Add-on modules DX 3 63A for MCBs DX 3 1,5 modules per pole

Similar documents
Btdin RCD Add-on modules 63A for MCBs 1,5 modules per pole

Btdin RCD Add-on Modules 32A - 63A for M.C.Bs 1 module per pole

(1,5 modules per pole)

Btdin RCD Add-on Modules 32A - 63A for M.C.Bs 1 module per pole

Single phase meter with direct connection and pulse or Modbus RS485 output

3-phase meter with direct connection and pulse or Modbus RS485 output

Technical features table for miniature circuit-breakers SH 200 Series

27/04/2015

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents

Multifuncion Measuring Device, 4 mod. DIN, connection via CT, with RS485 port

Multifuncion Measuring Device, 4 mod. DIN, connection via CT, with RS485 port

Type CP-S, CP-C & CP-A Switch mode

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet

Current monitoring relays CM-SRS.2 For single-phase AC/DC currents

CP-T range Product group picture

DRIVIA cabinets LIMOGES Cedex France 1. DESCRIPTION, USE 3. DIMENSIONS 2. RANGE, CAT. NO. EQUIVALENCE TABLE

CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. UL 508, CAN/CSA C22.2 No.14 GL GOST CB scheme CCC

Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages

ABB 1. Multifunctional three-phase monitoring relays. CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. Features. Approvals. Marks.

Three-phase monitoring relays

Voltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Current monitoring relays CM-SRS.1 For single-phase AC/DC currents


Electronic timer CT-TGD.22

ABB NEW. Three-phase monitoring relays. CM-PVS.31 and CM-PVS.41 Data sheet. Features J. Approvals. Marks. Order data. Order data - Accessories

Current monitoring relays CM-SRS.1 for single-phase AC/DC currents

CP-T range Benefits and advantages

Three-phase monitoring relay CM-PFS

Electronic timer CT-MFS.21


Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

Electronic timer CT-SDS.22

Electronic timer CT-SDD.22

Page 13-2 Page Page 13-7

Type Nominal voltage (V) Code HSV V

VEO. V2PF480Y/277VS01 Art.Nr.: B TECHNICAL DATA

V2IM10AL10 Art.Nr.: V2IM10AL10P Art.Nr.: Control element. Tripping delay. Function selector. Status indication 24...

ABB NEW. Multifunctional three-phase monitoring relays. CM-MPS.23 and CM-MPS.43 Data sheet. Features J. Approvals. Marks.

RE17RCMU off-delay timing relay - 1 s..100 h V AC - 1 OC

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

CP-E range Benefits and advantages

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

05/09/2012

Three-phase monitoring relays CM-PVS CM-PVS.31, CM-PVS.41 and CM-PVS.81

V2UM230V10 Art.Nr.: V2UM230V10P Art.Nr.: Control elements. Tripping delay. Function selector. Status indication 230 V AC/DC

Current monitoring relays CM-SRS.M1 For single-phase AC/DC currents

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC

Multifunctional three-phase monitoring relays CM-MPS CM-MPS.23

Zelio Control Measurement Relays

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41

Three-phase monitoring relays CM-PVS.81

Electronic timer CT-MVS.12 Multifunctional with 1 c/o (SPDT) contact

Three-phase monitoring relays CM-PFE and CM-PFE.2

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

48 Series - Relay interface modules A. Features

s s s 3-60 s min min 3-60 min h h 3-60 h V AC, 50/60 Hz

ABB 1. Multifunctional three-phase monitoring relays. CM-MPN.52, CM-MPN.62 and CM-MPN.72 Data sheet. Features. Approvals. Marks.

