Thermostat P. Thermostats Electronic room thermostat with clock for thermal actuators

Similar documents
Radiocontrol F. Floor Heating Controller Radio control system for floor heating

INSTAT 868 Radio Frequency Single-Room Controls

TA-Slider 160. Actuators Digitally confi gurable proportional push actuator 160/200 N

PRODUCT CATALOGUE TEMPERATURE CONTROL Grässlin products for individual control of temperature

Technical data. Functional safety related parameters MTTF d. Transfer characteristics. Time delay before availability. Standard conformity

Rotational speed controller

NRT 105: Electronic fan-coil controller, equiflex

SERVICE-MANUAL ROOM TEMPERATURE CONTROLLER NEA 230V / 24V. Construction Automotive Industry

Room Temperature Controllers. for heating and cooling systems

E N SHT-1 SHT-1/2 SHT-3 SHT-3/2

STR-LCF. Security Advice Caution. Notes on Disposal. Electronic Fan Coil Thermostat (Flush mounting) Datasheet. Application

Use of the application program. Contents. 1. Functional description General. GAMMA instabus Application program description.

RAMSES 784 HF Set 1. Bedienungsanleitung Uhrenthermostat 1. Operating Instructions Clockthermostat 14. Mode d emploi Thermostat à horloge 26

Use of the application program. Contents. 1. Functional description General. GAMMA instabus Application program description.

Room Temperature Controllers. for heating and cooling systems

EIB/KNX Switch Actuators. User manual

Control solutions Biofloor

Self-learning Room Temperature Controller Receiver

LK Wireless Room Control Cq

Fan Coil Actuator FCA 2

R7426A. MicroniK 200 TEMPERATURE CONTROLLER WITH AND WITHOUT REAL-TIME CLOCK

theben Fan Coil Actuator FCA 1 Fan Coil Actuator FCA 1 FCA Version: Jan-08 (Subject to change) Page 1 of 77

43.019/1. NRT 300: Electronic controller for air-conditioning (heating/cooling) Sauter Components

Room Temperature Controllers. for heating and cooling systems

TC 204 Heating Controller

Room Temperature Controllers. for heating and cooling systems

User Instructions For TopTronic RS-10

Use of the application program. Contents. instabus EIB Application program description. September S2 Room temperature controller

DeltaSol MX. Certifi ed for the North American market! CONTROL TECHNOLOGY. incl.

Power supply CP-D 24/4.2 Primary switch mode power supply

Sauter Components

NRT 300: Electronic air-conditioning controller, heating/cooling, equiflex

Room thermostat solo, FM Type: 6124-xx

SeeTool - Solutions for KNX

TA-Slider 160 KNX Protocol Implementation

ELECTRONIC THERMOSTAT: T951

Communicative heating controller

TAC 2112 Manual (GB),

K-BUS Switch Actuator

Radio controllers. Innovation combined with skill and tradition. Intelligent solutions. for all living spaces. Radio-controlled regulation

TA-Slider 160 KNX R24 Protocol Implementation

Operating Instruction

1: White buttons Used by the user on a daily basis. 2: Grey buttons Used only upon first startup.

R7420B. MicroniK 100 HONEYWELL TEMPERATURE CONTROLLER PRODUCT DATA GENERAL FEATURES

ELECTRONIC THERMOSTAT: T920

Room Temperature Controllers. for heating and cooling systems

Please enter the identity code of your device here!

WHEN A PLC IS TOO MUCH, AND SPACE FOR

ECB-103 BACnet B-ASC 10-Point Programmable Controllers

B850 Boiler House Energy Monitor

Electronic Circuit Breaker ESS20-0..

Time Switch, 2-channel, MDRC SW/S 2.5, GH Q R0001

CM927 WIRELESS PROGRAMMABLE THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

Universal Controller

PCB Relays Single Relays

Power supply CP-D 24/1.3

Application Programs Descriptions

APPENDIX APPENDIX A 1

Conductivity Transmitter N-LF V AC

Pulse Scaler for DIN Rail Attachment

MOTION DETECTOR WITH CONSTANT LIGHT CONTROL DM KNT 003

Operating Instructions

SRC-110 Series Zone Controllers with Modbus RTU

Room Temperature Controller with Built-in Room Sensor 1 Feb 2002

Overview per day of the programmed switching times 5 = Friday. Channel statuses / OFF

DIN Rail Time & Twilight Switches

Analogue temperature controllers

High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals

Electromotoric actuators

RAM 712 KNX room thermostat for surface-mounted and flush-mounted installation

Changing settings in the BlueSolar MPPT Charge Controllers

DATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection

Automatic synchronising relay

Power supply CP-D 12/2.1

Count - counters 5. Selection guide 5 XBK T81030U33E RC XBK RC XBK T60000U00M XBK T60000U11M XBK T80000U00M XBK T70000U00M 5/2

Please enter the identity code of your device here!

