VCCI TEST REPORT According to V-3/2009.04, TECHNICAL REQUIREMENTS, Class B ITE Equipment : USB video camera Model No. : V-U0017 / V-U0021 Applicant : Logitech Far East Ltd. 2 Creation Road IV, Science-Based Ind. Park, Hsinchu, Taiwan. The test result refers exclusively to the test presented test model / sample. Without written approval of SPORTON International Inc., the test report shall not be reproduced except in full. SPORTON International Inc. 6F, No. 106, Sec. 1, Hsin Tai Wu Rd., Hsi Chih, Taipei Hsien, Taiwan, R.O.C. SPORTON International Inc. TEL : 886-2-2696-2468
Table of Contents History of this test report...ii CERTIFICATE OF COMPLIANCE...1 1. General Description of Equipment under Test...2 1.1. Applicant...2 1.2. Manufacturer...2 1.3. Basic Description of Equipment under Test...2 1.4. Feature of Equipment under Test...2 2. Test Configuration of Equipment under Test...3 2.1. Test Manner...3 2.2. Description of Test System...3 2.3. Connection Diagram of Test System...4 3. Test Software...6 4. General Information of Test...7 4.1. Test Facility...7 4.2. Test Voltage...7 4.3. Measurement Procedure...7 4.4. Test in Compliance with...7 4.5. Frequency Range Investigated...7 4.6. Test Distance...7 5. Test of Conducted Powerline...8 5.1. Description of Major Test Instruments...8 5.2. Test Procedures...8 5.3. Typical Test Setup Layout of Conducted Powerline...9 5.4. Test Result of AC Powerline Conducted Emission...10 5.5. Photographs of Conducted Powerline Test Configuration...12 6. Test of Radiated Emission...13 6.1. Description of Major Test Instruments...13 6.2. Test Procedures...15 6.3. Typical Test Setup Layout of Radiated Emission...16 6.4. Test Result of Radiated Emission...17 6.5. Photographs of Radiated Emission Test Configuration...23 7. List of Measuring Equipment Used...25 8. Certificate of VCCI...26 Appendix A. Photographs of EUT... A1 ~ A15 SPORTON International Inc. Page Number : i
History of this test report Original Report Issue Date: Jun. 23, 2010 No additional attachment. Additional attachment were issued as following record: Attachment No. Issue Date Description SPORTON International Inc. Page Number : ii
1. General Description of Equipment under Test 1.1. Applicant Logitech Far East Ltd. 2 Creation Road IV, Science-Based Ind. Park, Hsinchu, Taiwan. 1.2. Manufacturer Same as 1.1 1.3. Basic Description of Equipment under Test Equipment Model No. Trade Name Power Supply Type : USB video camera : V-U0017 / V-U0021 : Logitech : From Host System USB Cable : Shielded, 1.45m 1.4. Feature of Equipment under Test The model names in the following table are all refer to the identical product. Model Name V-U0017 V-U0021 Description All the models are identical, the difference model served as marketing strategy. Please refer to user manual. SPORTON International Inc. Page Number : 2 of 27
2. Test Configuration of Equipment under Test 2.1. Test Manner a. During testing, the interface cables and equipment positions were varied according to Implementation Regulation for the Voluntary Control of Radio Interference by Data Processing Equipment and Electronic Office Machines. b. Only V-U0017 was performed for all the tests and recorded in this report. c. The complete test system included DELL Notebook, icooky Mouse and EUT for EMI test. d. Frequency range investigated: Conduction 150 KHz to 30 MHz, Radiation 30 MHz to 2000MHz. 2.2. Description of Test System Support Unit 1. -- Notebook (DELL) FCC ID Model No. Power Supply Type Power Cord Serial No. : E2K4965AGNM : PP25 : Switching : Non-Shielded : NB-O Support Unit 2. -- Mouse (icooky) FCC ID : N/A Model No. : AMS0706W Serial No. : MO-A Data Cable : Shielded, 1.8m Remark : This support device was tested to comply with FCC standards and authorized under a declaration of conformity. SPORTON International Inc. Page Number : 3 of 27
