GAMMA 10 DIGITAL MULTIMETER

Similar documents
GAMMA 12 DIGITAL MULTIMETER

Technical Data Sheet. Gamma 12. Gamma 12

RISH Multi 12S...18S Analog - Digital multimeters

Data Sheet. Analog - Digital Multimeter. RISH Multi RISH Multi Analog-Digital Multimeter. Page 1 of 6. Rishabh Instruments

GAMMA 20 DIGITAL MULTIMETER

SUBJECT TO CHANGE WITHOUT NOTICE

Analog Digital Multimeter with Insulation Resistance Measurement

RISH MIT 30 Analog Digital Multimeter with Insulation Resistance Measurement

Technical Data Sheet. Delta 1000/300

Data Sheet. RISH Max-14 Analog-Digital Multimeter. RISH Max-14 Analog-Digital Multimeter. Page 1 of 5. Rishabh Instruments 1 / 05 / IX / 1210 / B

Technical Data Sheet. Zeta 20

RISH Max-12 and 14 Analog-Digital Multimeter. Data Sheet. RISH Max-12 and 14 Analog-Digital Multimeter. Rishabh Instruments

METRA 22 26S/M Analog-Digital Multimeters with Signal Generator

METRAHIT WORLD. International TRMS Multimeter /2.16. Features

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information

Laboratory for Fundamentals of Electrical Engineering (Labor Grundlagen der Elektrotechnik) Equipment Manuals for use in laboratory for measurement

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

1587/1577 Insulation Multimeters

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

Model ST Instruction Manual. True RMS Autoranging Digital Multimeter. reedinstruments. www. com

Digital-Multimeter UNIGOR 380, 390

APPA 300 Series. The Most User-Friendly High Performance Multimeter

N24, N25 DIGITAL PANEL METER

DVM98. True RMS Digital Multimeter. 1 Safety information. 1.1 Preliminary. 1.2 During use

BENNING. Service Information MODEL: MM1-1 / MM1-2 / MM1-3

Fluke 83V and 87V Digital Multimeters

DVM1190 DIGITAL MULTIMETER

Digital-Multimeter UNIGOR 380, UNIGOR 390

DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL-860A OPERATION MANUAL

79/26 Series III Multimeter

AC/DC DIGITAL CLAMP METER OPERATION MANUAL

DIGITAL MULTIMETERS. Accuracy +5% Resolution 1pF Accessories Test leads, Manual, 9V Battery included Options ST-265, C-90, C W x 6 L x 1.

ALPHA 20 MULTIFUNCTION METER (ALPHA SERIES)

OPERATOR S INSTRUCTION MANUAL

USER'S MANUAL DMR-6700

METRAClip87 and 88 Clamp Multimeters

# Digital Multimeter

ETHOS 5030 TRUE-RMS DIGITAL MULTIMETER OPERATION MANUAL

User's Guide Extech EX Amp Clamp Meter with IR Thermometer

Autoranging Multimeter Extech EX503

Operating Instructions METRA HIT 16I/L/T. Analog Digital Multimeter with Insulation Measurement /5.06

Thank you again for choosing AstroAI, if you have any questions or concerns regarding your product, please contact us at

METRAHit 30M Precision Digital Multimeter

Insulation Testers and Earth Ground Testers

User s Manual. MiniTec TM Series. Model MN26 (Model MN26T includes temperature probe) Mini Autoranging MultiMeter

User's Guide. Extech 800 Series 1000 Amp Clamp Meters with IR Thermometer

BENNING. CM7 Electrical Tester. Service Information

INSTRUCTION MANUAL. Model Autoranging DMM ProbeMeter TM. Measures voltage, resistance, frequency, capacitance, temperature, and duty cycle.

