High Field Electrical Conduction and Breakdown in Solid Dielectrics

Similar documents
Measurement Of Partial Discharge (PD) In High Voltage Power Equipment

Partial Discharge Analysis of a Solid Dielectric Using MATLAB Simulink

PARTIAL DISCHARGE MEASUREMENT ANALYSIS ON RING MAIN UNIT

Simulation of Partial Discharge in High Voltage Power Equipment

Simulation Model of Partial Discharge in Power Equipment

[Mathur* et al., 5(6): June, 2016] ISSN: IC Value: 3.00 Impact Factor: 4.116

International Journal of Advance Engineering and Research Development. Comparison of Partial Discharge Detection Techniques of Transformer

Partial Discharge Patterns in High Voltage Insulation

Condition Assessment of High Voltage Insulation in Power System Equipment. R.E. James and Q. Su. The Institution of Engineering and Technology

Basics of Partial Discharge. Prepared for 2015 Phenix RSM Meeting January 2015

PARTIAL DISCHARGE MEASUREMENT AS A DIAGNOSTIC TOOL FOR CURRENT TRANSFORMER

CHAPTER 5 CONCEPT OF PD SIGNAL AND PRPD PATTERN

Detection of Partial Discharges and its Effect on Solid Insulation used in High Voltage Cable

PARTIAL DISCHARGE DETECTION - AN OVERVIEW

The Effect of Practical Voltages on Maximum Amplitude of Partial Discharge with Considering Different Number of Cavities

Partial Discharge Classification Using Novel Parameters and a Combined PCA and MLP Technique

Dielectric Behavior of Insulating Material Under Transformer Oil

CONDITION MONITORING OF MEDIUM VOLTAGE ELECTRICAL CABLES BY MEANS OF PARTIAL DISCHARGE MEASUREMENTS

REVIEW: PARTIAL DISCHARGE TEST FOR INSULATOR

PATTERN CLASSIFICATION OF PARTIAL DISCHARGE IN LV WINDING OF 1- TRANSFORMER USING PCA

CHAPTER 2. v-t CHARACTERISTICS FOR STANDARD IMPULSE VOLTAGES

THE PROPAGATION OF PARTIAL DISCHARGE PULSES IN A HIGH VOLTAGE CABLE

Testing and PD Diagnosis of MV Cable Systems with DAC Voltage Educational Session May St Pete Beach, Fl

Partial Discharge Theory, Modeling and Applications To Electrical Machines

1409. Comparison study between acoustic and optical sensors for acoustic wave

High Frequency Voltage Stress. Presented by: Flore Chiang Date: March 30, 2012

Electric Field Analysis of High Voltage Condenser Bushing

FAULT IDENTIFICATION IN TRANSFORMER WINDING

Fault Detection in Transformer Using Frequency (Sweep) Response Analysis

THE POWER OF LIFE. WinTech Partial Discharge based Predictive Intelligence of insulation system to eliminate power failure risk.

AC CREEPAGE DISCHARGES IN SF 6, CO 2, N 2 AND SF 6 -CO 2 AND SF 6 - N 2 MIXTURES

MODELING OF PARTIAL DISCHARGE IN TRANSFORMER WINDINGS AND ITS DETECTION

Influence of Impurity Concentration on Insulation Strength of Insulating Oil under Different Voltage Types

High-Voltage Test Techniques

Study of Insulation Under Varying Field Conditions

LESSON PLAN LP-EE Sub Code: EE 2353 Sub Name: HIGH VOLTAGE ENGINEERING Unit: I Branch: EEE Semester: VI

WAVELET DE-NOISING AND ANALYSIS OF UHF PARTIAL DISCHARGES IN HIGH VOLTAGE POWER TRANSFORMER

Extended analysis versus frequency of partial discharges phenomena, in support of quality assessment of insulating systems

The University of New South Wales. School of Electrical Engineering and Telecommunications. High Voltage Systems ELEC9712. Appendix Partial Discharge

Frequency Spectrum Analysis of Electromagnetic Waves Radiated by

PD Diagnostic Applications and TechImp solutions

Multi-Resolution Wavelet Analysis for Chopped Impulse Voltage Measurements

Why partial discharge testing makes good sense

Partial Discharge Detection For Condition Monitoring Of An 11-kV XLPE Cable-Part II