Modular equipment. Presentation, standards. Standard contactors TeSys GC

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

Industrial, 2-Pole ZS Type RA2A

Three-phase monitoring relay CM-PVE

Power supply CP-T 24/20.0 Primary switch mode power supply

Power supply CP-E 24/2.5

Electronic timer CT-MXS.22 Multifunctional with 2 c/o (SPDT) contacts

Power supply CP-D 24/4.2 Primary switch mode power supply

Multifunctional three-phase monitoring relays CM-MPS CM-MPS.23 and CM-MPS.43

Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact

Characteristics 5 TeSys k contactors and reversing contactors

Electronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts

Power supply CP-T 24/10.0 Primary switch mode power supply

Power supply CP-T 24/40.0 Primary switch mode power supply

Electronic timer CT-WBS.22 Impulse generating and flashing with 2 c/o (SPDT) contacts

Motor-protective circuit-breaker, 3p, Ir=40-50A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A

NEW CIRCUIT PROTECTIONRANGE

Power supply CP-E 24/20.0

LC1D12BL TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V DC coil

LC1D32BD TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A - 24 V DC coil

LC1D25BL TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A - 24 V DC coil

TeSys contactors. TeSys D contactors. IEC/EN , IEC/EN , UL 508, CSA C22.2 n 14. Protection against direct fi nger contact IP 2X

isw switches Control Local control IEC/EN , isw switch with indicator light. IEC/EN , isw switch without indicator light.

Thermistor motor protection relays

Three-phase monitoring relay CM-PBE

RE22R2MMU Multifunction Timer Relay - 24VDC/ V AC - 2 C/O

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

02/11/2015

LC2D09BL REVERSING CONTACTOR 575VAC 9A IEC

Power supply CP-T 48/20.0 Primary switch mode power supply

Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC

Electronic timer CT-MFS.21 Multifunctional with 2 c/o (SPDT) contacts

Electronic timer CT-MFS.21 Multifunctional with 2 c/o (SPDT) contacts

Power supply CP-D 24/1.3

Power supply CP-T 48/5.0 Primary switch mode power supply

Three-phase monitoring relay

RE17RMMU time delay relay 10 functions - 1 s..100 h V AC - 1 OC

Electronic timer CT-MBS.22 Multifunctional with 2 c/o (SPDT) contacts

Transcription:

87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 Add-on modules DX 3 63A for MCBs CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection... 2 5. General characteristics... 3 6. Compliance and approvals... 4 7. Curves... 4 8. Auxiliaries and accessories... 5 1. DESCRIPTION - USE Add-on module, for MCB. DX 3 63A, 1,5 modules per pole width, breaking capacity, 25kA, 36kA or 50kA. Assure the protection of people against direct and indirect electric shocks and protection of installations against insulation faults. Symbol: 2. RANGE (continued) Rated Voltage / Frequency:. 230 / 400 V ~, 50 Hz standard tolerances.. 240 / 415 V ~, 50 Hz standard tolerances. Maximum operating voltage:. 440 V ~, 50 Hz with standard tolerances. Minimum operating voltage:. 185 V ~, 50 Hz. 3. OVERALL DIMENSIONS Technology:. Electromagnetic residual current operating by sensitive relay 2. RANGE Polarities :. 2 poles, 3 poles et 4 poles. Width:. Fixed threshold version Double pole 2 modules (2 x 17,8 mm = 35,6 mm). Triple / Four pole 3 modules (3 x 17,8 mm = 53,4 mm).. Adjustable threshold version Double pole 4 modules (4 x 17,8 mm = 71,2 mm). Triple / Four pole 6 modules (6 x 17,8 mm = 106,8 mm). Rated current:. 63 A. Sensitivities and tripping time:. 30 ma instantaneous.. 300 ma instantaneous.. Adjustable sensitivity from 300 ma to 1000 ma with instantaneous or delayed tripping of 60 ms or 150 ms. Type:. A-Hpi: sinusoidal AC fault currents with or without DC component and immunity against unwanted tripping (Hpi type are also A types). N of poles X Y Fixed version Y Adjustable version 2P 53,4 mm 35,6 mm 71,2 mm 3P 80,1 mm 53,4 mm 106,8 mm 4P 106,8 mm 53,4 mm 106,8 mm Technical data sheet: F01221EN/01 Updated on: 12/09/2013 Created on: 19/12/2011 1 / 5

