INDIUM SENSOR. Type X.5 Series

Similar documents
The Standard for over 40 Years

Sensor PAR xxx

Ultraviolet (UV-Index) TOCON Datasheets

UV-Index Photodiodes Data Sheets

HD HD HD AND HD PHOTO-RADIOMETERS LG-2

THE WORLD OF WEATHER DATA

UV-Index Photodiodes Data Sheets

THE WORLD OF WEATHER DATA Measurement and Documentation: Thies range of service for meteorology, environmental protection and industry

LI-192 Underwater Quantum Sensor

Uses of Electromagnetic Waves

UV-A, UV-B & UV-I Sensors

The Standard for over 40 Years

Comparison of Quantum Sensors with Different Spectral Sensitivities

LI-193 Spherical Quantum Sensor

The Standard for over 40 Years

Light Sensors for Environmental Chambers

METAL HALIDE LAMPS FEATURES AND BENEFITS APPLICATIONS AQUALITE METAL HALIDE LAMPS FOR MARINE AQUARIUMS AND REEF SYSTEMS

High quality Full Sale or Return 7 Price points, RRPs ranging from lines and 3 styles; Classic, Sporty and Trendy

Light, Color, Spectra 05/30/2006. Lecture 17 1

Preventive Conservation and Energy conservation. Units of light, Perception of colour, Energy used by lighting.

UV RADIATION AND LIGHT

Product tags: VIS, Spectral Data, Color Temperature, CRI, Bilirubin, PAR, Scotopic, Luminous Color, Photometry, General lighting

MagicReflex. MagicReflex. Original Hanau SunCare. More Power and Life for Your Solaria. MagicReflex UV-Technology

Ground-Based Solar UV Radiation Monitoring Technique Using Photocell. Pulchowk Campus, Institute of Engineering, Tribhuvan University, Nepal

This document is a preview generated by EVS

Photo-Documentation of Ultraviolet Radiation Induced Visible Fluorescence on Daguerreotypes

AQUALITE METAL HALIDE

Radiometric and Photometric Measurements with TAOS PhotoSensors

Measuring the cover and shade protection factors of synthetic shadecloth

There are many types of light sources, ranging from natural sunlight to man-made artificial lightings.

Light Transmission and Reflectance

LP PHOT 03 LP RAD 03 LP PAR 03 LP UVA 03 LP UVB 03

Ambient Light Sensors General Application Note

Automotive Window Film Selector Guide LX Series

In Situ Measured Spectral Radiation of Natural Objects

BTS256-EF. Product tags: VIS, Spectral Measurement, Waterproof, WiFi. Gigahertz-Optik GmbH 1/7

\Ç à{x ÇtÅx Éy ALLAH à{x `xüv yâä

Light emitting diode (LED) Lighting for Greenhouse Crops

COLOUR INSPECTION, INFRARED AND UV

RAMSES. A modular multispectral radiometer for light measurements in the UV and VIS

Content of this Catalog. General information about the sglux TOCONs. Selection guide p. 2. Product details of all TOCONs p. 5. Useful accessories p.

LI-1500 Light Sensor Logger

Product tags: VIS, Spectral Data, Color Temperature, CRI, Waterproof, WiFi, Luminous Color, LED, Photometry, General lighting

17-1 Electromagnetic Waves

ISO Determination of sunscreen UVA photoprotection in vitro. Détermination in vitro de la photoprotection UVA. First edition

Light has some interesting properties, many of which are used in medicine:

The ultimate guide To living green Wall lighting

LP RAD 03 LP PAR 03 LP UVA 03 LP UVB 03 LP PHOT 03S

Electromagnetic Spectrum

How can we "see" using the Infrared?

Measurement and Measurement Error of Light Used for Photosynthesis & Plant Growth Richard Garcia April 20, 2010

Test 1: Example #2. Paul Avery PHY 3400 Feb. 15, Note: * indicates the correct answer.

