Ult r a s o n i c le v e l me t e r s ULM 70

Similar documents
ULTRASONIC LEVEL METERS ULM 70

Ultrasonic level meters ULM 70

ULTRASONIC LEVEL METERS ULM 53

Ult r a s o n i c le v e l me t e r s ULM 55

Ultrasonic level meters ULM 53

ULTRASONIC LEVEL METERS LU 55 INSTRUCTION MANUAL

Ultrasonic level meters ULM 53. instruction manual. průmyslová elektronika

MSLU Ultrasonic Level Meters

Ultrasonic Level Meter SLU

Capacitive level meters CLM 40 INSTRUCTIONS MANUAL. průmyslová elektronika

Submersible pressure sensor For oils and fuels Model LF-1

ED701 General Industry Pressure Transmitter

SATRON VB Pressure Transmitter

Mobrey Ultrasonic. MSP422, MSP400RH, and MSP900GH Level Transmitters. Product Data Sheet February 2015 IP2045, Rev EA

Capacitive level meters DLM 35 INSTRUCTION MANUAL. průmyslová elektronika

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

Submersible pressure sensor For water and wastewater Model LW-1

Intrinsically Safe Pressure Transmitter for highest pressure applications in hazardous environments Model IS-20-H

OPTIWAVE 7300 C Supplementary instructions

NUS-4. Ultrasonic Level Transmitter. for Liquids and Solids

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

Submersible pressure sensor For superior applications Model LF-1

Page Type Resolution (mm) min. max. Output

Transducer transmitter BILT 4 II 2(1) G. Technical Manual

Level Transmitter / Controller / Indicator. 3-in-1 package that is simple to install and use. With expanded ranges and improved chemical resistance.

Capacitive level meters DLM 35

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. appmeas.co.uk +44 (0)

LST400 Ultrasonic level / open channel flow transmitter

Radar level meters with guided wave EMKOTDR-60

Resistance Thermometers Model Series TR7X0, Sheathed Design

Resistance thermometer Model TR30, compact design

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Rosemount 3101, 3102, and 3105

Resistance thermometer Model TR30, compact design

Ultrasonic Level Transducer Type: MPUL06 Article No.: ca. 122

Rod probe With coaxial tube reference probe

Isolators Isolating Repeater Field Circuit Ex i ISpac 9165/ s Art. No

ABB MEASUREMENT & ANALYTICS DATA SHEET. Ultrasonic level LST400 Open channel flow transmitter

Intrinsically Safe Pressure Transmitter for applications in hazardous environments and shipbuilding industry Model IS-20-S, IS-21-S, IS-20-F, IS-21-F

prosonic T FMU230, FMU231

Relative and absolute pressure transmitter type 528

Ultrasonic level measuring device, non-contact

Intrinsically safe pressure transmitter MBS 4201, MBS 4251, MBS 4701 and MBS 4751

Installation instructions Dec. 2002

Ultrasonic level transmitter, non-contact

Technical Information Nivector FTC968, FTC968Z

Digital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version

Level Measurement. GDSL Series. Ultrasonic Level Sensor

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

Isolators A3/1. Vibration Transducer Supply Unit Series

Design and applications

Georg Fischer Piping Systems Point, Ultrasonic & Radar Level Products

6GHz Intelligent Radar Level Meter Product Manual. Model:KRD520 SERIES

SINEAX B 811 Power Pack with additional Functions

MP Series Radar Transmitter Installation & Operation Manual

Coriolis Massflowmeter

LST100 Ultrasonic level transmitter for upstream oil and gas

3DLevelScanner. Technical Data Sheet. Level Sensor. Non-Contact, Multiple-Point Measurement

SET Installation and Operating Instructions. Level switch for two sensors

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160

Expert 1400 / Expert 3400 Submersible Hydrostatic Level Transmitters

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Power supply. Calibration. Surface finishing. Seal. Process connection

