Abstract. Index Terms Healthcare model, Paralysis, Surface electromyography, wireless engineering.

Similar documents
HUMAN BODY MONITORING SYSTEM USING WSN WITH GSM AND GPS

Lecture 4 Biopotential Amplifiers

International Journal of Electronics and Communication Engineering & Technology (IJECET), ISSN COMMUNICATION ENGINEERING & TECHNOLOGY (IJECET)

International Journal of Scientific & Engineering Research, Volume 5, Issue 5, May ISSN

EDL Group #3 Final Report - Surface Electromyograph System

CHAPTER 7 INTERFERENCE CANCELLATION IN EMG SIGNAL

ULP Wireless Technology for Biosensors and Energy Harvesting

Wireless Transmission of Real Time Electrocardiogram (ECG) Signals through Radio Frequency (RF) Waves

Introduction to Medical Electronics Industry Test Analysis and Solution

WIRELESS ELECTRONIC STETHOSCOPE USING ZIGBEE

BME 405 BIOMEDICAL ENGINEERING SENIOR DESIGN 1 Fall 2005 BME Design Mini-Project Project Title

A Design Of Simple And Low Cost Heart Rate Monitor

JOURNAL OF ADVANCEMENT IN ENGINEERING AND TECHNOLOGY

Weekly Update Michael Jorgensen Week of 2/25/11 3/3/11

Development of Electrocardiograph Monitoring System

Laboratory Project 1B: Electromyogram Circuit

Bio-Potential Amplifiers

DESIGN AND IMPLEMENTATION OF EMG TRIGGERED - STIMULATOR TO ACTIVATE THE MUSCLE ACTIVITY OF PARALYZED PATIENTS

ECE 445 Fall 2017 Project Proposal. Recovery-Monitoring Knee Brace

6.101 Introductory Analog Electronics Laboratory

Robust Wrist-Type Multiple Photo-Interrupter Pulse Sensor

WRIST BAND PULSE OXIMETER

DESIGN OF A PHOTOPLETHYSMOGRAPHY BASED PULSE RATE DETECTOR

International Journal of Advancements in Research & Technology, Volume 2, Issue 12, December ISSN

For Immediate Release. For More PR Information, Contact: Carlo Chatman, Power PR P (310) F (310)

A Twenty-Four Hour Tele-Nursing System Using a Ring Sensor

Design of Virtual Sphygmomanometer Based on LABVIEWComparison, Reflection, Biological assets, Accounting standard.

The report presents the functionality of our project, the problems we encountered, the incurred costs and timeline for the project development.

An Electromyography Signal Conditioning Circuit Simulation Experience

PHYSIOLOGICAL SIGNALS AND VEHICLE PARAMETERS MONITORING SYSTEM FOR EMERGENCY PATIENT TRANSPORTATION

REAL-TIME WIRELESS ECG AND ITS SIGNAL DISPLAY ON LABVIEW

BME 3113, Dept. of BME Lecture on Introduction to Biosignal Processing

A Body Area Network through Wireless Technology

ENGR 499: Wireless ECG

HUMAN DETECTION AND RESCUE USING BIO POTENTIAL SIGNALS

E-health Project Examination: Introduction of an Applicable Pulse Oximeter

EMG Electrodes. Fig. 1. System for measuring an electromyogram.

Massachusetts Institute of Technology MIT

DESIGN OF A LOW COST EMG AMPLIFIER WITH DISCREET OP-AMPS FOR MACHINE CONTROL

AN4995 Application note

ECONOMICAL HEART RATE MEASUREMENT DEVICE WITH REMOTE MONITORING USING FINGERTIP

EMG click PID: MIKROE-2621

ECG Project. Raphal Blanchet, Axel Boland, Thomas Donnay, Mario Jose Teles Varandas, University of Liege

BIO-ELECTRIC MEASUREMENTS

BENG 186B Principles of Bioinstrumentation. Week 7 Review. Solutions

SUITABILITY STUDY OF DS-UWB AND UWB-FM FOR MEDICAL APPLICATIONS

Design on Electrocardiosignal Detection Sensor

LOW VOLTAGE / LOW POWER RAIL-TO-RAIL CMOS OPERATIONAL AMPLIFIER FOR PORTABLE ECG

Biometric Data Collection Device for User Research

Removal of Power-Line Interference from Biomedical Signal using Notch Filter

CHAPTER 3. Instrumentation Amplifier (IA) Background. 3.1 Introduction. 3.2 Instrumentation Amplifier Architecture and Configurations