GUJARAT TECHNOLOGICAL UNIVERSITY

Characteristics of Insulation Diagnosis and Failure in Gas Turbine Generator Stator Windings

Investigation of Inter-turn Fault in Transformer Winding under Impulse Excitation

Partial Discharge Monitoring and Diagnosis of Power Generator

Digital Signal Processing for the Detection and Location of Acoustic and Electric Signals from Partial Discharges

Africa Utility Week Focus Day Substation Condition Monitoring Benefits of Ultrasound

Calculation of Transients at Different Distances in a Single Phase 220KV Gas insulated Substation

TECHIMP Technologies & Services for Diagnostics and Monitoring of High Voltage Assets

Non-intrusive Measurement of Partial Discharge and its Extraction Using Short Time Fourier Transform

Investigation of PD Detection on XLPE Cables

Abstract. 1 Introduction

High-Voltage Test and

Gas-Insulated Metal-Clad Switchgears Express-Diagnostics Method on Partial Discharge Characteristics

LEVEL DEPENDENT WAVELET SELECTION FOR DENOISING OF PARTIAL DISCHARGE SIGNALS SIMULATED BY DEP AND DOP MODELS

A Reflectometer for Cable Fault Location with Multiple Pulse Reflection Method

Partial Discharge Classification Using Acoustic Signals and Artificial Neural Networks

ROEVER ENGINEERING COLLEGE ELAMBALUR, PERAMBALUR DEPARTMENT OF ELECTRICAL & ELECTRONICS ENGINEERING

High Frequency Modeling of Two Limb Series Loop Winding for Partial Discharge Localization

Harmonic Components Analysis of Leakage Current for Standard and Anti-Fog Suspension Insulators under Humidity Conditions

Coherence and time-frequency analysis of impulse voltage and current measurements

Generation of Sub-nanosecond Pulses

Evaluation and Limitations of Corona Discharge Measurements An Application Point of View

Partial discharge diagnostics on very long and branched cable circuits

PARTIAL DISCHARGE MEASUREMENT

Visualization of the Ionization Phenomenon in Porous Materials under Lightning Impulse

EFFECT OF INTEGRATION ERROR ON PARTIAL DISCHARGE MEASUREMENTS ON CAST RESIN TRANSFORMERS. C. Ceretta, R. Gobbo, G. Pesavento

Design and construction of double-blumlein HV pulse power supply

DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING QUESTION BANK SUBJECT CODE & NAME : EE 1402 HIGH VOLTAGE ENGINEERING UNIT I

PARTIAL DISCHARGE MEASUREMENT ON ROTATING MACHINES

Prognostic Modeling for Electrical Treeing in Solid Insulation using Pulse Sequence Analysis

Comprehensive modeling of Dry type foil winding transformer to analyse inter turn insulation under Lightning Impulse Voltage

The importance of partial discharge testing throughout the development and operation of power transformers

Software System for Finding the Incipient Faults in Power Transformers

Study on Glow Discharge Plasma Used in Polyester. surface modification

Life Prediction of Mold Transformer for Urban Rail

TECHIMP Power Transformer Monitoring

NEW MV CABLE ACCESSORY WITH EMBEDDED SENSOR TO CHECK PARTIAL DISCHARGE ACTIVITY

IEEE Transactions on Power Delivery. 15(2) P.467-P

Case Studies of Electric Power Equipment Diagnostics Using Acoustic Emission

HVDC Transmission. Michael Muhr. Institute of High Voltage Engineering and System Performance Graz University of Technology Austria P A S S I O N

Electric Stresses on Surge Arrester Insulation under Standard and

SF 6 Capacitive Voltage Divider

Design of Meander Antenna for UHF Partial Discharge Detection of Transformers

Siemens Transformer Technology Seminar Low Partial Discharge Transformers

PD Solutions. On-Line PD Measurement Devices

CHAPTER 1 INTRODUCTION

3.2 Measurement of high voltages

Research of Composite Insulator Detection Device Based on Electric Field Method and Resistance Method

Ultra Hight Voltge Transmission line Faults Identified and Analysis by using MATLAB Simulink

Analysis of MOV Surge Arrester Models by using Alternative Transient Program ATP/EMTP

