Invertek Optidrive E3 Frequency Inverter (IP20, 3ph output) Easy Start Guide

Similar documents
The GS1 Digital Keypad LED Display Function Keys Displaying the Status of the GS1 AC Drive Programming the GS1 AC Drive...

TECO F510 Inverter. Quick Start Guide. Step 1. Supply & Motor connection

Before you operate the inverter, the parameters that you must first program are the basic parameters.

GS1 Parameter Summary Detailed Parameter Listings...4 9

CHAPTER KEYPAD OPERATION AND QUICKSTART. In This Chapter... The GS2 Digital Keypad GS2 Quickstart...3 6

HPVFP High Performance Full Function Vector Frequency Inverter

CHAPTER AC DRIVE PARAMETERS. In This Chapter...

User Guide. Optidrive Plus 3 GV Compact. OEM AC Variable Speed Drive kW (1 2HP) Installation and Operating Instructions

6.9 Jump frequency - Avoiding frequency resonance

NX series Constant and variable torque Variable Speed Drives for induction motors

D SERIES EM16 IP 20 / NEMA 1 & IP 66 / NEMA 4X COMPACT VECTOR CONTROL DRIVE EM 16 COMPACT VECTOR CONTROL DRIVE

User Guide. Optidrive Plus 3 GV Compact & Optidrive PCE. Compact AC Variable Speed Drive & Motor Mount Enclosure

NX Series Inverters. HVAC Pocket Programming Guide

vacon nx all in one application manual ac drives Phone: Fax: Web: -

TOSVERT TM VF-nC3 Parameter List

Quick Reference Guide. DF5-... Frequency Inverters 02/02 AWB GB

D SERIES LM16. COMPACT DRIVE V/f and SLV CONTROL. LM16 COMPACT DRIVE V/f and SLV CONTROL

MICROMASTER. Applications Handbook. User Documentation

Index 2. G Gain settings 4 31 Glossary of terms A 2 Grommets 2 13

NXL HVAC APPLICATION MANUAL Programming manual for NXL HVAC drives

SV9000 SVReady USER MANUAL CONTENTS OPEN SV9000 USER MANUAL. SV9000 Page 0-1

Siemens Standard Drives. Application Handbook

TAC ATV38, IP55. Variable Speed Drives for Asynchronous Motors. 3-phase. 380/460 V, Hz

FREQUENCY INVERTER VFR-013 QUICK START GUIDE

System Manual MOVITRAC LT E. Edition 04/2005 EA / EN

GB QUICK GUIDE FOR THE CONFIGURATION OF VARIABLE SPEED DRIVES

Operating Instructions

Comp-AC. User s Manual for type ACS 140 frequency converters from 0.12 to 2.2 kw

General Purpose Drives

Hitachi P1 Closed Loop Hoist Basic Instruc on Manual

Optidrive Applications Support Library

Quick Reference Guide. DF5-... Frequency Inverters 02/02 AWB GB. For Immediate Delivery call KMParts.com at (866)

The Drive & Control Company. Frequency Converter. VFC 3610 / VFC 5610 Series. Quick Start Guide R Edition 10

THYFREC-VT210S 400V System 37 to 315kW (C/T) 400V System 45 to 370kW (V/T) QUICK START GUIDE

THYFREC-VT110S 200V 1PH System 0.4 to 2.2kW 400V 3PH System 0.75 to 2.2kW QUICK START GUIDE

vacon nx ac drives all in one application manual

VFS9 Parameter List for Version110 or later

Multi-purpose Control Application II

EFC 3600 Frequency converter for higher energy efficiency and improved process control

user's manual nx frequency converters beam pump application asfiff13

The Drive & Control Company. Frequency Converter. VFC 3610 / VFC 5610 Series. Quick Start Guide R Edition 15

vacon 100 flow ac drives application manual

vacon 100 flow ac drives application manual

FUJI Inverter. Standard Specifications

ATV12H018F1 variable speed drive ATV kW hp V - 1ph

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink

This operation manual is intended for users with basic knowledge of electricity and electric devices.

