ECG versions Order no. Output currents Output power LCS135-70FX-01/220-240 10116496 350 ma max. 70 W LCS150-70FX-01/220-240 10116500 500 ma max. 70 W LCS170-70FX-01/220-240 10116504 700 ma max. 70 W Performance characteristics Non-dimmable 1-channel ECG for constant current operation of LED modules Non-SELV output voltage Very high efficiency of up to 93 % (100 % load) For use in luminaires of protection class I ECG extensively protected against abnormal operating conditions at the output e.g. short-circuit, open circuit or overload Suitable for direct current operation and application in combination with central battery installations Certified as thermally protected device Conformance with international regulations, regarding safety and operation, electromagnetic compatibility and immunity to interference Nominal service lifetime with a failure rate 10 %: 30,000 h at t c = t c,max 50,000 h at t c = t c,max - 10K Applications Office Industrial Shop Markings 7 110 alternations in the interest of improving our products. 02/2016 1/5
General technical data Mains voltage supply Rated voltage range 220... 240 V Max. permanent voltage range (continuous) 198... 264 V Rated frequency 0 / 50... 60 Hz Battery operation Voltage range for continuous operation 198... 278 VDC Lowest limiting value for temporary operation 176 VDC / 0.5 h Mains overvoltage Overvoltage protection 350 VAC / 2 h Automatic switch-off of the LEDs at appr. 320 VAC Protection against voltage peaks Voltage peaks L - N 1 kv Voltage peaks L/N -PE 2 kv Starting time Time to 100% luminous fl ux < 0.5 s Total harmonic distortion (THD) At 100% load to ECG-output < 10 % Output data Tolerance of output current +/- 10 % Max. ripple of output current +/- 20 % Max. wire length to LED module 2 m Galvanic separation to mains input no Protection functions output side Overload operation yes; ECG switch-off, restart after mains interruption Short-circuit operation yes; limitation of the output current Open-circuit operation yes; ECG switch-off, restart after mains interruption Lifetime Operation at t c = t c,max 30,000 h; failure rate 10 % Operation at t c = t c,max - 10 K 50,000 h; failure rate 10 % Connection terminals Type Terminal with release hole Wire cross section 0.5 mm² - 1.5 mm² Wire stripping length 8 mm - 9 mm Thermal protected device Max. sureface temperature acc. to EN 61347-1/C5e + 110 C Degree of protection Degree of protection of ECG housing IP 20 Terminals and ECG construction are designed for an automatic wiring with robots Order no. for release spike: 10075741 2/5 2/6 alternations in the interest of improving our products 02/2016
Temperatures (operation) Ambient (t a ) Case (t c ) LCS135-70FX-01... 25 C... +50 C max. + 75 C LCS150-70FX-01... 25 C... +50 C max. + 75 C LCS170-70FX-01... 25 C... +50 C max. + 75 C Lifetime LCS135-70FX-01... LCS150-70FX-01... LCS170-70FX-01... typ. I peak /Δt 30 A / 115 μs 30 A / 116 μs 37 A / 151 μs Number of ECG at one singlepole circuit breaker (CB) CB-Typ 10 A 16 A 20 A 25 A B 24 39 49 61 C 25 41 51 64 B 24 38 48 60 C 25 41 51 64 B 15 24 30 37 C 25 40 50 62 Typical current - time profile when switching on I[A] Ipeak ½ x Ipeak - Data for U supply = 230 VAC, mains impedance = 1 Ω - In case of multi-polar CB the maximum number is reduced by 20 % - The max. number may differ depending on CB manufacturer. Please consider the specifications of the manufacturer. - Basically, CB with C-characteristics are recommended to be used in lighting groups. t t Operating data Input current Input power W Power factor LCS135-70FX-01.. 0,32 72 0,99 93 350 60... 190 21... 66,5 LCS150-70FX-01.. 0,33 76 0,99 92 500 60... 140 30... 70,0 LCS170-70FX-01.. 0,34 77 0,99 91 700 60... 100 42... 70,0 All specifications with 230 VAC nominal operation and 100 % ECG Output currents 4) Output voltage / efficiency channel A % ma V W Total output 2), 3) power alternations in the interest of improving our products. 02/2016 3/5
Operating data 200 180 160 LCS135-70FX LCS150-70FX LCS170-70FX 140 Output voltage per channel [V] 120 100 80 60 40 20 0 0 100 200 300 400 500 600 700 800 900 1000 Output current per channel [ma] Efficiency and power factor Efficiency vs. output load 100 Power factor vs. output load 1 90 0,95 Efficiency [%] 80 70 Power factor 0,9 0,85 0,8 LCS 60 20 40 60 80 100 LCS 0,75 20 40 60 80 100 Total load on ECG output [%] Total load on ECG output [%] 4/5 4/6 alternations in the interest of improving our products. 02/2016
Wiring diagrams ECG 1 Connection of ECG output side A Connection of ECG input side L N PE + CH1 LED - more ECG ECG dimensions X X M Y Z Z M mm mm mm mm mm LCS135-70FX... 280 270 30 21 9 LCS150-70FX... 280 270 30 21 9 LCS170-70FX... 280 270 30 21 9 Xm X Zm Z Y Logistic data Order no. EAN Weight ECG LCS135-70FX-01/220-240 10116496 4046189032896 0,197 66 345 x 285 x 182 14 LCS150-70FX-01/220-240 10116500 4046189032902 0,197 66 345 x 285 x 182 14 LCS170-70FX-01/220-240 10116504 4046189032919 0,221 66 345 x 285 x 182 15 Packaging unit ECG PU Dimensions PU kg pcs. mm kg Weight PU Conformance with regulations EN 61347-1 EN 61347-2-13 EN 62384 EN 61547 EN 55 015 IEC 60 068-2-6 IEC 60 068-2-27 General and safety requirements Particular requirements for d.c. or a.c. supplied electronic control gear for LED modules D.C. or A.C. supplied electronic control gear for LED modules - Performance requirements Equipment for general lighting purposes - EMC immunity requirements Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment Environmental testing: Tests Test Fc: Vibration (sinusoidal) Environmental testing: Tests Test Ea and guidance: Shock 02/2016 160215 alternations in the interest of improving our products. 02/2016 5/5