MEC MEC C Wall-mounted air heaters for indoor installation

Similar documents
RS /E-EV BLU SERIES

KCR-R CONSTANT AIR VOLUME FLOW REGULATOR

RS /E-EV BLU SERIES

RS /E-EV BLU SERIES

RS /M MZ SERIES

MODUBLOC MB SE SERIES

GI/EMME SERIES

Electromagnetic Flow Transmitter

Actuators Series 8602/3

RS /M MZ Series. Modulating Gas Burners GAS TECHNICAL DATA LEAFLET

SIT Group FLUE SYSTEMS

GE Monogram. Installation. Instructions. 36" Vent Hood. Model ZV750. Call anywhere in the US and Canada -

CONTROL Room. Room product for Swegon s WISE system for demand-controlled ventilation. Quick facts Room control against temperature, CO 2

University of Houston Master Construction Specifications Insert Project Name SECTION MECHANICAL SCOPE OF WORK PART 1 - GENERAL

MR Modulo Adjustable Constant Airflow Regulator

RS /M BLU Series

U1500E Gas Fireplace

Digital flow transmitter for continuous flow measurement

Control panel touch screen MOD. 80

Technical Manual Modulation Box

Installation Guide. Model #400. Corporate Office: 349 Highland Road East Macedonia, Ohio

Compact. Pre-Installation guide. Video. Complete Walkthrough. Scanomat Download Center. Scanomat Connection Diagram

Tangential Fans - Basic principles. Expertise, performance, innovation

SPLIT DUCTED UNIT TECHNICAL SELECTION DATA SRA141C / SRA140E SPECIFICATION SUMMARY UNIT FEATURES CONTROL FEATURES CONTROL OPTIONS. PLENUMS (Optional)

Contemporary Collection

VERTICAL BALANCED FLUE SYSTEM INSTALLATION INSTRUCTIONS

Digital flow ELEMENT transmitter for continuous flow measurement

Jabiru Installation instructions

Valve Island with Electronic I/O

INSERTION paddle wheel flowmeter for continuous flow measurement

CLASSIC 300D Kubota PARTS LIST FOR RETURN TO MAIN INDEX

Ultrasonic level transmitter, non-contact

Installation Instructions

Repair Parts List DRYER MODEL NUMBER LDGA300AGE. When requesting service or ordering parts, always provide the following information:

BLOWERS TRL /FRL/FEA

COMPACT CASSETTE TYPE AIR CONDITIONER

Digital inductive conductivity transmitter

Description The aerodynamic shape of the Kongskilde blower ensures high efficiency and low energy consumption.

ROTARY HAMMER OWNER S MANUAL

INLINE flowmeter for continuous flow measurement

ABSOLUTE ROTARY ENCODER MULTI-TURN BIT PARALLEL

Base Mounted Plug-in Unit

HEARTH PRODUCTS KITS AND ACCESSORIES VERTICAL TERMINATION KITS FOR SECURE FLEX VERTICAL VENTING

PLASTIC PIPE WELDING PLASTIC PIPE WELDING

Digital flow ELEMENT transmitter for continuous flow measurement

Item Checklist & Additional Tools Required For Installation

contemporary gas fireplaces

Contemporary Collection

Zero Clearance Fireplace 44 ELITE-ZC INSTALLATION MANUAL. Listed Tested to: U.L. 127 and portions of U.L & 907. Part # $10.

Small Duct Systems. Product Catalogue. 1

GB/GW GB/GW GB/GW GB/GW

Installation instructions for oil unit CADDY FURNACE PA03050 and PA03100

Zero Clearance Fireplace 36 ELITE-ZC INSTALLATION MANUAL. Listed Tested to: U.L. 127 and portions of U.L & 907. Part # $10.

Never fill any required clearance space with insulation or any other building materials surrounding the chimney.

