U ACTIVE SAT DISTRIBUTION FIELD

Similar documents
Always there to help you. Register your product and get support at AJ7045D. Question? Contact Philips.

Digital Function Generator

Always there to help you. Register your product and get support at AJ3400/79. Question? Contact Philips.

E-400 endstufe. user manual

Panther. Installation instructions. Receivers PN-R15-1 PN-R15-2 PN-R15-13 PN-R IM-PN-RX103-A03-EN Language: English (original)

Always there to help you. Register your product and get support at AJ3200. Question? Contact Philips.

APA3-1500R STARTER SET WIRELESS SWITCHING

Always there to help you. Register your product and get support at AJ5305D_12. Question? Contact Philips.

User Guide. Wideband 4-channel Auto Gain-Control Antenna Divider

Model 7000 Low Noise Differential Preamplifier

DPAfour125, DPAfour250 AMPLIFIERS. Operating Manual

Always there to help you. Register your product and get support at AJ5305D/05. Question? Contact Philips.

Always there to help you. Register your product and get support at AE2430. User manual

Antenna Splitter ASA 1. Instruction manual

E-800 power amplifier. user manual

Safety instructions and installation

Electrical devices may only be mounted and connected by electrically skilled persons.

Always there to help you. Register your product and get support at AJ3400. Question? Contact Philips.

Important Safety Information

SA 125 mixer amplifier. user manual

E-800 power amplifier. user manual

REIMESCH KOMMUNIKATIONSSYSTEME GMBH ALPIN HF / 50MHz Linear Amplifier - USER MANUAL. v1.1

Always there to help you. Register your product and get support at AJB4300. Question? Contact Philips.

AC 3. Active Antenna Combiner. Instruction manual

REIMESCH KOMMUNIKATIONSSYSTEME GMBH ALPIN HF Linear Amplifier - USER MANUAL. v1.0

Always there to help you. Register your product and get support at AJ3200. Question? Contact Philips.

D3400 digital power amplifier. user manual

3B SCIENTIFIC PHYSICS

PHOENIX CONTACT - 09/2009


Operating Instructions PROFITEST H+E TECH. Diagnostics Unit for Electric Charging Stations (Type 2 Connector Socket and Plug) /3.

TA 450 MK-X TA 600 MK-X TA 1050 MK-X TA 1400 MK-X TA 2400 MK-X power amplifier. user manual

ZM 84 Audio Mixer. User Manual. Order code: CRAM41. Audio Mixer ZM 84 AUX 3 AUX 1 AUX 2 AUX 4 MASTER 1 MASTER 2 OFF BASS BASS TREBLE TREBLE BASS BASS

Important safety instructions

SPA2060, SPA2120, SPA2240 amplifier. User Manual

Wireless Receiver E28Q Mounting and Operating Instructions (Original operating instructions)

E-400 power amplifier. user manual

User manual. Register your product and get support at Clock Radio Radio-réveil AJB3000

Active Transmitter Combiner 8:1 AC 3200-II. Instruction manual

Always there to help you. Register your product and get support at AJ3232. Question? Contact Philips.

free solo PT UHF wireless system user manual

Always there to help you. Register your product and get support at AJ2000. Question? Contact Philips.

Lanen True Diversity UHF Systems For electric and bass guitars: GB21 For Series 21 mics: UHF21. User Manual GB21 receiver/uhf21 transmitter

Copyright X02827C00 - Ed. 1-04/16

DIGITAL RADIO INCLUDING FM, DAB AND DAB+

Panther. Installation instructions. Receivers PN-RX-MN5 (PN-R8-1) PN-RX-MN5E (PN-R8-10) PN-RX-MD11 (PN-R8-6) PN-RX-MD11E (PN-R8-11)

free solo HT UHF wireless system user manual

Portable Appliance Testers. OmegaPAT MI 2140 BetaPAT MI 2141 User Manual Ver Code No

Always there to help you. Register your product and get support at AJ4300. Question? Contact Philips.