Analysis of Partial Discharge Patterns for Generator Stator Windings

Diagnostic testing of cast resin transformers

A Neuro-Fuzzy Approach for the Detection of Partial Discharge

Analysis of Propagation Paths of Partial Discharge Acoustic Emission Signals

USING DAMPED AC VOLTAGES

Partial Discharge Inception and Propagation Characteristics of Magnet Wire for Inverter-fed Motor under Surge Voltage Application

Transcription:

High Field Electrical Conduction and Breakdown in Solid Dielectrics R.S.Pote 1, V.N.Gohokar 2, D.G.Wakde 3, R.S.Kankale 4 Associate Professor, Department of Electrical Engineering, SSGMCOE, Shegaon, India 1, Professor, Department of Electrical Engineering, All India Shri Shivaji Memorial College of Engineering, Pune, India 2, Director, P.R.Pote Patil College of Engineering, Amravati, India 3 Assistant Professor, Department of Electrical Engineering, SSGMCOE, Shegaon, India 4 ABSTRACT: Insulator is an important part of the high voltage equipments. Various types of insulating materials are used in high voltage electrical power system to protect all power system equipments. For the safety, reliability and efficiency, the insulating materials must be in a healthy condition during its operation. Most of the insulating materials are in impure form due to presence of air bubbles (cavity) or other impurities present inside the solid insulating materials. The local electrical breakdown occurring in solid dielectric is called as partial discharge (PD) which takes place due to the high voltage field stress. Due to the occurrence of PD the dielectric property of insulating materials deteriorates. Because of this reason detection of PD becomes one of the important tasks for high voltage engineers in order to keep the high voltage equipment in healthy condition. In this experimental model is used to study partial discharge and breakdown phenomena. For experimentation purpose sample of Acrylic material with cylindrical cavity is taken as a solid insulating material for creating partial discharge inside the solid dielectric by applying high voltage. In this study, partial discharge signal is captured with experimental setup at different high voltages which are further used for study and PD analysis. KEYWORDS: Insulators, Partial Discharge, High Voltage, Cavity. I. INTRODUCTION Partial Discharge occurs inside the cavities present in a solid dielectrics, or bubbles inside the liquid dielectrics [13]. Since the discharge is named as partial discharge so it is limited only in the cavity portion inside the insulation. Partial discharges partially bridge the gap between the two electrodes. Boundary between two insulating materials can also lead to the occurrence of partial discharge. Cavities or bubbles present in insulating medium contain gas inside it due to which partial discharge occurs in a medium [1]. Because the dielectric strength of the gas inside the cavity or bubble is less than the surrounding dielectric medium, the electric field stress acting across the cavity or bubble is considerably higher than that across the complete dielectric [12]. If the voltage applied across the cavity or bubble is raised above the corona inception voltage for the gas present inside it, then PD activity will initiate within the void. This PD causes deterioration and degradation of insulating materials, ultimately leading to reduction of dielectric strength or dielectric property this will lead to final breakdown and complete damage of dielectric materials. PD can be avoided by designing an insulation medium careful and by proper material selection. In high voltage equipment manufacturing industry the insulation system is tested to detect the presence of cavity by monitoring PD. Periodically equipment s are tested by using on- line partial discharge measurement devices for detection of PD. Prevention and detection of PD is necessary to insure reliable and long-term operation of high voltage equipment. Many errors occurs in power system equipments are related to failure of insulation system or partial discharge which deteriorate the dielectric strength, majority of the faults occurs due to insulation failure [16]. Detection and identification techniques of PD are essential for removing errors in insulation system of high voltage equipments. Researchers are working for detection and identification of partial discharges. Localization of PD can be done by proper modelling and simulating PD mechanism. In this paper detection and identification of PD is done. Copyright to IJAREEIE DOI:10.15662/IJAREEIE.2016.0508024 6758