4. PREPARATION - CONNECTION. On the right side of the MCB DX 3 63 A. Joins to the circuit breaker by plastic clamps and tightening of connections in the downstream terminals of the MCB. Mounting :. On symmetrical EN 60.715 rail or DIN 35 rail Power Supply:. From the top trough the associated MCB or from the bottom directly on the add-on module. 4. PREPARATION CONNECTION (continued) Labelling:. Circuit identification by way of a label inserted in the label holder of the associated MCB, situated on the front of the product. 5. GENERAL CHARACTERISTICS Marking on the front side:. By permanent ink pad printing Fixed threshold version Operating positions:.vertical Horizontal Upside down On the side Screw terminals:. Terminals protected against accidental contacts (IP20).. Cage terminals, detachable and captive screw. Terminals depth: 14 mm.. Stripping length : 14 mm. Screw head: Pozidriv n 2.. Recommended tightening torque: 3 Nm.. The screw terminals are separated by built-in shields. Adjustable threshold version Connectable section:. In the power terminals in the lower part of the product.. Copper cable. Without ferrule With ferrule Rigid cable 1 x 50 mm² - Flexible cable 1 x 35 mm² 1 x 35 mm². Recommended tools:. For the terminals: Pozidriv n 2 screwdriver or flat screwdriver 5,5 mm (6,5 mm maxi).. For fixing on the DIN rail: flat screwdriver 5.5 mm (from 4 to 6 mm). Manual actuation of the Add-on module:. By the 2-positions ergonomic handle of the associated MCB - I / ON : Closed circuit. - O / OFF : Open circuit. Contact status display:. By marking of the associated MCB handle: O-Off white on a green background = contacts opened. I-On white on a red background = contacts closed. Display of differential-fault:. Yellow mechanical signaller into the window on front-side marking zone. Test key operating voltages: U min 170 V ~ U max 440 V ~ This voltage range gives the possibility to use double-pole differential blocks in 230 V or 400 V, and triple / four pole differential blocks in three phase network with or without neutral 230 V and 400 V. For the wiring of a four-pole differential block in a three phase network without neutral, make sure to properly wired three consecutive poles to supply the test key. 2 / 5

Neutral system:. IT TT TN. Residual breaking capacity IΔm:. In accordance with standard EN 61009-1 9.12.11.4d (I m: shortcircuit to ground) I m = 60% of Icu of the associated MCB. Insulation rated voltage:. Ui = 500 V according to IEC/EN 61009-1 Pollution degree:. 3. Dielectric strength:. 2500 V. Pulse rated voltage:. Uimp = 6 kv (wave 1.5 / 50 s). Operation at 400Hz:. The value of the threshold varies with frequency.. See curve on page 5. Protection against unwanted tripping:. Hpi type, fixed add-on module held to the wave 8 / 20 µs : 3000 A. damped recurrent wave 0,5 µs / 100 khz : 200 A.. Hpi type, adjustable add-on module held to the wave 8 / 20 µs : 5000 A. damped recurrent wave 0,5 µs / 100 khz : 200 A. Protection class:. Protection index of terminals against solid and liquid bodies (wired device): IP 20 (in accordance with standards IEC 529, EN 60529 and NF C 20-010).. Protection index of the box against solid and liquid bodies: IP 40 (in accordance with standards IEC 529, EN 60529 and NF C 20-010).. Class II compared to conductive parts.. Protection index against mechanical shocks: IK 02 (in accordance with standards EN 50102 and NF C 20-015). Mechanical and electrical endurance (associated to MCB):. 20000 operations without load.. 10000 operations with load.. 750 differential tripping operations by the Test key.. 750 differential tripping operations for fault current. Power dissipated and impedance per device at In: Double pole Triple / Four pole In Z (mω) P (W) Z (mω) P (W) 6 A 1,11 0,04 1,94 0,07 10 A 1,00 0,1 1,90 0,19 16 A 1,02 0,26 1,95 0,5 20 A 1,03 0,41 1,95 0,78 25 A 1,02 0,64 1,92 1,2 32 A 1,04 1,06 1,95 2 40 A 0,43 0,68 0,55 0,88 50 A 0,43 1,07 0,55 1,37 63 A 0,43 1,7 0,55 2,17 Please note that to get the total power dissipated by the Add-on module these powers are to be added to those of the associated MCB Enclosure material:. Parts of polyester.. Characteristics of this material: self extinguishing, heat and fire resistant in accordance with standard EN 60898-1, glow-wire test at 960 C for external parts made of insulating material necessary to retain in position current-carrying parts and parts of protective circuit (650 C for all other external parts made of insulating material). Volume and quantity when packed:. Double pole 2,4 dm 3 per device.. Triple / Four pole 3,7 dm 3 per device. Average weight per device:. Double pole 0,39 kg.. Triple pole 0,42 kg.. Four pole 0,52 kg. Ambient operating temperature:. Min. = -25 C. Max. = +70 C Derating according ambient temperature:. Reference temperature: 40 C in accordance with standards IEC/EN 60947-2.. No derating of the differential block depending on the ambient temperature between - 25 C and +40 C.. Derating between + 40 C and + 70 C : Temperature 40 C 50 C 60 C 70 C % of In 100 % 95 % 90 % 85 % Ambient storage temperature:. Min. = -40 C. Max. = +70 C 3 / 5