MODEL 3810/2 Line Impedance Stabilization Network

M-300 Mono power amplifier User s guide

ISOMETER IRDH575. Approvals

Register your product and get support at AE5430. EN User manual

free solo HT 1.8 GHz UHF wireless system user manual

COM-POWER OPERATION MANUAL ACS W

SECULIFE SR PC Controllable Instrument for Measuring Safety-Relevant Characteristic Values of Electrical Devices /2.

Always there to help you. Register your product and get support at OR7200. Question? Contact Philips.

Block-800B bass head. user manual

User Manual CXE Rev.002 Broadband Cable Networks March 3, (10) CXX Series. User Manual. Teleste Corporation CXE880.

SPLIT.CONVERTER. User's Manual. Version 2.0

Instruction Manual ICM 3091N Digital AC Clampmeter EN FR IT DE ES

MDC4500-4B Amplifier/Combiner Data Sheet & User Manual. February Rev 0.95

Thank you for purchasing a qualiton A20i power amplifier!

IEM 200 R UHF receiver. user manual

3B SCIENTIFIC PHYSICS

PHOENIX CONTACT

MHz FUNCTION GENERATOR INSTRUCTION MANUAL

RCR-24 中文 GB. Version 1

E4-130, E4-250 power amplifier. user manual

TSA 4-700, TSA 1400, TSA 2200, TSA 4000, TSA 4-300, TSA power amplifier. user manual

Operating Instruction

PRODUCT LEAFLET AUGIER-BOX. Remote Monitoring Unit for Street Lighting /07/2011

DEUTSCH ITALANIO ENGLISH NORSK FRANÇAIS DANSK NEDERLANDS Hersteller UR8200

INSTRUCTION MANUAL. Power Factor Controller - 12 steps Model A12 NOKIAN CAPACITORS. Power Factor Controller A12

1 Safety instructions. 2 Device components. Radio bus system. Radio socket outlet adapter for dimming Order No. : Operating instructions

RIGOL. User s Guide. RP5600 Passive Probe. July 2010 RIGOL Technologies, Inc.

free solo HT UHF wireless system user manual

LMM31. Dimmer Micromodule, 1 load USER MANUAL 20410/ LMM31 ALL RIGHTS RESERVED MARMITEK

free solo PT UHF wireless system user manual

Operator s Manual. PP016 Passive Probe

Important Safety Instructions ENGLISH - PAGES ESPAÑOL - PAGINAS FRANÇAIS - PAGES ITALIANO - PAGINE...

w w w. p r o l i g h t. c o. u k

TMP40. User Manual.

INSTRUCTION MANUAL. IBRit - rf1 - usb PC - Station for wireless Data transmission. M e s s t e c h n i k. Messtechnik GmbH & Co.

mix 502, mix 802, mix 1202FX mixer user manual

REVAMP4120T Instruction manual

UR200SI / UR200WE ENGLISH

DC162 Digital Visualizer. User Manual. English - 1

Thank you for purchasing a qualiton A50i power amplifier!

Always there to help you. Register your product and get support at AJ3400/37. Question? Contact Philips.

R/C SMD Tweezers Multimeter Model RC200

PA 502 A active 2-wayfull-range-speaker. user manual

Radio System Strobe Wizard Plus Freemask

Radio bus system Radio-universal dimming actuator, 1-gang. 1 Safety instructions. 2 Device components. Order-No. : Operating instructions

S5-ADU. Front... 4 Rear... 4

User s Manual Current Probe. IM E 1st Edition. Yokogawa Electric Corporation

QUANTUM Qflash T2 / X2 OPERATING INSTRUCTIONS

400 MHz Passive High-Voltage Probe R&S RT-ZH

TWS 16 BT UHF wireless system. user manual

PHOTO FRAME STRING LIGHTBOXES

Transcription:

U 911... 946 ACTIVE SAT DISTRIBUTION FIELD

Illustrations front view U 911 Controller port Indicator lamps Remote feed ON/OFF Labeling field Measurement points outputs Y outputs X input Y input X Bus port Mains supply connections Grounding terminal rear view U 911 2