Multi Propose Biomedical Circuit

EXPERIMENT 8 Bio-Electric Measurements

A Finite Impulse Response (FIR) Filtering Technique for Enhancement of Electroencephalographic (EEG) Signal

Wireless Cardiac Rhythm Monitoring System

LOW-COST WIRELESS TELEMETRY SYSTEM FOR DEEP BRAIN STIMULATION

A CMOS-based Tactile Sensor for Continuous Blood Pressure Monitoring

USABILITY OF TEXTILE-INTEGRATED ELECTRODES FOR EMG MEASUREMENTS

BIOMEDICAL INSTRUMENTATION PROBLEM SHEET 1

11. Audio Amp. LM386 Low Power Amplifier:

CEEN Bot Lab Design A SENIOR THESIS PROPOSAL

A Solar-Powered Wireless Data Acquisition Network

Motivation. Approach. Requirements. Optimal Transmission Frequency for Ultra-Low Power Short-Range Medical Telemetry

Removal of Motion Noise from Surface-electromyography Signal Using Wavelet Adaptive Filter Wang Fei1, a, Qiao Xiao-yan2, b

Hydra: A Three Stage Power Converter

Chest Worn Pulse Oximeter Integrating NI-USRP with GPS Disciplined Clock Transceiver

EE 3101 ELECTRONICS I LABORATORY EXPERIMENT 9 LAB MANUAL APPLICATIONS OF IC BUILDING BLOCKS

Biomedical Sensor Systems Laboratory. Institute for Neural Engineering Graz University of Technology

Wireless ECG Monitoring System Project Report

We are IntechOpen, the first native scientific publisher of Open Access books. International authors and editors. Our authors are among the TOP 1%

Fast IC Power Transistor with Thermal Protection

PORTABLE ECG MONITORING APPLICATION USING LOW POWER MIXED SIGNAL SOC ANURADHA JAKKEPALLI 1, K. SUDHAKAR 2

Analysis of Instrumentation Amplifier at 180nm technology

Florida Atlantic University Biomedical Signal Processing Lab Experiment 2 Signal Transduction: Building an analog Electrocardiogram (ECG)

Name Kyla Jackson, Todd Germeroth, Jake Spooler Date May 5, 2010 Lab 3E Group 3 Experiment Title Project Deliverable 3

Instrumentation amplifier

IMPROVEMENTS IN ELECTROCARDIOGRAPHY SMOOTHENING AND AMPLIFICATION

Wireless Music Dock - WMD Portable Music System with Audio Effect Applications

Wireless Heartbeat Monitoring System Using Android

Soldier Tracking and Health Indication System Using ARM7 LPC-2148

Breakthrough: Electronic circuits that are integrated with your skin

Multi-Stage Power Conversion Proposal

Health and Fitness Analog solution. Wenbin Zhu Medical BDM June, 2015

Chapter 4 4. Optoelectronic Acquisition System Design

Special-Purpose Operational Amplifier Circuits

Available online at ScienceDirect. Procedia Computer Science 105 (2017 )

Laboratory Project 1: Design of a Myogram Circuit

Project Report. Object Following Robot

Design of High gain and Low Offset CMOS Current Mode Front End Operational Amplifier

Design and Implementation of Digital Stethoscope using TFT Module and Matlab Visualisation Tool

EE 233 Circuit Theory Lab 3: First-Order Filters

A New Low-Cost Bionic Hand

School of Electronic Science and Engineering, Nanjing University of Posts and Telecommunications, Nanjing, , China

Deepali Shukla 1 (Asst.Professor), Vandana Pandya 2 (Asst.Professor) Medicaps Institute of Technology & Management, Indore (M.P.

