Medical Division Precision in diagnosis and therapy. Guide wires

Similar documents
Jul Member of the KERN-LIEBERS Group 1

ERCP Papillotomes, balloons, guide wires and baskets.

Devices for Enteroscopes

Coatings. The Merit Hypotube. Coated Guide Wire Components. Coated Mandrels & Stylets. Coated Needles. Coating Services & Capabilities

CROSS YOUR WAY SUPPORT CATHETERS GUIDEWIRES CROSSING CATHETERS RE-ENTRY DEVICES

Wire Technology: How to Choose Based on Anatomy and Strategy

Anatomy of Contemporary CTO Guidewires and Selection Criteria

MADE IN GERMANY INDUSTRIAL ENAMELLING DIES

Coils, Wire Forms, PRECISION SPRINGS, COILS & WIRE FORMS

Leading the Way in Guide Wire Technology

Guidewires for the CTO Interventionalist. William L. Lombardi MD FACC FSCAI Peacehealth St. Joseph Medical Center Bellingham WA

(Biomedical Engineering Design) Spring 2009

Bomei Co., Ltd. 4F., No , Chunrih Road, Taoyuan City, Taoyuan County, Taiwan Tel: / Fax: / Web:

EP A1 (19) (11) EP A1 (12) EUROPEAN PATENT APPLICATION. (43) Date of publication: Bulletin 2010/51

Folding Center XL-Center

Medical Device Manufacturing: Designing for X-ray Inspection. Gil Zweig, President Glenbrook Technologies.

MIG/MAG Welding Torch MB 26 KD air-cooled

MIG/MAG Welding Torch ABIMIG 645 W liquid-cooled

(Biomedical Engineering Design) Spring 2009

Tool manufacturing BEIER

A case of tortuous calcified LAD CTO treated using a "GAIA" guidewire

MIG/MAG Fume Extraction Torch RAB Plus 240 D liquid-cooled. New, lighter, more flexible... BINZEL. The right welding torch for every job!

MIG/MAG Welding Torch ABIMIG 401 WT / ABIMIG 501 WT liquid-cooled, with divided liner

The Current CTO Toolbox

(12) Patent Application Publication (10) Pub. No.: US 2004/ A1

TruLaser Tube: Optimal tube. and. profile cutting. Machine Tools / Power Tools Laser Technology / Electronics Medical Technology

Punches. SYNEO, the leading edge in medical automation solutions, is. pleased to announce the ISO 9001:2008 certification of its Texas

Saitama COMPAMED 2017 MEDICA 2017 JAPAN EXHIBITORS EXHIBITORS

(8) ANGLE 90. (12) Patent Application Publication (10) Pub. No.: US 2006/ A1. (19) United States UTER SHAFT CURVATURE INNER SHAFT

Easy mounting and cleaning. Very modular with columns and shelving. Extremely strong

Unrivalled cutting performance

Hobart Stainless Steel Solid Wire Drums Setup Guide

Metal Drilling.

Strip straighteners. Strip spectrum The following coil strips can be processed using our straightening

DRAG FINISHING UNITS DF SERIES

STAHL ENDOSCOPY UROLOGY

Flexible Hypotubes: Lasers Enable Medical Device Delivery. Flexible Hypotubes

Tungsten Carbide Burs for Tough Applications

YOUr VITaL ParTNEr For life-changing solutions

SPIRAL PIPE PLANTS. Tailor-made solutions with measurable benefits

Just where it s needed

Pocket Reference Cards

WHERE WE LIVE, QUALITY HAS A LONG TRADITION DRAG FINISHING UNITS SF SERIES. Precision finish demands. Precision finish demands

Universal Screwdriver

MEASURING SYSTEMS FOR THE STEEL INDUSTRY

BE SURE WITH SUREPRINT

Wire Wire rod, single and multiple wires

INDUSTRY SOLUTIONS GEARS. Clamping solutions»gearing up for Precision«

WESTERN WIRE PRODUCTS

Die Schraube. corrosion protection. SPAX with optimised point and WIROX surface. SPAX The screw. Technology, features and expertise.

In-Line Resistance Thermometers Model TR25

3. ISO information on technical standardisation changeover to ISO

KEY SURGICAL WIRE AND PIN MANAGEMENT

Fax Japan São Paulo (SP) Tokyo Minato-ku , Minami-Aoyama. St. Jude Medical Brasil Ltda.

