arxiv: v1 [physics.ins-det] 25 Oct 2012

Similar documents
ATLAS Muon Trigger and Readout Considerations. Yasuyuki Horii Nagoya University on Behalf of the ATLAS Muon Collaboration

Design and Construction of Large Size Micromegas Chambers for the ATLAS Phase-1 upgrade of the Muon Spectrometer

Performance of the ATLAS Muon Trigger in Run I and Upgrades for Run II

Upgrade of the ATLAS Thin Gap Chamber Electronics for HL-LHC. Yasuyuki Horii, Nagoya University, on Behalf of the ATLAS Muon Collaboration

Spectrometer cavern background

THE LHC is expected to be upgraded to the HL-LHC

Development and Test of a Demonstrator for a First-Level Muon Trigger based on the Precision Drift Tube Chambers for ATLAS at HL-LHC

Construction and Performance of the stgc and MicroMegas chambers for ATLAS NSW Upgrade

arxiv: v2 [physics.ins-det] 13 Oct 2015

Trigger Rate Dependence and Gas Mixture of MRPC for the LEPS2 Experiment at SPring-8

Development of large readout area, high time resolution RPCs for LEPS2 at SPring-8

CMS RPC HL-LHC upgrade with fast timing detectors

PoS(EPS-HEP2017)476. The CMS Tracker upgrade for HL-LHC. Sudha Ahuja on behalf of the CMS Collaboration

Development of a Highly Selective First-Level Muon Trigger for ATLAS at HL-LHC Exploiting Precision Muon Drift-Tube Data

Operation and performance of the CMS Resistive Plate Chambers during LHC run II

The Compact Muon Solenoid Experiment. Conference Report. Mailing address: CMS CERN, CH-1211 GENEVA 23, Switzerland

Aging studies for the CMS RPC system

The Compact Muon Solenoid Experiment. Conference Report. Mailing address: CMS CERN, CH-1211 GENEVA 23, Switzerland

The CMS Muon Detector

Current Status of ATLAS Endcap Muon Trigger System

Silicon Sensor and Detector Developments for the CMS Tracker Upgrade

Hardware Trigger Processor for the MDT System

irpc upgrade project for CMS during HL-LHC program

Construction and Performance of the stgc and Micromegas chambers for ATLAS NSW Upgrade

1 Detector simulation

The 1st Result of Global Commissioning of the ATALS Endcap Muon Trigger System in ATLAS Cavern

arxiv: v2 [physics.ins-det] 20 Oct 2008

Operation and Performance of the ATLAS Level-1 Calorimeter and Level-1 Topological Triggers in Run 2 at the LHC

Hardware Trigger Processor for the MDT System

The trigger system of the muon spectrometer of the ALICE experiment at the LHC

What do the experiments want?

The Multigap RPC: The Time-of-Flight Detector for the ALICE experiment

Measurement of the charged particle density with the ATLAS detector: First data at vs = 0.9, 2.36 and 7 TeV Kayl, M.S.

arxiv: v1 [physics.ins-det] 26 Nov 2015

8.882 LHC Physics. Detectors: Muons. [Lecture 11, March 11, 2009] Experimental Methods and Measurements

The CMS electromagnetic calorimeter barrel upgrade for High-Luminosity LHC

Phase 1 upgrade of the CMS pixel detector

Design and Performance of the ATLAS Muon Detector Control System

PoS(LHCP2018)031. ATLAS Forward Proton Detector

The CMS Outer HCAL SiPM Upgrade.

Expected Performance of the ATLAS Inner Tracker at the High-Luminosity LHC

The Status of ATLAS. Xin Wu, University of Geneva On behalf of the ATLAS collaboration. X. Wu, HCP2009, Evian, 17/11/09 ATL-GEN-SLIDE

The Compact Muon Solenoid Experiment. Conference Report. Mailing address: CMS CERN, CH-1211 GENEVA 23, Switzerland. CMS detector performance.

