SPECIFICATION ESD FSP500-60GHC. Released Date:2012/12/26-15:25:33

Similar documents
SPECIFICATION ESD FSP460-60HCN. Released Date:2011/04/01-15:26:46

SPECIFICATION ESD FSP250-60HNC. Released Date:2012/08/15-21:58:49

SPECIFICATION ESD FSP300-60GHT,(85)F. Released Date:2016/05/18-15:38:12

SPECIFICATION ESD Released Date:2012/12/20-10:56:04

SPECIFICATION. SilverStone. 300W SFX Switching Power Supply FSP300-60GHS Meet 80 Plus Active PFC Circuit Full Range Input Small Size

SPECIFICATION ESD Released Date:2012/09/28-18:39:41

SPECIFICATION ESD Released Date:2013/12/23-18:11:46

TC-2U70PD8. Switching Power Supply ( 2U 700W 80PLUS) SPECIFICATION. Revision: 2.0

SPECIFICATION ESD FSP600-80PSA(SK) Released Date:2017/02/08-10:47:01

ST-250MAK-05E. Switching Power Supply SPECIFICATION

TC-600PD2. Switching Power Supply ( 600W PS2 ATX12V ) SPECIFICATION. Revision: 1.0

SPECIFICATION. SilverStone OLYMPIA OP1000 Switching Power Supply Active PFC

TC-750PD8. Switching Power Supply ( PS2 ATX750W 8 0 PLU S ) SPECIFICATION. Revision: 1.0

Product Specification

SPECIFICATION SWITCHING POWER SUPPLY BPS-300SP/2U 6-OUTPUT WITH ACTIVE PFC FUNCTION SINGLE POWER 300W BEST POWER SOLUTIONS, INC.

SPECIFICATION SWITCHING POWER SUPPLY SINGLE POWER 250W BEST POWER SOLUTIONS, INC. 9F, NO.196-7, SEC.3, TA-TUNG RD SHI CHIH, TAIPEI, TAIWAN, R.O.C.

SPECIFICATION REDUNDANT POWER SUPPLY HOT-SWAPPABLE 370W+370W

SPECIFICATION SilverStone ST30NF for Standard Switching Power Supply With Active PFC PS/2 Fanless 300W

SPECIFICATION REDUNDANT POWER SUPPLY HOT-SWAPPABLE BPS-460RDX 6-OUTPUT 460W+460W BEST POWER SOLUTIONS, INC.

SPECIFICATION ARP

Matrix Power Company MH xxx-va series Specification Document

Switching Power Supply SPECIFICATION

SFX Form Factor SST-SX650-G SST-SX500-G. The standard SFX power supply benchmark

OP650 -P. Single rail stepping up to a higher gear OP SERIES

APPROVAL SHEET 12V/2A EA1019HHUS(03) EA1019HHUS-120 APP D EDAC POWER ELECTRONICS CO., LTD. TEL: FAX:

VISION HISTORY Rev Level Rev Date Change Made Reason for Change Effective Approved By A 11/11/13 Specification Release S. Sadot A1 14/01/14 Update ope

All specifications valid at normal input voltage, full load and +25 C after warm-up time unless otherwise stated.

SPECIFICATION. SilverStone Zeus ST75ZF. Switching Power Supply. With Active PFC PS/2 750W

DA850. The all around power DECATHLON

All specifications valid at normal input voltage, full load and +25 C after warm-up time unless otherwise stated.

PEAK OUTPUT CURRENT 1. MAP V 4.7V to 5.8V 8A 11A 0.2% ±1% 1% 4.9V to 5.1V PEAK OUTPUT CURRENT 4 LINE REGULATION

Single-output models feature wide-range output adjustability to meet a wide variety of standard and user-specific output voltage requirements.

