CHAPTER 10 HIGH VOLTAGE TESTING OF ELECTRICAL APPARATUS

Similar documents
EE 1402 HIGH VOLTAGE ENGINEERING

ROEVER ENGINEERING COLLEGE ELAMBALUR, PERAMBALUR DEPARTMENT OF ELECTRICAL & ELECTRONICS ENGINEERING

High-Voltage Test and

DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING QUESTION BANK SUBJECT CODE & NAME : EE 1402 HIGH VOLTAGE ENGINEERING UNIT I

EE High Voltage Engineering UNIT IV - MEASUREMENT OF HIGH VOLTAGES AND HIGH CURRENTS PART-A 1. Mention the techniques used in impulse current

HIGH VOLTAGE TESTING GENERATION AND MEASUREMENTS

Condition Assessment of High Voltage Insulation in Power System Equipment. R.E. James and Q. Su. The Institution of Engineering and Technology

List of Experiments. Exp. # Experiment Title Page #

Analysis of Major Changes to Arrester Standards IEC STEVE BREWER

Prepared by Mick Maytum

Device Under Test: ALTEA VS- 24-I VS-24-I. 0 24/09/12 First issue A. Peretto L. Peretto 1 24/06/16 All text review E. Scala L. Peretto J. L.

CHAPTER 2. v-t CHARACTERISTICS FOR STANDARD IMPULSE VOLTAGES

Comparison of CAN/CSA C88.1, IEEE C /01 & IEC 60137

INTERNATIONAL STANDARD

NXCT 345 kv Test Performance Record For LAPEM

Power Engineering II. High Voltage Testing

PANIMALAR ENGINEERING COLLEGE Department of Electrical and Electronics Engineering

IEC Type Test Report Report No. EU1517-H-00.1 H4 Series Porcelain-housed Arrester 20,000 A Line Discharge Class 4

A Review Comprehension: Guideline for Testing of HV, EHV and UHV Substation Equipment

Low voltage products in high altitudes

10. DISTURBANCE VOLTAGE WITHSTAND CAPABILITY

MV Power Cable Diagnostics by Frequency Domain Spectroscopy. Peter Werelius Programma Electric AB

HVDC Transmission. Michael Muhr. Institute of High Voltage Engineering and System Performance Graz University of Technology Austria P A S S I O N

Earthing of Electrical Devices and Safety

Appendix B to Working on Exposed Energized Parts

(participation = half letter grade, 5%)

ALLOWABLE LIMITS TO SHORT TIME VOLTAGE DROPS IN HV WITHSTAND TESTS

Insulation Coordination Fundamentals Where Arrester and Insulator Characteristics Meet

SPECIFICATION No SS-135/ kv METAL OXIDE SURGE ARRESTERS WITHOUT GAPS

CIGRE WG A3.06 Reliability of High Voltage Equipment Intermediate Results CIGRE WG A3.06. Reliability of High Voltage Equipment

High voltage engineering

H V T E S T S O L U T I O N S PA RT N E RS F O R H V & E M C

POWER TRANSFORMER SPECIFICATION, DESIGN, QUALITY CONTROL AND TESTING 18 MARCH 2009

DEVELOPMENT OF A TEST PROTOCOL FOR A 15 KV CLASS SOLID-STATE CURRENT LIMITER

36kV VOLTAGE TRANSFORMERS (OUTDOOR TYPE)

Chapter 1. Overvoltage Surges and their Effects

700 Series AC Dielectric Test Sets

IMPORTANCE OF ACCURATE MEASUREMENTS DURING THE LIFE CYCLE OF UTILITIES

VI 3 - i TABLE OF CONTENTS

Australian Standard. Instrument transformers. Part 1: Current transformers (IEC Ed.1.2 (2003) MOD) AS AS

High Frequency Voltage Stress. Presented by: Flore Chiang Date: March 30, 2012

KNOW MORE ABOUT THE TRANSFORMERS. Glossary Transformers

Connector Operating Voltage

OVER VOLTAGES IN ELECTRICAL POWER SYSTEMS

APPLICATION OF LONG FLASHOVER ARRESTERS FOR IMPROVEMENT OF LIGHTNING PROTECTION AND OPERATING VOLTAGE RELIABILITY OF DISTRIBUTION LINES

