Current Module, 3-channel, MDRC SM/S , GH Q R0111

Similar documents
The universal input/output device is a DIN rail mounted device. It is connected to the EIB via a bus connecting terminal.

Time Switch, 2-channel, MDRC SW/S 2.5, GH Q R0001

For controlling 4 independent shutter or sunblind drives via ABB i-bus including the functions Up/Down, Step/Stop.

Shutter Actuator with Manual Operation, 4-fold, 230 V AC, MDRC JA/S M, GH Q R0111. ABB i-bus EIB / KNX

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

1. Function. Universal dimming actuator REG-K/2x230/ 300 W. Universal dimming actuator REG-K/230/ 500 W. Universal dimming actuator REG-K/230/ 1000 W

KNX manual 1-channel flush-mounted switch actuator SU 1

Room thermostat solo, FM Type: 6124-xx

EIB/KNX Switch Actuators. User manual

PHOENIX CONTACT - 09/2009

K-BUS Switch Actuator

Radio bus system Radio-universal dimming actuator, 1-gang. 1 Safety instructions. 2 Device components. Order-No. : Operating instructions

EMD-FL-C-10. Current Monitoring Relay. Data Sheet. Functions. Structure 08/2004

PHOENIX CONTACT

gesis EIB V Manual Installation system for European Installation Bus Products and Objects description

LED Driver Constant voltage

1 Safety instructions. 2 Device components. 3 Function. KNX Heating actuator 6gang RMD 230 V. Order-No. :

FIB / FIC. r with Overcurrent Protection (RCBO) Doepke. » effi cient. » reliable. » fl exible. » future-oriented

series dimmer actuators, DMG 2 S, Upgrade Module DME 2 S and Booster DMB 2

ABB i-bus KNX Energy Actuator SE/S Product Manual

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC

ABB i-bus. KNX Weather Station WS/S Product Manual

LED Driver Constant voltage

Electronic Circuit Breaker ECONOMY REMOTE

ABB i-bus KNX Meter Interface Module, MDRC ZS/S 1.1. Product Manual. Intelligent Installations Systems ABB

For Immediate Delivery call KMParts.com at (866)

The room thermostat application module with 2-fold switch sensor is placed on a flush-mounted bus coupler.

ABB i-bus KNX Energy Actuator SE/S Product Manual

USER MANUAL CU-DIN DIM 4-CH 1.5A KNX EC MA

LED Driver Linear / area fixed output

Protection and safety SQZ3 phase and sequence relay

2 or 4 pole changeover contact Plug-in/Faston 187

LED Driver Compact dimming

PHASED OUT. LED Driver Compact dimming. Driver LCAI 55W 900mA 1750mA ECO C ECO series

PHASED OUT. LED Driver Compact dimming. Driver LCAI 20W 350mA 900mA ECO SR ECO series

QUINT-PS/ 3AC/24DC/10

Electronic Circuit Breaker ECONOMY SMART. - Number of available output channels: 2 / 4 / 8

Series Dimmer Actuator DMG 2, Upgrade Module DME 2 and Booster DMB 2 DMG DME DMB

PHOENIX CONTACT

LED Driver Compact fixed output. Udriver LC 25/30/35/40W 600/700/800/900mA fixc SC ADV ADVANCED series

KNX Powerline PL 110. KNX Association

LED Driver Compact fixed output

Instruction manual. art Installation manual

LED Driver Linear / area dimming

Motor-protective circuit-breaker, 3p, Ir=40-50A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A

LED Driver Compact fixed output 4,5 83,5 93. Ordering data. Type

RAIL MOUNTED NETWORK METER TYPE N27D USER S MANUAL

QUINT-PS/ 3AC/24DC/40

PHASED OUT. LED Driver Compact dimming. Driver LCAI 55W 900mA 1750mA ECO SR ECO series

27/04/2015

LED Driver Compact dimming

PHASED OUT. LED Driver Linear / area dimming. Driver LCAI 20W 350mA 550mA ECO lp ECO series