規格書. Electrical Specification. 桃園縣大園鄉三石村三和路 3 巷 7 號 ( 力信工業大樓 ) 7,Lane 3,San Ho Rd,San-Shin Village,Da-Yuan Hsiang,Taoyuan Hsien 337,Taiwan, R.O.C.

PDAM500 Series 500W Power Supply

INPUT VOLTAGE STARTING MINIMUM NORMAL MAXIMUM MAXIMUM INPUT RANGE VOLTAFE VOLTAGE VOLTAGE VOLTAGE CURRENT

This convection-cooled series is designed for use in commercial and industrial environments in temperatures up to 50 C.

規格書. Electrical Specification. 桃園縣大園鄉三石村三和路 3 巷 7 號 ( 力信工業大樓 ) 7,Lane 3,San Ho Rd,San-Shin Village,Da-Yuan Hsiang,Taoyuan Hsien 337,Taiwan, R.O.C.

ENHANCE SWITCHING POWER SUPPLY SPECIFICATION 250 WATT MODEL NO:V525

These medical power supplies are ideal for monitoring, home health equipment as well as surgical devices.

Line Reg Load Reg Ripple Efficiency *Model Number Output V Output I (nom/max) (nom/max) & Noise (min/nom)

SSD3000 MODULE 280 WATT 12V FRONT END 8.66 x 1.99 x x 50.5 x 40mm

APPROVAL SHEET I TUNER 12V/10.83A EA11703A(01) EA11703A-120 APP D EDAC POWER ELECTRONICS CO., LTD. TEL: FAX:

LCL Series. SIngle Output Industrial Supplies. High Efficiency. Low Cost. 150 W Convection Cooled. 300 W & 500 W with Internal Fans

Electrical Specifications

18093-PS PHIHONG TECHNOLOGY CO., LTD. General Specification PSM (DC)

These power supplies are ideal for telecom, datacom, industrial equipment and other applications.

5 x 3 x 0.75 Inches form factor. 275 Watts with Forced Air Cooling. Efficiencies up to 92% Standby Power < 0.5 W

SPECIFICATION FOR APPROVAL

Electrical Specifications

70 Watt Switching Medical Grade Switching Power Supply with Active PFC CONTENTS 1. GENERAL CIRCUIT TOPOLOGY...2

DSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.

RoHS APPROVAL SHEET. ituner 12V/5A SERIES NO. (05) EA10523C-120 CUSTOMER CUSTOMER P/N DESCRIPTION EDAC MODEL DATE REVISION 0

ECP225-A Series. 225 Watts. AC-DC Power Supplies. Models & Ratings

These power supplies are ideal for medical, telecom, datacom, industrial equipment and other applications.

LB115S 115W Single Output

The MPB150 product line is approved to the latest international regulatory standards, and displays the CE Mark.

Compliance. Safety Approvals USA Canada Europe. Isolation: General. Dimensions. AC Input CN1 Output CN2 Optional CN3. Weight

DSR120 Series. xxx Series. 120 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details

VOF XX - XXX - X

All specifications valid at normal input voltage, full load and +25 C after warm-up time unless otherwise stated.

UP1301A-( )( ) SERIES

420 W High Line Output Power. Rugged Industrial Construction. -40 C to +70 C Operation. 5 V Standby. Screw Terminals. SEMI F47 Compliant

CLP0205 Open Frame Power Supply Vac input; 5Vdc output; 200W Output Power; 0.25A stdby

IS -500RSH1UP. Redundant Power Supply ( 1U- 500W ) SPECIFICATION. Revision: 1.0

The MBC550 range is ideally suited to a wide variety of medical applications, and also where airflow is limited or not available.

NLP65 SERIES 75 Watt Open Frame Power Supply Measures: 5.00 x 3.00 x 1.26

REDUNDANT AC 300W POWER SUPPLY. Technical Specifications TD-AC-300W-MAX

TB65 65W Single Output Test and Measurement/Industrial Series

SFD550-12BG Front-End Preliminary Data Sheet DC Input, 12V Output, 550 Watts

The MDU150 Series provides the same benefits as the MPU150 Series, with nominal 48 volt DC input.