Track Triggers for ATLAS

Performance studies of large-area triple-gem prototypes for future upgrades of the CMS forward muon system

CMS Paper. Performance of CMS Muon Reconstruction in Cosmic-Ray Events. arxiv: v2 [physics.ins-det] 29 Jan The CMS Collaboration

Tracking and Alignment in the CMS detector

Pixel sensors with different pitch layouts for ATLAS Phase-II upgrade

ATLAS ITk and new pixel sensors technologies

LHCb Preshower(PS) and Scintillating Pad Detector (SPD): commissioning, calibration, and monitoring

ATLAS strip detector upgrade for the HL-LHC

CMS Note Mailing address: CMS CERN, CH-1211 GENEVA 23, Switzerland

arxiv: v1 [physics.ins-det] 9 Aug 2017

Surface resistivity measurements and related performance studies of the Bakelite RPC detectors

High counting rate, differential, strip read-out, multi gap timing RPC

The Compact Muon Solenoid Experiment. Conference Report. Mailing address: CMS CERN, CH-1211 GENEVA 23, Switzerland

CMS SLHC Tracker Upgrade: Selected Thoughts, Challenges and Strategies

Full characterization tests of Micromegas with elongated pillars

The CMS Muon Trigger

The Run-2 ATLAS Trigger System

CMS Note Mailing address: CMS CERN, CH-1211 GENEVA 23, Switzerland

The ATLAS detector at the LHC

Resistive Micromegas for sampling calorimetry

Muon Collider background rejection in ILCroot Si VXD and Tracker detectors

PoS(VERTEX2015)008. The LHCb VELO upgrade. Sophie Elizabeth Richards. University of Bristol

The LHCb trigger system: performance and outlook

Upgrade of the CMS Tracker for the High Luminosity LHC

Micromegas calorimetry R&D

Installation, Commissioning and Performance of the CMS Electromagnetic Calorimeter (ECAL) Electronics

THE ATLAS experiment was designed for a wide physics

High granularity scintillating fiber trackers based on Silicon Photomultiplier

Simulations Of Busy Probabilities In The ALPIDE Chip And The Upgraded ALICE ITS Detector

A High Granularity Timing Detector for the Phase II Upgrade of the ATLAS experiment

Characterization of the stgc Detector Using the Pulser System

arxiv: v1 [physics.ins-det] 9 May 2016

The LHCb Upgrade BEACH Simon Akar on behalf of the LHCb collaboration

Test Beam Measurements for the Upgrade of the CMS Phase I Pixel Detector

Operational Experience with the ATLAS Pixel Detector

The Commissioning of the ATLAS Pixel Detector

A Characterisation of the ATLAS ITk High Rapidity Modules in AllPix and EUTelescope

Muon reconstruction in ATLAS

Attilio Andreazza INFN and Università di Milano for the ATLAS Collaboration The ATLAS Pixel Detector Efficiency Resolution Detector properties

optimal hermeticity to reduce backgrounds in missing energy channels, especially to veto two-photon induced events.

ATLAS Phase-II Upgrade Pixel Data Transmission Development

1.1 The Muon Veto Detector (MUV)

A Cosmic Muon Tracking Algorithm for the CMS RPC based Technical Trigger

CONTROL AND READOUT ELECTRONICS OF THE TIME- OF-FLIGHT SYSTEM OF THE MPD

OPERA RPC: installation and underground test results

Mitigating high energy anomalous signals in the CMS barrel Electromagnetic Calorimeter

Development of High Granulated Straw Chambers of Large Sizes

PoS(EPS-HEP 2009)150. Silicon Detectors for the slhc - an Overview of Recent RD50 Results. Giulio Pellegrini 1. On behalf of CERN RD50 collaboration

arxiv: v1 [hep-ex] 12 Nov 2010

Commissioning Status and Results of ATLAS Level1 Endcap Muon Trigger System. Yasuyuki Okumura. Nagoya TWEPP 2008

CMS Tracker studies. Daniel Pitzl, DESY

GEM beam test for the BESIII experiment

PoS(Vertex 2007)034. Tracking in the trigger: from the CDF experience to CMS upgrade. Fabrizio Palla 1. Giuliano Parrini

The Run-2 ATLAS. ATLAS Trigger System: Design, Performance and Plans

Small-pad Resistive Micromegas for Operation at Very High Rates. M. Alviggi, M.T. Camerlingo, V. Canale, M. Della Pietra, C. Di Donato, C.

Layout and prototyping of the new ATLAS Inner Tracker for the High Luminosity LHC

Upgrade tracking with the UT Hits

Transcription:

The RPC-based proposal for the ATLAS forward muon trigger upgrade in view of super-lhc arxiv:1210.6728v1 [physics.ins-det] 25 Oct 2012 University of Michigan, Ann Arbor, MI, 48109 On behalf of the ATLAS Muon Collaboration E-mail: junjie@umich.edu The innermost station of the present ATLAS forward muon detector needs to be upgraded for the super-lhc. We present a proposal to replace it with a sandwiched detector composed of several layers of small-radius Monitored Drift Tube chambers (smdt) for precision tracking measurement and two stations of multi-gap Resistive Plate Chambers (mrpc) for triggering purpose. We describe the layout of the upgraded detector and the trigger strategy. Several modifications to the RPCs used in the ATLAS barrel region are needed to satisfy the super-lhc requirements. Various studies with the proposed mrpc timing resolution, spatial resolution and rate capability have been performed. XI workshop on Resistive Plate Chambers and Related Detectors - RCP2012, February 5-10, 2012 INFN Laboratori Nazionali di Frascati Italy Speaker. c Copyright owned by the author(s) under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike Licence. http://pos.sissa.it/

1. The ATLAS muon detector and muon trigger system The ATLAS detector [1] is a general-purpose particle detector and is specifically designed to maximize the potential to uncover signs of new physics at the LHC. A unique feature of the ATLAS detector is its large muon spectrometer which has a total coverage area of 5500 m 2 [2]. Due to its unprecedented size, the spectrometer can detect muons in the pseudorapidity range η < 2.7, and measure their momenta with a standalone transverse momentum (p T ) resolution of approximately 10% for 1 TeV muons. With its large acceptance and good momentum resolution, the ATLAS muon spectrometer has a great potential for discovery of new physics. A quarter view of the ATLAS muon detector is shown in the left plot of Fig. 1. The precise momentum measurement is performed by the Monitored Drift Tube Chambers (MDT). They cover the pseudorapidity range η < 2.7 except the forward region 2 < η < 2.7 of the innermost endcap layer covered by the Cathode-Strip Chambers (CSC). Two different technologies have been used for the trigger chambers: the Resistive Plate Chambers (RPC) in the barrel region η < 1.1 and the Thin Gap Chambers (TGC) in the endcap region 1.1 < η < 2.4. A system of three large air-core toroids (each consists of eight coils) generates the magnetic field for the spectrometer. The schematic layout of the ATLAS muon trigger detector is shown also on the left plot of Fig. 1. In the barrel, two layers (RPC1 and RPC2) sandwich the MDTs of the middle layer, while the third one (RPC3) is located close to the outer MDT layer. In the endcap, the three layers are in front (TGC1) and behind (TGC2 and TGC3) the second MDT wheel (called "Big Wheel (BW)"), while the fourth layer (TGC I) is located in front of the innermost tracking layer (called "Small Wheel (SW)"). The trigger information is generated by a system of fast coincidences between the three last layers along the trajectory of the muon. The deviation from straightness is the deviation of the slope of the track segment between two trigger chambers from the slope of a straight line between the interaction point and the hit in a reference layer. The right plot of Fig. 1 shows the L1 trigger efficiency as a function of muon p T in the endcap region for five different trigger thresholds (0 GeV, 6 GeV, 10 GeV, 15 GeV and 20 GeV). The plateau efficiencies for three low p T triggers are close to 95% due to the coverage of the TGC detector; the plateau efficiencies for two high p T triggers are close to 90% due to the requirement of hits also in TGC1. Figure 1: Left: layout of the ATLAS detector and the schematics of the muon trigger system [1]. RPC2 and TGC3 are the reference planes for barrel and endcap, respectively. Right: muon trigger efficency as a function of muon p T for five different trigger thresholds in the endcap region. 2

2. Problems with the current ATLAS muon triggers and future upgrade strategy The current muon trigger strategy in the endcap region is based on the muon hits from two (or three) TGC layers at the BW. It is also assumed that all muons originate from the center of the detector (a LHC beam width of 5 cm along the z axis is ignored). The basic trigger principle is shown in the left plot of Fig. 2, only a vector BC at the BW is measured. Random background tracks due to other charged particles bent by the toroids and other neutral particles such as photons and slow neutrons can easily fake this condition. Studies based on the data taken in 2010 and 2011 runs indicated the following problems: (1) for events triggered by L1_MU20 triggers, about 90% of them are triggered by TGC triggers and only 10% are triggered by RPC triggers; (2) more than 95% of muons triggered by the L1_MU20 endcap trigger have no matching MDT segments in the SW; (3) the momentum resolution for the TGC triggers is close to 30% for 20 GeV muons at L1 due to the worse spatial resolution of the TGC chambers (about a few centimeters). Due to these problems the trigger bandwidth is limited and the high p T muon trigger is less efficient at high luminosity. The problems with large fraction of fake muons and worse momentum resolution limit the trigger bandwidth and make it less efficient to trigger on high p T muons at high luminosity runs. The L1 trigger rate for an instantaneous luminosity of 3 10 34 cm 2 s 1 at the super-lhc condition is estimated to be about 60 khz for L1_MU20 endcap triggers. An upgrade project to replace the current SW tracking and trigger chambers with a new SW detector for the Phase-I upgrade has been agreed within the ATLAS collaboration. One major purpose of this upgrade is to improve the L1 muon p T resolution and remove fake muon tracks seen by the BW TGCs at high instantaneous luminosity. This upgraded detector will provide a new vector A (as shown in the right plot of Fig. 2), the difference between the two angles measured by the new SW detector (vector A) and the current BW TGCs (vector BC) is then used to determine the muon p T at L1. To achieve a p T resolution of 15% for 20 GeV muons, the angular resolution provided by the new SW detector needs to be 1 mrad. There are currently three proposals within the ATLAS muon community to replace the present SW detector with either a Micromegas detector, a sandwich detector with small radius MDTs (smdt) plus either multi-gap RPCs or TGCs with finer strips. The technology to use for the upgrade will be decided later. With an upgraded SW detector satisfying the above requirements, the L1 muon trigger rate is expected to be about 20 khz for L1_MU20 endcap triggers at an instantaneous luminosity of 3 10 34 cm 2 s 1. Figure 2: Left: muon trigger strategy for the present ATLAS muon detector in the endcap region; Right: muon trigger strategy with the upgraded SW detector. 3