INLINE flowmeter for continuous flow measurement

Type PLC Fitting. Valve for Continuous control. Diaphragm valve. Output

CATALOG OF REPLACEMENT PARTS GAS CONVECTION STEAMERS MODELS

Kitchen exhaust fan GLEB

Installation Instructions

D300K 3+3 SE KUBOTA PARTS LIST FOR RETURN TO MAIN INDEX

INLINE flowmeter for continuous flow measurement

60/100 Concentric Flue System Parts

B-Too Drilling and Tapping Machine Instruction and Maintenance Manual

Omnidirectional Antenna Vertical Polarization Indoor and outdoor use

Differential pressure sensors

CONTROL UNITS. VEHICLE EXHAUST GASES Pure advantages VEHICLE EXHAUST GASES

BUILDING PLAN REVIEW REQUIREMENTS

FS-7006PA FS-7012PA YA-7000 POWER AMPLIFIERS. AMPLIFIER AUTO SWITCHING MODULE (Optional) OPERATING INSTRUCTIONS

RS/E MZ Series. Technical Data Leaflet. Modulating Gas Burners. Gas TS0088UK00

Room Temperature Controllers. for heating and cooling systems

Digital flowmeter for continuous flow measurement

FD 125 Large-Format Card Cutter

Manual FOR YOUR SAFETY. Do not store or use gasoline or other flammable vapours and liquids in the vicinity of this or any other appliance.

Digital flowmeter for continuous flow measurement

Integrate the Window and WRB (1/2)

KR703-XE KR704-XE KR705-XE KR753-XE KR754-XE KR755-XE Australia New Zealand

This FDB2 has been customized with the following options: NORSOK flanges, control enclosure, ATEX certified components and steel tubing

HOLE CUTTER SHARPENER ASSEMBLY & SERVICE MANUAL

Repair Parts List REFRIGERATOR MODEL NUMBER MANUFACTURING NUMBER P W

Current / residual current and voltage transformers. Current / residual current and voltage transformers

ASG SUCTION CUPS FOR DRY DRILLING AND WET DIAMOND CORE DRILLING

MBC /602(L) MBC /602(L) MBC /602(L)

Installation Manual. This installation is for the Odyssey H1800 Series Ventilation System.

Hydraulic Clamping Systems

7. Operating instructions: EFL 300

INSTALLATION MANUAL. Decoration panel BYCQ140E2W1 BYCQ140E2W1W BYCQ140E2W1B

Installation and Maintenance Manual IM 770-1

TITGEMEYER Tf1673GB(0517)1. GETO City Body Kit with a self-supporting base and without a base Assembly Instructions

Volumetric flow controller

RoHS. High shaft load capacity. Shock / vibration resistant

This manual applies to the WT-RC-Ex receiver when used to locate all makes and models of 22 Hz and Wavetrak coded transmitters.

Code. Edition 04/2013. CPA Screw Air Compressors. Parts List Book

INSTALLATION MANUAL PBC-UMS

0Introduction. TECHNICAL DOCUMENTATION 20/02/2009 PRESSURE Brake pressure PSI

R PROFLAME Instruction Book Collection

Merloni Elettrodomestici. Technical Fitting Manual FRIDGE. Language Issue/Edition Page GB /

gas fireplace inserts

M1.0 MECHNANICAL FLOOR PLAN

Number Wheeler P/N Description Set Rex P/N Notes Base 1 J Support, Right 1 J Support, Left 1 J Nut (M8)

Product Data Sheet RG160-28/18N/2TDPU-331

Transcription:

mod. MEC mod. MEC C Model Heat Input Heat Output Code MEC 25 25,00,90 30120000 3.000,00 MEC 35 300000 3.080,00 MEC 50 50,00 45,30 30270000 4.0,00 MEC 57 30320000 4.710,00 MEC 85 30370000 6.740,00 MEC 35 C ducted 30230000 3.640,00 MEC 57 C ducted 30330000 5.670,00 MEC 85 C ducted 30380000 7.920,00 160