REDUNDANT DC 200W POWER SUPPLY. Technical Specifications TD-DC-200W-12V

11SP 4247 LCD TV Power specification Rev 1.3 Specification

Product Specification sheet

NLP40 SERIES 50 Watt Open Frame Power Supply Measures: 4.25 x 2.50 x 1.15

Asia-Pacific North America Europe, Middle East Bel Power Solutions, Inc. BCD.

AEA300R22S / AEA400R22S-1 Power Supply Product Specification

1.6W Gate Drive DC-DC Converter P2AGDC-Series

HRPG-1000 series. 1000W Single Output with PFC Function. File Name:HRPG-1000-SPEC Sicherheit ID

300W Industrial 1U ATX 12V/P4 PC Power Supply CH3 12V STANDBY 5VSB RATED CURRENT CURRENT RANGE 30A 1 ~ 30A 18A 1 ~ 18A

CLP0224 Open Frame Power Supply Vac input; 24Vdc output; 200W Output Power

IEC/EN/UL60950 & CE certified, EN55032 Class B

Parameter Condition Min. Typ. Max. Internal Input Filter 115VAC 230VAC 115VAC 230VAC. No load Power Consumption

REVISIONS 06/26/06 YS TEMPS FILE NAME: CAD1:MSWORD:PA DOC SCALE: NONE REV: D SH 1 OF 7 TITLE: OVS-U (UNIVERSAL INPUT) SERIES SPECIFICATION

Parameter Condition Min. Typ. Max. Internal Input Filter. refer to line derating graph on PA-4 115VAC 230VAC 115VAC 230VAC. No load Power Consumption

HEC-45LTN-45PFAS Rev A

Medical Safety Approvals (-M versions) Industrial Heavy Duty Terminals. Output Power up to 1500 W. High Power Density - 18W/in 3

NIGHTJAR SERIES SST-ST45NF. Optimum fan-less power supply with stability and silence

AED500H22S Power Supply Product Specification. An APM Electronics USA, Inc. Power Supply Specification For ERP1U Power Supply

1000W Single Output Medical Type. MSP-1000 series. File Name:MSP-1000-SPEC

General. Environmental. EMC & Safety

POWER DS Watts Distributed Power System. Data Sheet

Data Sheet GTD21148L SERIES 40W. (201) Switching Power Supplies

All specifications valid at normal input voltage, full load and +25 C after warm-up time unless otherwise stated.

These medical power supplies are ideal for, monitoring, home health equipment as well as surgical devices.

PSU s e r i es

Electrical Specifications. Adjustment range Main output ± 5% Total regulation (line and load) ± 2.0% ± 5.0% Turn-on 120 Vac Input 2.0 s max.

AC/DC Power Supply Single-Output

Customer s Approval Signature

LFWLP W 12V 15.00A 25.00A 92%

ECC100 Series. -40 ºC to +75 ºC Operation. 100 W - Baseplate Cooled. High Efficiency Resonant Topology. Screw Terminals Available.

Transcription:

SPECIFICATION ESD08032632 FSP500-60GHC Released Date:2012/12/26-15:25:33

1/10 禁止翻印外洩 ESD08032632-R10.pdf 發行時間 :2012/12/26 全漢企業股份有限公司 FSP TECHNOLOGY INC. 台灣桃園市建國東路 22 號 NO.22,Jianguo E, Rd.,Taoyuan City,Taiwan,R.O.C. TEL:+886-3-375-9888 FAX:+886-3-375-6966 SPECIFICATION FSP500-60GHC 9PA5002100 Main Feature: Low Noise Meet 80plus Meet 2013 ErP Active PFC Circuit Full Range Input ATX2.3 Version Dec. 13, 2012 REV : 1.06

