ISIS A beginner s guide

Similar documents
Guide to Processing Spectra Using the BASS Software

Demetra User documentation DC0029A

Image Processing Tutorial Basic Concepts

Instruction Manual for HyperScan Spectrometer

SARG: The Graphical User Interface Manual

NIRSPEC Data Reduction Pipeline Data Products Specification

Information for users of the SOAR Goodman Spectrograph Multi-Object Slit (MOS) mode. César Briceño and Sean Points

Importing and processing gel images

DBSP Observing Manual

ThermaViz. Operating Manual. The Innovative Two-Wavelength Imaging Pyrometer

PixInsight Workflow. Revision 1.2 March 2017

CHROMACAL User Guide (v 1.1) User Guide

SBIG ASTRONOMICAL INSTRUMENTS

VATTSpec Instructions Rev. 10/23/2015

Brightness and Contrast Control Reference Guide

ToupSky Cameras Quick-guide

Module 2: Radial-Line Sheet-Metal 3D Modeling and 2D Pattern Development: Right Cone (Regular, Frustum, and Truncated)

AgilEye Manual Version 2.0 February 28, 2007

ScanArray Overview. Principle of Operation. Instrument Components

Geometric Functions. The color channel toolbar buttons are disabled.

Guidance on Using Scanning Software: Part 5. Epson Scan

Leica TCS SP8 Quick Start Guide

R I T. Title: Wyko RST Plus. Semiconductor & Microsystems Fabrication Laboratory Revision: A Rev Date: 05/23/06 1 SCOPE 2 REFERENCE DOCUMENTS

32 Float v3 Quick Start Guide. AUTHORED BY ANTHONY HERNANDEZ (415)

Operating Rausch ScanCam within POSM.

APO TripleSpecTool User's Guide

Working With Drawing Views-I

Adobe Photoshop. Levels

ImagesPlus Basic Interface Operation

MY ASTROPHOTOGRAPHY WORKFLOW Scott J. Davis June 21, 2012

Picture Style Editor Ver Instruction Manual

Basic Hyperspectral Analysis Tutorial

T I P S F O R I M P R O V I N G I M A G E Q U A L I T Y O N O Z O F O O T A G E

Alibre Design Tutorial: Loft, Extrude, & Revolve Cut Loft-Tube-1

6. Very low level processing (radiometric calibration)

Scanning Setup Guide for TWAIN Datasource

Stitching MetroPro Application

Quintic Software Tutorial 7c

Picture Style Editor Ver Instruction Manual

The ideal K-12 science microscope solution. User Guide. for use with the Nova5000

Leica TCS SP8 Quick Start Guide

i800 Series Scanners Image Processing Guide User s Guide A-61510

Goodman Cookbook. Goodman Spectrograph. Adapted by D. Sanmartim from L. Fraga's Guide. Sep SOAR Telescope

APO TripleSpecTool User s Guide

AstroImageJ User Guide

User Guide for TWAIN / DirectX interface for GRYPHAX USB 3.0 cameras

inphoto ID PS Automatic ID photography With Canon PowerShot camera User Guide

Introduction to QTO. Objectives of QTO. Getting Started. Requirements. Creating a Bill of Quantities. Updating an existing Bill of Quantities

Picture Style Editor Ver Instruction Manual

User Manual for HoloStudio M4 2.5 with HoloMonitor M4. Phase Holographic Imaging

Manual Stitching of Multiple Images to Produce a Panorama

i1800 Series Scanners

Cerro Tololo Inter-American Observatory. CHIRON manual. A. Tokovinin Version 2. May 25, 2011 (manual.pdf)

Introduction to Autodesk Inventor for F1 in Schools (Australian Version)

Visioneer OneTouch Scanner. Installation Guide FOR WINDOWS

Leica DMi8A Quick Guide

We recommend downloading the latest core installer for our software from our website. This can be found at:

Photoshop CC Editing Images

Microscopy from Carl Zeiss

A Stony Brook Student s Guide to Using CCDSoft By Stephanie Zajac Last Updated: 3 February 2012

Blab Gallery Uploads: How to Reduce and/or Rotate Your Photo Last edited 11/20/2016

ScanGear CS-U 5.3 for CanoScan FB630U/FB636U Color Image Scanner User s Guide

5. SilverFast Tools Tools SilverFast Manual. 5. SilverFast Tools Image Auto-Adjust (Auto-Gradation) 114

The user should already be familiar with operation of the instrument in STEM mode, use of the Microscope Control interface, and TIA.