Accessoires MEC 25 85 - MEC 35 85 C Remote control with the following functions: on/off switch, electronic room temperature thermostat, run and warning lights, reset button, suer ventilation selector cable 4 m cable 10 m Code 30170010 234,00 30170015 266,00 Weekly prograable thermostat with integrated GSM 362052 550,00 Exhaust sampling plug 30170057 15,00 Wall horizontal exhaust kit exhaust duct Ø 80 MEC 25 35; Ø MEC 50 85) length cm, clamp and gasket, external duct end mod. 25 35 mod. 50 85 30170050 110,00 30320050 152,00 Air intake kit duct Ø 140 length cm 50 with external duct end, flexible pipe Ø 140 length 3 m, 2 clamps, sampling plug for 25 85 30170040 106,00 Roof-tile of plastic for fireplace Slanted roof from 5 to 30 Griglia di mandata aria supplementare con alette verticali orientabili mod. 25 35 mod. 50 57 30351010 84,00 30171501 138,00 30321501 234,00 30371501 296,00 Ducts and elbows for exhaust flue extension (Ø 80 MEC 25 35) (Ø MEC 50 85) duct m 1 Ø 80 duct m 1 Ø elbow 90 Ø 80 elbow 90 Ø curva 45 Ø 80 elbow 45 Ø elbow with condensate drain Ø 80 elbow with condensate drain Ø 37800035 72,00 37800050 80,00 37800030 58,00 37800031 70,00 37800032 66,00 37800034 70,00 37800037 82,00 37800039 78,00 Roof exhaust flue exhaust duct (Ø 80 MEC 25 35; Ø MEC 50 85) length cm, clamp and gasket, external duct end, plastic rain-proof cap with gasket and clamp mod. 25 35 mod. 50 85 30170055 308,00 30320055 276,00 Holders mod. 25 35 axial mod. 50 85 centrifuge 30240090 110,00 30150090 120,00 Air intake duct coupling 301721 190,00 3031 254,00 303721 340,00 161

Accessori MEC 35 85 C Ducting vibration damper Codice 301730 212,00 303230 318,00 303730 380,00 Duct coupling with air ejection outlet to be combined with fire damper 301725 508,00 3035 594,00 303725 678,00 Fire damper REI 120 for ducting 301705 1.060,00 303205 1.166,00 303705 1.484,00 Air delivery grate with two rows of adjustable flaps 301710 340,00 303210 424,00 303710 614,00 Type of installation Type C12 The combustion circuit is air-tight and sealed off from the environment. The ducts cross the outside wall directly, with terminals included, throughout a square of 50 x 50 cm. Installation includes the following accessories: - horizontal wall exhaust kit - kit Top view Type C52 The combustion circuit is air-tight and sealed off from the environment. Both ducts are connected to the outside, but their terminals may be situated on different walls of the room. Installation is carried out by using the following accessories: horizontal wall exhaust kit - kit - 90 elbow Ø 80 with condensate drain - roof exhaust terminal kit - duct length m 1 Ø 80 - lead roof-tile Top view Type B The combustion circuit is air-tight and sealed off from the environment. Both ducts are connected to the outside, but their terminals may be situated on different walls of the room. Installation is carried out by using the following accessories: horizontal wall exhaust kit - kit - 90 elbow Ø 80 with condensate drain - roof exhaust terminal kit - duct length m 1 Ø 80 - lead roof-tile 162