Resistance to sinusoidal vibrations:. In accordance with standard IEC 60068-2-6.. Axis : x, y, z.. Frequency range: 5 100 Hz ; duration 90 minutes. Displacement (5 13,2 Hz) : 1mm. Acceleration (13,2 100 Hz) : 0,7g (g=9,81 m/s 2 ). 7. CHARACTERISTC CURVES Residual current operating characteristic. Average tripping time depending on the intensity of the fault current.. Sensitivities 30 ma, 300 ma, 500mA et 1000 ma instantaneous (Hpi type) Influence of the altitude : 2000 m 3000 m 4000 m 5000 m Dielectric strength Max operating voltage Derating at 30 C 3000 V 2500 V 2000 V 1500 V 400 V 400 V 400 V 400 V none none none none 6. COMPLIANCE AND APPROVALS In accordance with standards:. NF / EN / IEC 61009-1.. EN / IEC 60947-2. Environment respect Compliance with CEE directives:. Compliance with Directive 2002/95/EC of 27.1.2003 called "RoHS" provides the banishment of hazardous substances such as lead, mercury, cadmium, hexavalent chromium, brominated flame retardants polybrominated biphenyls (PBB) and polybrominated diphenylethers (PBDE) from 1 July 2006. Compliance with Directives 91/338/CEE of 18/06/91 and decree 94-647 of 27/07/04.. Compliance with Directives 73/23/CEE and 93/68/CEE (DBT).. Compliance with Directives 83/336/CEE, 92/31/CEE and 93/68/CEE (CEM).. Sensitivities 30 ma, 300 ma, 500mA et 1000 ma Hpi type with a time delay of 60 ms (selective). Plastic materials :. Halogen-free plastic materials.. Marking of parts according to ISO 11469 and ISO 1043. Packaging:. Design and manufacture of packaging in accordance with decree 98-638 of 20.07.1998 and Directive 94/62/EC. 4 / 5

7. CHARACTERISTC CURVES (continued) Residual current operating characteristic. Sensitivities 30 ma, 300 ma, 500mA et 1000 ma Hpi type with a time delay of 150 ms. 8. AUXILIARIES AND ACCESSORIES Installation software:. XL PRO 3. Curves of variation of tripping threshold according to the frequency. Sensitivities 30 ma, 300 ma, 500mA and 1000mA type Hpi. 5 / 5