Multispectral. imaging device. ADVANCED LIGHT ANALYSIS by. Most accurate homogeneity MeasureMent of spectral radiance. UMasterMS1 & UMasterMS2

Similar documents
Imaging Photometer and Colorimeter

ISS-30-VA. Product tags: Integrating Sphere Source. Gigahertz-Optik GmbH 1/5

High spatial resolution imaging colorimeter and gloss-meter for measurements of small parts

Spectroradiometer specbos 1201

SPECTRAL SCANNER. Recycling

Miniaturized Spectroradiometer

Spectroradiometer CS-2000/2000A. The world's top-level capability spectroradiometers make further advances with addition of second model to lineup.

Achieving 100,000 : 1 contrast measurement

Broadbandradiometer specbos 1211

CS-2000/2000A. Spectroradiometer NEW

We bring quality to light. MAS 40 Mini-Array Spectrometer

Spectroradiometer CS-2000/2000A. The world's top-level capability spectroradiometers make further advances with addition of second model to lineup.

NEAR EYE DISPLAY (NED) SPECTRORADIOMETER SYSTEMS DATASHEET

Unprecedented Resolution and Accuracy For Camera & Image Sensor Calibration

JETI Specbos Instruments

Ideal for display mura (nonuniformity) evaluation and inspection on smartphones and tablet PCs.

Novel Approach for LED Luminous Intensity Measurement

POTENTIAL OF MULTISPECTRAL TECHNIQUES FOR MEASURING COLOR IN THE AUTOMOTIVE SECTOR

INNOVATIVE CAMERA CHARACTERIZATION BASED ON LED LIGHT SOURCE

NFMS THEORY LIGHT AND COLOR MEASUREMENTS AND THE CCD-BASED GONIOPHOTOMETER. Presented by: January, 2015 S E E T H E D I F F E R E N C E

Ideal for display mura (nonuniformity) evaluation and inspection on smartphones and tablet PCs.

DEFINING A SPARKLE MEASUREMENT STANDARD FOR QUALITY CONTROL OF ANTI-GLARE DISPLAYS Presented By Matt Scholz April 3, 2018

A High-Speed Imaging Colorimeter LumiCol 1900 for Display Measurements

Solid State Luminance Standards

Gamma Scientific Display Measurement Systems

WHITE PAPER. Methods for Measuring Flat Panel Display Defects and Mura as Correlated to Human Visual Perception

pco.edge 4.2 LT 0.8 electrons 2048 x 2048 pixel 40 fps up to :1 up to 82 % pco. low noise high resolution high speed high dynamic range

IMAGE SENSOR SOLUTIONS. KAC-96-1/5" Lens Kit. KODAK KAC-96-1/5" Lens Kit. for use with the KODAK CMOS Image Sensors. November 2004 Revision 2

GCMS-3 GONIOSPECTROPHOTOMETER SYSTEM

idonus UV-LED exposure system for photolithography

Improving the Collection Efficiency of Raman Scattering

WP640 Imaging Colorimeter. Backlit Graphics Panel Analysis

BioSpectrum Imaging System

Estimation of spectral response of a consumer grade digital still camera and its application for temperature measurement

We bring quality to light. LumiCam 1300 Imaging Photometer/Colorimeter

pco.1300 solar cooled digital 12bit CCD camera system

MS260i 1/4 M IMAGING SPECTROGRAPHS

PHOTO RESEARCH, INC. PR-730 / PR-735 and PR-740 / PR-745 SpectraScan

Why select a BOS zoom lens over a COTS lens?

Optical basics for machine vision systems. Lars Fermum Chief instructor STEMMER IMAGING GmbH

specification display & lighting hera spectrometer

Company synopsis. MSU series

WaveMaster IOL. Fast and accurate intraocular lens tester

Difrotec Product & Services. Ultra high accuracy interferometry & custom optical solutions

A simulation tool for evaluating digital camera image quality

Luminous Flux (lumens) System LM-ISP-XXXX

Spectral Analysis of the LUND/DMI Earthshine Telescope and Filters

Dual-FL. World's Fastest Fluorometer. Measure absorbance spectra and fluorescence simultaneously FLUORESCENCE

High-Accuracy Luminance & Chromaticity Measurement Comparable to Many Spectroradiometers

LED Lighting Flux and Color Measurement System (LFC)

Full Spectrum. Full Calibration. Full Testing. Collimated Optics, Software and Uniform Source Solutions

Automated Imaging Technology to Simplify Your Workflow!