II. PARTIAL DISCHARGE MECHANISM As per IEC Standard 60270, Partial discharge is defined as a localized electrical discharge that partially bridges the insulation gap between the two conductors and which may or may not occur adjacent to a conductor. Concentration of local electrical stress in an insulation system or on the surface of insulation system results in occurrence of partial discharge. Such electrical discharges appear in the form of sharp impulses of various forms of voltage magnitude and current magnitude having short duration less than a sec. Generally PD occurs in high voltage equipments like transformer, insulators, cable etc. PD mainly occurs within cavities or voids inside a solid dielectric. It also occurs at interface between solid and liquid dielectric mediums, or in bubbles or air pockets inside liquid dielectrics. This discharge is limited to only over a portion of the insulation; the discharge partially bridges the gap between the two electrodes. PD can also take place along the insulation boundary between two insulating materials. A. CLASSIFICATION OF PARTIAL DISCHARGE Partial discharge phenomenon is divided into following two categories: (a) External partial discharge The partial discharge which takes place outside the high voltage equipment is called as external partial discharge. Such type of discharge generally occurs in overhead transmission lines or on armature of machines. (b) Internal partial discharge The partial discharge which mainly occurs inside a system is called as internal partial discharge. The discharge occurring inside cavity is belonging to such type of partial discharge. Partial discharge includes several types of discharges like corona discharge, surface discharge, cavity discharge, Treeing and tracing phenomenon. (i) (ii) (iii) (iv) Surface discharge: It takes place on interfaces of two different dielectric materials such as gas and solid interface due to high electric stressed in gas than solid material. This type of discharge may takes place in high voltage bushing, high voltage cable end, on insulator surface between electrodes. Cavity discharge: Generally cavities are formed in solid or bubbles in liquid insulating materials. The cavity is filled with gas or air medium. Such discharge takes place when the gas within the cavity gets over stressed. Corona discharge: It takes place due to non-uniform electric field distribution on the edges of conductor supplied with high voltage. Gas or air or liquid insulation is supplied for such type of discharge. Treeing and tracing: High intensity electric fields are produced in an insulating material at its surfaces or edges which deteriorates the insulating material. This is responsible for the production of continuous discharge called as Treeing and tracking phenomenon. B. EFFECT OF A PARTIAL DISCHARGE IN INSULATING SYSTEM Occurrence of PD is the main cause for degradation of insulating material and responsible for electrical breakdown. Repetition of partial discharge phenomenon is the main reason for mechanical and chemical degradation or deterioration of the insulating material. The effect of this discharge is severe on insulation of high voltage power equipment. Insulation damage occurs due to formation of partial discharge. The conductivity of the insulating material is zero under normal operating condition but it rises due to chemical changes in the dielectric. Dielectrics are classified into two types: Inorganic dielectric and Organic dielectric. Generally immunity of organic dielectrics is less. Porcelain, glass, mica are belonging to inorganic type of dielectric. Polymer dielectrics are belonging to organic dielectrics category. Partial discharge generally produces energy in the form of heat. Heat energy is the main cause for degradation of the insulating medium. The effect is termed as thermal effect. For high voltage equipments deterioration of the insulation can be identified by monitoring the partial discharge activities. It can be monitored time to time by the high voltage engineer at the time of high voltage equipment manufacturing. Copyright to IJAREEIE DOI:10.15662/IJAREEIE.2016.0508024 6759

C. PD MEASURING CIRCUITS ACCORDING TO IEC 60270 Fig.1 shows the equivalent circuit diagram for the measurement of PD(partial discharge) as per IEC 60270. This setup consists of high voltage source, test object as per a-b-c model and measuring instrument. Fig: 1: Equivalent circuit diagram used for PD measurement There are various methods used for the measurement of partial discharge based on both electrical and non-electrical phenomena. Methods which have been popularly used for the measurement of partial discharges are: Optical method of detection Acoustic method of detection Chemical method of detection Electrical method of detection D. FACTORS AFFECTING THE DIELECTRIC STRENGTH OF INSULATING MATERIAL Several studies are carried out to check whether the dielectric strength of insulating material is affected by some factors or conditions. The dielectric strength of any insulating material depends upon the temperature, impurity; spacing between two electrodes etc. and some other factors which are also responsible for it. In high voltage equipments the strength of liquid dielectric decreases to 70 % because of the presence of impurity content like suspended particles. Impurity includes solid particles of carbon, wax, and fiber. Presence of impurity contents creates imperfections in the insulation system. III. NECESSITY OF DETECTION OF PARTIAL DISCHARGE Most of the dielectric materials are in impure form from the origin. Due to the presence of impurity air bubbles are created within the insulating material. It minimizes the insulation property and responsible for the occurrence of partial discharge. The reason behind the formation of PD is the dielectric constant of the gas inside the cavity is less than that of surrounding medium. This results in insulation failure of high voltage equipments. Partial discharge generally occurs in cavities. This type of electric discharge has low magnitude but they are responsible for degradation of insulation. Due to formation of discharge, failure occurs in the insulation medium. Because of all above reason detection and measurement partial discharge is important for predicting life of insulation in high voltage equipments. IV. MODELING OF CIRCUIT FOR PD MEASUREMENT The characteristics of internal discharges occurring inside the dielectric medium can be represented using most accepted a-b-c model. Fig.2.a represents the physical model of insulator with cavity inside it and fig.2.b represents a-bc model of insulator with cavity in the form of capacitors. The values of capacitors can be determined by using following formulae. Assuming that a cylindrical cavity is filled with a gas of relative permittivity c, the capacitance of portion c is given as C = A h The capacitance of portion b of relative permittivity i is given as Copyright to IJAREEIE DOI:10.15662/IJAREEIE.2016.0508024 6760