Exercise 4-1 Image Exploration

Applying mathematics to digital image processing using a spreadsheet

WFC3 TV3 Testing: IR Channel Nonlinearity Correction

Enhancement of Multispectral Images and Vegetation Indices

Infinity Software Manual

v Introduction Images Import images in a variety of formats and register the images to a coordinate projection WMS Tutorials Time minutes

Overview. About other software. Administrator password. 58. UltraVIEW VoX Getting Started Guide

FoamWorks Introduction. David Mrozinski 848 W. Borton Road Essexville, Michigan 48732

Topaz Labs DeNoise 3 Review By Dennis Goulet. The Problem

NOISEWARE 5 USER'S GUIDE PLUG-IN BY IMAGENOMIC

User Guide V10 SP1 Addendum

JEOL 6500 User Manual

A Guide to AstroImageJ Differential Photometry

262 The Astrophotography Manual. Templates

inphoto ID SLR Automatic ID photography With Canon SLR camera User Guide

FLDIGI Users Manual: WEFAX

Standard Operating Procedure

7. RECTIFICATION (GEOMETRIC CORRECTION) OF IMAGES AND RESAMPLING

Zoom Set Too Tight Zoom Set Correctly Zoom Set Too Wide

This procedure assumes the user is already familiar with basic operation of the SEM and the MiraTC interface.

LA-T LED ANALYSER EVALUATION KIT INSTRUCTION MANUAL. rev

Renishaw InVia Raman microscope

Unit 2: Smiley Basics Student Guide. Derek Dennis

MEASUREMENT CAMERA USER GUIDE

OzE Field Modules. OzE School. Quick reference pages OzE Main Opening Screen OzE Process Data OzE Order Entry OzE Preview School Promotion Checklist

A guide to SalsaJ. This guide gives step-by-step instructions on how to use SalsaJ to carry out basic data analysis on astronomical data files.

truepixa Chromantis Operating Guide

32 Float v2 Quick Start Guide. AUTHORED BY ANTHONY HERNANDEZ - (415)

Benchtop System Quick Start

For customers in USA This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions:

F/48 Slit Spectroscopy

Southern African Large Telescope. RSS CCD Geometry

Quick Start for Autodesk Inventor

Editing your digital images:

ScanMate. i920 Scanner. Scanning Setup Guide for TWAIN Applications A-61733

XTcalc: MOSFIRE Exposure Time Calculator v2.3

Transcription:

ISIS A beginner s guide Conceived of and written by Christian Buil, ISIS is a powerful astronomical spectral processing application that can appear daunting to first time users. While designed as a comprehensive pipeline for end- to- end spectral image processing, ISIS includes many advanced features that can be disregarded while becoming familiar with basic profile creation. The following beginner s guide provides a basic workflow for producing a calibrated spectral profile from a set of target and calibration images. Important this guide assumes that target and neon images have been bias and dark corrected. Functionality in ISIS for creating and applying master bias, flat and dark frames has been deliberately omitted from this guide to keep things as basic as possible. 1 File organisation ISIS utilises file organisation conventions designed to streamline processing of new spectra. It is important to take time to ensure that directory organisation and file naming requirements are understood and applied before processing files with ISIS. 1.1 Directory structure To begin with, it is assumed that you have acquired a number of spectral images in FITs format of a specific target and target wavelength and taken sequentially together with one or more calibration frames (normally a neon lamp calibration image acquired before, during or after a sequence of target images). It is best to store all images and calibration frames under a single directory. ISIS has been optimised to use a single working directory structure for file access and data output for each object and target wavelength acquired on a particular night. 1.2 File naming File conventions for spectral images in ISIS require a consistent file name and numerical sequence. A highly suggested approach is to employ a hyphen between file name and sequence number, e.g: image- 1.fit image- 2.fit image- 3.fit For example, if you have been acquiring spectra of eta Carinae on a particular night, you might have a list of images similar to the following: 1

C:\20140715\etacar- 1.fit etacar- 2.fit etacar- 3.fit etacar- 12.fit It is recommended that the same convention be used for neon calibration images. If you have acquired only one calibration image, consider naming it in a similar fashion, eg: C:\20140715\neonetacar- 1.fit If you ve taken neon calibration images before, during and after the target sequence, you might consider naming your neon calibration images as follows: C:\20140715\neonetacar- 1.fit neonetacar- 2.fit neonetacar- 3.fit (the before image) (the mid image) (the after image) Tip: ISIS includes a tool for converting MaxIM DL formatted numbering to ISIS numbering - see appendix A for information. 2