PHASED OUT. LED Driver Linear / area dimming. Driver LCAI 100W 350mA 900mA ECO INDUSTRY sl ECO series

LED Driver Linear / area dimming. Udriver LCAI 20W 350mA 550mA ECO lp ECO series

PHASED OUT. LED Driver Linear / area dimming. Driver LCAI 20W 150mA 400mA ECO lp ECO series

LED Driver Compact dimming

ABB i-bus KNX Valve Drive Actuator VAA/S x Product Manual

LED Driver Compact fixed output. Udriver LC 15/20/25W 350/500/700/600mA fixc C SNC ESSENCE series

QUINT-PS AC/24DC/40

LED Driver Compact fixed output

LED Driver Constant voltage

Current monitoring relays CM-SRS.1 For single-phase AC/DC currents

LED Driver Compact fixed output

Switching power supplies CP range, Linear power supplies CP-L range. Content

PRODUCT MANUAL. ABB i-bus KNX VC/S 4.x.1 Valve Drive Controller

Electronic Circuit Breaker BASIC SMART. - Number of available output channels: 2 / 4 / 8

KNX manual High-performance switch actuators RM 4 H FIX1 RM 8 H FIX2

EMD-FL-3V-400. Electronic monitoring relay for voltage monitoring in three-phase networks. INTERFACE Data sheet _en_03. 1 Description.

LED Driver Constant voltage

LED Driver Compact fixed output

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

QUINT-PS/ 1AC/24DC/20

LED Driver Linear / area dimming

LED Driver Constant voltage

Electronic Circuit Breaker with reset input ESS20-1..

CU-DIN DIM 6-CH 0 10V KNX

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Residual Current-operated Circuit Breakers (RCCBs) F 360 and F 370 Range

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

LED Driver Compact fixed output

TSX Series. Modicon Manuals. Presented by: Modicon PLC. Schneider Electric Quantum Modicon Gould Gettys

VariTrans P D1 TRMS

21 VA (l max 20 5 ms) Connection Cable 1 m, 4 x 0.75 mm 2 Functional data Factory settings Variable Setting Torque Inhibiting torque

LED converter Linear / area dimming. Uconverter LCAI 80 W 350 ma one4all V ECO

LED Driver Constant voltage. Udriver LCA 100W 24V one4all SC PRE PREMIUM series

PHASED OUT. LED Driver Compact fixed output. Driver LCI 10W 150mA 400mA TOP C TOP series. Product description


AC/DC. Monitoring Technique. VARIMETER IMD Insulation monitor RN 5897/300

(1,5 modules per pole)

Electronic relays. Monitoring. Monitoring

LED Driver Linear / area fixed output

LED Driver Compact dimming

LED Driver Constant voltage

Installer manual inputs/outputs interface for led KNX

Current monitoring relays CM-SRS.1 for single-phase AC/DC currents

1 Safety instructions. 2 Device components. Radio bus system. Radio socket outlet adapter for dimming Order No. : Operating instructions

Power IT LV Active Filters PQFI PQFM PQFK. The ABB comprehensive solution for active filtering of harmonics

ABB i-bus KNX DALI Light Controller DLR/S M Product Manual

MINI-PS AC/24DC/1.3

LED Driver Linear / area dimming

Transcription:

, GH Q631 0034 R0111 SK 0086 B 99 Load and residual currents can be measured simultaneously using the current module. There are 3 isolated and independent measuring circuits available for this. The current measured values can be continually sent in the form of EIB telegrams and displayed for example on an LCD screen. The nominal operating current per channel is max. 16 A for load currents and max. 30 A for residual currents. The device can measure temporary overcurrents up to 25 A (< 1 h, max. one measuring circuit per device). The current module can be used e.g. for the following applications: display of operating states, display of mesured values, trend analysis for early detection of faults, logging of load/time evaluations and recording of operating hours. Technical data Power supply EIB 24 V DC, via the bus line Measuring accuracy +/-2% of upper measurement value (sinus) Measuring circuits Number 3 isolated measuring circuits Nominal voltage max. 230/400 V AC Frequency 50 Hz (+/- 10%) Back-up fuse 16 A Measurement of load current Nominal current 16 A AC per measuring circuit (upper measurement value: 25.5 A, resolution: 0.1A) Measurement of residual current Nominal residual current 30 ma AC per measuring circuit (upper measurement value: 51.0 ma, resolution: 0.2 ma) Type of residual current Type A - sinusoidal a.c. and oscillating d.c. Operating and display elements Red LED and push button for entering the physical address Connections Per measuring circuit 4 screw terminals, bus connecting terminal (supplied) Wire range 0.5 2.5 mm 2 finely-stranded 0.5 4.0 mm 2 single core EIB Bus terminal 13 Type of protection IP 20 in accordance with EN 60 529 13 Ambient temperature range Operation - 5 C 45 C Storage - 25 C 55 C Transport - 25 C 70 C Design Modular installation device, prom Housing, colour Plastic housing, grey Mounting on 35 mm mounting rail, EN 50022 Dimensions 90 x 72 x 64 mm (H x W x D) Mounting depth/width Weight Certification CE norm 68 mm / 4 modules at 18 mm 0.23 kg EIB-certified in accordance with the EMC guideline and the low voltage guideline Page 1 of 6

, GH Q631 0034 R0111 Application programs Number of Max. number of Max. number of communication objects group addresses associations Current Value Threshold /1 12 12 12 Circuit diagram SK 0033 Z 99 Note 1 Back-up fuse 5 Connection for measurement of 2 Programming push button/led load current only 3 Marker tag 6 Connection for measurement of 4 Inputs and outputs load and/or residual current 7 Bus connecting terminal The current module is used solely for measuring load and/or residual currents. shock due to feedback from various external conductors, an all-pole disconnection must be complied with. It is not permitted to use the current module in connection with an EIB switch actuator in place of primary protective devices such as miniature circuit-breakers or residual-current operated circuit-breakers. In order to avoid the danger of electric Continuous currents outside the measurement range of the nominal load current i.e. > 16 A, can lead to the current module being damaged. Page 2 of 6

, GH Q631 0034 R0111 Current Value Threshold /1 Selection in ETS2 ABB Security Current measurement module Measuring range The following table indicates the measuring ranges and their respective byte value that are sent to the EIB: Byte value Load current Residual current Zero measured current 0 0 0 Upper measurement value 255 25.5 A 51.0 ma (theoretical) Resolution 1 bit 0.10 A 0.20 ma Tolerance (±) (sinus) 5 bits 0.51A (2%) 1.02mA (2%) Upper measurement value 242 24.2 A 48.4 ma (physical) Current Value Various loads can be connected to the current module e.g. pure resistive loads (incandescent lamps or heating elements), mixed loads (incandescent lamps and PCs) or non-linear loads (dimmers or devices with electronic ballast). The current module measures the average value of the current. As a longer period is required for non-linear loads to determine the average value, there is a parameter available Accuracy of RMS measurement value. The more loads of this type in the circuit, the higher this parameter should be set. If load or residual currents for resistive loads e.g. incandescent lamps are to be specified with the current module, the parameter Accuracy of RMS measurement value can be set to normal. If load or residual currents for non-resi- 13 stive loads are to be measured, the pa- 13 rameter must be set to increased or high. The measured load or residual current value is sent as a 1 byte telegram to the EIB. In order to reduce the level of telegram traffic e.g. in installations where the current fluctuates too frequently from the average value (low frequency ripple voltage), the measured value is only sent if there is a definite minimum change from the last sent value. It is possible to parameterise the size of the change. If the setting +/- 0.0 A is selected for load current measurement and +/- 0.0 ma is selected for residual current measurement, the measured value is sent after each new measurement cycle. If the setting that is selected for the size of the change is too large, the present current value can differ considerably from the last sent value. In the table above, the relationship between the measured current and the sent 1 byte value is represented. If the actual current value lies outside the physical measuring range i.e. > 24.2 A or > 48.4 ma, the value 255 is sent as an overload signal. Page 3 of 6