Multifunction Devices CIM1, CIM12, CIM13, CIM14

The room thermostat application module with 2-fold switch sensor is placed on a flush-mounted bus coupler.

DATASHEET - ETR4-51-A. Delivery program. Technical data General. Timing relay, star-delta, 50 ms, 1W, 3-60s, VAC/DC

Type CP-S, CP-C & CP-A Switch mode

Wireless multizone receiver RDE-MZ6

KNX ENO 620/622 (32-channel AP)

TLC3-BCR-U Series Thermostat

OPERATING INSTRUCTIONS Digital weekly time switch

Honeywell. W7620 Zone Controller Water Source Heat Pump A. GENERAL RESIDENTIAL AND BUILDING CONTROL GUIDE SPECIFICATION FOR THE ENGINEER

B850 Boiler House Energy Monitor

4TCD1. Digital 7-Day Programmable Timer. Installation Instructions. Tel Fax Schneider Electric (Australia) Pty Ltd

ORDERING CODE Z-WAVE FREQUENCY COUNTRY/REGION

ODEN AT Primary Current Injection Test System

Instruction manual. art Installation manual

Device connection and commissioning can only be carried out by qualified professionals. Always make the connections while the power is switched off.

Smart Power Relay E I...

200 RTH OFF ON IN OUT ALARM RESET

Servomotor for butterfly valves VF, VFH. delta-elektrogas.com EE157-01/16

16-Channel Yearly Time Switch TR 648 S DCF

Please enter the identity code of your device here!

Sentry Digital Timers

ABB conductivity analyzer and probe package

Preset counters, electronic

Bulletin 700-HX Multifunction Digital Timing Relay

Transcription:

Thermostat P Thermostats Electronic room thermostat with clock for thermal actuators

IMI HEIMEIER / Thermostats & Actuators / Thermostat P Thermostat P The Thermostat P room temperature controller is used in connection with the corresponding actuators in the fields of heating, ventilation and air-conditioning technology. For time-dependent individual room temperature control, the Thermostat P is used for e. g. residential and commercial buildings with radiators, floor heating systems, ceiling cooling systems or blower convectors etc.. Key features > > Time-dependent room temperature control > > Electronic two-point room thermostat with built-in sensor > > Pulsewidth modulation output signal (PWM) > > Models with analog or digital switch clock Technical description The Thermostat P is an electronic two-point room thermostat with built-in sensor and is used in connection with e. g. thermal actuators for time-dependent room temperature control with operating modes only heating or only cooling. With its pulsewidth modulation output signal (PWM), it has an almost constant control behaviour, internally adjustable on two-point output signal. The model with analog switch clock makes it possible to create a weekly program by positioning the switch tabs. Depending on the program, it switches between two operating modes, (day mode and night mode). The corresponding setting value can be set between 5 C and 30 C. An operating mode switch makes it possible to select between day, night or automatic mode. The model has control lamps for the heating, cooling or night mode operating state. With a separate switch clock output, additional room temperature controllers with temperature set-back inputs can be controlled. The models with digital switch clock are menu-driven via four buttons. The display shows the current room temperature, time and operating modes. The internal real-time clock is equipped with an automatic daylight saving. Time programs with weekly or daily program. Three time programs are preset and changeable. The temperature is adjustable between 7 C and 32 C. The temperature is achieved due to the self-learning heating curve at the selected time. Models with 230 V operating voltage with potential-free changeover contact. The Thermostat P is designed for installation on the wall or on recessed (concealed) switch boxes. 2

Construction Thermostat P with digital switch clock Daily / Weekly programs (changeable) Real-time clock, automatic summer/winter time changeover Self-learning heating curve Large display Operating voltage 230 V 1. Selection / display of day 2. Temperature display 3. Button +/- to change the values 4. Button for operating modes, etc. 5. Selection / display operating modes, etc.. Display of time Thermostat P with analog switch clock Individual weekly program Very simple switching time setting with switch tabs Adjustable restriction of the setting range Operating voltage 230 V Switch clock output for additional room thermostats 1. Operating mode switch 2. Time switch tabs 3. Heating mode control lamp 4. Night mode control lamp 5. Setting value adjuster for normal temperature (range constriction in the inside of the adjuster). Setting value adjuster for nighttime reduction 3