C = A h h Similarly, the capacitance for portion a can be determined. Fig. 2: a) physical representation of insulator with cavity & b) a-b-c model representation of insulator with cavity V. EXPERIMENTAL SETUP Fig.3 & Fig.4 shows overall experimental setup for detection and measurement of partial discharge. Fig.3 shows 100kV High voltage AC testing set, point-plane electrode arrangement, solid (Acrylic sheet of 100mmx100mmx5mm) dielectric sample with cylindrical cavity of 2mm diameter, discharge current sensor. By using HV control panel we can change the magnitude of high voltage applied to dielectric. With the help of meters mounted on HV panel we can monitor the magnitude of applied high voltage and leakage discharge current. Fig. 3: Point-Plane Electrode Sample with 5mm gap Copyright to IJAREEIE DOI:10.15662/IJAREEIE.2016.0508024 6761

Fig.4 shows Tektronix make TDS 2014B DSO, PC with Open Choice Desktop and Tekvisa software. Current sensor senses the changes in current which can be monitored on DSO as well as PC. This current signal is used to study the partial discharge occurring at different magnitude of applied voltage. Fig. 4: Experimental set for measurement and detection of Partial Discharge (PD) VI. RESULTS & DICUSSION Fig.5 shows the current signal captured with the help of experimental setup on TDS 2014B DSO. The partial discharges occurring due to presence of cavity in dielectric sample are represented in the form of spikes in current waveform. Single cycle of current signal is captured. Fig. 5: Current Signal with partial discharges captured on TDS 2014B DSO Fig. 6 shows the wavelet decomposition of the breakdown current signal processed in MATLAB environment upto decomposition level 6. The experimental results are obtained in statistical and graphical form for the study of partial discharge and breakdown characteristics formed in solid insulating material. From the experimental setup partial discharge and breakdown signal can be captured. It is observed that when high voltage is applied through the source to sample the amplitude of the partial discharges are detected in the solid insulator Acrylics in the form of sudden spikes Copyright to IJAREEIE DOI:10.15662/IJAREEIE.2016.0508024 6762

Fig.6: DWT apllied to the breakdown signal upto the level 6 Table 1 shows the statistical parameters by applying the db6 & sym6 wavelet for wavelet decomposition of captured signal at various levels.. Parameters For db6 At Level 6 For sym6 At Level 6 Mean -0.003473-0.003473 Median 0.0032 0.0032 Mean 0.004883 0.004883 Maximum 0.103 0.103 Minimum -0.1-0.1 Range 0.203 0.203 Standard Deviation 0.04538 0.04538 Median Abs. Dve. 0.032 0.032 Mean Abs. Dev. 0.0351 0.0351 L1 Norm. 85.44 85.44 L2 Norm. 2.275 2.275 Maximum Norm. 0.103 0.103 Table 1: Statistical Parameters of the captured breakdown waveform VII. CONCLUSION This paper addresses the phenomenon of partial discharge and breakdown occurring in high voltage equipment insulation system. While designing insulation system for high voltage equipment engineer has to pay attention on formation of cavity in dielectric. If any cavity is formed in the dielectric then detection of such cavity is necessary as it creates partial discharge and breakdown takes place. This partial discharge degrades the insulation. Hence, detection and measurement of partial discharge is done by monitoring discharges occurring in dielectric under service condition. It is necessary to keep all equipments in healthy working condition throughout their operation. The work presented in this paper is based on experimental studies carried out for partial discharge measurement and detection using discharge current sensor and 2014B TDS Tektronics make DSO. The amplitude and frequency of partial discharge occurrence can be easily measured from the captured waveform.the life of dielectric material can be predicted with the help of partial discharge signal captured. Copyright to IJAREEIE DOI:10.15662/IJAREEIE.2016.0508024 6763