2/10 禁止翻印外洩 ESD08032632-R10.pdf 發行時間 :2012/12/26 全漢企業股份有限公司 FSP TECHNOLOGY INC. MODEL: FSP500-60GHC Revision History Rev Description Date Author 1.00 2008/06/18 1.01 Revise Table 1. Loading Table for Efficiency Measurements & Table 2. Minimum Efficiency Vs Load 2008/09/19 1.02 Revise 4.2. LOAD CAPACITY SPECIFICATIONS 2009/09/21 1.03 Revise 3.4. EFFICIENCY Add 3.4.2 Standby Power Consumption (5Vsb) 2009/10/22 1.04 Revise 6.1. TEMPERATURE RANGE 2010/12/09 1.05 Revise 4.1. OUTPUT VOLTAGE AND CURRENT RATING 2011/07/18 1.06 Revise 2010 ErP 2013 ErP & OUTPUT RISE TIME 2012/12/13 2

1. GENERAL DESCRIPTION AND SCOPE This is the specification of Model FSP500-60GHC; AC-line powered switching power supply with active PFC (Power Factor Correction) circuit, meet EN61000-3-2 and with Full Range Input features. Also, +5Vsb power is less than 0.5W input at power off mode (PS_ON input at high state) which is comply with ErP Lot 6 year 2013 requirement. The specification below is intended to describe as detailedly as possible the functions and performance of the subject power supply. Any comment or additional requirements to this specification from our customers will be highly appreciated and treated as a new target for us to approach. 2. REFERENCE DOCUMENTS The subject power supply will meet the EMI requirements and obtain main safety approvals as following: 2.1. EMI REGULATORY - FCC Part 15 Subpart J, Class B 115 Vac operation. - CISPR 22 Class B 230 Vac operation. 2.2. SAFETY - NEMKO EN 60950-1: 2001; A11 - TUV EN 60950-1 - CSA 60950-1 - IEC 60950-1 : 2001 - UL 60950-1, First Edition - FCC CISPR22/1997(Class B Limit) - CE : EN 55022/2006(CISPR 22/2005) EN 55024/1998+A1/2001+A2/2003 EN 61000-3-2/2006 EN 61000-3-3/1995+A1/2001+A2/2005 EN 61204-3/2000 3 3/10 禁止翻印外洩 ESD08032632-R10.pdf 發行時間 :2012/12/26

3. INPUT ELECTRICAL SPECIFICATIONS 3.1. AC INPUT Parameter Min. Nom. (1) Max. Unit V in (115VAC) 90 115 135 VAC rms V in (230VAC) 180 230 265 VAC rms V in Frequency 47 -- 63 HZ Nominal voltages for test purposes are considered to be within ±1.0V of nominal. 3.2. INRUSH CURRENT Maximum inrush current from power-on (with power on at any point on the AC sine) and including, but not limited to, three line cycles, shall be limited to a level below the surge rating of the input line cord, AC switch if present, bridge rectifier, fuse, and EMI filter components. Repetitive ON/OFF cycling of the AC input voltage should not damage the power supply or cause the input fuse to blow. 3.3. INPUT LINE CURRENT & POWER FACTOR (P.F.) (At Full load) AC input Input line current P.F.@ Full Load P.F.@ Pin=75W 115V < 6.0Amps rms > 0.95 > 0.8 230V < 3.0Amps rms > 0.9 > 0.65 3.4. EFFICIENCY 3.4.1 General Under the load conditions defined in Table 1 and Table 2. The loading condition for testing efficiency shown in Table 1 represents a fully loaded system. a ~ 50% (typical) loaded system. and a ~ 20% (light) loaded system. 4 4/10 禁止翻印外洩 ESD08032632-R10.pdf 發行時間 :2012/12/26