EE 230 Experiment 10 ECG Measurements Spring 2010

ELG3336 Design of Mechatronics System

PROCESSING ECG SIGNAL WITH KAISER WINDOW- BASED FIR DIGITAL FILTERS

ELR 4202C Project: Finger Pulse Display Module

Portable, Low Cost, Low Power Cardiac Interpreter

Package Architecture and Component Design for an Implanted Neural Stimulator with Closed Loop Control. Caroline K. Bjune

Transcription:

Surface Electromyography In Healthcare Solution Prof. Meghayu Adhvaryu, assistant professor, Bhagwan Mahavir College Of Engineering And Technology, Surat Abstract With miniaturization and technical advancements in electronics and communications field, we are now in a position to safely monitor, diagnose and treat various intricate ailments in patients with relative ease. This has made complex surgeries simple, easy and efficient. Wireless communications have enabled development of monitoring devices that can be made available for general use by individuals/patients and caregivers. New methods for short-range wireless communications not encumbered by radio spectrum restrictions (e.g., ultra-wideband) will enable applications of wireless monitoring without interference in ambulatory subjects, in home care, and in hospitals. Wireless biomonitoring, first used in human beings for featal heart-rate monitoring has now become a technology for remote sensing of patients' activity, blood pulse pressure, oxygen saturation, internal pressures, orthopedic device loading, and gastrointestinal endoscopy. Biotelemetry provides a wireless link between the subject and the remote site where the recording, signal processing, and displaying functions are performed. Rather than using a traditional radio transceiver, which can only broadcast over a limited range, now-a-days the readily available cell phones are used to transmit biological data by creating a link between the subject and a computer receiving the signal via a landline phone. Wireless telemetry of bioelectric signals, specifically neural recordings, is desirable in many research and clinical applications. These include, but are not limited to telemetry and recording of neural activity in laboratory animals, telemetry of EEG, telemetry of short-term implanted electrode arrays for epilepsy medical diagnosis, functional electrical stimulation (FES) systems, and implantable neuroprosthetic devices for sensory and command control. This study will focus on Wireless telemetry in general and also details of Wireless biotelemetry. Index Terms Healthcare model, Paralysis, Surface electromyography, wireless engineering. 1.0 Introduction To the system The main goal of this study was to design and implement a wirelessly transmitted activity monitor. This design was to record heart rate as well as blood pressure. This data would be used to determine a person s physical capabilities using a job match method. This method would then analyze a person s heart rate and blood pressure during different physical activities to determine whether or not they are capable of performing the duties required of an occupation. As a person increases in age, their heart may not be able to support the same physical activities it could when he or she were younger. The primary users of this device, occupational therapists, will check the measurements against a reference to determine the candidate s suitability for the position. It can also be used to evaluate recovery from injury, or even the validity of claims of on-site injuries in the workplace. This method and device would result in an entirely new approach to workman s compensation, and drastically cut down on false claims. Given the wireless nature of the device and its capability to interface with the majority of PC s on the market, networking it to a hospital or EMT service for high-risk patients in the home is also an added benefit. There are many people who suffer from heart diseases and high blood pressure. There have been multiple cases where one of these individuals has a heart attack and no one can get to them fast enough to resuscitate them. The wireless activity monitor, in part, is designed to give these individuals a better chance of survival by monitoring their heart rate and blood pressure and transmitting the data wirelessly to a local computer. If a person s heart rate or blood pressure shows abnormal activity a hospital can be notified immediately over the Internet and a paramedic can be dispatched to the person s house. Being a light weight package and oriented on the body in a way as to not interfere with job tasks, daily activities, or test procedures, this will become a highly valuable evaluation tool when dealing with physical activity. The design goals for this project were to acquire heart rate and blood pressure readings from a wrist mounted cuff, transmit those readings wirelessly to a local computer, access those readings remotely over a network using a different computer, and display those readings in an intuitive display. 1.1 Definition of Wireless Biotelemetry Biotelemetry is defined as a means of transmitting biomedical or physiological data from a remote location (e.g., astronauts in space) to a location that has the 1060

