RESISTRON RV Operating Instructions. 1 Technical data

Similar documents
RESISTRON RES-402. Operating Instructions. Important features

RESISTRON RES-401. Operating Instructions. Important features

RESISTRON RES-403. Operating Instructions. Important features

CIRUS UPT-6011 GB. Operating instructions. Important features

RESISTRON RES-409. Operating instructions. Important features

RESISTRON UPT-640. Operating Instructions. Important features

10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units

RESISTRON RES-5011 GB. Operating instructions. Important features

VEO. V2PF480Y/277VS01 Art.Nr.: B TECHNICAL DATA

08/07/2015

Electronic timer CT-TGD.22

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

RESISTRON RES-415. Operating Instructions. Important features

Transformers, Power Supply Units and Socket Outlets

RESISTRON RES-5010 GB. Operating instructions. Important features

Control module CP-A CM

Thermistor motor protection relays

Electronic timer CT-SDD.22

Installation and Operational Instructions for ROBA -switch Type 017._00.2

DT1100 E xx xx (PS) Galvanic Isolators. Operating Instructions

Installation and Operational Instructions for ROBA -switch Type 017._00.2

PTC-resistor relay type MS 220 K and MSR 220 K PTC-resistor trip device

Datasheet - PROTECT-IE-02

V2UM230V10 Art.Nr.: V2UM230V10P Art.Nr.: Control elements. Tripping delay. Function selector. Status indication 230 V AC/DC

DT1100 xx xx xx PS. Isolators, Isolator / Power Supplies. Operating Instructions

Installation and Operational Instructions for ROBA -multiswitch Type 019._00.2

08/07/2015

Moeller Electric Corporation

V2IM10AL10 Art.Nr.: V2IM10AL10P Art.Nr.: Control element. Tripping delay. Function selector. Status indication 24...

Power supply CP-D 24/4.2 Primary switch mode power supply

Type CP-S, CP-C & CP-A Switch mode

NSD Safety Mat Controller Modules Both Modules are compliant to OSHA & ANSI Standards - EN ISO EN EN 81-1 EN NSD VDC

27/04/2015

Thermistor motor protection relays

05/09/2012

Specifications Approval Type M12 A-coded HARAX M12-L HARAX M12 L 5 poles shielded M12 Crimp General data Electrical characteristics Materials 03 21

CIRUS UPT Operating instructions

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC

Theta 20A / 20V. Technical Data Sheet. Special Features

Theta 60R. Technical Data Sheet. Special Features. Fig. 2 Theta R, 2 channel version, in housing S17 hole mounting brackets pulled out.


Technical Information Barrier RB223

Monitoring Relays 3-Phase Active power direction Types DWB03, PWB03

Power supply CP-T 48/5.0 Primary switch mode power supply

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet

Power supply CP-T 24/10.0 Primary switch mode power supply

Power supply CP-T 24/40.0 Primary switch mode power supply

Power supply CP-E 24/2.5

Power supply CP-D 12/2.1

DIN 22.5/17.5 Size Lineup of A Wide Range of Measuring and Monitoring Relays. Model Number Structure

Installation and Operating Instructions for Phase Demodulator Type _.2

Power supply CP-D 24/1.3

Switching power supplies CP range, Linear power supplies CP-L range. Content

120/240 Watt AC-DC Front End with PFC W Series Convert Select 120 Convert Select 240

1-Phase True RMS AC/DC Over and Under Current Types DIC01, PIC01

Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact

Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC01, PPC01

NS..S contactor relays - with spring terminals AC operated

XR1 Rotor Earth Fault Relay. (May 2007) Manual XR1 (Revision New)

Electronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts

Protection relays and transformers

ABB NEW. Multifunctional three-phase monitoring relays. CM-MPS.23 and CM-MPS.43 Data sheet. Features J. Approvals. Marks.

RISH Ducer TV 808, 2 channels Isolating amplifier unipolar / bipolar

Energy Meters for DIN Rail Mounting Electric energy meter WS0101, WS0102,WS1102 WS0301, WS0302,WS1302

Three-phase monitoring relay CM-PFS

Power supply CP-T 48/20.0 Primary switch mode power supply

ABB 1. Multifunctional three-phase monitoring relays. CM-MPN.52, CM-MPN.62 and CM-MPN.72 Data sheet. Features. Approvals. Marks.