OPERATOR S INSTRUCTION MANUAL M-2625 AUTO RANGING DIGITAL MULTIMETER

MM700. True RMS ENGLISH. INSTRUCTION MANUAL Auto-Ranging. Measurement Technology

Compact Autoranging Clamp Meters. Models (400 A AC), (400 A AC/DC)

EUROPE S LARGEST SELECTION OF TEST & MEASUREMENT EQUIPMENT FOR HIRE INLEC.COM. Nationwide Low Call

USER'S MANUAL ACDC-100 TRMS ACDC-100. Versatile AC/DC Clamp-on Multimeter Series

User's Guide. 800 Amp AC/DC True RMS Clamp Meter. Model EX Washington Street Melrose, MA Phone Toll Free

AC/DC CLAMP METER USER S MANUAL

ALPHA 50 MULTIFUNCTION METER (ALPHA SERIES)

EM420A/420B DIGITAL MULTIMETER OWNERS MANUAL Read this owners manual thoroughly before use

Fluke 1587 FC/1577 Insulation Multimeters

Item ref: UK MTTR01 TRUE RMS DIGITAL MULTITESTER WITH USB INTERFACE. User Manual

Data sheet IDM 99III Digital Multimeter

NOTE: Fully read and understand this manual before using this Digital Multimeter.

Current Clamp. 210

ENGLISH. Datasheet Stock No RS PRO IDM 99III Digital Multimeter. Feature: 6000 count digital display with 62 segment bar graph

Data sheet IDM 98III Digital Multimeter

Sales: Technical: Fax:

ENGLISH. Datasheet Stock No RS PRO IDM 98III Digital Multimeter. Feature: 6000 count digital display with 62 segment bar graph

METRA HIT 28C Calibrator, Multimeter and Milliohmmeter

MM700. INSTRUCTION MANUAL Auto-Ranging Digital Multimeter True RMS

Accuracy : ± (0.8% rdg + 1dgt) on all ranges except Ranges : 200mV, 2V, 20V, 200V, 1000V

1. SAFETY 1.1. SAFETY INFORMATION 1.2. SAFETY SYMBOLS

OWNER S MANUAL HH0308C. AUTO-RANGING DC/True RMS AC DIGITAL MULTIMETER

DIGITAL MULTIMETER. MODEL CDM-50 Part No OPERATING INSTRUCTIONS

EX360 Series USER MANUAL. True RMS Digital Multimeters. EX360 True RMS Digital Multimeter EX363 True RMS DMM with Temperature and µa AC/DC

BENCH METER Model>9803. Wavecom Instruments

METRAClip85 and 86 Clamp Multimeters

User's Guide Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX330

METRAVI. Table of Contents

MM V 10A ENGLISH. INSTRUCTION MANUAL Auto-Ranging DATA HOLD AUDIBLE CONTINUITY MIN / MAX TEMPERATURE DIODE TEST CAPACITANCE

2000 A AC TRUE RMS DIGITAL CLAMP METER WITH NON-CONTACT EF-DETECTION

Digital Multimeter with Backlight

User Manual. All rights reserved. Specifications are subject to change without notice.

Dawson DDM230C. True RMS Multimeter with Bar Graph Display User s Manual

OPERATING INSTRUCTION

METRAHIT T-COM Cable Multimeter for Measurements in Symmetrical Copper Cable Networks

User s Guide. 400A AC/DC Clamp Meter. Model MA220

The Meter Structure The Figure 2-1 shows the Meter structure.

Indeks: WMXXCMM60 Advanced Industrial Multimeter

400Amp True RMS AC/DC Clamp Meter Model EX613

Model 77 Series IV. Digital Multimeter. Users Manual

INSTRUCTION MANUAL ACD-10 PRO & TRMS PRO

SDM3045X Digital Multimeter. DataSheet

Instruction Manual IDM 66RT Digital Multimeter

METRA HIT 22 26S/M Analog-Digital Multimeters with Signal Generator

200Amp AC Clamp Meter + NCV Model MA250

Agilent 970-Series Handheld Multimeters Data Sheet

MS8250A/B OPERATION MANUAL MS8250A. Hz% FUNC REL RANGE REL HOLD OFF 10A. Hz% A NCV. Hz% COM. A ma 10A FUSED 600V CAT IV.