Broadbandradiometer specbos 1211

H22: Lamps and Colour

CONSUMER GOODS TESTING

ELECTROMAGNETIC SPECTRUM ELECTROMAGNETIC SPECTRUM

Unit 1.5 Waves. The number waves per second. 1 Hz is 1waves per second. If there are 40 waves in 10 seconds then the frequency is 4 Hz.

HSL HUMAN SUN LIGHTING

4 - Channel SWIR Light Sensor

2 Channel Light Sensor

RTI Light Probe. For Measurements Of: RTI Light Probe User s Manual English Version A. RTI article number:

Silicon Pyranometer Smart Sensor (Part # S-LIB-M003)

Consumer Goods Testing

Longitudinal No, Mechanical wave ~340 m/s (in air) 1,100 feet per second More elastic/denser medium = Greater speed of sound

07-Lighting Concepts. EE570 Energy Utilization & Conservation Professor Henry Louie

Biological impact of optical radiation from curing lights

Figure 1. Relative intensity of solar energy of different wavelength at the earth's surface.

Application Note 26. Optical Hazard Measurements with JETI specbos 1211UV

Vision Lighting Seminar

Human Retina. Sharp Spot: Fovea Blind Spot: Optic Nerve

Section Electromagnetic Waves and the Electromagnetic Spectrum

LP PHOT LP RAD 03 LP PAR 03 LP UVA 03 LP UVB 03 LP PHOT 03S. Light

INSTRUCTION MANUAL UV RADIOMETERS

Ultraviolet Visible Infrared Instrumentation

Term Info Picture. A wave that has both electric and magnetic fields. They travel through empty space (a vacuum).

Innovative optical solutions. Inspector M2 Manual

Section Electromagnetic Waves and the Electromagnetic Spectrum

Model #2 UVB Midband Ultraviolet Lamp Assembly with Timer

polarized collection version 17.1

Horticultural Lighting Test Report

Note 2 Electromagnetic waves N2/EMWAVES/PHY/XII/CHS2012

Multi-Lamp Microwave UV Systems Physics and Technology

Solar lighting system HIMAWARI

Spectroradiometer specbos 1201

CHAPTER 7. Components of Optical Instruments

Infrared Illumination for Time-of-Flight Applications

Conforming to the ICH Guideline for the Photostability Testing of New Drug Substances and Drug Products (ICH Q1B) Using the Atlas SUNTEST CPS+

Colours Learning Outcomes

Colours Learning Outcomes. Colours Learning Outcomes. Electromagnetic Spectrum

Illumination Guide. Choosing the right lighting to evaluate products

Package photobiologysensors

Brightness Transmitter

GLOSSARY OF TERMS. Terminology Used for Ultraviolet (UV) Curing Process Design and Measurement

The New Standard in Lightfastness Testing. Q-Sun B02 Xenon Lightfastness Tester. The Lightfastness Specialists

Spectral Pure Technology

Lesson 1: Introduction to Sun Protection. Student Materials

BTS256-E WiFi - mobile light meter for photopic and scotopic illuminance, EVE factor, luminous color, color rendering index and luminous spectrum.

Experiment E-6 Rayleigh Scattering

INNOVATIVE CAMERA CHARACTERIZATION BASED ON LED LIGHT SOURCE

Electromagnetic Waves & the Electromagnetic Spectrum

Transcription:

Type X.5 Series This type is meeting higher demands in accuracy. It's equpped with a light entrance window made of flat glass (or a PMMA if preferred). The material is UV-penetrable and long term resistant against radiation and environmental influences, and is therefore being used eg. in submarines and aircraft cockpits as well. Other materials (glass, quartz) can be used if required. Flat polished glass offers the best receiving characteristics, it is tested with greatest care. Screwed and silicone-sealed housing parts are protecting the interior. This series is appropriate for indoor use. If required it may be upgraded for outdoor use as well. The aluminum housing is anodized for scratch-resistance and long term use.