2.3. Connection Diagram of Test System 2.3.1. AC Power Line Conduction Emissions Test Configuration AC MAIN 1 3 ADAPTER 1 DC RS232 RJ-11 USB LPT VGA Notebook USB x 2 EUT 2 1. POWER CABLE, 260 CM, NON-SHIELDED 2. USB CABLE, 180 CM, SHIELDED 3. USB CABLE 145 CM, SHIELDED MOUSE SPORTON International Inc. Page Number : 4 of 27
2.3.2. Radiation Emissions Test Configuration AC Main 2 3 EUT RJ-11 RJ-45 LPT PS/2 VGA DC USB x 2 Notebook 1 1.USB CABLE 180CM, SHIELDED 2.POWER CABLE 260CM, NON-SHIELDED 3.USB CABLE 145CM, SHIELDED Mouse SPORTON International Inc. Page Number : 5 of 27
3. Test Software An executive program, EMCTEST.EXE under WIN XP, which generates a complete line of continuously repeating H pattern was used as the test software. a. Turn on the power of all equipment. b. The NB sends H messages to the panel, and the panel displays H patterns on the screen. At the same time, Logitech Webcam was executed to display the capturing image from EUT. SPORTON International Inc. Page Number : 6 of 27
4. General Information of Test 4.1. Test Facility Test Site Location Test Site No. : No.8, Lane 724, Bo-ai St., Jhubei City, Hsinchu County 302, Taiwan, R.O.C. TEL : 886-3-656-9065 FAX : 886-3-656-9085 : Conduction : CO01-CB; Radiation : 10CH01-CB 4.2. Test Voltage 100V / 50Hz 4.3. Measurement Procedure Implementation Regulation for the Voluntary Control of Radio Interference by Data Processing Equipment and Electronic Office Machines. 4.4. Test in Compliance with V-3/2009.04, TECHNICAL REQUIREMENTS, Class B ITE 4.5. Frequency Range Investigated a. Conducted emission test: from 150 khz to 30 MHz b. Radiated emission test: from 30 MHz to 2,000 MHz 4.6. Test Distance a. The test distance of radiated emission test from antenna to EUT is 10 m (from 30MHz~1000MHz). b. The test distance of radiated emission from antenna to EUT is 3 m (from 1GHz~2GHz). SPORTON International Inc. Page Number : 7 of 27
5. Test of Conducted Powerline Conducted Emissions were measured from 150 khz to 30 MHz with a bandwidth of 9 khz and return leads of the EUT according to the methods defined in Implementation Regulation for the Voluntary Control of Radio Interference by Data Processing Equipment and Electronic Office Machines, Section 3.1. The EUT was placed on a nonmetallic stand in a shielded room 0.8 meters above the ground plane as shown in section 5.3. The interface cables and equipment positioning were varied within limits of reasonable applications to determine the position producing maximum conducted emissions. 5.1. Description of Major Test Instruments Test Receiver (R&S ESCS 30) Attenuation Start Frequency Stop Frequency IF Bandwidth 10 db 0.15 MHz 30 MHz 9kHz 5.2. Test Procedures a. The EUT was placed on a desk 0.8 meters height from the metal ground plane and 0.4 meter from the conducting wall of the shielding room and it was kept at least 0.8 meters from any other grounded conducting surface. b. Connect EUT to the power mains through a line impedance stabilization network (LISN). c. All the support units are connect to the other LISN. d. The LISN provides 50 ohm coupling impedance for the measuring instrument. e. The CISPR states that a 50 ohm, 50 microhenry LISN should be used. f. Both sides of AC line were checked for maximum conducted interference. g. The frequency range from 150 khz to 30 MHz was searched. h. Set the test-receiver system to Peak Detect Function and Specified Bandwidth with Maximum Hold Mode. SPORTON International Inc. Page Number : 8 of 27
5.3. Typical Test Setup Layout of Conducted Powerline 10 cm 80 cm to the ground plane L.I.S.N. L.I.S.N. SPORTON International Inc. Page Number : 9 of 27
5.4. Test Result of AC Powerline Conducted Emission Frequency Range of Test: from 0.15 MHz to 30 MHz Temperature: 22.3 Relative Humidity: 52.3 % All emissions not reported here are more than 10 db below the prescribed limit. Corrected Reading (dbuv) = LISN Factor + Cable Loss + Read Level = Level The test was passed at the minimum margin that marked by the frame in the following table Line SPORTON International Inc. Page Number : 10 of 27