AM-510 Commercial / Residential Multimeter. AM-510-EUR Digital Multimeter. Users Manual

DM-45 Digital Multimeter

Item ref: UK MTM01 DIGITAL MULTITESTER. User Manual

DVM645BI BENCH MULTIMETER TAFELMULTIMETER MULTIMETRE DE TABLE BANCO MULTÍMETRO TISCHMULTIMETER. User Manual. Gebruikershandleiding

Transcription:

Gamma 10 www.sifamtinsley.co.uk DATASHEET Issue 1.0 Multifunction Meters Transducers & Isolators Temperature Controllers Converters & Recorders Digital Panel Meters Current Transformers Analogue Panel Meters Shunts Digital Multimeters GAMMA 10 DIGITAL MULTIMETER Gamma 10 is Analogue Digital Multimeter which measures VAC, VDC, VAC+DC, Frequency, ma DC, ma (AC+DC), Resistance, continuity, Diode, Farad, AC current measurement. Features Automatic terminal blocking system (ABS) Min/Max value storage Indication of negative values on the analogue scale Overload warning Clamp Meters Insulation Testers SUBJECT TO CHANGE WITHOUT NOTICE This manual superseded all previous versions please keep for future reference

Application Gamma 10 is Analogue Digital Multimeter which measures VAC, VDC, VAC+DC, Frequency, ma DC, ma (AC+DC), Resistance, continuity, Diode, Farad, AC current measurement. Product Features Automatic Terminal Blocking System (ABS) Interface And Software RISH com 100 MIN / MAX Value Storage Indication Of Negative Values On The Analogue Scale Indication Of Negative Values On The Analogue Scale Automatic Data Hold* Autoranging / Manual Range Selection The automatic Terminal blocking system prevents incorrect connection of the test leads and incorrect selection of the measured quantity. This reduces danger to the user, the meter and the system to a remarkable extent. The multimeters are fitted with a serial RS-232 C interface via which the measured values can be transmitted to a PC. These values, electrically isolated, are transmitted to the attachable interface adaptor with infrared light through the case* In addition to the display of the actual measured value, the minimum or maximum value can constantly be updated and stored. When measuring DC quantities, also negative values are shown on the analogue scale so that variations of the measured value can be observed at the zero point. The measuring principle employed permits the measurement of the root-mean-square value (TRMS) of AC quantities and mixed quantities (AC and DC) regardless of the waveform. The DATA HOLD function makes it possible to hold the digitally displayed measured value. According to a patented method, it is ensured that no freak value but the actual measured value is held in the case of rapid changes in measured quantities. The held measured value appears on the digital display. The actual measured value continues to be shown on the analogue scale. The measured values are selected with rotary switch. The measuring range is automatically matched to the measured value. The measuring range can also be selected manually via the AUTO/MAN push button Continuity Test This permits testing for short circuit and open circuit. In addition to the display, a facility of sound signal is available. Temperature It is possible to use all models of Gamma 12, Measurement in direct connection of temperature sensor Pt 100 / Pt 1000. The meters automatically detects the type of sensors connected to it & displays directly measured temperature. Signalling in the The display FUSE points to a blown fuse. case of a blown fuse Power The meter disconnects automatically when the economizing circuit measured value remains unchanged for about 10 minutes and no operating control was operated during this time. The disconnection facility can be disabled. Overload A sound signal indication violation of the Warning overload limits. Protective A holster of soft rubber with tilt stand protects holster for rough the meter against damage in the case of shock duty and drop. The rubber material makes for the meter to stand firmly even on vibrating surface. Top model The top model Gamma 10 features a 4 3/4 Gamma 10 Calibration digit display (31 000 digits)as well as the following additional functions : Event counter, measurement of the duration of the event, time counter (stop watch), data compare, db measurement, wide-range capacitance measurement. Gamma mutli is automatically calibrated with respect to Fluke 5500 / Wavetek 9100. Automatic calibration is done through a developed calibration software with RS232 connection to the multimeter. Every multimeter is provided with the Test Certificate which is traceable to National / International standards. All the meters can be recalibrated at the Rishabh Instruments. Issue 1.0 Gamma 10 1