, GH Q631 0034 R0111 Threshold 1 bit switching telegrams can also be sent when measuring load or residual currents. If the upper threshold is exceeded, a 1 is sent on the EIB while a 0 is sent when the measured value falls below the lower threshold. The threshold values can be parameterised. They can take the form of a hysteresis i.e. the upper and lower thresholds have different values. If the upper and lower thresholds are not identical, the gap between the threshold values must be passed through in order to trigger a telegram. The triggering of the threshold can be used for example to indicate the operating states of electrical loads. The state is then recorded directly via the load current. If there is an overshoot in the threshold for residual current, it is possible to trigger an alarm. Page 4 of 6

, GH Q631 0034 R0111 Communication objects for activated load current circuits No. Type Object name Function 0 1 byte Load current Circuit A Telegr. Value 1 1 byte Load current Circuit B Telegr. Value 2 1 byte Load current Circuit C Telegr. Value 6 1 bit Load current Circuit A Telegr. Switch 7 1 bit Load current Circuit B Telegr. Switch 8 1 bit Load current Circuit C Telegr. Switch Communication objects for activated residual current circuits No. Type Object name Function 3 1 byte Residual current Circuit A Telegr. Value 4 1 byte Residual current Circuit B Telegr. Value 5 1 byte Residual current Circuit C Telegr. Value 9 1 bit Residual current Circuit A Telegr. Switch 10 1 bit Residual current Circuit B Telegr. Switch 11 1 bit Residual current Circuit C Telegr. Switch Communication objects for activated load and residual current circuits No. Type Object name Function 0 1 byte Load current Circuit A Telegr. Value 1 1 byte Load current Circuit B Telegr. Value 2 1 byte Load current Circuit C Telegr. Value 3 1 byte Residual current Circuit A Telegr. Value 4 1 byte Residual current Circuit B Telegr. Value 5 1 byte Residual current Circuit C Telegr. Value 6 1 bit Load current Circuit A Telegr. Switch 7 1 bit Load current Circuit B Telegr. Switch 8 1 bit Load current Circuit C Telegr. Switch 9 1 bit Residual current Circuit A Telegr. Switch 10 1 bit Residual current Circuit B Telegr. Switch 11 1 bit Residual current Circuit C Telegr. Switch Page 5 of 6

, GH Q631 0034 R0111 Parameters The default setting for the values is printed in bold type. Common for all measuring circuits: Accuracy of RMS measurement value normal increased high if normal is selected: Suitable for ohmic loads e.g. incandescent lamps Duration of a measurement cycle = 3.3 s * number of activated measurement circuits if increased is selected: Suitable for mixed loads e.g. lighting circuits, PCs Duration of a measurement cycle = 6.6 s * number of activated measurement circuits if high is selected: Suitable for non-linear loads e.g. dimmers, electr. ballasts Duration of a measurement cycle = 10 s * number of activated measurement circuits Separate for each load current circuit: Function none activated only if function is activated: Send measured value on change of +/- 0.0 A / +/-0.1 A /... / +/-25.5 A more than Hysteresis for the transmission of switching telegrams Upper threshold value 0.0 A / 0.1 A /... / 25.5 A Lower threshold value 0.0 A / 0.1 A /... / 25.5 A Separate for each residual current circuit: Function none activated only if function is activated: Send measured value on change of +/- 0.0 ma / +/- 0.2 ma /... / +/-51.0 ma more than Hysteresis for the transmission of switching telegrams Upper threshold value 0.0 ma / 0.2 ma /... / 51.0 ma Lower threshold value 0.0 ma / 0.2 ma /... / 51.0 ma Page 6 of 6