3. RPC-based proposal for the ATLAS SW upgrade One proposal to upgrade the SW detector is to replace it with a sandwich of smdt for precision tracking and two stations of multi-gap RPCs (mrpc) for triggering [3]. The layout of the new SW detector is shown in the left plot of Fig. 3. The mrpc will be assembled together with a smdt of equal dimensions in a common mechanical support structure which guarantees the relative alignment of the RPC to the rest muon sub-detectors in the endcap region. One of the major reasons to use the mrpcs for the new SW detector is due to its excellent timing capability. Fast detectors are crucial to reject low energy uncorrelated background. GEANTbased Monte Carlo simulation studies indicate that after the subtraction of time-of-flight, more than 90% of the muons arrive within the first 2 ns, while other charged particles and neutral particles such as photons and neutrons have flatter arrival time distributions. For example, only about 7 10% of other charged particles, photons or neutrons arrive in the first 2 ns timing window. Both muons and other charged particles create correlated hits in the SW and BW detectors, while photons and neutrons create uncorrelated hits in the SW and BW detectors. At an uncorrelated hit rate as high as 14 khz/cm 2, a very short time (about 2 ns) coincidence between contiguous detectors is an extremely efficient method to eliminate uncorrelated hits. The basic principle of the trigger scheme we propose is to remove fake muon tracks as soon as possible and as much as possible, and then use optical fibers to send the track hits from the SW mrpc to the trigger logic at USA15 to combine with hits provided by the BW TGCs. The present ATLAS RPCs in the barrel region are based on a 2 mm gas gap between two resistive electrodes 2 mm thick, made of a melamine coated phenolic laminate. The gas gap is sandwiched between two read out panels with mutually orthogonal strips giving a point in the space for each avalanche generated inside the gas gap. In order to fulfill the requirements defined for the SW upgrade, a substantial improvement with respect to the RPCs presently operating in ATLAS is needed concerning the rate capability, time resolution, position resolution and detector ageing. The new detector should be able to stand a rate of 14 khz/cm 2 for the region closest to the beam pipe. The trigger decision provided by the new SW detector and BW TGCs should be available within a 25 ns LHC bunch crossing time. In order to reach the designed angular resolution of 1 mrad, the spatial position resolution of the new detector should be about 300 µm at L1. The total integrated charge should be around 3 C/cm 2 for a total integrated luminosity of 3000 fb 1. To increase the rate capability and reduce the ageing effect, two parameters have to be optimized: the gas gap width which determines the amount of delivered charge per avalanche and the sensitivity of front end electronics which determines the minimum charge that can be discriminated from the noise. To obtain the required spatial resolution, we propose to use narrow readout strips, with a typical pitch of about 2 mm, coupled to an electronics circuit that can select the centroid position within a resolution of 300 µm at L1. The time required for the offline charge centroid method (charge collection and centroid calculation) would be too long at L1. We propose to split a single 2 mm gas gap into two 1 mm gaps giving the advantages of a better time resolution, a lower delivered charge which increases the rate capability. We will refer to this type of RPC as mrpc. The electrode thickness is reduced to 1 mm to avoid large voltage drop on the electrode plates due to large current expected at high instantaneous luminosity. A typical 2 mm strip pitch is expected for the readout strips on the bending plane. The strips will be equipped 4