Testing of 400 kv GIS

Effect of Absolute Humidity on Flashover Voltage of Insulators

Insulator Testers Frequently Asked Questions. September Version: 1.1

TECHNICAL SPECIFICATION

Minimum Leakage Current for Dry Band Formation under Polluted Environment

SOUTH AFRICAN NATIONAL STANDARD

شركة الوقت للكهرباء والمقاوالت ذ.م.م.

Tab 2 Voltage Stresses Switching Transients

CVVOZE Power Laboratories (CVVOZEPowerLab)

PREVENTING FLASHOVER NEAR A SUBSTATION BY INSTALLING LINE SURGE ARRESTERS

Extended analysis versus frequency of partial discharges phenomena, in support of quality assessment of insulating systems

Australian/New Zealand Standard

Type Test of a 145 kv Termination Type TS 145-II

EI HIGH VOLTAGE INSULATION TESTING POLICY

700 Series AC Dielectric Test Sets

IDAX 300 Insulation Diagnostic Analyzer. Dielectric Frequency Response Also known as: Frequency Domain Spectroscopy

International Journal of Advance Engineering and Research Development. Comparison of Partial Discharge Detection Techniques of Transformer

IEC/CIGRE UHV Symposium Beijing Paper 4.2. Challenges on the measuring and testing techniques for UHV AC and DC equipment

In-Service Testing and Diagnosis of Gapless Metal Oxide Surge Arresters According to IEC

DEPARTMENT OF ELECTRICAL ENGINEERING DIT UNIVERSITY EHV AC AND DC TRANSMISSION

UltraSIL Polymer-Housed Evolution Distribution Class Surge Arrester Certified Test Report

Insulation Co-ordination For HVDC Station

Transformer Factory Testing

INTERNATIONAL STANDARD

ANSI DESIGN TEST REPORT Report No. EU1295-H-00 Type PVN Station Class Surge Arrester

HIGH VOLTAGE CIRCUIT BREAKERS

INTERNATIONAL STANDARD

Mitigating Murphy s Law While Test. Frédéric Dollinger

Tab 8 Surge Arresters

TECHNICAL NOTE 2.0. Overvoltages origin and magnitudes Overvoltage protection

Energy Division. Bowthorpe LV/MV Surge Arresters

INTERNATIONAL STANDARD

Introduction. AC or DC? Insulation Current Flow (AC) 1. TECHNICAL BULLETIN 012a Principles of Insulation Testing. Page 1 of 10 January 9, 2002

Advancements in online partial discharge monitoring and assessment of MV through EHV Substation assets

4. Classification E: High capacity. 3. Terminal Form Blank: Tab terminals (#250 terminals) Tab terminals #250 SPST-NO

LIGHTNING ARRESTOR. September 2017 WEST BENGAL STATE ELECTRICITY TRANSMISSION COMPANY LIMITED

INTERNATIONAL STANDARD

TRANSFORMER OPERATIONAL. Principles, Selection & Troubleshooting

EE059: Transformer Operation, Maintenance, Diagnosis & Testing

Type 297, High-Voltage Mica Capacitors Corona-free Mica Coupling Capacitors for Medium-Voltage PDA s

FGJTCFWP"KPUVKVWVG"QH"VGEJPQNQI[" FGRCTVOGPV"QH"GNGEVTKECN"GPIKPGGTKPI" VGG"246"JKIJ"XQNVCIG"GPIKPGGTKPI

SURGE ARRESTERS AND TESTING. Keith Hill Doble Engineering Company

TT 0710/03. TYPE TEST OF 3 Phase Solid Earthing Bonding Link Box, Type: LB.W.3SA.3.1

LESSON PLAN LP-EE Sub Code: EE 2353 Sub Name: HIGH VOLTAGE ENGINEERING Unit: I Branch: EEE Semester: VI

Compact Systems for HVDC Applications Dr. Denis Imamovic

USING DAMPED AC VOLTAGES

PUSHING THE BOUNDARIES OF INDUCTIVE VOLTAGE TRANSFORMER DESIGN

Computer Based Model for Design Selection of Lightning Arrester for 132/33kV Substation

Matz Ohlen Director Transformer Test Systems. Megger Sweden

Secondary Arresters. Figure 1. Type L secondary surge arrester rated 175 Vac, 125 Vdc.