Neutral Test Engineer : Aric Li SPORTON International Inc. Page Number : 11 of 27
5.5. Photographs of Conducted Powerline Test Configuration The photographs show the configuration that generates the maximum emission. FRONT VIEW REAR VIEW SPORTON International Inc. Page Number : 12 of 27
6. Test of Radiated Emission Radiated emissions from 30 MHz to 2,000 MHz were measured with a bandwidth of 120 khz for 30 MHz to 1000 MHz and 1 MHz for above 1GHz according to the methods defines in implementation Regulation for the Voluntary Control of Radio Interference by Data Processing Equipment and Electronic Office Machines. The EUT was placed on a nonmetallic stand, 0.8 meter above the ground plane, as shown in section 6.3. The interface cables and equipment positions were varied within limits of reasonable applications to determine the positions producing maximum radiated emissions. 6.1. Description of Major Test Instruments 6.1.1. 30MHz~1GHz Amplifier (Agilent 8447D) RF Gain 25 db Signal Input 9 KHz to 1.3 GHz Spectrum Analyzer Attenuation Start Frequency Stop Frequency Resolution Bandwidth Signal Input (R&S FSP40) 10 db 30 MHz 1000 MHz 120 KHz 9 KHz to 40 GHz Test Receiver Attenuation Start Frequency Stop Frequency Resolution Bandwidth Signal Input (R&S ESCI) 10 db 30 MHz 1000 MHz 120 KHz 9kHz to 3 GHz SPORTON International Inc. Page Number : 13 of 27
6.1.2. Above 1GHz Amplifier (Agilent 8449B) RF Gain Signal Input 35 db 1GHz 26.5 GHz Spectrum Analyzer Attenuation Start Frequency Stop Frequency Resolution Bandwidth Video Bandwidth Signal Input (R&S FSP40) 10 db 1 GHz 18 GHz 1 MHz 1 MHz 9 khz 40 GHz SPORTON International Inc. Page Number : 14 of 27
6.2. Test Procedures a. The EUT was placed on a rotatable table top 0.8 meter above ground. b. The EUT was set 3/10 meters from the interference-receiving antenna which was mounted on the top of a variable height antenna tower. c. The table was rotated 360 degrees to determine the position of the highest radiation. d. The antenna is a half wave dipole and its height is varied between one meter and four meters above ground to find the maximum value of the field strength both horizontal polarization and vertical polarization of the antenna are set to make the measurement. e. For each suspected emission the EUT was arranged to its worst case and then tune the antenna tower (from 1 m to 4 m) and turn table (from 0 degree to 360 degrees) to find the maximum reading. f. Set the test-receiver system to Peak Detect Function and specified bandwidth with Maximum Hold Mode. g. If the emission level of the EUT in peak mode was 3 db lower than the limit specified, then testing will be stopped and peak values of EUT will be reported, otherwise, the emissions which do not have 3 db margin will be repeated one by one using the quasi-peak method and reported. h. For testing above 1GHz, the emission level of the EUT in peak mode was 20dB lower than average limit (that means the emission level in peak mode also complies with the limit in average mode), then testing will be stopped and peak values of EUT will be reported, otherwise, the emissions will be measured in average mode again and reported. SPORTON International Inc. Page Number : 15 of 27
6.3. Typical Test Setup Layout of Radiated Emission Antenna Equipment under Test Test Distance 0.8 M Ground Plane TurnTable Receiver SPORTON International Inc. Page Number : 16 of 27
6.4. Test Result of Radiated Emission Frequency Range of Test: from 30 MHz to 1,000 MHz Test Distance: 10m Temperature: 24 Relative Humidity: 56 % Emission level (dbuv/m) = 20 log Emission level (uv/m) Corrected Reading: Antenna Factor + Cable Loss + Read Level - Preamp Factor = Level The test was passed at the minimum margin that marked by the frame in the following test record Vertical SPORTON International Inc. Page Number : 17 of 27
Vertical SPORTON International Inc. Page Number : 18 of 27
Horizontal SPORTON International Inc. Page Number : 19 of 27
