3B SCIENTIFIC PHYSICS

Similar documents
3B SCIENTIFIC PHYSICS

Analogue Demo Multimeter ADM

AMM-1022 Digital Multimeter USER`S MANUAL

User Manual Digital Multimeter

MAVOWATT 4 Multifunction Power Meter

ProfiScale MULTI Multimeter

USER MANUAL 600A AC Clamp Meter + NCV Model MA610

1. SAFETY INFORMATION.1 2. DESCRIPTION SPECIFICATIONS.6 4. OPERATING INSTRUCTION Voltage measurement Current measurement 10

DVM1190 DIGITAL MULTIMETER

Digital Multimeter with Backlight

AC/DC Current Probe GCP-100 QUICK START GUIDE ISO-9001 CERTIFIED MANUFACTURER

30XR-A Professional Digital Multimeter Users Manual

PEN TYPE DIGITAL MULTIMETER OPERATION MANUAL T8211D

DVM645BI BENCH MULTIMETER TAFELMULTIMETER MULTIMETRE DE TABLE BANCO MULTÍMETRO TISCHMULTIMETER. User Manual. Gebruikershandleiding

MS2030 CAT III 600 V A V AUTO RS232

Operating Instructions / Voltage Tester per IEC with Phase and Polarity Tester and Phase Sequence Indicator

Analog Technologies. Multimeter 15B and17b

Digital Clamp Meter Model: &

INSTRUCTION MANUAL DIGITAL MULTIMETER

Operating Instructions METRA HIT 1A/2A /1.10. Analog Multimeter

3B SCIENTIFIC PHYSICS

Thank you again for choosing AstroAI, if you have any questions or concerns regarding your product, please contact us at

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information

Item ref: UK MTM01 DIGITAL MULTITESTER. User Manual

Model True RMS AC/DC 30A Mini Clamp-on Meter. User Guide

HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL

OPERATOR S INSTRUCTION MANUAL

KMD-S04 Multímetro de bolsillo

USER'S MANUAL DMR-6700

DM-45 Digital Multimeter

Model DIGITAL MULTIMETER

Model : OPERATING MANUAL Table of Contents (1)

DIGITAL MULTIMETER OPERATOR'S INSTRUCTION MANUAL HOLD 10A COM LIGHT MS8265 ON/OFF. 200M KHz 2K 20K μ μ μ n.

USER MANUAL. Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX330

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

Data Sheet. RISH Max-14 Analog-Digital Multimeter. RISH Max-14 Analog-Digital Multimeter. Page 1 of 5. Rishabh Instruments 1 / 05 / IX / 1210 / B

Digital Clamp Meter. User Manual

DVM98. True RMS Digital Multimeter. 1 Safety information. 1.1 Preliminary. 1.2 During use

Compact MultiMeters + Voltage Detector

MultiMeter-Pocket CAT III 1000 V

Instruction Manual for Digital Grounding Resistance Meter

15B+/17B+/18B+ Calibration Manual. Digital Multimeter

Model 77 Series IV. Digital Multimeter. Users Manual

BENNING. CM7 Electrical Tester. Service Information

DIGIT & POINTER MULTIMETER

NOTE: Fully read and understand this manual before using this Digital Multimeter.

Instruction Manual ICM 3091N Digital AC Clampmeter EN FR IT DE ES

Model: &

Model ST Instruction Manual. True RMS Autoranging Digital Multimeter. reedinstruments. www. com

Multifunction AC/DC Voltage Tester

METRISO. Analog Insulation, Low Resistance and Voltage Measurement Instrument /9.14

400 MHz Passive High-Voltage Probe R&S RT-ZH

AC/DC Clamp Meter. Owner's Manual. Model No Safety Operation Maintenance Español

AM-510 Commercial / Residential Multimeter. AM-510-EUR Digital Multimeter. Users Manual

15B & 17B. Multimeters. Users Manual

MS8211 DIGITAL MULTIMETER INSTRUCTION MANUAL

UT207A/208A/209A Operating Manual. Table of Contents

PHV RO High Voltage Passive Probe. Instruction Manual

AM-500 Autoranging Mulitmeter. AM-500-EUR Digital Multimeter. Users Manual

PHV 1000-RO High Voltage Passive Probe. Instruction Manual

79/26 Series III Multimeter

Model UT20B: OPERATING MANUAL Table of Contents (1)