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160 Rev. F

OEM radar transmitter, for aggressive media level measurement

INSTRUCTION MANUAL (ATEX / IECEx)

SINEAX TI 807 Passive DC signal isolator. SINEAX TI 807 Passive DC signal isolator

Level Measurement Continuous level measurement Radar transmitters

Operation. LEVEL Transmitters

Resistance thermometer Model TR30, compact design

SINEAX TI 807 Passive DC signal isolator

Analog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/

2-wire level transmitter

Analog Universal Module HART for Zone 2 Series 9468/33

SITRANS F flowmeters SITRANS F M. Flow sensor MAG /48 Siemens FI Overview

Digital temperature transmitter Model T15.H, head mounting version Model T15.R, rail mounting version

MJK Expert 700 / 800 / 900 / 1100 / 2100 MJK Expert 1400 / 3400

Digital inductive conductivity transmitter

Installation and maintenance manual. LSU 100, Ultrasonic level transmitter

Process transmitter Model UPT-20, with pressure port Model UPT-21, with flush diaphragm

Flow Measurement SITRANS F M. Flow sensor MAG /49. Overview

LEVEL Transmitters. SAP-300 display. Mono cable / Mono rod Mono segmented rod. Twin cable Twin rod Coaxial Pipe

The Radar Level Meters can be installed both in metallic or non metallic tanks; their use is not harmful to humans or environment.

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 20 ms. 60 ms. 60 ms. Approx. 1.3 kg. Approx. 0.9 kg. Approx. 5.

Digital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting

Coriolis Massflowmeter

Field indicator for current loops with HART communication Models DIH50, DIH52

Electrical Temperature Measurement

process measurement solutions Mobrey MSP IP wire 24V loop powered ultrasonic level transmitters

Level and Pressure. Product Information. Vibrating level switches

PiloTREK SZINTTÁVADÓK LEVEL TRANSMITTERS PU L S E BU RS T R A DA R LE V E L TR A NSMIT TERS K- BA N D R A DA R FO R LI Q U I DS

Type PLC Fitting. Valve for Continuous control. Diaphragm valve. Output

Pressure transmitter with flameproof enclosure For applications in explosion-protected areas Models E-10 and E-11

Ultrasonic Liquid Level Transmitters

Flow Measurement SITRANS F M

SITRANS T measuring instruments for temperature

MicroTREK GUIDED MICROWAVE LEVEL TRANSMITTERS

Isolators A3/1.

Installation guide 873 SmartRadar Control Unit & Antenna Unit

3DLevelScanner. Technical Data Sheet. Level Sensor. Non-Contact, Multiple-Point Measurement

Transcription:

preliminary data průmyslová elektronika Ult r a s o n i c le v e l me t e r s ULM 70 For continuous non-contact level measurement Suited to level measurement of various liquid and bulk-solid materials Outstanding contrast OLED display Easy adjustment without measured material Quick view measured values on the display Xi version for usage in explosive areas Current output (4... 20 ma) with HART communication protocol The ULM ultrasonic level meters are compact measurement devices including an electroacoustics converter, central processor unit and display module. Using the electroacoustics converter, the level meters transmit the sequence of ultrasonic pulses that spread towards the surface level. The converter recuperates reflected acoustic waves that are subsequently processed in the electronic module. The intelligent evaluation block filters out interfering signals, compares the cleaned received signal with the false reflection map (e.g. from mixers, ladders, reinforcement etc.) and selects a suitable reflection (echo). Based on the period during which the individual pulses spread towards the surface level and back and based on the measured temperature in the tank, the instant distance to the surface level is calculated. According to the level height, the level meter output is set and the measured value is displayed on the display. The level meters are suited to level measurement of various liquid materials, sewerage waters, mash and paste materials, suspensions in closed or open vessels, sumps, reservoirs and open channels. The level meters can continuously measure levels of bulk-solid materials with a low concentration of dust particles. Consult the manufacturer on recommended use of the level meter for bulk-solid materials. Features of variants ULM 70_ 02 Measuring range from 0.15 m to 2 m, plastic PVDF transmitter, mechanical connection with thread G 1". ULM 70_ 06 Measuring range from 0.25 m to 6 m, plastic PVDF transmitter, mechanical connection with thread G 1 ½". ULM 70_ 10 Measuring range from 0.4 m to 10 m, plastic PVDF transmitter, mechanical connection with HDPE polyethylene flange (version "N") or aluminium alloy flange (version "Xi"). Measuring range from 0.5 m to 20 m, plastic PVDF transmitter, mechanical connection with aluminium alloy flange. ULM-70-dat-1.6