Tests on Extruded Cables

Transient fault Detection and Analysis of Distribution Transformers using Transform based Techniques

RESONANT TRANSFORMER

Overvoltage Protection

WIRE AND CABLE ENGINEERING GUIDE

Transcription:

CHAPTER 10 HIGH VOLTAGE TESTING OF ELECTRICAL APPARATUS 1. Introduction 2. Classification of High Voltage Tests 3. Test Voltages 4. High Voltage Testing of Electrical Apparatus

1. INTRODUCTION Purpose of the testing: To ensure that the electrical equipments are capable of withstanding the overvoltages that are met with in service. Covers basic requirements procedures for testing on several electrical apparatus. Normally, high voltage (HV) testing is to investigate the insulation performance. International/national specifications for testing are outlined (details of test, specific equipment, procedure and acceptable limits) to meet the users and manufacturers requirements.

2. CLASSIFICATION OF HIGH VOLTAGE TESTS Destructive Test Normally the equipment underwent destructive test cannot be used in the service. Test voltage is higher than its normal working voltage. Breakdown test.

Con t Non-Destructive Test Mainly done to assess the electrical properties, eg. Resistivity, dielectric constant and loss factor. The apparatus is not destroyed during the test and can be used again.

2.2 TYPES OF TESTS 1. Routine Tests Made by the manufacturer on every finished piece of product. To fulfills the specifications. 2. Type Tests Performed on each type of equipment before their supply on a general commercial scale demonstrate performance characteristics. No need to repeat the test unless changes are made in the design of the product.

Con t 3. Maintenance Tests Usually carried out after maintenance/repair of the equipment. Conducted according to schedule provided. Purpose of the test : To ensure the equipment lifetime is achieved.

Types of tests The range of high voltage tests depends on the nature of the equipment being tested

3.0 TEST VOLTAGES powerfrequency alternating voltages (AC) Direct voltages (DC) impulse voltages. TEST VOLTAGES

Con t Test with Direct Voltage (DC). Mainly to test equipment used in HVDC transmission systems. Insulation testing, fundamental investigations in discharge physics and dielectric behavior. Rate of voltage rise above 75% of its estimated final value should be about 2% per second.

Con t Test with Alternating Voltage (AC). Frequency range : 40-60 Hz, sinusoidal shape. Dry withstand test : Most common routine test for all types of electrical equipment especially insulators, bushing, rod gaps etc. Applied voltage between two to three times of the normal working voltage.

Con t Test with Alternating Voltage (AC) cont. Wet withstand test : To simulate the effect of natural rain on external insulation. Recommended for tests on apparatus which are designed for outdoor used. Use artificial rain. Applied for 30-60 seconds.

Con t Test with Impulse Voltage. Is designed to investigate the insulation performance due to the lightning stroke or Lightning impulse chopped on the front switching operation. 3 types of impulse voltages, ie; 1) Full wave 2) Chopped wave 3) Switching wave BS 923: Part 2: 1980

Con t BS 923: Part 2: 1980 Lightning impulse chopped on the tail Full switching impulse

Con t Rated impulse withstand test For test on non-self-restoring insulation, 3 impulses are applied. For withstand tests on self-restoring insulation, 2 procedures are used: 1) 15 impulses (rated withstand voltage) with the specified shape and polarity are applied 2) Test procedure for determining 50% disruptive discharge voltage is applied The method used for determining the levels of applied voltage is up-and-down methods.