2 Using ISIS Section 2 provides a suggested sequence for first time processing of a sequence of spectral images in order to create a calibrated profile. It includes details on determining the spectral dispersion coefficients required for calibrating images acquired by non- Shelyak instruments. 2.1 Settings The Settings page (shown in Figure 1) serves two main purposes: Specification of default program settings. Setting the location of files for a particular session. 1 2 3 4 6 5 Figure 1: The ISIS Settings Page Descriptions of the numbered fields highlighted in Figure 1 are as follows: 1. Spectrograph model Unless you use and interchange a number of different Shelyak instruments, this field only needs to be set once. For non- Shelyak slit spectroscopes such as the JTW Spectra- L200, select LHIRES III. 3

2. Working directory Specify the location of files you wish to work on for a particular session. ISIS returns to the previously specified location on start up, so the working directory generally needs to be redefined at the commencement of processing newly acquired spectra. Organising your data by date is highly recommended. 3. Spectral database directory The spectral database directory is the location where you have installed the required database files. These can be downloaded from the ISIS web site and should be installed at the same time as ISIS. 4. GNUPLOT software directory (optional) GNUPLOT is used to create publishable plots and is optional. Leave this field blank if you have not installed GNUPLOT. 5. Observatory Specify your observatory longitude, latitude and altitude. 6. Spectral domain for profile scaling This is where the wavelength range used for flux normalisation is specified. The values chosen depend on the target characteristics and wavelength range of your spectra and can be changed at any stage during profile creation. If you are unsure, just choose a small featureless range that sits within the wavelength limits of your spectra for now. Other fields Check the language and FITs extension details. Leave the other fields set at their defaults for now. 4

3 Preparing for calibration Spectral dispersion coefficients need to be determined prior to target image calibration. This step is particularly relevant for non- Shelyak instruments. Dispersion coefficients are calculated using measurements undertaken on the neon calibration image taken as part of a target sequence. Once determined, the spectral dispersion coefficients remain active, even if ISIS is restarted. There are two steps to this process. 3.1 Extract a raw spectral profile from the neon calibration image. To extract a raw spectral profile from your neon image, go to the Tools page and select Spectra processing 2. 1 2 3 Figure 2: Extracting a raw spectral profile from the neon image Enter the name of your calibration image (omitting the extension) next to Image name. Enter a name for what will become the raw spectral file next to Profile name. Press Go. A DAT file will be created in the default directory in the example above neonetacar.dat. 5

3.2 Determine the spectral dispersion Select the Profile page in ISIS. ISIS beginner s guide. Version 2.0, September 2014 Figure 3: An uncalibrated neon profile Using the Open File button, select and open the previously created DAT file. An uncalibrated profile of your neon image will appear on the display. Select the Dispersion button to open the Compute spectral dispersion dialogue. If it is populated with values, press Reset. Figure 4: Spectral dispersion dialogue 6

The procedure at this point is to select features on the calibration profile by double clicking on each side of known emissions. ISIS automatically populates the dispersion dialogue with a precise x value. Enter the corresponding wavelength and repeat for other lines. Tip: Choose from the drop down list of magnification factors on the profile page to zoom in on the profile. Figure 5: Double click on each side of a feature and enter the wavelength Once the table is complete, the dispersion coefficients can be computed using a number of selectable polynomial functions before pressing the Compute polynom button. Finally, press Calibration to compute the coefficients and enter them into ISIS. A calibrated neon profile appears as a check and can be saved as an option. Though also not required, the lines list and polynomial information can also be saved prior to exiting the dispersion dialogue. Spectral dispersion has now been calculated and incorporated into the current project and is retained even after restarting ISIS. This feature streamlines spectral processing at the same target wavelength range on subsequent nights. In addition, the calculated spectral dispersion for this project can be reused for new projects of the same target wavelength and resolution. Appendix C and D outline the XML features present in ISIS that provide for this. 7

4 General The General page provides a home base for the commencement of a typical session. It may appear confusing at first, so observe the following sequence carefully: 1 2 6 3 4 8 5 9 7 Figure 6: The ISIS General page 1. Using the file selection box adjacent to Root name, navigate to and open the first image file in your sequence using the previous example this would be, etacar- 1.fits. 2. Press the Auto button. 3. The yellow fields will be automatically populated with Generic name, Number and Calibration according to defined prefix and suffix preferences (bottom right on the General page). 4. ISIS will automatically detect the number of images according to the sequence naming convention. Check that the number of images matches what you expect. 5. Check that the file name listed next to Calibration matches your calibration file. If it doesn t, you can select the file manually using the file selection box. The example in Figure 2 assumes we are using only ONE calibration image, acquired before the target sequence. Tip: See appendix B for information on how to combine calibration frames. 6. Enter a descriptive Object name of your choosing. It is best to use an official designation to take advantage of advanced features in ISIS (not covered in this basic guide). 8