REFERENCES [1] G. C. Crichton, P. W. Karlsson and A. Pedersen, Partial Discharges in Ellipsoidal and Spherical Voids, IEEE Trans. on Dielectric and Electrical Insulation, Vol. 24, No. 2, pp. 335-342, April 1989. [2] R. J. Van Brunt, Physics and Chemistry of partial discharges and corona, IEEE Trans. on dielectric and Electrical Insulation, Vol. 1, No. 5, pp. 761-784, October 1994. [3] A. Paithankar, A. D. Mokashi, Can PD Phenomena be Analyzed by Deterministic Chaos EIC 97, Chicago, (IEEE) Conference proceedings, pp. 283-290, 1997. [4] N. Kolev, P. Darjanov, E. Gadjeva and D. Darjanova, Partial Discharge Phenomena Simulation using General-purpose Analysis Program, Proc of 6th IEEE International Conference on Conduction and Breakdown in solid Dielectrics-ICSD 98, pp. 149-152, June 22-25, Vasteras, Sweden, 1998. [5] C. Y. Ren, Y. H. Cheng, P. Yan, Y. H. Sun, T. Shao, Simulation of Partial Discharges in Single and Double voids Using SIMULINK, Journal of Xi an Jiatong University, Vol. 38, No. 10, pp. 120-122, 2004. [6] N. Kolev, P. Darjanov, E. Gadjeva and D. Darjanova, An approach to develop a partial discharge investigation, Proc. of the IEEE Electrical Insulation Conference and Electrical Manufacturing and Coil Windings conference, pp. 507-510, Chicago, 1997. [7] L. Satish, and W. S. Zaengl, Artificial Neural Networks for recognition of 3D Partial Discharge patterns, IEEE Trans. on Dielectrics and Electrical Insulation, Vol. 1, No. 2, pp. 265-275, April 1994. [8] F. Gutleisch and L. Niemeyer, Measurement and Simulation of PD in Epoxy Voids, IEEE Transcation on Dielectrics and Electrical insulation, Vol. 2, No. 5, pp. 729-743, 1995. [9] R. Bartnikas, Partial Discharge their mechanism, Detection and Measurement, IEEE Trans. Electr. Insul. Vol. 9, pp. 763-808, 2002. [10] S. Karmakar, N. K. Roy, P. Kumbhakar, Partial Discharge Measurement of Transformer with ICT Facilities, Third International Conference on Power Systems, Kharagpur, India, December27-29, 2009. [11] S. Karmakar, N. K. Roy, P. Kumbhakar Monitoring of high voltage power transformer Using direct Optical Partial Discharges detection technique,journalofoptics,vol.38,no. 4, pp.207-215, 2009. [12] E. Kuffel, W. S. Zaengl, J. Kuffel, High Voltage Engineering: Fundamentals, Published by Elsevier, ISBN 0-7506-3634-3, second edition, 2005. [13] M. S. Naidu and V. Kamaraju, High Voltage Engineering, New Delhi, Tata McGraw-Hill, pp. 69-85, 2004. [14] Mu Kuen Chen and C.Y.Cheng, Proceedings of 2008 International Symposium on Electrical Insulating Materials, September 7-11, Yokkaichi, Mie, Japan, 2008. [15] T. Krüger and R. Patsch, Active Noise Reduction for Partial Discharge Measurement in the Frequency Domain, IEEE Bologna Power Tech Conference, Bologna, Italy, June23th- 26th, 2003. [16] G. Chen and F. Baharudin, Partial Discharge Modeling Based on a Cylindrical Mode in Solid Dielectrics, International Conference on Condition Monitoring and Diagnosis, China, April 21-24, 2008. [17] C. Forssén and H.Edin, Partial Discharges in a Cavity at Variable Applied Frequency Part 1: Measurements, IEEE Transactions on Dielectrics and Electrical Insulation, Vol. 15, No. 6, December 2008. Copyright to IJAREEIE DOI:10.15662/IJAREEIE.2016.0508024 6764