IMI HEIMEIER / Thermostats & Actuators / Thermostat P Function The measured room air temperature (xi) is compared to the set setting value (xs). The resulting deviations are converted into a two-point signal and, via electronic switches, control the potential-free relay with change-over contacts. The heating or cooling operating modes are triggered depending on the change-over contact configuration. The pulse-width modulated (PWM) output signal of the controller, as adjusted in the works, switches with differently long pulses. The length of the pulses depends upon difference between the set and the actual room air temperature. The sum (duration) of the time and interval (pause) can be adjusted by a pluggable contact bridge (jumper) to operate with 10 min. for fast systems or with 25 min for slow systems (please see functional diagram). For large temperature differences, the controller switches permanently on or off, e. g. during the transition to temperature set-back. If the adjustment is made to a two-point output signal, the output causes switching-on if the temperature falls below the set value and if this set value is surpassed the output causes switching-off. Functional diagrams for the operating mode heating in conjunction with an actuator in the version currentless closed PWM (pulse-width modulared) output signal Two-point output signal (1932) Duty rate Progression of the switch-on duration (duty rate) depending upon the temperature. *) Stroke **) Room temperature Application The Thermostat P room temperature controller is used in connection with the corresponding actuators (e.g. EMO T or EMOtec) in the fields of heating, ventilation and air-conditioning technology. For time-dependent individual room temperature control, the Thermostat P is used for e. g. residential and commercial buildings with radiators, floor heating systems, ceiling cooling systems or blower convectors etc.. In case of a two-point output signal adjustment of the controller further fields of application can be served, e.g on/off switching operations for pumps or gas-fired circulation hot water boilers. 4

Connection diagrams *) Note: Additional room thermostats with temperature set-back function can be connected to terminal 28. 5

IMI HEIMEIER / Thermostats & Actuators / Thermostat P Technical data Thermostat P with analog switch clock with digital switch clock Operating voltage: 230 V AC (+10 % / -15 %); 50/0 Hz 230 V AC (+10 % / -15 %); 50/0 Hz Power consumption: max. 1,5 VA. max. 3 VA) Switch relay /-connection 1 change-over relay, pot.-free * ) / screw 1 change-over relay, pot.-free / screw Voltage / Current AC 230 V / 10 ma 1 (4) A AC 230 V / 10 ma 1 (2) A Max. number of EMO T / EMOtec 10 pieces (230 V) 10 pieces (230 V) Clock function (default):. /. Real time with autom. S / W - time changeover Time program, grid / power reserve: 7 days (weekly program), 1 h / approx. 100 h 7 days / 5:2 days / 24 h, 1 min / undetachably Number of switching programs, -times 24 mechanical switching segments / day 3 preset (changeable), 2, 4 or / day (undetachably) Special Features timing clock output (max. 20 x TA-inputs) Optimum Start, holiday-/party-timer Temperature range (day/night mode): 5 C 30 C 7 C - 32 C (digital, in 0.1 K - steps) Control behaviour: PWM, adjustable to two-point behaviour PWM PWM cycle duration, -proportional band 10 / 25 min (adjustable); approx. 1.5 K 10 / 25 min (adjustable); approx. 1.5 K Hysteresis (2-point operating mode): approx. 0.5 K to 10 A, approx. 2.5 K at 1 A approx. 0.5 K to 10 A, approx. 2.5 K at 1 A Operating modes: heating or cooling heating or cooling Operating mode switch, - display: night / auto / day, LED heating-/set back mode menu with keys, LCD Temperature sensor / valve protection: internal. /. internal / switchable Type of protection; - class IP 30 (EN 0529); II (DIN EN 0730) IP 30 (EN 0529); II (DIN EN 0730) CE certification (EMC/L.T): DIN EN 0730-1 DIN EN 0730-1 Storage-/ ambient temperature: -25 C +5 C / -10 C +40 C -20 C +85 C / 0 C +40 C Body, color, dimensions (W x H x D [mm]): ABS white RAL 9010, 10 x 80 x 3 ABS white RAL 9010, 137 x 97 x 32 Installation: wall mounting or on recessed box (concealed) wall mounting or on recessed box (concealed) *) the above does not warrent or fullfil possible requirements of protective low tension (no secure disconnection).

2 5 Articles With digital switch clock Model EAN Article No 230 V 40240527310 1932-01.500 4 With analog switch clock 9 3 3 C 7 1 15 25 10 30 Model EAN Article No 230 V 40240524057 1932-00.500 Dimensions 80 9,5 137 31,3 10 0 3 1 mm = 0,0394 inch 7

IMI HEIMEIER / Thermostats & Actuators / Thermostat P The products, texts, photographs, graphics and diagrams in this document may be subject to alteration by IMI Hydronic Engineering without prior notice or reasons being given. For the most up to date information about our products and specifications, please visit www.imi-hydronic.com. 2200-.483 Thermostat P ed.2 10.2017