7. Under general parameters, ensure that pixel size matches the pixel size of your images, not your camera. For example, if you imaged at bin2, enter double that of your camera s pixel size. 8. Select Predefined dispersion equation under Spectral calibration. The previously determined dispersion coefficients will be used. 9. Enter instrument, site and observer details according to your requirements. Important: This basic guide assumes images that have already been bias and dark corrected. As a consequence, ensure that the Offset, Dark and Flat entries are empty. Finally, and as an option, edit the object and calibration prefixes and suffixes to match your desired file naming convention, keeping in mind the suggested hyphenated numerical standard used in ISIS. The file name prefix and suffix preferences are what ISIS used when you clicked on Auto in step 2, so you can experiment with these to see what ISIS finds (or doesn t find). Note all file names selected or entered into ISIS are done so with the extension omitted. 9

5 Calibration The final steps in producing a calibrated profile of the target are as follows: 1. Select the Calibration page in ISIS. 2. Use the brightness and contrast sliders to adjust the image so that the spectra is visible. 3. Using the mouse, select a rectangular region along the width of the spectra and press Tilt. The tilt value will automatically appear adjacent to Tilt angle (Figure 7). Figure 7: Adjusting for tilt 10

4. Activate Graticule and configure the spectrum binning and sky evaluation zones. The dialogue is self explanatory and takes little practice to master. Figure 8: Setting binning and sky evaluation zones Tip: If necessary, the spectrum can be manually centred within the binning zone by un- checking the Auto vertical coordinate function box and then double clicking on the centre of the spectrum. 11

5. Display the neon calibration image and using the mouse, drag a vertical box around a single line to encapsulate an area for slant calculation. Press Slant to automatically populate the Slant angle field with the calculated value. Figure 9: Adjusting for slant and then setting x coordinate of reference wavelength Finally, set the X coordinate of line at wavelength entry. This is important to ensure that your dispersion coefficient is applied correctly to target calibration. It is accomplished by double clicking the cursor on a known line where it intersects the horizontal graticule and entering the associated wavelength in the adjacent box. ISIS will compute this coordinate to a precise value during execution. 6 Creating the profile Select the Go page in ISIS. Press the Go button. The sequence of processing steps will appear on the output display. When complete, press the Display profile button to reveal the calibrated spectral profile of your target. At this stage, the profile has not yet been corrected for instrument response. In order for IR correction to be included, an instrument response file needs to be generated, and then specified on the General page prior to processing the target spectra. This is covered in the next section. 12

Figure 10: Processing the spectra The profile can be saved before exiting ISIS. Figure 11: The calibrated profile (non IR corrected) 13

7 Instrument response correction ISIS beginner s guide. Version 2.0, September 2014 Reference star images to be used for instrument response correction are nominally acquired during the same imaging run as the target spectra, and reside in the same directory. 7.1 Create a calibrated profile of the reference star Step one in correcting for instrument response (IR) requires the creation of a calibrated profile of a chosen reference star and follows the same procedure previously outlined for processing target spectra. Because the reference star has been acquired at the same wavelength range and resolution, spectral dispersion does not need to be recalculated. The General page shown in Figure 12 has been updated to reflect the file name of the reference star and associated calibration frame acquired on the same night as the target spectra. Reference star images reside in the same directory as target images and use a similar naming convention. All other settings including those on the Settings tab remain unaltered. To keep things simple, this example also assumes that the files have already been bias and dark corrected. Accordingly, the yellow offset, dark and flat dialogues appear empty in Figure 12. Figure 12: General settings for the reference star (gamma Centauri) Follow the steps in section 5 and 6 to create a calibrated profile of the reference star. Instrument response curve generation begins with the profile active in the Profile display, as shown in Figure 13. 14

Figure 13: The calibrated profile of the reference star 7.2 Load a standard reference spectra. Step two of IR creation is to load a standard reference spectra. Note: It is beyond the scope of this basic guide to provide a explanation of reference spectra and catalogues for IR correction. Some knowledge of spectral standards and reference catalogues is assumed. Selecting the Response button on the Profile page initiates the ISIS reference spectrum selection dialogue. The example in Figure 14 shows an A0III star selected from the Miles catalogue. 15

Figure 14: The ISIS reference spectrum dialogue Click Select. This will return you to the instrument response dialogue, and the profile display will update, showing the target (blue), reference (red) and ratio (green). Figure 15: Target, reference and ratio profiles Pressing OK will exit the dialogue presenting just the ratio, or instrument response in blue. 16