1. SAFETY 1.1. SAFETY INFORMATION 1.2. SAFETY SYMBOLS

USER. manual. Falco Systems WMA-100. High Voltage Amplifier DC - 500kHz

Item ref: UK MTTR01 TRUE RMS DIGITAL MULTITESTER WITH USB INTERFACE. User Manual

User s Guide. 400A AC/DC Clamp Meter. Model MA Washington Street Melrose, MA Phone Toll Free

PKT 512A-RO High Impedance Passive Cable Divider

312, 316, 318. Clamp Meter. Users Manual

15B & 17B. Users Manual. Multimeters

DIGITAL MULTIMETER INSTRUCTION MANUAL

EM420A/420B DIGITAL MULTIMETER OWNERS MANUAL Read this owners manual thoroughly before use

TWS One Vocal UHF wireless system. user manual

BENNING. Service Information MODEL: MM1-1 / MM1-2 / MM1-3

MS8223A. CAT.IIi 600 V

METRAHIT WORLD. International TRMS Multimeter /2.16. Features

User's Guide. 800 Amp AC/DC True RMS Clamp Meter. Model EX Washington Street Melrose, MA Phone Toll Free

OPERATOR S INSTRUCTION MANUAL M-2625 AUTO RANGING DIGITAL MULTIMETER

DIGITAL MULTIMETER CONTENTS DIGITAL MULTIMETER CONTENTS

USER'S MANUAL ACDC-100 TRMS ACDC-100. Versatile AC/DC Clamp-on Multimeter Series

RISH Max-12 and 14 Analog-Digital Multimeter. Data Sheet. RISH Max-12 and 14 Analog-Digital Multimeter. Rishabh Instruments

USER MANUAL. Model MA A AC Mini Clamp-on Meter. Additional User Manual Translations available at

Model UT10A: OPERATING MANUAL Table of Contents (1)

Dawson DDM181. Pocket-Size Autorange Digital Meter User s Manual

MS8268 HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL

400Amp True RMS AC/DC Clamp Meter Model EX613

TWS One Headset UHF wireless system. user manual

EX350 Series USER GUIDE. True RMS Digital Multimeters. EX350 True RMS Digital Multimeter EX355 True RMS Digital Multimeter with Temperature

CONTENTS MS2033A. 1.Introduction Safety Information...01

Pince Multimètre - Courants de fuites Leakage Clamp-on Meter Multimeter und Fehlerstrom-Messzange Pinza Multimetro - Correnti di fuga

Digital Multimeter, Pen Type

Pen-type DIGITAL MULTITESTER

Sales: Technical: Fax:

Dawson DDM190. Digital Multimeter User s Manual

R/C SMD Tweezers Multimeter Model RC200

Analog Technologies. Multimeter 115C and 117C

AC/DC Current Oscilloscope Probe Model SL261

MANUAL DE INSTRUÇÕES DO MULTÍMETRO DIGITAL MODELO MD-6456 Inglês

Table of Content. The Statement Safety Statement Safety Instructions Safety Operation Specifications Safety Symbols...

MM V 10A ENGLISH. INSTRUCTION MANUAL Auto-Ranging DATA HOLD AUDIBLE CONTINUITY MIN / MAX TEMPERATURE DIODE TEST CAPACITANCE

GAMMA 20 DIGITAL MULTIMETER

Transcription:

3B SCIENTIFIC PHYSICS Analogue Multimeter Escola 100 1013527 Instruction sheet 12/15 SD/JS 1 Display with mirror scale 2 Slotted screw for zero calibration 3 Calibration trimmer for setting centre zero point 4 Rotary switch to select the measurement range 5 Four-way switch 6 oltage measurement socket 7 Current measurement socket for up to 3 A and for continuity tests 8 Current measurement socket for up to 10 A 9 Safety ground socket 1. Description The ESCOLA 100 is an electronic meter with a mirrored dial for measurements of current and voltage involving analogue techniques for use in training, education and work placements. The meter can handle measurements of current and voltage values up to 10 A or 600 and also allows the zero point to be set up in the centre of the scale for measurement of DC quantities and for continuity tests featuring an acoustic signal. AC quantities with frequencies of up to 40 khz can be measured. All the possible measuring ranges can be selected by means of a single rotary switch. The device is protected by a fuse and authorised for measurements on wiring installations in (CAT III), e.g. in distribution boxes/consumer units. The current measuring ranges are resistant to longterm overloading up to 10 A. Generous protection of all the current ranges by means of semiconductor circuit breakers prevents the fuse blowing unintentionally in many cases. Switching between measuring ranges does not break any circuits connected to the equipment. This means it is possible to carry out measurements on voltage converters, for example, without causing induction surges. Resistance R, conductance G, impedance Z and admittance Y can easily be determined as quotients of current and voltage measurements thanks to the non-interrupting switch capability without the need to change the wiring. 1