Atmospheric Correction Factors The electrical characteristics of the insulators and other apparatus are normally referred to the reference atmospheric conditions. According to the British Standard Specifications, they are: Temperature : 20 o C Pressure : 1013 millibars (or 760 torr) Absolute humidity : 11 gm/m 3 Since it is not always possible to do tests under these reference conditions, correction factors have to be applied.

Atmospheric Correction Factors V 0 = voltage under actual test conditions, V s = voltage under reference atmospheric conditions, h = humidity correction factor, and d = air density correction factor. The air density correction factor is given by, where, b = atmospheric pressure in millibars, and T= atmospheric temperature, o C.

Humidity correction factor h is obtained from the temperatures of a wet and dry bulb thermometer, by obtaining the absolute humidity and then computing h from the absolute humidity.

Example 1 Sarzaminor conducted an AC flashover test at power frequency on a cap and pin insulator for his FYP project. From the test, it was found that flashover occurred at 80 kv. If the dry and wet temperatures during the test were 25 C and 22 C respectively, and atmospheric pressure was at 1 atm, determine the flashover voltage under the reference atmospheric condition.

Example 1 Dry Temp. = 25 C Wet Temp. = 22 C Absolute humidity = 18g/m 3 18

Example 1 Dry Temp. = 25 C Wet Temp. = 22 C 1 atm = 1013.25 milibar h=0.92 0.92

4.0 HIGH VOLTAGE TESTING OF ELECTRICAL APPARATUS Transformer Circuit breaker Insulator Cable

Impulse testing on transformer According to BS 171: Part 3. Carried out at room temperature with the transformer not energized. Used standard impulse waveshapes. Full and chopped waves. Impulse Test Temperature Rise Test A change in the waveshape of the voltage and current both before and after the chopped waves have been applied. The existing of acoustic noise. Visual signs of flashover Failure detection (Insulation failure) Short Circuit test

Testing of Circuit Breaker (BS 5227: Part 2, IEC 56) Consist of overvoltage withstand tests of power frequency, lightning and switching impulse voltages. Circuit breaker in both the open and closed positions Dielectric tests or overvoltage tests, Temperature rise and mechanical tests Type test The most important test on circuit breaker since these tests assess the primary performance of these devices, i.e. their ability to safely interrupt the fault currents Short Circuit Tests

Short Circuit Test Methods of conducting short circuit tests are (I) Direct Tests (a) using a short circuit generator as the source (b) using the power utility system or network as the source. (II) Synthetic Tests Consists of two separate sources : one power source acting as a current source supplying the required short-circuit current at a (relative) lowvoltage level and a second source working as a voltage source supplying the required voltage. Based on the fact that for certain (short circuit) tests the test object is stressed by a high current and by a high voltage at different time periods.

Tests on Insulator Power Frequency Test Dry and Wet flashover test Dry and Wet Withstand test increased at a uniform rate of about 2 % per second of 75% of the estimated test voltage Voltage applied under dry or wet conditions for a period of 1 minute with an insulator mounted as in service conditions. The test piece should withstand the specified voltage. Test on Insulator Impulse Tests Impulse Withstand Voltage Test Impulse Flashover Test Both positive and negative polarities Insulator passed the test if five consecutive waves do not cause flashover or puncture Pollution Testing Due to outdoor electrical insulation and consequent problems of the maintenance of electrical power systems. Eg. Dust, industrial pollution (smoke & petroleum vapor), desert pollution, snow Pollution causes corrosion, nonuniform gradients, deterioration of the material, partial discharges and radio interference.

Routine and Type test on cables According to BS 923: Part 2, IEC 60-2, IEC 55-1, IEC 230 and BS6480. Different tests on cables may be classified into I. mechanical tests like bending test, dripping and drainage test, and fire II. III. IV. resistance and corrosion tests, dielectric power factor tests, power frequency withstand voltage tests, (a.c. voltage of 2.5 limes the rated value for 10 min.) V. Dc withstand voltage tests, (1.8 times the rated d.c. voltage of negative polarity for 30 min) VI. Impulse withstand voltage tests, (withstand five impulse of prescribed magnitude without any damage VII. partial discharge tests,