UV-C measuring head type 0.5 UV-C sensitivity Long UV radiation (above 313 nm) makes people tan and has positive effects on the human immune system. Shorter UV-radiation in contrast may cause irreversible damage and is listed in a recommendation by CIE (Commission Internationale de l Eclairage) which summarizes all action spectra that may cause damage to the human skin. This recommendation is standardized in German DIN 5050. A popular example is the UVI sunburn index. UVC measuring head type 0.5 Relative spectral sensitivity of this measuring head has been developed to determine UVC-radiation (mercury line, 256nm). The sensor is measuring the parts of this range which cause damage to human skin, Measuring results are allowing immediate conclusions about medically and biologically relevant connections within this band of radiation. The measuring head is used in medicine, biological research, weather information and forecast systems, in climate research and for public information in general. The measuring head type 0.1 has a weatherproof aluminum housing. The housing is made of weatherproof anodized aluminum. The values are cosine corrected. spectral sensitivity UV-C DIN 5050 200 225 250 275 300 325 350 wavelength in nm measuring range UV-C spectral sensitivity max. spectral sensitivity window lineartity dark o 42mm 0-1990 mw/m² 220 nm - 280 nm 265 nm 0 C - +60 C 0 V - 2 V on request +5 V / <750 µa flat glass or PMMA error f2 < 6 % < 1 % < 10 mv 50mm Fax: +49(0)3342 80239

UVB measuring head type 1.5 UVB sensitivity Long UV radiation (above 313 nm) makes people tan and has positive effects on the human immune system. Shorter UV-radiation in contrast may cause irreversible damage and is listed in a recommendation by CIE (Commission Internationale de l Eclairage) which summarizes all action spectra that may cause damage to the human skin. This recommendation is standardized in German DIN 5050. A popular example is the UVI sunburn index. UVB measuring head type 1.5 The relative spectral sensitivity of the detector is equal to the erythema action spectrum (DIN5050). The UVE sensor is exactly measuring the elements of this spectral range which cause damage to human cells. The determined value is allowing conclusions about biological and medical interrelations. The measuring head is used in medicine, biological research, weather information and forecast systems, in climate research and for public information, especially in solariums/tanning beds and for suntanning. The device has a housing made of aluminum and is developed to be used with our handheld device type 6.4. Measuring range UVB spectr. sensitivity UVB max.spectral sensitivity UVB dark Spectrale sensitivity UV-B DIN 5050 250 275 300 325 350 375 400 wavelength / nm 0-50 µw/m² 265 nm - 315 nm 297 nm 0V-5V or similar +9V - 18V / <750µA PMMA/flatglass or quartz error f2 < 6 % < 1% < 10% ( < 0,2%/K) < 10mV o 42mm 50mm Fax: +49(0)3342 80239

UVA/UVB measuring head type 2.5 UVB sensitivity Long UV radiation (above 313 nm) makes people tan and has positive effects on the human immune system. Shorter UV-radiation in contrast may cause irreversible damage and is listed in a recommendation by CIE (Commission Internationale de l Eclairage) which summarizes all action spectra that may cause damage to the human skin. This recommendation is standardized in German DIN 5050. A popular example is the UVI sunburn index. UVB measuring head type 2.5 The measuring head independently determines UV-Aradiation (global, from 315nm - 400nm). Measuring results are allowing immediate conclusions about medically and biologically relevant connections within this band of radiation. The measuring head is used in medicine, biological research, weather information and forecast systems, in climate research and for public information in general. The device has a housing made of aluminum and is developed to be used with our handheld device type 6.4. Measuring range UVA spectr. sensitivity UVA max.spectral sensitivity UVA signaloutput cosine correcture 250 275 300 325 350 375 400 veavelength in nm 0-50 W/m² 310 nm - 400 nm 335 nm 04 ma.. 20 ma +6V -24 V/ <750µA PMMA error f2 < 6 % < 1% < 10% ( < 0,2%/K) < 10mV Specifications are subject to change without prior notice o 36mm 36mm Spektrale sensitivity CIE UV-B typical radiation of solarium Tel: (03342) 80239 Fax: (03342) 80239