2. Safety instructions The analogue multimeter conforms to safety regulations for electrical measurement, control and laboratory equipment, as specified in DIN EN 61010-1, protection class 2 and to measuring category CAT III for up to 600. The nominal voltage between the phase conductors and the neutral for voltage and current measurements (in circuits directly connected to mains electricity) must not exceed 600 in order to conform to CAT III. The meter is intended for measurements within its measuring ranges and in a measuring environment as described in detail in the course of this manual. Safe operation of the multimeter is guaranteed if it is solely used as specified. Safety cannot be guaranteed, however, if the multimeter is used incorrectly or handled without due care and attention. In order to avoid serious injury due to current or voltage shocks, the following safety instructions are to be observed at all times. The multimeter may only be used by persons who are able to recognise the risks of contact and take due precautions to avoid them. oltages in excess of 33 AC (RMS) or 70 DC are to be regarded as actively dangerous if the current, charge or energy stored should exceed certain values (see DIN EN 61010-1). Carefully read the instruction manual before using the multimeter and obey the instructions therein. The multimeter may only be used in a dry, dust-free environment with no risk of explosions occurring. The assumption needs to be made that unforeseen voltages may be present in the vincinity of objects being measured (e.g. faulty equipment). Before using the multimeter, check the housing and measuring leads for damage and if there should be any malfunctions or visible damage, the multimeter is not to be used. Pay specific attention to the insulation for the measuring sockets. The multimeter may not be used to make measurement on circuits which exhibit corona discharge (high voltage). Particular care is to be taken when making measurements on high-frequency circuits where dangerous voltages may arise due to superimposition of components. The authorised measuring range is not to be exceeded. If measurements are made when the magnitude of the variable is unknown, always select a large measuring range before shifting down to lower ones. Make very sure that the voltage value between the measured contact and earth or between the ground socket and the measurement socket does not exceed 600. Before using the analogue multimeter to check that a voltage source is not exhibiting any actual voltage, check that the meter is working properly by selecting the battery test function. When measuring current, make sure the electricity is turned off before the analogue multimeter is connected into the circuit. When making measurements, always connect the ground lead first. Disconnect the signal measurement lead before unplugging the ground. Turn off the multimeter before opening the casing, disconnect the power to the circuit and the measuring leads from the multimeter. If measurements are made where there are any risks of coming into contact with electricity, a second person is to be informed. When the multimeter is used by teenagers, trainees etc., a suitable person should supervise to ensure the equipment is used safely. If measurements are to be made where voltages exceed 33 AC (RMS) or 70 DC, be especially careful and only use safety experiment leads. Measuring categories according to DIN EN 61010-1. CAT I or unstipulated: Approved for measurements in circuits which are not directly connected to the low voltage mains grid (e.g. batteries). CAT II: Approved for measurements in circuits which are directly connected, by a mains lead and plug for instance, to the low voltage mains grid (e.g. household or office appliance and lab equipment). CAT III: Approved for measurements in circuits which are part of a building s wiring installation (e.g. stationary consumers, distribution terminals, appliances connected directly to the distribution box). CAT I: Approved for measurements in circuits which are directly connected to the source of the low voltage mains (e.g. electricity meters, main service feed, primary excess voltage protection). 2