Table 1. Loading Table for Efficiency Measurements 500W(loading shown in Amps) Loading +12V1 +12V2 +5V +3.3V -12V +5Vsb FULL 15.69 15.69 12.92 12.92 0.44 2.18 TYPICAL 7.85 7.85 6.46 6.46 0.22 1.09 LIGHT 3.14 3.14 2.58 2.58 0.09 0.44 Table 2. Minimum Efficiency Vs Load Loading Voltage FULL TYPICAL LIGHT Required Minimum Efficiency 115V 80% 81% 80% Required Minimum Efficiency 230V 81% 82% 80% 3.4.2 Standby Power Consumption (+5Vsb): Input Power < 0.5W @ 5Vsb/45mA & 230Vac input PS_ON input signal @ High State 4. OUTPUT ELECTRICAL REQUIREMENTS 4.1. OUTPUT VOLTAGE AND CURRENT RATING Output MINIMUM LOAD NORMAL LOAD MAXIMUM LOAD PEAK LOAD LOAD REG. LINE REG. Ripple & Noise +3.3V 0.1A 12A 24A ±5% ±1% 50mV P-P +5V 0.2A 12A 24A ±5% ±1% 50mV P-P +12V1 0.1A 9A 18A ±5% ±1% 120mV P-P +12V2 0.5A 9A 18A 19A ±5% ±1% 120mV P-P -12V 0A 0.25A 0.5A ±10% ±1% 120mV P-P +5VSB 0A 1.25A 2.5A 3.5A ±5% ±1% 50mV P-P ( 1 ) +3.3V & +5V total output not exceed 120W. ( 2 ) Maximum combined current for the +12V outputs shall be 36A. ( 3 ) +12V2 peak current is 18A (less then 10m Sec.), minimum voltage during peak is >11.0Vdc. ( 4 ) +5Vsb peak current is 3.5A(less then 500m Sec.), minimum voltage during peak is > 4.5Vdc. ( 5 )Voltages and ripple are measured at the load side of mating connectors with a 0.1 uf monolithic ceramic capacitor paralleled by a 10 uf electrolytic capacitor across the measuring terminals. 5 5/10 禁止翻印外洩 ESD08032632-R10.pdf 發行時間 :2012/12/26

4.2. LOAD CAPACITY SPECIFICATIONS The cross regulation defined as follows, the voltage regulation limits DC include DC Output ripple & noise. LOAD +3.3V +5V +12V1 +12V2-12V +5VSB Condition_1 X X X X X 2.5A Condition_2 0.2A 0.2A 0.1A 0.5A 0A 0A Condition_3 0.3A 0.2A 0.1A 0.5A 0.5A 0.05A Condition_4 0.5A 5A 18A 18A 0A 0.5A Condition_5 0.1A 15A 2A 2A 0A 0.5A Condition_6 0.9A 24A 15A 15A 0.3A 2.5A Condition_7 12A 12A 10A 10A 0.25A 2.5A Condition_8 20A 2A 2A 2A 0A 1A Condition_9 24A 8.5A 15A 15A 0.5A 2.5A 4.3. OVER VOLTAGE PROTECTION Voltage Source Protection Point +3.3V 3.76V-4.8V +5V 5.6V-7.0V +12V 13.0V-16.5V 4.4. OVER CURRENT PROTECTION OUTPUT VOLTAGE Max. over current limit +3.3V 60A +5V 48A +12V1 30A +12V2 30A 6 6/10 禁止翻印外洩 ESD08032632-R10.pdf 發行時間 :2012/12/26