Global radiation measurement head type 3.5 Global radiation All diffuse and direct solar radiation reaching the surface of the earth is called global radiation. It ranges from short (300nm (UV-B) ) to long (5000 nm (IR)) wavelength. Global measuring head type 3.5 The sensor detects almost 90% of sunlight in the range of wavelength between 400 nm and 1100 nm and is covering the range of the uv-, vis- and some of the ir-light. The measuring results are allowing conclusions about medical and biological connections by comparing to other spectral ranges. The measuring head can be used in medical and biological research, in weather information and forecast systems, in climate research, in agriculture and for public information in general. The measuring head type 3.5 has a weatherproof aluminum housing. The results are cosine corrected. The is made of plastic or flat glass.this device can be equipped with 4 different output signal variations. Measuring range global spectr. sensitivity max. spectr.sensitivity 400 500 600 700 800 900 1000 wavelength / nm cable dom 0 - at 1600 W/m² 400 nm - 1100 nm 780 nm 0V - 5V or +10V - +24V PMMA/ flat glass error f2 < 6% < 1% < 20 mv o 42 mm 65 mm Spektral sensitivity Global Sun GmbH 15366 Neuenhagen Germany Fax: +49(0)3342 207886

Visual radiation sensor type 4.5 V-lambda-radiation Spectral response The spectral range of light visible to the human eye is called V-Lambda-Radiation. The measured value is a depiction of the subjectively perceived brightness. Spectral range extends from the end of UV-light at 400nm to the start of IR-light at 720nm with a maximum at 555nm. The measured value of illuminance in W/m² can easily be converted into Lux. Measuring results are important for any projects involving the human perception of light and the illumination of workplaces. V- lambda radiation sensor type 4.5 The measuring head may be used in medical and biological research, weather information and forecast systems, climate research, agriculture and engineering. The measuring head type 4.5 has a weatherproof aluminum housing. The is made of plastic or flat glass. The values are cosine corrected. Relative response 400 450 500 550 600 650 700 wavelength in nm Measuring range V-lambda spektr. sensitivity max. spectral sensitivity 0 - ca. 20 klux or o. 360 nm - 760 nm 550 nm 0 V.. 5 V or similar +6V - +24V / <500µA in the ground of body PMMA/flat glass error f2 < 6% < 1 % < 10 mv o 42mm 50mm GmbH Fax:+49(0)3342 80239

Photosynthetically Geschäftsbereich active radiation Umwelttechnik sensor type 5.5 Photosynthesis activity The ability to absorb light radiation is required for herbal life, chlorophyll has a special significance in that process. If the intensity of light is too low, the plant will not get enough energy to grow, if the intensity is too high the plant will emit energy as fluorescence. This is an indication for the growth conditions of a plant. If the light is too strong the plant will get dry and burned. Photosynthesis (PAR) sensor type 5.5 Sensitivity corresponds to the absorption spectrum of chlorophyll. Measuring results are allowing immediate conclusions about the conditions for plant growth. The PAR measuring head may be used for optimizing photochemical processes of open-land and greenhouse agriculture. The sensor is used in agricultural research, gardening, agriculture as well as in education. The housing is made of weatherproof anodized aluminum. Results are cosine corrected. The is made of plastic (PMMA) or flat glass. spectral sensitivity 400 450 500 550 600 650 700 weavelength in nm Technical specification measuring range spectr. sensitivity max. spectr. sensitivity Sensor Chlorophyll 0 - ca. 250 W/m² 380 nm - 700 nm 420 nm und 600 nm 0V - 2V or similar +9V - +24V / < 750µA PMMA/flat glass error f2 < 6% < 1 % < 10 mv o 42mm 50mm Fax: +49(0)3342 80239