Digital Image Processing

The Art of Light Measurement. Avantes BV Apeldoorn, The Netherlands

Aqualog. CDOM Measurements Made Easy PARTICLE CHARACTERIZATION ELEMENTAL ANALYSIS FLUORESCENCE GRATINGS & OEM SPECTROMETERS OPTICAL COMPONENTS RAMAN

Specifications. Offers the best spatial resolution for multi-stripe spectroscopy. Provides the user the choice of either high accuracy slit mechanism

LED Tester BTS256-LED

Product tags: VIS, Spectral Data, Color Temperature, CRI, Bilirubin, PAR, Scotopic, Luminous Color, Photometry, General lighting

Instruction manual for Ocean Optics USB4000 and QE65 Pro spectroradiometers

MICRO SPECTRAL SCANNER

Microscope-Spectrometer

The only simultaneous absorbance and f uorescence system for water quality analysis! Aqualog

BTS2048-VL-CP-ILED-B-IS-1.0-HL

MUSKY: Multispectral UV Sky camera. Valentina Caricato, Andrea Egidi, Marco Pisani and Massimo Zucco, INRIM

pco.1600 cooled digital 14bit CCD camera system

Camera Overview. Digital Microscope Cameras for Material Science: Clear Images, Precise Analysis. Digital Cameras for Microscopy

12/02/2017. From light to colour spaces. Electromagnetic spectrum. Colour. Correlated colour temperature. Black body radiation.

FPM(L)-NIR(1100) Content PRODUCT SPECIFICATION

A Spectral Database of Commonly Used Cine Lighting Andreas Karge, Jan Fröhlich, Bernd Eberhardt Stuttgart Media University

Ultimate and Versatile 2D Spectroradiometer is finally released!

INTERFEROMETER VI-direct

"SIMPLE MEASUREMENT, ADVANCED RESULTS"

Camera Overview. Digital Microscope Cameras for Material Science: Clear Images, Precise Analysis. Digital Cameras for Microscopy

RGB Laser Meter TM6102, RGB Laser Luminance Meter TM6103, Optical Power Meter TM6104

REPLICATING HUMAN VISION FOR ACCURATE TESTING OF AR/VR DISPLAYS Presented By Eric Eisenberg February 22, 2018

In sum the named factors cause differences for multicolor LEDs visible with the human eye, which can be compensated with color sensors.

Instructions for the Experiment

QE65000 Spectrometer. Scientific-Grade Spectroscopy in a Small Footprint. now with. Spectrometers

Optical In-line Control of Web Coating Processes

Morris Products 53 Carey Road, Queensbury, NY 12804

Quantitative Hyperspectral Imaging Technique for Condition Assessment and Monitoring of Historical Documents

LED Lighting for Machine Vision

WHITE PAPER. Guide to CCD-Based Imaging Colorimeters

ELEC Dr Reji Mathew Electrical Engineering UNSW

Lumen lm 1 lm= 1cd 1sr The luminous flux emitted into unit solid angle (1 sr) by an isotropic point source having a luminous intensity of 1 candela

Oriel MS260i TM 1/4 m Imaging Spectrograph

LATAB Industrial LED Lighting

Color appearance in image displays

Specifications Summary 1. Array Size (pixels) Pixel Size. Sensor Size. Pixel Well Depth (typical) 95,000 e - 89,000 e -

Properties of LED considering museum lighting

GL spectis 1.0 Touch The world s first smart spectrometer.

Camera Requirements For Precision Agriculture

TOP 200. Telescopic Optical Probe for Radiance and Luminance Measurements. Two Global Leaders. One Complete Solution.

CAMAG TLC VISUALIZER 2

Chameleon Spectroradiometer

Laser Speckle Reducer LSR-3000 Series

Color and Image Characterization of a Three CCD Seven Band Spectral Camera

X-ray generation by femtosecond laser pulses and its application to soft X-ray imaging microscope

X-SCOPE Ultra large FOV micro video colorimeter

Lecture 2. Electromagnetic radiation principles. Units, image resolutions.