Contents 1 Safety information Important: Hazard warnings and safety information.............. Page 3 U 911 illustration.............................. Page 2 1 Pictograms.................................. Page 3 2 Hazard warnings and safety information........... Page 3 2.1 Installation information...................... Page 3 2.2 Opening the housing....................... Page 4 2.3 Equipotential bonding / grounding............. Page 4 3 Different type designations...................... Page 5 4 Programming with the KC 3..................... Page 5 4.1 Fundamentals / device password............. Page 5 4.2 Setting the bus address..................... Page 6 4.3 Programming the SAT inputs................. Page 6 4.4 Monitoring the remote powering / alarms....... Page 6 5 Programming with the HE programming software.... Page 7 5.1 Inserting the SAT distribution field in a project... Page 7 5.2 Programming the SAT inputs................. Page 8 6 Indicator lamps............................... Page 9 7 Technical data...............................page 10/11 1 Pictograms and safety information Pictograms are symbols which have a defined meaning. You will encounter the following pictograms in these operating and installation instructions: This symbol is used to warn about situations in which there is a risk of fatal injury due to dangerous electrical voltages or as a result of failure to comply with these instructions. This symbol is used to warn about various risks to health, equipment/materials or the environment. This symbol is used to indicate general information. Recycling symbol: all of our packaging materials (cardboard packaging, package inserts, plastic film and plastic bags) can be fully recycled. Electronic equipment is not household waste in accordance with directive 2002/96/EC OF THE EUROPEAN PARLIAMENT AND THE COUNCIL of 27 th January 2003 on used electrical and electronic equipment, it must be disposed of properly. At the end of its service life, take this unit for disposal at a relevant official collection point. 2 Hazard warnings and safety information 2.1 Installation information The device must only be installed in a dry room. Assembly location: indoor room 3

2 Hazard warnings and safety information 2 Hazard warnings and safety information The device must not be exposed to splashing or dripping water. Objects filled with a liquid must not be placed on the device. In the event of condensation, wait until the device is completely dry. The permissible ambient temperature range is 0 50 C. The equipment must only be installed in rooms in which it is ensured that the required ambient temperature conditions are met even under fluctuating climatic conditions. Warning: Please pay special attention to ensuring that the ambient temperature requirements are met if the unit is installed in a loft or attic space. 2.2 Opening the housing Important please note the following before opening the device: Disconnect the mains plug. (Take care when working on the power supply unit. Some components may still carry a voltage after disconnection from the mains and could cause an electrical shock if touched.) The power cord(s) must only be replaced by equivalent genuine ASTRO replacement power cord(s). Fuses must only be replaced with replacement fuses of the same type and with the same ratings and melting characteristics. Important: Compliance must be ensured with: DIN VDE 0701 parts 1 and 200, servicing EN 50 083 part 1, safety requirements 2.3 Equipotential bonding / grounding The device must be properly grounded and installed in accordance with EN 50 083 part 1. The requirements laid out in EN 50083 part 1 and the national legislation relating to IT/TT power supply networks must be complied with Operation of the device without a protective ground connection, proper grounding of the device or equipotential bonding is not permitted. Never perform any service repairs during a thunderstorm. The housing must only be opened by an authorized specialist who has been certified by the Chamber of Commerce and Industry (master workshop). The device must only be repaired by an authorized specialist who has been certified by the Chamber of Commerce and Industry (master workshop), or alternatively by sending it back to ASTRO together with a detailed description of the fault. 4