capability to interpret the data and affect decision making (e.g. ground controllers at Mission Control Center). Biotelemetry is a vital constituent in the field of medical sciences. It entails remote measurement of biological parameters. Mode of transmission of physiological data from point of generation to the point of reception can take many forms. Use of wires to transmit data may be eliminated by wireless technology. Biotelemetry, using wireless diagnosis, can monitor electronically the symptoms and movements of patients. This development has opened up avenues for medical diagnosis and treatment. It enables monitoring of activity levels in patients suffering from heart trouble, asthma, pain, Alzheimer s disease, mood disorders, cardiovascular problems, accidents, etc. There are usually two concerns associated with the use of biotelemetry: the distance over which the signal can be received, and the size of the transmitter package. Often, both of these concerns depend on the power source for the transmitter. Integrated circuits and surface mount technology allow production of very small electronic circuitry in transmitters, making batteries the largest part of the transmitter package.[1] Figure 1 shows the Human implantable system. 1.2 Definition of EMG[1] "Electromyography (EMG) is an experimental technique concerned with the development, recording and analysis of myoelectric signals. Myoelectric signals are formed by physiological variations in the state of muscle fiber membranes." Neurological EMG, where an artificial muscle response due to external electrical stimulation is analyzed in static conditions, the focus of Kinesiological EMG can be described as the study of the neuromuscular activation of muscles within postural tasks, functional movements, work conditions and treatment/training regimes. Figure 1 Implantable units Figure 2 Basmajian & DeLuca: Definition Muscles Alive Unlike the classical 1.3 Definition of Pulse (Heartbeat) rate:[7] The pulse is a decidedly low tech/high yield and antiquated term still useful at the bedside in an age of computational analysis of cardiac performance. Claudius Galen was perhaps the first physiologist to describe the pulse. The pulse is an expedient tactile method of determination of systolic blood pressure to a trained observer. Diastolic blood pressure is nonpalpable and unobservable by tactile methods, occurring between heartbeats. 1061

amplifier uses a typical differential amplifier circuit, which contains two inputs (positive input and negative input). The differential amplifier circuit subtracts two inputs and amplifiers the difference. To get the right level of the input signal, we need a body reference which works as a feedback from the inputs. Whenever the signal changes due to noise introduced by the body, this body reference will help maintain the correct level of signal. 2.3 Instrumentation Amplifier 2.1 Block Diagram: Figure 3 Pulse rate basics 2.0 System design Figure 6 Burr brown using INA128 2.2 EMG amplifier Figure 4 Block Diagram Figure 5 Burr brown amplifier A suitable operational amplifier (op-amp) for this type of application is the Instrumentation Amplifier. Its versatile 3-op amp design and small size make it ideal for a wide range of applications. This type of op-amp usually provides excellent accuracy because it provides high bandwidth even at high gain. The EMG amplifier used a BURR-BROWN, INA128 chip for the amplifier, as suggested by the application information data sheet of lm 124. The gain of the amplifier can be adjusted by changing the resistor Rg between pin number 1 and 8. 2.3.1 Low pass filter: When handling pulse trains and signal bursts of EMG signals, it might be favorable to use filters which have negligible over-shoot. When handling pulse trains and signal bursts, it might be favorable to use filter which have negligible over shoot in the step response. A class of filters particularly suitable for this type of signals is the Bessel filter. The phase characteristics of this class of filters exhibit a linear increase with frequency. The group delay, defined as the derivative of the phase with respect to frequency, is hence extremely flat over a wide range of frequencies. Frequency range of EMG signal is between 50-150Hz so 4th order Bessel filter is required for the low pass filtration of 150Hz. As explained earlier, EMG signal is so small that computer could not read it. While the amplitude of the signal is between 0 to 10 mill volts (peak-to-peak), the usable frequency of an EMG signal is ranging between 50-150 Hz [1]. At this state, we need a huge gain (about thousand times) to boost the EMG signal without changing phase or frequency of the signal. This 1062