Quantum radiation Geschäftsbereich sensor type Umwelttechnik 6.5 Quantum Radiation Spectral sensitivity The ability to absorb light radiation is required for herbal life, chlorophyll has a special significance in that process. If the intensity of light is too low, the plant will not get enough energy to grow, if the intensity is too high the plant will emit energy as fluorescence. This is an indication for the growth conditions of a plant. If the light is too strong the plant will get dry and burned. Quantum sensor type 6.5 Sensitivity corresponds to the absorption spectrum of chlorophyll. Measuring results are allowing immediate conclusions about the conditions for plant growth. The quantum measuring head may be used for optimizing photochemical processes of open-land and greenhouse agriculture. The sensor is used in agricultural research, gardening, agriculture as well as in education. The housing is made of weatherproof anodized aluminum. Results are cosine corrected. The is made of plastic (PMMA) or flat glass. Daylight type 6.5 new type 6.5 type 5.5 glob. rad. Daylight 4,04 W/m² 3,38 W/m² 0,858 W/ m² 8 W/m² Daylight 18,62µmol/sm² 15,55µmol/sm² 3,95 µmol/sm² 400 450 500 550 600 650 700 weavelength in nm Technical specification Measuring range spectr. sensitivity max. spectr. sensitivity abs.error sensor 6.3 quantum 0 - ca. 650 W/m² 380 nm - 700 nm 420 nm and 600 nm 0V - 5V or other +10V - +24V / < 750µA 2 screws M3 PMMA or flat glass error f2 < +/-6% < +/-1 % < +/-10 % < 10 mv Specifications are subject to change without notice. o 42 mm 65 mm 15366 Neuenhagen Germany Tel: +49(0)3342 80238 Fax: +49(0)3342207886

Global radiation measuring head type 7.5 Global radiation The complete direct and diffuse sun radiation hitting the ground is called global radiation. The spectral range extends from the short-wave range at 300 nm (UV-B) to the long-wave range at 5000 nm (IR). The radiation energy above 1000nm however is less then 10% only. Spektrale sensitivity Global Global measuring-head type 7.5 400 500 600 700 800 900 1000 wavelength in nm o 42 mm 65 mm The sensor is able to detect almost 90% of the sunlight in the range between 400 nm and 1100 nm and includes UV, VIS and some of IR. Measuring results are allowing immediate conclusions about medically and biologically relevant connections by comparing them to other spectral ranges. The measuring head may be used in medicine, biological research, weather information and forecast systems, in climate research and for public information in general. The measuring head of type 7.5 has a weather resistant case, made of aluminium. The measuring results are cosine corrected. The is made of plastic (PMMA) or flat glass. Measuring range global spectr. sensitivity max. spectr.sensitivity cable 0 - at 1300 W/m² 400 nm - 1100 nm 780 nm 0V - 5V a.o. +10V - +24V PMMA/ flat glass error f2 < 6% < 1% < 20 mv Specifications are subject to change without notice. Fax: +49(0)3342 207886

Infrared measuring head type 8.5 Geschäftsbereich Umwelttechnik Infrared radiation The direct and diffuse solar radiation in the range from 700 nm up to 5000 reaching the ground is called infrared radiation. Infrared measuring head type 8.5 The sensor detects almost 30 % of the sunlight in the range of 800 nm to 1100 nm including the most relevant part of IR. Measuring results are allowing immediate conclusions about medically and biologically relevant connections by comparing them to other spectral ranges. The measuring head may be used in medicine, biological research, weather information and forecast systems, in climate research and for public information in general. The measuring head may be used in medicine, biological research, weather information and forecast systems, in climate research and for public information in general. The aluminum housing is weatherproof, the is made of plastic or flat glass. The measuring results are cosine corrected. spectral sensitivity IR 600 700 800 900 1000 1100 1200 wavelength in nm measuring range global spectral sensitivity max. spectral sensitivity dark weigth 0 - approx. 400 W/m² 800 nm - 1100 nm 950 nm -20 C - +60 C 0 V - 2 V or other +5 V - +18 V of the case PMMA/flat glass error f2 < 6 % < 1 % < 10 mv o 42mm 50mm Fax: +49(0)3342 207886