Examples of installations MEC C Examples of installations MEC C MEC 25 85 - MEC 35 85 C Aeration opening for methane use Aeration opening for methane use Serranda di espulsione Fire damper Room (where permitted) Aeration opening for LPG use Fire damper Room (where permitted) Aeration opening for LPG use Installation of a MEC C unit in a room next to the room to be heated Note: Kits and accessories for combustion duct and exhaust flue extension are the same as for series MEC. of a MEC 35 C unit installed inside the room with ducted air delivery, insertion of vibration damper and fully indoor. Installation carried out by using the following accessories: - vibration damper for ducting - holders Installation of a MEC C unit inside an heater room located inside the buiding, next to the room to be heated Installation of a MEC C unit inside an heater room located outside the building of a MEC 35 C unit installed with polyethylene duct coupled to the unit. Installation carried out by using the following accessories: - circular section coupling for air delivery polyethylene duct - perforated polyethylene duct Ø 400, length 25 m - holders - 107 - Dimensions MEC 25-35 A 695 I 93 B 415 L 528 D 477 E 470 G 120 H 695 N 283 Q 62 R 48 T 76 U 398 Exhaust Ø 80 Dimensions MEC 50-57 A 1147 I 93 B 415 L 528 D 477 E 9 G 113 H 684 N 290 Q 62 R 48 T 81 U 840 163

Dimensions MEC 85 A 1748 I 874 B 480 L 133 C 870 D 542 E 1358 G 1133 H 715 N 353 O 515 Q 62 R 48 T 424 U 900 Dimensions MEC 35 C A 695 B 415 I 93 L 528 T 76 U 398 D 797 N 283 E 440 G 120 Q 382 H 695 R 48 Dimensions MEC 57 C A 1147 B 415 I 93 L 528 T 81 U 840 D 797 N 290 E 9 Aria Ø 140 G 113 Q 382 H 684 R 48 Dimensions MEC 85 C A 1748 I 874 B 480 L 133 T 424 C 870 U 900 D 862 N 353 E 1350 O 515 G 1133 Q 382 H 715 R 48 164

Technical datasheet MEC 25 85 Description Heat Output Heat Input Gas flow rate min-max (15 C - 1.013 ) Burner gas pressure (15 C - 1.013 ) Nozzles diameter Gas supply connection Air intake diameter Exhaust flue diameter Power supply Air flow rate Revolution per minute Air throw Air temperature rise Noise level (at 5 m) Electrical power input Fuse Net weight Methane G20 Butane G30 Propane G31 G20 p 20 G30 p 28-30 G31 p 37 G20 G30/G31 U.M. / / n. m C db(a) W A Kg MEC 25,90 25,00 2,65 1,97 1,94 10,0 27,7 36,5 310 175 2 1095 16 33 45,0 175 64 80 MEC 35 3,70 2,76 2,71 12,0 27,4 36,0 350 210 2500 1370 37 49,5 215 64 MEC 50 43,50 50,00 5,29 3,94 3,88 10,4 24,2 350 185/240 G 1/2 140 230V/1/50Hz 4600 1260 30 50,5 380 4 64 MEC 57 6,03 4,49 4,42 10,5 24,2 370 0 5000 1350 31 52,5 400 106 MEC 85 9,00 6,70 6,60 11,0 25,0 400 240 7400 1335 30 54,3 530 180 Technical datasheet MEC 25 85 C Description Heat Output Heat Input Gas flow rate min-max (15 C - 1.013 ) Burner gas pressure (15 C - 1.013 ) Nozzles diameter Gas supply connection Air intake diameter Exhaust flue diameter Power supply Air flow rate Revolution per minute Air throw Air temperature rise Noise level (at 5 m) Electrical power input Fuse Net weight Methane G20 Butane G30 Propane G31 G20 p 20 G30 p 28-30 G31 p 37 G20 G30/G31 U.M. / / n Pa C db(a) W A Kg MEC 35 C 3,70 2,76 2,71 12,0 27,4 36,0 350 210 80 2500 930 37 48,5 580 6,3 73 MEC 57 C 6,03 4,49 4,42 10,5 24,2 370 0 G 1/2 140 230V/1/50Hz 5000 930 31 51,5 1050 10,0 125 MEC 85 C 9,00 6,70 6,60 11,0 25,0 400 240 7300 950 31 53,0 1550 15,0 207 165