7/10 禁止翻印外洩 ESD08032632-R10.pdf 發行時間 :2012/12/26 4.5. SHORT CIRCUIT PROTECTION Output short circuit is defined to be a short circuit load of less than 0.1 ohm. In the event of an output short circuit condition on +3.3V, +5V, +12V or 12V output, the power supply will shutdown and latch off without damage to the power supply. The power supply shall return to normal operation after the short circuit has been removed and the power switch has been turned off for no more than 2 seconds. 4.6. POWER SIGNAL POWER GOOD @115/230V, FULL LOAD POWER FAIL @115/230V, FULL LOAD 100 500mSec. 1 msec. minimum Figure: T1: Power-on time shall be less than 500 ms (T1 < 500 ms). T2: Rise time : 0.1 ms to 20 ms (0.1 ms T2 20 ms). T3: Power-ok delay time: 100 ms < T3 < 500 ms T4: Power-ok rise time: T4 1 ms T5 + T6: AC loss to PWR_OK hold-up time 7

OUTPUT RISE TIME (10% TO 90% OF FINAL OUTPUT VALUE, @ FULL LOAD) 115V-rms or 230V-rms + 3.3Vdc : 20ms Maximum + 5Vdc : 20ms Maximum + 12Vdc : 20ms Maximum + 5Vsb : 20ms Maximum - 12Vdc : 20ms Maximum 4.7. HOLD-UP TIME (@ FULL LOAD of Table 1.) 115V / 60Hz : 17 msec. Minimum. 230V / 50Hz : 17 msec. Minimum. The output voltage will remain within specification, in the event that the input power is removed or interrupted, for the duration of one cycle of the input frequency. The interruption may occur at any point in the AC voltage cycle. The power good signal shall remain high during this test. 4.8. The main power supply shall be off when the PS_ON pin is floating (open collector). The ON/STBY pin of P1 must remain off state for 5 Sec (maximum) prior to switching to the ON state. 5. FAN NOISE REQUIREMENTS 5.1. The subject power supply is cooled by a self-contained, 80mm, 12VDC fan. 6. ENVIRONMENTAL REQUIREMENTS The power supply will be compliant with each item in this specification for the following Environmental conditions. 6.1. TEMPERATURE RANGE Operating Storage +10 to +40 deg. C -20 to +80 deg. C 8 8/10 禁止翻印外洩 ESD08032632-R10.pdf 發行時間 :2012/12/26

6.2. HUMIDITY Operating Storage 5 95% RH, Non-condensing 5 95% RH, Non-condensing 6.3. VIBRATION The subject power supply will withstand the following imposed conditions without experiencing non-recoverable failure or deviation from specified output characteristics. Vibration Operating Sine wave excited, 0.25 G maximum acceleration, 10-250 Hz swept at one octave / min. Fifteen minute dwell at all resonant points, where resonance is defined as those exciting frequencies at which the device under test experiences excursions two times large than non-resonant excursions. Plane of vibration to be along three mutually perpendicular axes. 6.4. GROUND LEAKAGE CURRENT The power supply ground leakage current shall be less than 3.5 ma. 6.5. RELIABILITY The power supply reliability,when calculated by MIL-HDBK-217;latest revision, are exceed 100,000 hours with all output at maximum load and an ambient temperature of 25. 6.6. DIELECTRIC STRENGTH Primary to Frame Ground : 1800 Vac for 1 sec. Primary to Secondary : 1800Vac for 1 sec 6.7. INSULATION RESISTANCE Primary to Frame Ground : 20 Meg.ohms Minimum Primary to Secondary : 20 Meg.ohms Minimum 9 9/10 禁止翻印外洩 ESD08032632-R10.pdf 發行時間 :2012/12/26

7. LABELLING Label marking will be permanent, legible and complied with all agency requirements. 7.1. MODEL NUMBER LABEL Labels will be affixed to the sides of the power supply showing the following: - Manufacturer s name and logo. - Model no., serial no., revision level, location of manufacturer. - The total power output and the maximum load for each output. - AC input rating. 8. MECHANICAL SPECIFICATIONS The mechanical drawing of the subject power supply, which indicate the form factor, location of the mounting holes, location, the length of the connectors, and other physical specifications of the subject power supply. Please refer to the attachment drawing. 10 10/10 禁止翻印外洩 ESD08032632-R10.pdf 發行時間 :2012/12/26