Transcription:

Multispectral imaging device Most accurate homogeneity MeasureMent of spectral radiance UMasterMS1 & UMasterMS2 ADVANCED LIGHT ANALYSIS by

UMaster Ms Multispectral Imaging Device UMaster MS Description Multispectral imaging systems generate different images of the same object at different wavelengths. Compare to color imaging this technique is much more powerful avoiding metamerism problems and analyzing in depth the light emission properties of any object. Until now, this technology has been limited to select military, medical and scientific applications. Indeed, absolute measurements are quite difficult to obtain using most of these techniques. We present here a system that allows absolute multispectral measurements in the visible range with excellent accuracy. UMaster MS includes a true 16-bit Peltier cooled CCD camera, different filter wheels with band pass filters and imaging objective telecentric on sensor side. Colorimetry & Multispectral Photograph of Umaster MS High accuracy ELDIM is manufacturing on its own all the key components of its systems. The quality of the optics is optimum thanks to advanced technologies such as magneto-rheological polishing or stitching interferometry. Antireflective coatings and optical alignments are performed in house to reduce straight light. The imaging objective is telecentric on the sensor side which ensures same light collection efficiency at each distance and the same transmittance in all the imaging field for the band pass filters. High sensitivity Peltier cooled CCD sensor with true 16-bit analog digital converter allows optimum sensitivity for UMaster MS. Large size CCD versions can be used to detect very low light levels while maintaining a good resolution. High dynamic Additional neutral densities are available to allow measurements of very bright sources. Band pass filter wheel of UMaster MS high wavelength resolution & Nir UMaster MS uses high quality band pass filters. Two wavelength resolutions are available (10nm for MS1 and 20nm for MS2). All the visible wavelength range is covered (400-700nm). Near infrared filters up to 950nm can be available on request. A range of imaging objectives UMaster MS is available with an objective of 8 aperture. Additional optics for high spatial resolution are also available. Transmittance of 31 band pass filters 2

Multispectral Imaging Device UMaster Ms Data analysis and software Each UMaster system comes with a powerful, Windows-based software suite created by ELDIM. This software provides extensive instrument control, data acquisition and image analysis capabilities. The software provides also a simple, user-friendly interface to fully automated, pre-programmed capabilities. This enables each customer to perform sophisticated measurements and tests in a completely automated way with limited efforts. UMaster provides a number of tools to analyze completely the multispectral measurements. Luminance and color maps can be computed easily. Spectral information at any position on the image can be extracted and average on small zones is possible. Dedicated algorithms for display analysis are available such as contour extraction, Moiré removal and LED detection and integration. The captured images can be immediately analyzed with comprehensive, integrated graphs, charts and spreadsheets for: Radiance Luminance Color Illuminance Luminous Intensity Total Luminous Flux Irradiance Radiant Intensity Total Radiant Flux CIE Chromaticity Coordinates (x,y, u,v and a,b) Correlated Color Temperature (CCT) Contrast ratio Data and graphs can be easily exported to other Windows applications. Test Card color image on LCD Test Card luminance image on LCD Test Card radiance image on LCD Spectral data on 5 spots Spectral analysis of color checker Spectral data along horizontal Analysis with spot s 3

UMaster Ms Multispectral Imaging Device 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 color checker color checker illuminated with white LED Spectral reflectance Absolute spectral reflectance is require in many situations. Combined with a stabilized white source UMaster MS can provide easily absolute spectral reflectance in the visible range of any object. Accuracy of the system has been checked using a color checker with 24 different zones of well controlled color and spectral reflectance. The measurement is made using a stabilized white LED illumination. The non-homogeneity of the illumination is corrected making the same measurement on a white reference. The spectral reflection of each zones is then computed taking white zone (19) as reference. Some results are reported hereafter compared to the theoretical spectral reflectance provided by the color checker constructor. Agreement is excellent is quasi all the cases. Spectral reflectance of the different zones (points) compared to theoretical spectra (lines): zone 19 (white) is taken as reference. Z value: 459.7nm Z value: 537.0nm Z value: 609.0nm Spectral reflectance at three different wavelengths 4

Multispectral Imaging Device UMaster Ms Radiance of blue LEDs at 459nm LEDWall analysis Due to statistic LED emission dispersion, all LEDWall tiles generally require a colorimetric calibration. This can done using color measurements of each type of LED (generally blue, green and red). Automated procedure have been developed for ELDIM UMaster videocolorimeter. UMaster MS allows more in depth analysis of LEDWall emission. Emission spectra of each LED can be measured directly and mean wavelength emission λ m and wavelength band pass Δλ m can be deduced. For the multispectral imaging measurement, each emission spectrum is extracted and adjusted using a Pearson VII law: M is a shape parameter that is fixed to 1.6 for LED emission spectra. Detailed emission properties of one LEDWall tile can be deduced. In addition to allow luminance and color correction spectral information are useful to understand and reduce the emission imperfections. Correlation between mean wavelength and wavelength band pass for the 1024 blue LEDs of a tile. Emission peak adjustment of blue LED using Pearson VII model Mean wavelength and wavelength band pass for all the blue LEDs of a tile 5