4.3.3 Pulse monitoring System Figure 7 Low Pass filter design in filter pro 4.3.2 High pass filter: The dominant energy of the EMG signal is located in the 50-150 Hz range, to eliminate the movement artifacts, inherent instability of the signal which ranges between 0 to 15 Hz and the ambient noise arises from the 60 Hz 1st order high pass filtration of 50Hz is required. Figure 9 Pulse monitoring system 5.1 Observed signals Recorded samples from the digital oscilloscope using the developed EMG amplifier device. The samples were recorded in real time from real human hand. The experiment preformed grasping of objects of different sizes and shapes.vpp = 484mV, Frequency =140.4Hz Figure 8 High Pass filter design in filter pro 5.2 result Suggestions for further advancements The feasibility of the signals can be improved using suction cup electrodes rather than the Peel-and-stick surface electrode. The use of surface electrode was owing to the unavailability of the suction cup electrode and the cost constraints. Better performance can also be obtained with the help of electrodes with built in preamplifiers. The signals obtained from the body can 1063

be converted into digital form and can be further processed digitally using digital processors to carry out various analysis related to the muscular structure as well as their functioning. The microcontroller incorporated in the project can be used as a base to work upon and develop various functionalities such as emergency braking, obstacle detection and many more. The EMG amplifier, the size of the enclosure should be considered. The electrode extensions should be eliminated. The amplifier should be able to hold electrodes directly on the unit. The amplifier and electrode holders could be placed in the same PCB which has a connector to transfer the output to the microcontroller unit. This amplifier unit would be then placed directly on the hand. Conclusion & Future work The WPMG system has been developed and tested that support single channel. The WSEMG amplifier device is designed to amplify EMG signals from muscle groups on the upper forearm. The footprint of the complete system includes electrodes, amplifier, filters, microcontrollers and ZigBee Modems. The EMG amplifier uses skin surface electrodes as input sensors. The amplifier is a battery powered differential instrumental amplifier which raises very weak and noisy EMG signals to a stable level for wireless transmission. The filter is applied to select only the bandwidth of signals that is of interest for the underlying applications. The microcontrollers and ZigBee modems are used for wireless transmission of EMG signals. The major problems in developing the above listed components were to reduce noise, moving artifacts, system grounding and DC bias. Similarly we can see noisy pulse rate signal on the receiver side.all these problems were successfully solved through the following steps: 1. Proper choice of discrete components (resistors, capacitors, and ICs). 2. Proper design of circuitry. 3. Final implementation of the device using PCB technology. 4. Systematic experimentation with the prototype (implemented on a breadboard). 5. Extensive testing of the device after implementation and executing final corrections. The concerns over the systems are: 1. Size of the system. 2. Distance over which data needs to travel. 3. Cost of the system. In future I can use some more physiological data like temperature, blood pressure, blood flow and technological data like ECG, EEG and data like to observe the patient completely and analysis the full body parameter using wireless media like ZigBee. So in future doctor can analysis the patient totally from remote location. if we can able to achieve the operation it will open a door in wireless biotelemetry domain to the next level of research. References: 1) Cromwell: Biomedical Instrumentation and measurement. 2) M. Steyaert, S. Gogaert, T. Van Nuland, and W. Sansen,.A low-power portable telemetry system for eight-channel EMG measurements,. In Proc. Annu. Int. IEEE-EMBS Conf., vol. 13, 1991, pp. 1711.1712. 3) Masayuki Ohyama, Yutaka Tomita, Satoshi Honda, Hitoshi Uchida, Noriyoshi Matsuo Active Wireless Electrodes for Surface Electromyography, 18th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, Amsterdam 1996. 4) Chien C.-N., Hsu, H.-W., Jang J.-K., Rau C.-L., and Jaw F.-S., Microcontroller-based wireless recorder for biomedical signals, Proceedings of the 2005 IEEE Engineering in Medicine and Biology 27th Annual Conference Shanghai, China, September 1-4, 2005. 5) Geer, D., Users Make a Beeline for ZigBee Sensor Technology, IEEE Computer Society, Vol. 38, pp 16-19, December 2005. 6) McDermott-Wells, P., What is Bluetooth?, IEEE Potentials, Vol. 23, pp 33 35, December 2004. 7) Emly, M.S., Gilmor, L.D., and Roy, S.H., Electromyography, IEEE Potentials., Vol. 11, pp 25-28, April 1992. 8)Patrick Kinney, ZigBee Technology: Wireless Control that Simply Works, Communications Design Conference, 2 October 2003. 1064