EACON. Field mountable microwave cable. INEXIM Sp. z o.o. Edition Bezpośredni importer i dystrybutor

Titanium. The most biocompatible metal. Dentaurum. shop.dentaurum.com

SKILLS AND EXPERTISE in sheet metal and wire. from Project Management through to Customer Service

Brazing Solutions for the Tooling Industry. voestalpine Böhler Welding

Lead Screws for Guided Munitions

Shell & Tube Heat-Exchangers

ISO INFORMATION ON TECHNICAL STANDARDISATION CHANGEOVER TO ISO

TQ 401 / EA 401 / IQS 451. Proximity System : TQ 401 Proximity Transducer EA 401 Extension Cable IQS 451 Signal Conditioner FEATURES

Infinitely Precise. micrometal. excellence in etching

Light Guide Overview

Our expertise your advantage. Machine knives and precision parts

Fast and flexible use Powerful results

HCS 1.5. The countersinkable compression screw.

Clamping bolts Eccentrical cams clamping units

Brazing Solutions for the Tooling Industry. voestalpine Böhler Welding

WORK SURFACE I highly recommend getting an Olfa knife. It is difficult to cut 1/2 foamcore with just an Exacto. RAZOR KNIFE CUTTING MAT WIRE CUTTERS

Assembly instructions

TQ 402 & TQ 412 / EA 402 / Proximity System : TQ 402 & TQ 412 Proximity Transducers EA 402 Extension Cable IQS 452 Signal Conditioner FEATURES

INNOVATION IN SPRING TECHNOLOGY.

Collection. For metal & acetate & injection frames. For metal & acetate & wood frames. For acetate & special material frames

25 mm 2 stranded 35 mm 2 flexible Aluminium cable

Contents. About company. Company s history. Company s views. DP Technologijos expanding products range and technologies Market segmentation

LESJÖFORS FLAT SPRINGS. The Lesjöfors Group also includes.

Porcelain Enamel Signs Tin Metal Signs

Apex & HA Apex Pins. Pin Fixation System. Half Pins, Transfixing Pins HA Coated Half Pins for long term fixation Instruments

FROM THE GLASS TUBE TO OPTIMUM SYSTEM PACKAGING

KWS Handrail Systems. Architectural Hardware

DOWEL & TAPER PINS. made by GREMAKO.

20 Flat Nose Pliers. 22 Round Nose Pliers ØD1 DIN ISO short, flat jaws serrated gripping surfaces special tool steel, oil-hardened and tempered

Pipe wrenches Tube cutters Bench yoke vices. Three stands Other plumbing tools Sets of pipe wrenches. Ergonomic shape

ET2C International. Low Cost Country Outsourcing/ Sub Contract Manufacture

KLEINER Stamping technology Assembly manufacturing

Door Hinges Drill-in Hinges

ASAHI Peripheral Guide Wire

STAINLESS STEEL PRODUCTS AND SERVICES

It s the small things in life that make the difference. We are in the job of making a difference. dietz.eu

Technique Guide. 7.0 mm Cannulated Screws. Part of the Synthes Cannulated Screw System.

Digital Compression Screw

Nondestructive measurement of layer thickness with the MIT-SCAN-T2

C A R D I O VA S C U L A R P R O D U C T S C ATA L O G

SITRANS F flowmeters SITRANS F M. Flow sensor MAG /48 Siemens FI Overview

CANADA S CUTTING EDGE

When Quality Counts we are Always One Step Ahead Simply The Finest

DISTAL RADIUS PLATES 3.5 mm / ANGULARLY STABLE. Distal radius plates 3,5 mm / angularly stable. Locking bone screws. Cortical bone screw

YOUR WORLDWIDE PARTNER FOR USED TRUMPF MACHINES

Expertise in Resistance Welding Machines

Transcription:

Medical Division Precision in diagnosis and therapy. Guide wires

Our guide wires are market leaders. Guide wires Guide wires, straight or with J-tip Size Outer Length Wire Core wire/ strip Core wire Distal end Dimension of strip Holding force diameter diameter diameter ground min..018 0,46 mm 220 2000 mm 0,08 mm Wire 0,25 mm 75/30 mm 8 N.020 0,51 mm 220 2000 mm 0,10 mm Wire 0,25 mm 75/30 mm 8 N.021 0,53 mm 220 2000 mm 0,10 mm Wire 0,25 mm 75/30 mm 8 N.024 0,60 mm 220 2000 mm 0,12 mm Wire 0,30 mm 75/30 mm 11 N.025 0,64 mm 220 2000 mm 0,12 mm Wire 0,30 mm 75/30 mm 11 N.028 0,71 mm 300 2000 mm 0,13 mm Wire 0,30 mm 75/30 mm 11 N.032 0,81 mm 300 2600 mm 0,16 mm Wire 0,30 mm 75/30 mm 11 N.035 0,89 mm 300 2600 mm 0,16 mm Wire + strip 0,40 mm 75/30 mm 0,08 x 0,25 mm 15 N.035 0,89 mm 300 2600 mm 0,16 mm Wire 0,43 mm 75/30 mm 15 N.038 0,97 mm 390 2600 mm 0,17 mm Wire + strip 0,43 mm 50/10 mm 0,08 x 0,25 mm 15 N.038 0,97 mm 300 2600 mm 0,17 mm Wire 0,48 mm 75/30 mm 15 N.045 1,14 mm 440 2600 mm 0,20 mm Wire + strip 0,48 mm 75/30 mm 0,08 x 0,25 mm 15 N Variations: J3-tip, proximal end flexible J3-HD, proximal end flexible without strip, welded on both ends Marking according to specification 100 1000 pcs. packed into polybags, non-sterile Core wire in stainless steel or Nitinol Optional: Loaded into dispenser PTA guide wires non-sterile Size Dimension J3/tip Reference No. Ident no. straight.035 0,89 x 1500 mm J3 FD035-1500-J3-PC 207217 straight FD035-1500-PC 207034.038 0,97 x 1500 mm J3 FD038-1500-J3-PC 207219 straight FD038-1500-PC 207036 all executions with proximal end stiff 100 1000 pcs. packed into polybags

Rely on us. PTCA wires PTCA wires non-sterile Type: Flexibility: Length A Ident no. Length B Ident no. FDO14 HF high floppy 208 601 208 628 FDO14 F FDO14 M FDO14 S FDO14 HS floppy medium stiff high stiff 208 600 208 602 208 605 208 606 208 629 208 630 208 631 208 632 FDO14 STF Stent, tip floppy 208 604 208 633 50 100 pcs. in plastic boxes Optional with bent tip Optional: Loaded into dispenser Full length tapered core for excellent pushability 1:1 transmission from the proximal end to the tip High mechanical performance by using laser-welding exclusively PTFE-coating on the shaft plus special coating of distal coil minimizes friction and provides excellent catheter movement Platinum Alloy of distal coil guarantees visibility during x-ray process. Moderate radiopacity of the shaft Gradual tapered tip section offers flexibilities from high floppy to high stiff Special wire with flexible tip to support stent placement Core Wire Layout HF / F / M / S / HS Flexibility STF Dimensions 1750/ 300 mm 30 mm 0.014 (0,36 mm)

Wire offers unlimited possibilities. Customer designed products Reinforcements for tracheal catheters Helix for cardial applications Urethral-prosthesis Stone basket Stone gripper Profound knowledge of precision work is the basis of subassemblies made of wire or strip. Prototypes and pre-series are made to sketch or even experimental data. We machine all stainless steel alloys according to DIN and AISI or common implantables. Healthcare is guaranteed by our high precision methods. Mainly the application of laser systems enables us to produce smooth surfaces in conjunction with low friction, high holding forces and physically acceptable proce dures. Minimal inventional procedures are therefore possible with the stone baskets, grippers and Lunderquist wires. The stiffness of the guide wires can be influenced by a flexible core wire. According to the situation the core wire can be pulled out and even the most difficult situations can be managed. The PTFE-layer of the core wire reduces friction to a minimum. Guide wire with movable core Guide wire according to Lunderquist

Reliability is born by competence. Medical Division Haas Quality is a tradition. Since 1904 the name of Carl Haas stands for high precision products. This knowledge is used in medical engineering intensively. We are concentrating on products made of wire and strips. Profit from our expertise. From raw material to the finished product everything is managed by us. State of art technologies such as laser welding are used in our manufacturing processes. Our knowledge and competence is the result of continuous improvement and guarantees the safe production and quality of Haas products. Reliable Quality. Our knowledge is recognized in medical engineering. In cardiology our products are used in diagnosis and therapy as well. What else can prove the reliability? Our quality management system is certified according to DIN EN ISO 9001 and DIN EN ISO 13485.

Carl Haas GmbH. A company of the KERN-LIEBERS Group. Companies of the KERN-LIEBERS Group Carl Haas GmbH P.O. Box 545 78707 Schramberg Dr. Konstantin-Hank-Str. 18 78713 Schramberg Telephone: 00 49 (0) 74 22/567-0 Fax: 00 49 (0) 74 22/567-239 info@carl-haas.de www.carl-haas.de