Analogue Indication LCD scale with pointer Scale length 55 mm on V and A ; 47 mm on all other ranges Scaling + 5 0 + 30 with 35 scale divisions on 0 30 with 30 scale divisions on all other ranges Polarity indication With automatic reversal Overrange indication By triangle Sampling rate 20 readings/s, On 10 readings/s Environmental conditions Temperature range -20 0C... + 50 C0 Storage temperature -25 0C... +70 0C (excl. batteries) range Climatic class 2z/-20/50/70/75% with reference to VDI/VDE 3540 Altitude above sea level up to 2000m Mechanical Configuration Protection type For meters; IP 50, for connection sockets: IP 20 Dimensions 84 mm x 195 mm x 35 mm Weight 0.35 kg, approx., incl. battery Applied rules and standards IEC 61010-1:2001 Safety requirements for electrical DIN EN 61010 part 1 equipment for measurement, VDE 0411-1 control and laboratory use. DIN 43751 IS 13875 Digital measuring instruments EN 61326:2002 Generic emission standard; Residential, commercial and light industry EN 61326:2002 Generic immunity standard; residential, commercial and light industry VDI/VDE 3540 Reliability of measuring and control equipment. DIN EN 60529 Test equipment and test procedures DIN VDE 0470 part 1 -Degrees of protection provided by enclosures (IP Code) Digital Display/ height of numerals Number of counts Overange display Polarity display Sampling rate 7 segment numerals / 12mm 4 ¾ digit 31000 counts "OL" is shown "-" sign is shown, When positive pole to 2 readings/s, On and 0C:1 reading/s Warranty 3 year against defects in materials and workmanship & calibration from the date of purchase. Scope of delivery 1 multimeter 1 Probe Set 1 copy of operating instructions 1 test certificate 1 rubber holster with tilt stand and carrying strap warranty card 1 set of extra fuses Display LCD field (65 mm x 30mm) with analogue indication and digital display and with annuciators for unit of measurement, function and various special functions. 1 Display with low battery voltage 2 Display with sound signal on 3 Symbol for CONTINUOUSLY ON 4 Digital display with indication of decimal point and polarity 5 Display with manual range selection as well as with data and MIN/MAX hold 6 Display of the selected function 7 Display of the unit of measurement 8 Display with overrange 9 Pointer for analogue indication 10 Scale for analogue indication 11 Indication that negative analogue range is exceeded 12 Display of the unit 0C when measuring temperature 13 Display with time counter switched on 2 Gamma 10 Issue 1.0

Reference conditions Measuring current with diode test and / or continuity test Ambient temperature +23Co + 2K Relative humidity 45%... 55% Frequency of the 45 Hz... 65 Hz measured quantity Waveform of the Sinusoidal measured quantity 8V + 0.1 V Battery voltage Inherent error of the digital display Input impedence + (...% of rdg.+... digits Overload capacity 2) at reference conditions Meas. Measuring Resolution Overload Overload Meas. function range value duration function V 300.00 mv 10 µv >10 GΩ 5 MΩ // < 40 pf 0.05 + 3; 0.05 + 20 1.0 + 30 (> 600 Digit) 1000 V V 3.0000 V 100 µv 11 MΩ 5 MΩ // < 40 pf 0.05 + 3 0.5 + 30 (> 300 Digit) DC 30.000 V 1 mv 10 MΩ 5 MΩ// < 40 pf 0.05 + 3 0.5 + 30 (> 300 Digit) AC cont. 300.00 V 10 mv 10 MΩ 5 MΩ // < 40 pf 0.05 + 3 0.5 + 30 (> 300 Digit) RMS 1000.0 V 100 mv 10 MΩ 5 MΩ // < 40 pf 0.05 + 3 0.5 + 30 (> 300 Digit) sinusoidal db db See table below as at V + 0.5 db Voltage drop. approx. ma 300.00 µa 10 na 15 mv 15 mv 0.2 + 20 1.2 + 30 (> 300 Digit) 0.36 A cont. ma 3.0000 ma 100 na 150 mv 150 mv 0.2 + 10 1.2 + 30 (> 300 Digit) 30.000 ma 1 µa 30mV 30mV 0.05 + 10 1.2 + 50 (> 300 Digit) 300.00 ma 10 µa 300 mv 300 mv 0.2 + 10 1.2 + 30 (> 300 Digit) A 3.0000 A 100 µa 150 mv 150 mv 0.5 + 10 1.2 + 50 (> 300 Digit) 12A 5) 5 min A 10.000 A 1 ma 400 mv 400 mv 0.5 + 10 1.2 + 30 (> 300 Digit) No-load voltage Short circuit current Ω 300.00 Ω 10 m Ω max. 4.00 V max. 1 ma 0.1 + 6; 0.1 + 30 1000 V 3.0000 k Ω 100 m Ω max. 1.25 V max. 100 µa 0.1 + 6 DC 30.000 k Ω 1 Ω max. 1.25 V max. 10 µa 0.1 + 6 AC 1 min 300.00 k Ω 10 Ω max. 1.25 V max. 1 µa 0.1 + 6 RMS 3.0000 M Ω 100 Ω max. 1.25 V max. 0.1 µa 0.1 + 6 sinusoidal 30.000 M Ω 1k Ω max. 1.25 V max. 0.1 µa 1.0 + 6 3.0000 V- 1 mv max. 4.00 V 0.2 + 3 Ω Discharge resist U 0max 3.000 nf 1 pf 1.5 M Ω 4 V 1.0 + 8; 1.0 + 60 1000 V 30.00 nf 10 pf 1.5 M Ω 4 V 1.0 + 8; 1.0 + 30 DC 300.0 nf 100 pf 150 k Ω 4 V 1.0 + 3 AC F 3.000 µf 1 nf 150 k Ω 4 V 1.0 + 3 RMS 1 min F 30.00 µf 10 nf 15 k Ω 2 V 1.0 + 3 sinusoidal 300.0 µf 100 nf 1.5 k Ω 2 V 5.0 + 6 3000 µf 1 µf 1.5 k Ω 2 V 5.0 + 6 10000 µf 10 µf 1.5 k Ω 2 V 5.0 + 6 Issue 1.0 Gamma 10 3