Dimensional drawings ULM 70_ 02 ULM 70_ 06 Pg11 cable gland ground terminal ULM 70N 10 _ ULM 70Xi 10 I HDPE Al alloy _ Al alloy ULM-70-dat-2.6

Technical specifications Measuring range for liquids (bulk-solid materials) ULM 70_ 02 ULM 70_ 10 0.2... 2 m (0.2... 1 m) 0.25... 6 m (0.25... 3 m) 0.4... 10 m (0.4... 5 m) 0.5... 20 m (0.5... 10 m) Supply voltage Output Resolution ULM 70N ULM 70Xi 18... 36 V DC 18... 30 V DC 4... 20 ma (limit value 3.9... 20.5 ma), HART < 1 mm Accuracy (within the total range) 0,15% Temperature error max. 0.04% / K Beamwidth (-3 db) ULM 70_ 02 ; 10 10 14 12 Ambient temperature range ULM 70_ 02 ; 06 ULM 70_ 10 ; 20 Short-time temperature stress resistance Max. operation overpressure (on transmission surface) Sensitivity Damping Measuring period Delay between supply power rise time and first measurement Additional technical data 1) (only for variant Xi) Max. internal values Failure indication (echo loss, level in dead zone, internal failure) Protection class -30... +70 C -30... +60 C +90 C / 1 hour 0.1 MPa 3 steps (low medium high) 0... 99 sec. 1... 4 sec. 30 sec. U i =30V DC; I i =132mA; P i =0.99W; C i =370nF; L i =0.9mH Adjustable in modes: 3.75 ma ; 22 ma ; last measured value IP67 Mechanical connection ULM 70_ 02 ULM 70N 10 ULM 70Xi 10 screwing with thread G 1'' screwing with thread G 1½'' HDPE flange aluminium alloy flange aluminium alloy flange Recommended cable PVC 2 x 0.75 mm 2 (3 x 0.5 mm 2 ) Current output load resistance (U = 24 V DC) R max = 270 Ω 2) Weight ULM 70_ 02 ULM 70N 10 ULM 70Xi 10 0.3 kg 0.4 kg 0.7 kg 1.2 kg 3.1 kg Area classification (according to EN 60079-10 and EN 60079-14) ULM 70N ULM 70Xi 02 ULM 70Xi 06 ULM 70Xi 10 ULM 70Xi 20 Basic version for areas without risk of explosion Intrinsically safe version for areas with risk of explosion of flammable vapours or gases II 1/2G Ex ia IIB T5 with isolating repeater 3), the whole level meter zone 1, front head part zone 0 Intrinsically safe version for areas with risk of explosion of flammable vapours or gases II 1/2G Ex ia IIA T5 with isolating repeater 3), the whole level meter zone 1, front head part zone 0 Intrinsically safe version for areas with risk of explosion of flammable vapours or gases II 2G Ex ia IIA T5 with isolating repeater 3), the whole level meter zone 1 1) Allowed temp. range in the zone 0: -20 C... +60 C, Allowed press. range in the zone 0: 80... 110 kpa 2) Including 250R resistor in case of HART connection 3) e.g. Dinel IRU 420. ULM-70-dat-3.6