UMaster Ms Multispectral Imaging Device Reflective display & aspect UMaster MS can provide full spectral characterization of reflective displays. Global spectral reflectance homogeneity can be checked. The display image aspect can be also predicted under any illumination conditions. Color Measurement of blue state on Ipod display Homogeneity of reflectance at 523nm on IPod display Spectral reflectance homogeneity UMaster MS is capable to provide high spatial resolution spectral information and not only luminance and color measurements. On reflective displays and after normalization with a measurement on a white reference under the same illumination conditions, the spectral reflectance homogeneity can be checked. Diffusion defects can be also easily detected. Image aspect under various illuminants Absolute spectral reflectance for a given image using the reflective display can be measured. Then the display aspect with this image and any type of illumination can be calculated and predicted. 450nm Original image Resulting color image under D65 illumination 550nm Resulting color image under A illumination 650nm Normalized reflectance image for each wavelength Spectral image & selection zone 6

Multispectral Imaging Device UMaster Ms UMaster MS comes with a complete software solution for measurement and data analysis. Some characteristics of the EZCom 6 software package for UMaster MS Features Measurement Capacities Data analysis Data export Programming capacities Imaging Radiance Color & Luminance computation Details Color unit: xy, u v, Lu*v* or La*b* Color intensity, Color Difference, Color Dispersion, Color Triangle, Color Temperature, Equivalent Wavelength Cross section (Horizontal, Vertical and free), Isocurves, False Color representation, 3D representation, Smoothing Filtering, Rotation, Clipping, R.O.I. extraction, Averaging, Contour extraction, Moiré removal Spectral reflectance calculation and color computation for any illuminant Average and extraction on rectangular or circular zones Copy to clipboard Save in text and excel format Multi-spots statistics All features can be controlled by OCX interface Examples of automated measurements and analysis provided 7

UMaster Ms Multispectral Imaging Device Major specifications of UMaster MS1 & MS2 Common specifications MS1 MS2 Options Imaging lens Front entrance iris Telecentric on sensor Motorized focusing Diameter Other diameters Max 8 Software adjustment 6mm from 2mm to 10mm Additional optics For high spatial resolution (only available for 1.6M pixel sensor) x1 x2 x4 Radiance Band pass Flters from 400 to 700nm Additional NIR filters 31 2 16 6 Densities To add on the imaging objective From ND1 to ND4 Sensor configuration Monochrome Peltier cooled CCD grade 1 1500x1000 or 1.6M pixels 2000x2000 or 4M pixels Radiance Range Accuracy Repeatability Radiance Luminance Chromaticity (x,y) RMS Radiance Luminance Chromaticity 0.001 to 500Cd/m 2 up to 125 000Cd/m 2 with ND filters ±3% (*1) ±3% for any color stimulus (*2) ±0.003 for A type illuminant (*2) ±0.005 for any color stimulus (*2) ±0.5% for full resolution (*1*3) ±0.5% for full resolution (*1*3) 0.001 for full resolution (*1*3) Measurement time Radiance <3mn (*4) <90s (*4) Using conditions Temperature range Humidity range 0 to 40 C 0-85% non condensing Interface Compute controlled by OCX components USB 2.0 Power Independent Power Supply AC adapter (100-240V 50/60Hz) Current consumption 90W Weight 9Kg (*1) For a radiance level higher than 10mW/Sr/m 2 / nm (*2) The accuracy is guarantied for any type of color stimuli in contrast to competitors that generally guaranty only reference white. (*3) The repeatability is given for full resolution. When a binning level N is used it is divided by a factor of N 2. With standard CCD sensor and for a resolution of 375x250 the radiance repeatability is only ±0.03%! (*4) Measurement times are highly dependent on the target and on the conditions. Given times are for a source with a radiance level higher than 10mW/Sr/m 2 /nm at all the wavelengths and already determined optimized exposure times for all the filters. Outer dimension (unit mm) RA-025 V1.0 09/2009 ELDIM S.A. 8 POLYTEC GmbH Polytec-Platz 1-7 D -76337 Waldbronn GERMANY Tel: +49 (72 43) 604-1540 Fax: +49 (72 43) 69944 E-Mail: osm@polytec.de www.polytec.de