with both ends connected to a mean-timer electronics circuit. The hit position determined using time difference for the signals from the two ends will be localized along the strip with a typical uncertainty of a few cm giving a further reduction of uncorrelated background in the coincidence of two contiguous chambers. The probability for two or more muons crossing the same readout strip is estimated to be below 0.01%. To obtain the centroid of the hits, we can either explore the fact that strips with larger charge deposition will cross the thresholds earlier using the meantimer circuit or group 8 10 readout strips in super-strips connected to a maximum selector which identifies, in a typical time of 10 ns, the strip with the maximum charge deposition. The layout of a proposed smdt plus mrpc unit is shown in Fig. 3. Three layers of mrpc detectors are arranged on both sides of an smdt chamber. Short time coincidences among detector layers of the same triplet can strongly reduce the uncorrelated background. The trigger logic requires the 2 out of 3 coincidence inside the same triplet followed by the twofold coincidence of the two triplet signals to remove almost all uncorrelated hits and still retain high efficiency. To reduce correlated hits produced by other charged particles, the angle provided by the two mrpc stations is required to be consistent with the angle for muons originating from the center of the detector. The proposed trigger strategy has the following advantages: (1) obtains unambiguous identification of bunch crossing ID; (2) provides simple on-chamber pattern recognition; (3) sends small amount of information to combine with track segments from the BW TGCs; (4) performs the coincidence between the SW and BW in the counting room; and (5) provides significant safety margin. Figure 3: Left: layout of the proposed sandwiched smdt and mrpc detector; Right: layout of smdt + six layers of mrpc detector. 4. Studies with the RPC To examine the mean-timer technique we have employed the MDT electronics for readout of RPC signals from both ends of the signal lines. Although these electronics are not adequately fast for a final system evaluation, it is fast enough to assess off-line the algorithms proposed. Studies indicate that a timing resolution of 0.6 ns is obtained for a typical RPC strip. The features of the MDT front-end that limit its timing precision are the slow peaking times (15 ns), the channel to channel threshold variations, and the 0.78 ns measurement bin. We are performing further tests with faster electronics developed by the ALICE experiment and we expect a timing resolution of 15 100 ps that can give a position resolution of 1 2 cm along the strip. We are also investigating sensitive front end readout electronics that can select smaller signals due to smaller gaps [4]. 5

To study the RPC spatial resolution, we used a single-gap glass RPC chamber with a thickness of 0.6 0.8 mm for the glass plates and a thickness of 1.2 mm for the gas gap. The readout strips have a pitch size of 1.27 mm and were readout at both ends by the present ATLAS MDT front-end readout electronics. Studies were done with 180 GeV muon beam at the CERN H8. The RPC chamber was placed in front of twelve layers of smdts (with a radius of 1.5 cm). The difference between the hit position determined by the RPC chamber compared to the extrapolated position from the smdt chamber indicates the spatial resolution of the RPC chamber. A spatial resolution of 288 ± 7 µm was obtained using the offline charge centroid method and 374 ± 11 µm using the timing information from the mean-timer circuit. More than 100 µm systematic uncertainty was expected from the smdt spatial resolution and relative alignment between these two detectors. The rate capability studies were performed using a mrpc with two gas gaps (2 mm bakelite plates and 1 mm gas gap) that is placed close to a Cs 137 source at the CERN GIF. The cosmic muon detection efficiency as a function of the high voltage applied is shown in Fig. 4 with and without the radiative source nearby. Similar detection efficiency was achieved at 12.5 kv even though there was a shift of a few hundred voltage for these two situations. The rate capability test was performed at a rate of 7 khz/cm 2 and is limited by the available source flux at GIF. Figure 4: Left: spatial resolution using the charge-centroild method; Right: mrpc detection efficiency as a function of the applied high voltage with and without the radiative source. 5. Conclusion We propose to upgrade the ATLAS SW muon detector with a sandwiched detector composed of smdt for precision tracking and two stations of mrpc for triggering. We made several modifications to the present ATLAS RPCs used in the barrel region and have perforned studies with the timing resolution, position resolution and rate capability. References [1] ATLAS Collaboration, JINST 3, S08003 (2008). [2] S. Palestini, Nucl. Phys. 125, 337 (2003). [3] T. Kawamoto, "ATLAS: status, limitations and upgrade plans", plenary talk at TIPP 2011 conference. [4] R. Cardarelli, "A high rate fast precision tracking trigger with RPCs", plenary talk at RPC 2012 conference. 6