Electronic timer CT-SDE Star-delta change-over with 1 n/c + 1 n/o contact

Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multi-function Types DPB01, PPB01

Electronic timer CT-AWS Impulse-OFF with 1 c/o contact Data sheet

Power supply CP-E 24/20.0

Power supply CP-T 24/20.0 Primary switch mode power supply

CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. UL 508, CAN/CSA C22.2 No.14 GL GOST CB scheme CCC

Electronic timer CT-SDE

Electronic timer CT-YDE Star-delta change-over with 1 c/o (SPDT) contact

SIMEAS-T. Operating Instructions Transducer without auxiliary power. 7KG6111 and 7KG6101. Operating Instructions

Through and Ground Conductor Terminal Blocks 290 Series

02/11/2015

Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC71, PPC71

Safety switches with slotted hole lever

DATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection

Liquid level monitoring relay CM-ENS.2x

Multifunctional three-phase monitoring relays CM-MPS CM-MPS.23

W DATA SHEET Current Transformer 40 x 10, A

DATASHEET - ETR4-51-A. Delivery program. Technical data General. Timing relay, star-delta, 50 ms, 1W, 3-60s, VAC/DC

Incandescent Lampholders: Edison Screw and Bayonet Cap

Assembly. Front view. DIP switch. LED yellow: Relay output I. LED yellow: Relay output II. Potentiometer Hysteresis relay I Power Rail

isolr275 / AGH-LR Digital Ground Fault Monitor / Ground Detector For Low-Resistance Ungrounded (Floating) AC/DC Systems

ABB 1. Multifunctional three-phase monitoring relays. CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. Features. Approvals. Marks.

Electronic timer CT-ERS ON-delayed with 2 c/o contacts Data sheet

Type: EASY719 AC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 115/230 V AC. Description

Three-phase monitoring relays

Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC01, PPC01

Output of three-phase motors at 50 Hz and 400 V

Power supply CP-E 24/0.75

ABB NEW. Three-phase monitoring relays. CM-PVS.31 and CM-PVS.41 Data sheet. Features J. Approvals. Marks. Order data. Order data - Accessories

XR1 Rotor Earth Fault Relay. Manual XR1 (Revision C)

TRANSDUCER of TEMPERATURE and STANDARD SIGNALS P20 type

PRELIMINARY DATA SHEET RI-D140. Three Phase Multifunction DIN Rail Energy Meter (MID Certified) MID

Switched mode power supply for DIN rail mounting type SMP21 DC24V/10A

Transcription:

RESISTRON Operating Instructions GB RESISTRON/CIRUS temperature controllers are designed to implement a large number of standard applications. The required secondary voltages and currents can be set within a wide range. If - owing to the length of the heatsealing band - the required secondary voltage (U 2 or U R ) is higher than the maximum permissible voltage of the controller, an series resistor must be used. This series resistor is inserted into the supply lead of the U R measurement input. The enclosure of the series resistor can be snapped onto a top hat rail (DIN TS35). The resistor must be installed directly adjacent to the RESISTRON/CIRUS temperature controller. Continuous twisting of the U R measuring wire is essential - including between the series resistor and the controller.! The information provided in the ROPEX Application Report should be heeded when using the in order to avoid malfunctions. 1 Technical data Type of construction Housing for installation in the electrical cabinet Snaps onto a standard top hat rail (DIN TS35 rail, 35mm) acc. to DIN EN 50022 RV-300V-1: Dimensions: 79 x 45mm; height: 53mm RV-..K.-1: Dimensions: 79 x 13mm; height: 53mm Maximum permissible secondary voltage of the transformer Standards RV-300V-1: U 2max = 300VAC RV-03K3-1: U 2max = 40VAC RV-33K2-1: U 2max = 240VAC RV-100K-1: U 2max = 300VAC DINEN61010-1 (low voltage directive): Overvoltage category III, pollution severity 2, safety class II Resistance RV-300V-1: ---; electrical circuit RV-03K3-1: 3.3kohms; 0.6W RV-33K2-1: 33.2kohms; 0.6W RV-100K-1: 100kohms; 0.6W Power loss: RV-300V-1: max. 3.0W RV-03K3-1: max. 0.6W RV-33K2-1: max. 0.6W RV-100K-1: max. 0.6W Ambient temperature Degree of protection +5 +45 C IP20 4.7.06

/controller compatibility Weight RV-300V-1: approx. 150g RV-..K.-1: approx. 50g Housing material Connecting cables Type / cross-sections Plastic, UL-94-V0, self-extinguishing Rigid or flexible; 0.2 2.5mm² (AWG 24 12) Connection by means of screw terminals If ferrules are used, they must be crimped in accordance! with DIN 46228 and IEC/EN 60947-1. This is essential for proper electrical contact in the terminals. 2 /controller compatibility In the course of various RESISTRON and CIRUS temperature controller upgrades, it has become necessary to make changes to the internal electronics to bring them into line with the currently available electronic components (the use of components containing lead is meanwhile banned by the European RoHS/WEEE Directives, for instance). As a result, temperature controllers with DIP! switches can only be operated with an RV- 03K3-1, RV-33K2-1, or RV-100K-1 series resistor. Controllers without DIP switches (with a DIAG interface) are only allowed to be operated with a RV-300V-1 series resistor. Malfunctions or damage may otherwise occur. Please pay attention to the controller version when ordering spare parts. The controller may have to be exchanged together with the series resistor. Refer to the compatibility tables below: RV-300V-1 (controllers without DIP switches) Controller type RES-401/...VAC as of October 2005 7401.. RES-402/...VAC as of January 2006 7402.. RES-403/...VAC as of October 2005 7403.. RES-406/...VAC as of February 2006 7406.. RES-407/...VAC as of April 2005 7407.. RES-408/...VAC as of June 2006 74084. RES-415/...VAC as of February 2006 7415.. RES-420/...VAC as of December 2005 7420.. RES-440/...VAC as of March 2006 7440.. RES-445/...VAC as of January 2006 7445.. Art. No. Required series resistor RV-300V-1 Art. No. 886200 (Refer to ROPEX Application Report) Page 2