3 Type designations 4 Programming with the KC 3 3 Different type designations Input impedance: 75 Ω Output impedance: 75 Ω U911 2 x 1 in 8 with two power supply units U912 2 x 1 in 8 with one power supply unit U913 2 x 1 in 8 with no power supply unit U914 1 x 1 in 16 with two power supply units U915 1 x 1 in 16 with one power supply unit U916 1 x 1 in 16 with no power supply unit Input impedance: 50 Ω Output impedance: 50 Ω U 921 2 x 1 in 8 with two power supply units U 922 2 x 1 in 8 with one power supply unit U 923 2 x 1 in 8 with no power supply unit U 924 1 x 1 in 16 with two power supply units U 925 1 x 1 in 16 with one power supply unit U 926 1 x 1 in 16 with no power supply unit Input impedance: 50 Ω Output impedance: 75 Ω U 931 2 x 1 in 8 with two power supply units U 932 2 x 1 in 8 with one power supply unit U 933 2 x 1 in 8 with no power supply unit U 934 1 x 1 in 16 with two power supply units U 935 1 x 1 in 16 with one power supply unit U 936 1 x 1 in 16 with no power supply unit Input impedance: 75 Ω Output impedance: 50 Ω U 941 2 x 1 in 8 with two power supply units U 942 2 x 1 in 8 with one power supply unit U 943 2 x 1 in 8 with no power supply unit U 944 1 x 1 in 16 with two power supply units U 945 1 x 1 in 16with one power supply unit U 946 1 x 1 in 16 with no power supply unit The different variants may vary slightly from the descriptions provided in the operating instructions in terms of their operation. Other special types available on request. 4. Programming the SAT distribution field with the KC 3 4.1 Fundamentals After plugging in the KC 3 programming device the Start menu will initially appear. The software version number is displayed.. Please quote this number whenever contacting our customer service department. The Start menu can only be accessed again later on by unplugging and replugging the KC 3. After plugging in the KC 3, you can press the Menu Read button first to view additional data for the device (no. of LNC inputs, redundant power supply unit yes/no). Here, you can use the and cursor keys to go to row four and access the menu for Setting up a device password: Use the or cursor keys to activate the password function. After pressing the OK Store button you will be asked to enter the new password. If the password function is active then it will not be possible to save changes without the password. Please contact the manufacturer if you cannot remember your password. 5

4 Programming with the KC 3 4 Programming with the KC 3 After plugging in the KC 3, you can use the or cursor keys to access the menu for adjusting the parameters of the SAT distribution field. The equalization can be activated or deactivated by pressing the or cursor keys. Here again you need to press OK Store to save the changed settings. 4.2 Setting the bus address After plugging in the KC 3, press the or cursor keys to access the menu for setting the bus address. Then press the or cursor keys to go to the third row of the menu, where you can use the or cursor keys to select a bus address value between 31 and 50. Then press OK Store to save the selected settings. The message Data saved will appear for about 1 second. 4.3 Programming the SAT inputs After plugging in the KC 3 and pressing the or cursor key twice you will go to the menu for setting the bus address and on to the menu for programming the X input of the SAT distribution field. You can then use the or cursor keys to go to the second row of the X input menu for Adjusting the attenuation with the or cursor keys in increments of 0.5 db. The attenuation can be set to a range from 0 to 16 db. Press the button OK Store to save the changes made. The message Data saved will appear for about 1 second. If you press the button Menu read in the second row as well then this will take you to the menu for 4.4 Monitoring of the remote powering / alarms The remote powering which can be activated on the front panel of the device and can also be monitored: Use the or cursor keys to go to the third row of the X input menu, where you can change all settings for monitoring the remote powering and for the alarms which are triggered when certain values drop below their alarm thresholds. The current remote feed current is displayed here initially. Pressing the Menu Read button will take you to the activation and deactivation of the alarms, which is set with the aid of the or cursor keys. Press the Menu Read button again and use the or cursor keys to adjust the lower alarm threshold in 50 ma increments (from 50 ma to 250 ma). The upper alarm threshold is adjusted in similar fashion after pressing the Menu Read button (range from 100 ma to 350 ma). The fourth row of the X input" menu shows the current temperature of the device. All of the information for the X input menu applies analogously to the Y input" menu. Activating the 7 db slope equalization: 6

5 Programming with the HE programming software 5 Programming with the HE programming software 5. Programming the SAT distribution field with the HE programming software 5.1 Inserting the SAT distribution field into a project One or more SAT distribution fields can be inserted under Planning Project Data in the HE programming software. After entering the SAT distribution field it can be called up in the HE programming software under SAT-ZF predistribution. 7