Horizontal Test Engineer : Peter Wu SPORTON International Inc. Page Number : 20 of 27
Frequency Range of Test: from 1000MHz to 2000 MHz Test Distance: 3m Temperature: 24 Relative Humidity: 56 % Emission level (dbuv/m) = 20 log Emission level (uv/m) Corrected Reading: Antenna Factor + Cable Loss + Read Level - Preamp Factor = Level The test was passed at the minimum margin that marked by the frame in the following test record Vertical SPORTON International Inc. Page Number : 21 of 27
Horizontal Test Engineer : Peter Wu SPORTON International Inc. Page Number : 22 of 27
6.5. Photographs of Radiated Emission Test Configuration The photographs show the configuration that generates the maximum emission. Test Configuration: 30MHz~1GHz FRONT VIEW REAR VIEW SPORTON International Inc. Page Number : 23 of 27
Test Configuration: Above 1GHz FRONT VIEW REAR VIEW SPORTON International Inc. Page Number : 24 of 27
7. List of Measuring Equipment Used Instrument Manufacturer Model No. Serial No. Characteristics Calibration Date Remark EMI Test Receiver R&S ESCS 30 100377 9kHz ~ 2.75GHz Jul. 20, 2009 Conduction (CO01-CB) LISN F.C.C. FCC-LISN-50-1 6-2 04083 150kHz ~ 100MHz Apr. 24, 2009 Conduction (CO01-CB) V- LISN Schwarzbeck NSLK 8127 8127-478 9K ~ 30MHz Oct. 30, 2009 PULSE LIMITER R&S ESH3-Z2 100430 9K~30MHz Jan. 04, 2010 Conduction (CO01-CB) Conduction (CO01-CB) 10m Semi Anechoic Chamber TDK SAC-10M 10CH01-CB 30MHz~1GHz 10m, 3m Nov. 16, 2009 Radiation (10CH01-CB) Pre-Amplifier Agilent 8447D 2944A10783 9KHz ~ 1.3GHz Nov. 06, 2009 Pre-Amplifier Agilent 8447D 2944A10784 9KHz ~ 1.3GHz Nov. 06, 2009 Biconical Antenna Schwarzbeck VHBB 9124 324 30MHz ~ 200MHz Nov. 16, 2009 Log Antenna Schwarzbeck VUSLP 9111 247 200MHz ~ 1GHz Nov. 16, 2009 EMI Test Receiver R&S ESCI 100186 9KHZ ~ 3GHz Mar. 09, 2010 Spectrum Analyzer R&S FSP40 100142 9KHz ~ 40GHz Jan. 21, 2010 HIGH CABLE Woken 1.1-1GHz ~ 6GHz Dec.15, 2009 Horn Antenna COM-POWER AHA-118 701105 1GHz~18GHz Sep. 09, 2009 Radiation (10CH01-CB) Radiation (10CH01-CB) Radiation (10CH01-CB) Radiation (10CH01-CB) Radiation (10CH01-CB) Radiation (10CH01-CB) Radiation (10CH01-CB) Radiation (10CH01-CB) Calibration Interval of instruments listed above is one year. SPORTON International Inc. Page Number : 25 of 27
8. Certificate of VCCI SPORTON International Inc. Page Number : 26 of 27
SPORTON International Inc. Page Number : 27 of 27
APPENDIX A. Photographs of EUT SPORTON International Inc. PAGE NUMBER : A1 OF A15 TEL : 886-2-2696-2468 ISSUED DATE : Jun. 23, 2010
SPORTON International Inc. PAGE NUMBER : A2 OF A15 TEL : 886-2-2696-2468 ISSUED DATE : Jun. 23, 2010
SPORTON International Inc. PAGE NUMBER : A3 OF A15 TEL : 886-2-2696-2468 ISSUED DATE : Jun. 23, 2010
SPORTON International Inc. PAGE NUMBER : A4 OF A15 TEL : 886-2-2696-2468 ISSUED DATE : Jun. 23, 2010
SPORTON International Inc. PAGE NUMBER : A5 OF A15 TEL : 886-2-2696-2468 ISSUED DATE : Jun. 23, 2010
SPORTON International Inc. PAGE NUMBER : A6 OF A15 TEL : 886-2-2696-2468 ISSUED DATE : Jun. 23, 2010
SPORTON International Inc. PAGE NUMBER : A7 OF A15 TEL : 886-2-2696-2468 ISSUED DATE : Jun. 23, 2010
SPORTON International Inc. PAGE NUMBER : A8 OF A15 TEL : 886-2-2696-2468 ISSUED DATE : Jun. 23, 2010
SPORTON International Inc. PAGE NUMBER : A9 OF A15 TEL : 886-2-2696-2468 ISSUED DATE : Jun. 23, 2010
SPORTON International Inc. PAGE NUMBER : A10 OF A15 TEL : 886-2-2696-2468 ISSUED DATE : Jun. 23, 2010
SPORTON International Inc. PAGE NUMBER : A11 OF A15 TEL : 886-2-2696-2468 ISSUED DATE : Jun. 23, 2010
SPORTON International Inc. PAGE NUMBER : A12 OF A15 TEL : 886-2-2696-2468 ISSUED DATE : Jun. 23, 2010
SPORTON International Inc. PAGE NUMBER : A13 OF A15 TEL : 886-2-2696-2468 ISSUED DATE : Jun. 23, 2010
SPORTON International Inc. PAGE NUMBER : A14 OF A15 TEL : 886-2-2696-2468 ISSUED DATE : Jun. 23, 2010
SPORTON International Inc. PAGE NUMBER : A15 OF A15 TEL : 886-2-2696-2468 ISSUED DATE : Jun. 23, 2010