Installation procedure RV-03K3-1, RV-33K2-1, RV-100K-1 (controllers with DIP switches) Controller type RES-401/...VAC up to September 2005 7401.. RES-402/...VAC up to December 2005 7402.. Art. No. Required series resistor RES-403/...VAC up to September 2005 7403.. RES-406/...VAC up to January 2006 7406.. RES-407/...VAC up to March 2005 7407.. RES-408/...VAC up to May 2006 74080.; 74081. and 74083. RES-409/...VAC 7409.. RES-415/...VAC up to January 2006 7415.. RES-420/...VAC up to November 2005 7420.. RES-440/...VAC up to February 2006 7440.. RES-445/...VAC up to December 2005 7445.. RV-03K3-1 Art. No. 886203 RV-33K2-1 Art. No. 886202 RV-100K-1 Art. No. 886201 (Refer to ROPEX Application Report) UPT-640/...VAC 66401. and 66402. LPT-640/...VAC 66405. and 66406. 3 Installation procedure 3.1 Secondary circuit grounding If an is used, the secondary circuit! must always be grounded for safety reasons. If not, a short-circuit to frame on the heatsealing band could result in damage to the controller or injury to persons. If the secondary circuit is grounded at one! end, terminal 1 on the must be connected to the grounded end of the heatsealing band in order to avoid malfunctions and damage. Up to a secondary voltage of 240VAC, the! circuit can also be grounded by tapping the neutral point of the transformer secondary winding (terminals 1 and 2 of the can have any polarity). 3.2 Monitoring current transformer MSW-1 If the secondary circuit is grounded, the use! of an MSW-1 monitoring current transformer is recommended. This prevents overheating in case of a short-circuit to frame on the heatsealing band. 3.3 Controller alarm output/ contactor Kb If an is used, a contactor for all-pole! disconnection must be inserted between the controller and the impulse transformer (refer to the controller documentation, "Power supply", contactor Kb). This contactor must be energized directly via the controller alarm output to ensure that the heatsealing application is immediately disconnected in the event of an alarm. Page 3

Wiring diagram 4 Wiring diagram 4.1 RV-300V-1 (controllers without DIP switches) The secondary circuit must be grounded and contactor Kb inserted! Strict compliance with the installation procedure is essential. U R HEATSEALING BAND 1 3 5 RES-4xx UPT-6xx LPT-6xx NO DIP switches 2 60-180V 100-300V 4 RV-300V-1 Y X Green LED, indicates pulses in measurement mode. In control mode, luminous intensity is proportional to heating current. 4.2 RV-03K3-1, RV-33K2-1, RV-100K-1 (controllers with DIP switches) The secondary circuit must be grounded and contactor Kb inserted! Strict compliance with the installation procedure is essential. U R HEATSEALING BAND 1 3 RES-4xx UPT-6xx LPT-6xx WITH DIP switches 2 4 RV-03K3-1 RV-33K2-1 or RV100K-1 0V (Internal ground) No external grounding allowed! Y X Page 4

Wiring diagram 4.3 Connection between and RESISTRON/CIRUS controller Controller Terminal 2 connected to (X) Terminal 4 connected to (Y) RES-401 RES-403 Terminal 7 Terminal 9 RES-402 Terminal 8 Terminal 7 RES-406 RES-407 RES-408 RES-409 RES-415 RES-420 RES-440 RES-445 UPT-640 (CIRUS) LPT-640 (CIRUS) RESCON-470 (as of 10/2000) Terminal 9 Terminal 8 Terminal 11 Terminal 10 Terminal 20 Terminal 19 Page 5

Dimensions 5 Dimensions 5.1 RV-300V-1 79 mm 53 mm 45 mm 5.2 RV-03K3-1, RV-33K2-1, RV-100K-1 79 mm 53 mm 13 mm 6 How to order series resistor RV-300V-1 (electrical circuit): Art. No. 886200 RV-03K3-1 (resistance 3.3kohms): Art. No. 886203 RV-33K2-1 (resistance 33.2kohms): Art. No. 886202 RV-100K-1 (resistance 100kohms): Art. No. 886201 Page 6