Display: Scales: Scale length: Pointer deflection: Electrical zero-point offset: Measurements: 0 10, linear 0 3, linear 80 mm 0 90 in all DC ranges oltage ranges: 0.1/ 0.3/ 1/ 3/ 10/ 30/ 100/ 300/ 600 AC/DC Current ranges: 0.1/ 0.3/ 1/ 3/ 10/ 30/ 100/ 300 ma AC/DC 1/ 3/ 10 A AC/DC Input resistance: oltage drop when measuring current: Reference conditions: Ambient temperature: 23 C Operating alignment: Signal form: Peak factor: 2 Frequency range: 1 MΩ AC/DC 100 m approx. AC/DC ertical/horizontal Sine (1% max. discrepancy) 40 Hz 50 Hz 5 khz Accuracy (at reference conditions): DC quantities: Class 2 DC with zero-point offset: Class 5 AC quantities: Class 3 Extended frequency range (class 10): 0,3 600 : 40 Hz 50 Hz 40 khz 3 3000 ma: 40 Hz 50 Hz 40 khz 10 A: 40 Hz 50 Hz 40 khz Resistance, conductance, impedance, admittance These quantities can be determined by forming various quotients involving simultaneous measurements of current and voltage. R = U / I: below 1 mω above 10 MΩ S = I / U: below 1 µs above 30 S Z = U / I: below 1 mω above 10 MΩ, 40 Hz 40 khz Y = I / U: below 1 µs above 30 S, 40 Hz 40 khz 3. Technical data Overload protection: oltage ranges: Current ranges: Electrical safety: 600 long-term in all voltage ranges 10 A of long-term loading in 3-A and 10-A ranges Safety specifications: EN 61010-1 Measuring category: CAT III: 600 Contamination level: 2 Protection type: Connectors: Protection: Fuses: Breaking capacity: IP20 4-mm safety sockets 2x FF 10 A/600 (10 x 38 mm) at least 10 ka 3B order number: 5008564 Power supply: Battery: 1x 1.5, AA IEC LR6 Automatic cut-off after: 45 min ± 10 min Electromagnetic compatibility: Interference emission: EN 55011:2009 Interference resistance: EN 61326-1:2013 Operating conditions: Ambient temperature: 5 C... 23 C 40 C Storage temperature: -20 70 C Relative humidity: General data: Shock test: Dimensions: Weight: <85% with no condensation max. 147 m/s² 100x150x50 mm 3 approx. 300 g approx. 3

CAT III 4. Symbol legend Hazard, read instruction sheet Moving coil galvanometer Apparatus with electronic amplifier DC quantities accuracy class 2 AC quantities accuracy class 3 Use in vertical position Use in horizontal position Dial position when turned off Dial position for battery test when battery charge is satisfactory Ground symbol Measuring category III Earth symbol Meter on for measurements with centre zero point Meter on for DC measurements Meter on for AC measurements Meter switched off Battery test Continuity test EU conformity mark Electrical safety assured by double insulation Do not dispose in normal domestic waste For use indoors only 5. Initial calibration Set up the ESCOLA 100 meter either horizontally or vertically. Do not connect measuring leads to begin with. Set the four-way switch to or. The needle will point to the zero point of the dial. If it does not, the amount of charge of the battery should be checked. 6.1 To switch on: 6. Operation Set the four-way switch to, or. 6.2 Checking battery charge: Set the four-way switch to Disconnect all measuring leads. Set the rotary switch to. If the battery is sufficiently charged, the needle will point to the following range indication,. If this is not the case, the battery will need to be replaced immediately. 6.3 Zero point calibration: Set up the analogue multimeter either horizontally or vertically. Set the four-way switch to. Turn the rotary switch to 600. Connect the common/ground socket and the voltage measurement socket together by means of a short connecting lead. Turn the zero-point trimmer screw to adjust the zero point as needed. 6.4 Zero point calibration for centre zero point: For measurements of DC current and voltage, the zero point of the scale can be moved to the centre of the dial. Disconnect all measuring leads. Set the four-way switch to and turn the rotary switch to a DC current or voltage range, Use the zero-point trimmer to line up the needle precisely in the centre of the dial. 6.5 To switch off: Set the four-way switch to. When the meter is turned off, the needle points to. 6.6 If a measurement is interrupted by battery cut-out: After 45 minutes of use, the multimeter is automatically shut off and the needle will then point to. To switch back on: Set the four-way switch of the analogue multimeter to off and then use it to turn the meter back on. 4

7. Current measurements up to 3 A The ESCOLA 100 may NOT be used to measure circuits connected directly to low-voltage mains sources. See page 2 of Measurement categories as specified in DIN EN 61010-1. The nominal voltage of the current source may not exceed 600. The multimeter is to be connected in series with the load on the side where the voltage with respect to ground is lowest! Turn off the circuit before the Escola 100 meter is connected into it. 8. Current measurements up to 10 A The ESCOLA 100 may NOT be used to measure circuits connected directly to low-voltage mains sources. See page 2 of Measurement categories as specified in DIN EN 61010-1. The nominal voltage of the current source may not exceed 600. The multimeter is to be connected in series with the load on the side where the voltage with respect to ground is lowest! Turn off the circuit before the Escola 100 meter is connected into it. CAT III 600 CAT III 600 If measurements are made when the magnitude of the variable is unknown, always select a large measuring range before shifting down to lower ones. Connect the terminal at the lower potential to the common/ground socket. Connect the common/ground lead first and only then the signal lead. 7.1 DC currents up to 3 A: Set the four-way switch to. Alternatively, if measurements are to be made with the zero point in the centre, then set the four-way switch to. Select the required current measuring range to a range measured in ma or A. Set up a measuring range of 10 A. Connect the terminal at the lower potential to the common/ground socket. Connect the common/ground lead first and only then the signal lead. 8.1 DC currents up to 10 A: Set the four-way switch to. Alternatively, if measurements are to be made with the zero point in the centre, then set the four-way switch to. 8.2 AC currents up to 10 A: Set the four-way switch to. 7.2 AC currents up to 3 A: Set the four-way switch to. Select the required current measuring range to a range measured in ma or A. 5