5 Programming with the HE programming software 5 Programming with the HE programming software 5.2 Programming the SAT inputs Any of the satellites stored in the database can be assigned to the SAT inputs. The next step is to select the polarization and the band. In addition, the 7 db slope equalization and the monitoring of the LNC remote feed can also be activated or deactivated via the software. Values between 100 ma and 700 ma are available for the lower threshold, with values between 200 ma and 800 ma available for the upper threshold (in increments of 50 ma). The attenuation of the SAT distribution field can also be adjusted via the HE programming software. The adjustment range is 0 to 16 db, with increments of 0.5 db. 8

5 Programming with the HE programming software 6 Indicator lamps 6. Indicator lamps The green LED on the front panel of the device indicates that the power supply unit is operating without any faults. A green LED is also used to indicate if the LNC remote feed is activated. If the monitoring of the LNC remote feed is activated and the current reading moves outside the previously specified window then this is signaled with a red LED. The current remote feed current is displayed after the SAT distribution field has been read out. Read it out again to update the display. All operating information for the X-input applies analogously to the Y-input. 9

7 Technical data Type U-911 U-912 U-913 U-914 U-915 U-916 U-921 U-922 U-923 U-924 U-925 U-926 Order no. 380 192 380 212 380 213 380 214 380 215 380 216 380 221 380 222 380 223 380 224 380 225 380 226 Inputs / outputs 2x 1 in 8 1x 1 in 16 2x 1 in 8 1x 1 in 16 No. of power supply units 230V / 28VA 2 1 0 2 1 0 2 1 0 2 1 0 Remote feed current [ma] 350 350 1500* 350 350 1500* 350 350 1500* 350 350 1500* LNC feed voltage [V] 16 16 15 18 16 16 15 18 16 16 15 18 16 16 15 18 (F sockets) [Ω] 75 / 75 Inputs /outputs (SMA connectors) [Ω] 50 / 50 Input frequency range [MHz] 950 2150 Nominal input level [dbµv] 85 Transmission loss [db] 0 ±2 Level decoupling [db] > 40 Level adjuster (0.5 db increments) [db] 0-15 Slope equalization [db] 0/7 ±1 Freq. response, insertion attenuation in 36 MHz bandwidth [dbss] < 1 in nominal frequency range [dbss] < 2 Active return loss Inputs/outputs [db] 12 / 14 Output decoupling [db] > 20 Measuring outputs (1 per level) Nominal decoupling attenuation [db] -10 Active return loss [db] 15 * max. 1.5 A, depending on the feed network proportion and the internal fuses. 10

7 Technical data Type U-931 U-932 U-933 U-934 U-935 U-936 U-941 U-942 U-943 U-944 U-945 U-946 Order no. 380 231 380 232 380 233 380 234 380 235 380 236 380 241 380 242 380 243 380 244 380 245 380 246 Inputs / outputs 2x 1 in 8 1x 1 in 16 2x 1 in 8 1x 1 in 16 No. of power supply units 230V / 28VA 2 1 0 2 1 0 2 1 0 2 1 0 Remote feed current [ma] 350 350 1500* 350 350 1500* 350 350 1500* 350 350 1500* LNC feed voltage [V] 16 16 15 18 16 16 15 18 16 16 15 18 16 16 15 18 (F sockets) [Ω] / 75 75 / Inputs /outputs (SMA connectors) [Ω] 50 / / 50 Input frequency range [MHz] 950 2150 Nominal input level [dbµv] 85 Transmission loss [db] 0 ±2 Level decoupling [db] > 40 Level adjuster (0.5 db increments) [db] 0-15 Slope equalization [db] 0/7 ±1 Freq. response, insertion attenuation 36 MHz bandwidth [dbss] < 1 in nominal frequency range [dbss] < 2 Active return loss Inputs/outputs [db] 12 / 14 Output decoupling [db] > 20 Measuring outputs (1 per level) Nominal decoupling attenuation [db] -10 Active return loss [db] 15 * max. 1.5 A, depending on the feed network proportion and the internal fuses. 11

ASTRO Strobel Kommunikationssysteme GmbH Olefant 1 3 D-51427 Bergisch Gladbach (Bensberg) Tel. 0 22 04 / 405-0 Fax 0 22 04 / 405 10 http://www.astro-kom.de 82 270400 10/ 2006 GB