit-proo, clocked Type o connection 48-pin male multipoint connector, DIN 41612, design F Card dimensions Euro-card 100 x 160 mm, DIN 41494 Operating temperature range ϑ 0... 50 C Storage temperature range ϑ 25...+85 C Weight m 0.15 kg (net)

Valve ampliier VT-VSPA1-2 7/8 nit dimensions (dimensions in mm) Rexroth Zw Gw w1 3HE (128,4) w2 w3 w4 t< t> 89 100 t< t> w VSPA1-2 4TE (20,3) Ø8 2 165 182 7 Project planning inormation/maintenance instructions/additional inormation In the condition as supplied the parameters are set as ollows: Correction characteristic curve and command valuedependent requency = active (or valves DBET-6X and DBEM...-7X), max. ramp time = 5 s, pilot current = 100 ma, max. output current = 1.6 A. The ampliier card may only be assembled when de-energized. No connectors with ree-wheeling diodes or LED displays must be used or the solenoid connection. Only carry out measurements at the card using instruments R i > 100 kω. For switching command values, relays with gold-plated contacts have to be used (small voltages, low currents). Always shield command value lines, connect shielding to earth on the card-side, other side open. I no system earth exists, connect 0 V operating voltage. Recommendation: Shield solenoid conductors as well. For solenoid conductors up to 50 m in length, use the line type LiYCY 1.5 mm 2. With greater lengths, please contact us. The distance to aerial lines, radios, and radar systems has to be 1 m at least. Do not lay solenoid conductors and signal lines near power lines. I the dierential input is used, both inputs must always be connected or disconnected at the same time. RE 30115, edition: 2013-09, Bosch Rexroth AG

8/8 VT-VSPA1-2 Valve ampliier Notes Bosch Rexroth AG Hydraulics Zum Eisengießer 1 97816 Lohr am Main, Germany Phone +49 (0) 93 52 / 18-0 documentation@boschrexroth.de www.boschrexroth.de This document, as well as the data, speciications and other inormation set orth in it, are the exclusive property o Bosch Rexroth AG. It may not be reproduced or given to third parties without its consent The data speciied above only serve to describe the product. No statements concerning a certain condition or suitability or a certain application can be derived rom our inormation. The inormation given does not release the user rom the obligation o own judgment and veriication. It must be remembered that our products are subject to a natural process o wear and aging.