9. oltage measurements The ESCOLA 100 may NOT be used to measure directly at low-voltage mains sources. See page 2 of Measurement categories as specified in DIN EN 61010-1. The nominal voltage of the voltage source may not exceed 600. CAT III 600 11. Measuring current and voltage together The ESCOLA 100 may NOT be used to measure circuits connected directly to low-voltage mains sources. See page 2 of Measurement categories as specified in DIN EN 61010-1. The nominal voltage of the current source may not exceed 600. The multimeter is to be connected in series with the load on the side where the voltage with respect to ground is lowest! Turn off the circuit before the Escola 100 meter is connected into it. If measurements are made when the magnitude of the variable is unknown, always select a large measuring range before shifting down to lower ones. Connect the common/ground lead first and only then the signal lead. For measurements of voltage up to 100 m, set the rotary switch to the range 0.1 ma/100 m. CAT III 600 9.1 DC voltages up to 600 : Set the four-way switch to. Alternatively, if measurements are to be made with the zero point in the centre, then set the four-way switch to. Select the required measuring range to a range measured in. 9.2 AC voltages up to 600 : Set the four-way switch to. Select the required measuring range to a range measured in. 10. Continuity testing 11.1 DC voltages and currents: Set the four-way switch to. Use the rotary switch to set the desired voltage measuring range and read off the measurement. Set a suitable current measuring range and read off the measurement. 11.2 AC voltages and currents: Set the four-way switch to. Use the rotary switch to set the desired voltage measuring range and read off the measurement. Set a suitable current measuring range and read off the measurement. CAT III 600 Connect up the component to be tested. Set the four-way switch to and turn the rotary switch to. If there is continuity of current (R < 1 kω), an audible signal will sound. 6

12. Battery and fuses The battery and the two fuses are located underneath the back cover of the meter. One fuse each is provided for the 3 A and 10 A sockets: FF10 A/600, breaking capacity: at least 10 ka (3B order number: 5008564) The polarity is indicated by plus and minus signs inside the fuse holder compartment. A mechanical system ensures the battery makes no contact if it is inserted the wrong way round. 12.1 Battery testing: Check the amount of charge left in the battery from time to time. Flat or leaking batteries should be removed from the meter. If the Escola 100 goes unused for a long period: Remove the Escola 100 s battery before reusing. 12.2 Changing the battery: Before opening the casing: Turn off the Escola 100. Disconnect all measuring leads. Unscrew the back of the casing. Replace flat batteries with 1.5- alkaline batteries of size AA IEC LR6. Place the negative pole of the battery on the spring. Close the casing again. 13. Cleaning For cleaning, use a soft cloth, slightly mois-tened with alcohol, or a brush. Electrostatic charging of the display window can affect the measurements under certain circumstances: To remove such charge, use a soft cloth slightly soaked in alcohol or a paint brush. Dirt or moisture in the measurement sockets can affect readings. Shake out any dirt that may be in the measurement sockets. Soak a new swab with isopropyl alcohol and work around the inside of each measurement socket. 14. Disposal The packaging should be disposed of at local recycling points. Should you need to dispose of the equipment itself, never throw it away in normal domestic waste. If being used in private households it can be disposed of at the local public waste disposal authority. Comply with the applicable regulations for the disposal of electrical equipment. Do not dispose of the batteries in the regular household garbage. Follow the applicable legal regulations (UK: Waste Batteries and Accumulators Regulations, EU: 2006/66/EC). 12.3 Changing fuses: Before opening the casing: Turn off the Escola 100. Disconnect all measuring leads. Unscrew the back of the casing. Check the fuses. Blown fuses should be replaced with ones of the same rating. Close the casing again. 3B Scientific GmbH Rudorffweg 8 21031 Hamburg Germany www.3bscientific.com Subject to technical amendments Copyright 2015 3B Scientific GmbH