Inherent error of the digital display Input impedence + (...% of rdg.+... digits Overload capacity 2) at reference conditions Meas. Measuring Resolution Overload Overload Meas. function range value duration function f min 6) Hz 300.00 Hz 0.01 Hz 10 Hz 3 khz; Hz 1000 V 3.0000 khz 0.1 Hz 10 Hz 0.1 + 3 7) 30 khz; cont. 300 V 30.000 khz 1 Hz 10 Hz 100 khz; 100.00 khz 10 Hz Pt - 200.0... 0.1 C 0.5 Kelvin + 3 8) 1000 V 100 + 100.0 C DC + 100.0... 0.1 C 0.5 + 3 8 AC 1 min. C + 850.0 C rms C - 100.0... 0.1 C 0.5 Kelvin + 3 8) sine Pt + 100.0 C 1000 + 100.0... 0.1 C 0.5 + 3 8) + 850.0 C db ranges Measuring Display span Display span Ranges at reference voltage at reference voltage U = 0.775 V Uref (V) 300 mv - 48 db... - 8 db - 40 db... + 110 db 3 V - 38 db... + 12 db -60 db... + 100 db 30 V - 18 db... + 32 db - 80 db... + 80 db 300 V + 2dB... + 52 db - 100 db... + 60 db 1000 V + 22 db... + 63 db - 110 db... + 40 db Display (db) = Display (db) = 20 lg U x (V) / 0.775 V 20 lg U x (V) / U ref (V) TRMS measurement 2) At - 10 C... + 40 C 3) With zero adjuster; without zero adjuster 4) At a resolution of 0.01 db 5) 16 A for 30s 6) Lowest measurable frequency with a sinusoidal measuring signal which is symmetrical to zero 7) Range 3 V : Ue = 1V eff/rms 10 V eff/rms 30 V : Ue = 10V eff/rm..s. 100 V eff/rms 300 V : Ue = 100V eff/rm.s.. 1000 Veff/rms 8) Without sensor Measuring voltage with resistance measurement Voltage Ux across the resistance Rx to be measured as a function of measuring range and display. 4 Gamma 10 Issue 1.0

Measuring current with diode test and / or continuity test Measuring current Ix as a function of the displayed voltage Ux on the device undertest. Operating controls Issue 1.0 Gamma 10 5

Ordering Information GM20-7NB4000000000 GM20-7FB4000000000 GAMMA 10 Gamma 10 TRMS Backlit Gamma 10 Fine Tip TRMS Backlit Contact Sifam Tinsley Instrumentation Ltd 1 Warner Drive Springwood Industrial Estate Braintree, Essex CM7 2YW Tel: 01376 335271 E-mail: sales@sifamtinsley.com www.sifamtinsley.co.uk 6 Gamma 10 Issue 1.0