In s ta l l at i o n Level meter is installed into the upper lid of the tank (vessel), using a fixing nut or a flange. If installed in an open channel (sumps, reservoirs, etc.), install the level meter as closest as you can to the maximum level expected. The front of the level meter must be vertically to the measured level. Foam on the level absorbs the acoustic wave reflection which might cause malfunction of the level meter. If possible select the location where the foaming is as low as possible. Protect the level meter against direct sunlight. In the case of uncertainty we recommend to consult the application with the producer. Mounting recommendation ULM 70_ 02, 06 ULM 70_ 10 a < 3 b b > 100 mm a < 1,5 b b > 100 mm a < 1,5 b b > 150 mm a - neck height b - neck width m - dead zone Recommended installation Possible installation through the neck c - measuring range d - min. distance from tank wall (min. 200 mm) m - dead zone ULM 70_ 02,10 d > 1/12 c d > 1/8 c d > 1/10 c Installation distance from the tank wall Maximum level distance from ULM Electrical connection The ultrasonic level meter is designed to be connected to supply unit or to Metal clip controller through a cable with the outer diameter of 6 8 mm (recommended cross-section of cores 0.5-0.75 mm 2 ) by means of bolted clips placed under display module. Connect the plus Printed pole (+U) to the terminal "+", cicruit board the minus pole to 0V to the terminal "-" and the shielding to the terminal " " (only for shielded cables). Connection diagram of the level meter Internal view of terminal block Display unit connector Terminal block ULM-70-dat-4.6

With regard to possible occurrence of electrostatic charge on non-conductive parts of the level meter for explosive areas (Xi version) must be grounded with ground terminal! The power supply can be a stabilized voltage supply unit of 18 36V DC that is included in evaluation or display unit. In case of strong electromagnetic interference (EMI), parallel supply cable with power lines, or when the cable length exceeds 30 m, we recommend you to use a shielded cable. Always disconnect the supply voltage before connecting the level meter! Level meter setting Set the level meter using 3 buttons placed on the display module. All settings are accessible in the ULM-70 set-up mode access. For detailed information please read at the instructions manual. button Set-up mode access Confirmation of selected item in the menu Saving of set-up data Display of measured values button Move in the menu Change of values Set-up elements button Cancelling of carried out changes Shift one level up Teaching mode activation Echo receiving * Units * Slow flashing while the reflected signal (echo) is received from the measured level. Range of applications For continuous non-contact level measurement of liquids (water solutions, sewerage water, etc.), mash and paste materials (sediments, sticks, resins etc.) in closed or open vessels, sumps, reservoirs and open channels. The level meters can continuously measure levels of bulk-solid materials with a low concentration of dust particles. Consult the manufacturer on recommended use of the level meter for bulk-solid materials. Order code ULM 70 Output type: I - current Maximum range: Performance: 02-0.2... 2 m 06-0.25... 6 m 10-0.4... 10 m 20-0.5... 20 m N - normal - usable in non-explosive areas only Xi - Ex. proof - suitable for explosive areas Correct specification examples ULM 70N 02 I ULM 70Xi 06 I ULM 70N 10 I ULM 70Xi 20 I ULM-70-dat-5.6

Accessories Standard included in the price of the level meter Optional for extra charge 1x Seal (only for ULM 70_ 02, 06) Stainless fixing nut UM G1'' (for ULM 70_ 02) Stainless fixing nut UM G1 ½'' (for ) Safety, protection, compatibility and explosion proof The level meter ULM 70 is equipped with protection against reverse polarity and output current overload. Protection against dangerous contact is secured by low safety voltage that complies with EN 33 2000-4-41. EMC according to EN 55022/B, EN 61326/Z1 and EN 61000-4-2 to 6. Explosion proof of ULM 70Xi type complies with the following standards: EN 60079-0 : 2007; EN 60079-11 : 2007 ; EN 60079-26 : 2007 and examined by FTZÚ-AO 210 Ostrava - Radvanice certificate No.: FTZÚ 09 ATEX 0277X. version 01/2010 ULM-70-dat-6.6