Figure 16: Instrument response ratio Important: Use the Crop tool to remove any rapid drop of intensity to zero that may exist at extreme ends of the spectra. 7.3 Creating a smoothed instrument response curve The final step involves some subjectivity in producing a prototype instrument response curve, and this guide is by no means an expert example. The following summarises the basic sequence of steps: 1. Select the Continuum button. 2. Select out the major absorption features by double clicking on either side of these features (Figure 17). 3. Experiment with the continuum dialogue controls to create a smooth curve that matches the instrument response profile (Figure 18). Some practice may be required. More detailed information on IR computation can be found at Christian Buil s web site: http://www.astrosurf.com/buil/isis/guide_response/method.htm 17

Figure 17: Selecting out the major absorption features Figure 18: Using the controls on the continuum adjustment tool to create a smoothed IR curve 18

4. Save the profile with a name that allows it to be easily identified as an IR profile. Figure 19: Save the IR profile 7.4 Applying Instrument Response Correcting for IR once a response profile has been created and saved involves nothing more than referencing the IR profile on the General page before processing the target (Figure 20). 19

Figure 20: Specifying the IR profile to be used as instrument response for a target. Compare the profile in Figure 21 to the uncorrected profile on page 13. Figure 21: IR corrected profile Congratulations! You have just produced a calibrated and IR corrected profile using ISIS. 20

Appendix A Converting MaxIM DL sequence numbering to ISIS ISIS includes numerous and powerful tools for analysing and investigating image files. One of the simpler of these is a file sequencing tool that can be used to convert the file numbering used by MaxIM DL, to that required by ISIS. Figure 20 shows the intuitive interface, accessed from the Misc page. Enter the original name (omitting the extension) and check the image number box to verify that the files are found. Then enter an output name appended with a hyphen. Press Go to activate the conversion. The original files are preserved. Figure 22: MaxIM DL to ISIS file numbering conversion 21

Appendix B Averaging calibration frames ISIS beginner s guide. Version 2.0, September 2014 The Masters page includes a generic mean image computation tool that can be used to create an average of several calibration frames. Figure 23 shows the tool being used to create a mean neon image from 3 images obtained before, during and after the target sequence. In order for the tool to work, the individual files must be named using the ISIS numbering convention: neonetacarinae_heii- 1.fit neonetacarinae_heii- 2.fit neonetacarinae_heii- 3.fit As with all functions in ISIS, the final image is automatically saved to the default folder. Figure 23: Computing the mean from several images If you intend to use this new mean image to calibrate your target spectra, ensure that you select it as the calibration image on the General page. 22

Appendix C Advanced features ISIS beginner s guide. Version 2.0, September 2014 ISIS is an extremely powerful spectral processing package. A few examples include: Bias, dark and flat field correction ISIS includes sophisticated bias (offset), dark and flat field correction algorithms that include detailed auditing in the fits header and log files. A logical progression from basic use of ISIS is to incorporate image reduction within the ISIS pipeline. This is particularly important in the application of spectroscopic flat fields. XML data All settings and processing steps used in a project are automatically saved in an XML file stored in the default project directory. These files can be reloaded using the file access button adjacent to Root name on the General page. Appendix D provides information on how this feature can be used to process spectra of the same target and wavelength range on subsequent nights, without the need to recompute spectral dispersion coefficients and perform many other initial settings. Optimal binning and Wavelength registration The General page includes two checkboxes optimal binning and wavelength registration that can be used to improve the weighted vertical summing of spectra and the resolution respectively. Wavelength registration aligns all images in a sequence to the first image. As such it can be wise to ensure that the calibration frame used is one taken adjacent to the first target image in an otherwise long sequence. Interpolator type and Addition mode Experiment with these two options, available on the Settings page, to see if the appearance of a noisy profile can be improved. Refer to information on Christian Buil s web site for a thorough explanation of these and other advanced features in a variety of excellent documents: http://www.astrosurf.com/buil/isis/isis_en.htm 23

ISIS repeat target processing - quick reference guide 1. General - Load the XML file from a project that shares the same spectral dispersion. responsegamcent 2. Settings - Navigate to the Working directory of the new project. 24

3. General navigate to and select the Root name of the new image sequence and press Auto check and if necessary change Object name check the result for Generic name and Number check and if necessary modify Calibration file select the instrument response file (after copying to root directory) check status of other General parameters, including Wavelength registration etacar 1 2 eta Carinae etacar neonetacar-1 responsegamcent 25

4. Calibration check image to process and calibration image file names. cycle through images (quick check) check vertical position and graticule settings perform Tilt adjustment on target image perform Slant adjustment on calibration image check and adjust X coordinate of line at wavelength 5. Go Press Go Select Display Profile Crop and Save 26