Manual Overview...1 2

INDEX. i 1. B Braking Resistor Dimensions: A 24 Braking Resistors: A 20 Braking Units: A 20. DURAPULSE AC Drive User Manual

Multi-function, Compact Inverters. 3G3MV Series

Compact & Powerful Inverter STARVERT ig5a 0.4~1.5kW 1phase 200~230Volts 0.4~22kW 3Phase 200~230Volts 0.4~22kW 3Phase 380~480Volts

1-2 VOLTS PER HERTZ CHARACTERISTICS EXERCISE OBJECTIVE

KBDA SERIES STANDARD FEATURES DESCRIPTION PERFORMANCE FEATURES PROTECTION FEATURES

VFD Reference Guide. In-The-Field Tool

[ 4 ] Using pulse train input (F01 = 12)

General Purpose AC Drives

KBE2 DIGITAL AC ADJUSTABLE SPEED DRIVES

Variable Frequency Drive / Inverter (0.4 ~ 280kW)

Dual-inverter Wire Drawing Machine CHV130 series Frequency inverter Operation manual

MA7200 PLUS INVERTER SERIES PID Quick Start Manual For Fan and Pump Applications

CONTENTS CONTENTS...1 SAFETY PRECAUTIONS INTRODUCTION...4

Users Manual SM5 INVERTER. Subject to changes without notice December, 2001

E3 Adjustable Speed Drive Engineering Specification

safety Doc: DPD00714C, Released: vacon 1 ONLY A COMPETENT ELECTRICIAN IS ALLOWED TO CARRY OUT THE ELECTRICAL INSTALLATION! 1.

Frequency Converters for Speed Control of 0.55 to 4.0 kw Squirrel Cage Motors Supply Voltage 208 to 240 V 380 to 480 V User s Manual

NICE900 -Door Drive Setup Manual for Asynchronous / Synchronous Motor with Encoder Feedback (Document Release Dt ) Sr. No

Advanced user guide. Commander SX. IP66/Nema 4X AC Variable Speed Drive en / a. Part Number :

CHAPTER 5 DESCRIPTION OF PARAMETER SETTINGS

The Drive & Control Company. Frequency Converter. EFC 3610 / EFC 5610 Series. Quick Start Guide R Edition 12

Document number: Document version: r2 Date of release: Copyright Emotron AB 1998 Emotron AB reserves the right to alter product

NZV Series Sensorless Vector Control Inverter Operation Manual

ATV12HU40M3 variable speed drive ATV12-4kW - 5hp V - 3ph - with heat sink

VFD - D700 Series Specifications. The latest low-cost variable speed control solution for centrifugal pumps.

ADTECH Solar inverter

VF-nC1 Adjustable Speed Drive Engineering Specification

CHAPTER 5 DESCRIPTION OF PARAMETER SETTINGS

S11 Adjustable Speed Drive Engineering Specification

SE1 Microdrive User s Manual

SJ100 Series Inverter Quick Reference Guide. Single-phase Input 200V Class Three-phase Input 200V Class Three-phase Input 400V Class

Frequency Converter Fv vector control converters for universal applications

VFS11 Parameter List for up to CPU version 105

vacon nxs robust drive for heavy use

Goodrive inverter for air compressor. Preface

for Speed Control of 0.75 to 7.5 HP Induction Motors Supply Voltage 208 to 240 V 380 to 480 V Users Manual

Ambient Conditions Storage Conditions Installation Minimum Clearances and Air Flow...2 3

Siemens OPERATING INSTRUCTIONS FOR MICROMASTER ECO & MIDIMASTER ECO V1.19. Variable speed drive for Fans and Pumps (HVAC) from 0,75kW to 315kW

In the event of a failure, the inverter switches off and a fault code appears on the display.

Altivar 68 Telemecanique

user's manual nx frequency converters standard lift application asfiff08

VACON CX/CXL/CXS FREQUENCY CONVERTERS. Lift Application USER'S MANUAL. Subject to changes without notice

smd frequency inverter

ADJUSTABLE SPEED DRIVES VF-S11 Sords Electric

CHAPTER 8 PARAMETER SUMMARY

M-Max series drives. The next generation of OEM drives

DeviceCraft Revision #1 11/29/2010

CHAPTER MAINTENANCE AND TROUBLESHOOTING. In This Chapter... Maintenance and Inspection Troubleshooting...6 3

3. Be aware of the ambient temperature. Use the unit within the specified ambient temperature only.

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink

maxon motor maxon motor control 1-Q-EC Amplifier DEC 24/1 Order numbers , , , ,

Inverter Drive /Vector Drive Motors & Controls

Transcription:

Invertek Optidrive E3 Frequency Inverter (IP20, 3ph output) Easy Start Guide The Invertek Optidrive E3 Frequency Inverter range is available to order from inverterdrive.com This guide is intended to complement the user manual provided by the manufacturer. It is provided as a basic introduction to the product for Inverter Drive Supermarket customers. It should not be used as a replacement for the manual issued by the manufacturer. This product is not a safety device. All safety considerations including but not limited to Emergency Stop provision should be assessed separately and are outside the scope of this guide. Issue 1 20190107

Contents Page 1 Page 2 Page 3 Page 4 Page 5 Contents Power and Motor Connections (Single ) Power and Motor Connections (Three ) Motor Connections - Star and Delta Parameters - Overview Parameters to set before use Page 6 Page 7 Page 8 Page 9 Page 10 Page 11 Page 12 Page 13 Page 14 How to set a Parameter value How to Operate the Inverter from the keypad How to enable/disable Sensorless Vector mode How to connect and configure a Potentiometer for remote speed control How to connect and configure a Run Forward or Run Reverse switch How to connect and configure a Run/Stop switch with Forward/Reverse selection How to configure 3-Wire control with Run Forward Run Reverse and Stop pushbuttons Brake Resistor Connection (size 2 and above) How to Reset the Inverter to Factory Defaults Page 1

1. Power and Motor Connections (Single ) SUPPLY (Earth) L1/L (Live) L2/N (Neutral) Before commencing, confirm that the Inverter and all cables are completely isolated from the power supply, have been isolated for at least 5 minutes and that the motor is not turning. Notes: The illustration on the left is based on frame size 1 (ratings to 1.5kW). The terminal layout for frames 2-3 is similar. Filtered models are supplied with the internal EMC filter enabled. This can be disabled by removing the screw on the side of the unit marked EMC (not usually necessary). The order of the three motor phases determines the initial direction the motor turns. This can be reversed by physically swapping any two phases, or by changing the Inverter parameters. Use screened cable between the Inverter and Motor. To minimise electromagnetic interference, ensure the cable screen is grounded. The supply must match the Inverter specification. (Earth) (Screen) MOTOR U, V, W (s) Page 2

2. Power and Motor Connections (Three ) SUPPLY (Earth) Before commencing, confirm that the Inverter and all cables are completely isolated from the power supply, have been isolated for at least 5 minutes and that the motor is not turning. Notes: The illustration on the left is based on frame size 1 (ratings to 1.5kW). The terminal layout for frames 2-4 is similar. The order of the three supply phases is not important. The order of the three motor phases determines the initial direction the motor turns. This can be reversed by physically swapping any two motor phases. Or by changing the Inverter parameters. Use screened or armoured cable between the Inverter and Motor. To minimise electromagnetic interference, ensure the cable screen is grounded. The supply must match the Inverter specification. (Earth) (Screen) MOTOR U, V, W (s) Page 3

3. Motor Connections - Star and Delta Dual voltage induction motors typically include terminal boxes with six points. The points can be connected together with links in one of two ways to suit one of the two rated voltages. The two ways of connecting the links are shown below. These are known as Star (the higher voltage) or Delta (the lower voltage). The selection of Star or Delta is not optional and must match the supply voltage. Dual voltage motor nameplates include symbols to represent voltage and full load current in each configuration. Delta is represented by a triangle and star by a Y (Wye). Link Link STAR Earth Screen DELTA Earth 3.1 Motor connected in STAR (or Wye): For safety purposes, Star (shown opposite) is the default configuration for small motors (usually to 3kW) and is sometimes known as two at one side. Only two links are required for Star. Double-up the links if changing from Delta to allow the motor to be changed back in future. The order of the three phases determines the direction the motor turns. Note that the manufacturer recommends that the cable screen is earthed at both ends. 3.2 Motor connected in DELTA: The link configuration is shown in the illustration opposite and is sometimes referred to as three-a-breast. The order of the three phases determines the direction the motor turns. Note that the manufacturer recommends that the cable screen is earthed at both ends. Screen Page 4

4. Parameters - overview The Inverter contains a number of settings which can be changed to tailor it for use in a wide range of applications. These settings are known as parameters. Parameters are typically referred to by code or number (eg. P-08 = Motor Rated Current) with a description available in the manual. 5. Parameters to set before use Set the following parameters to allow the Optidrive to control a motor with Run, Stop and Speed Control from the keypad. Parameter Description How to set The parameters contain critical information essential to the correct operation of the Inverter. Therefore, they should at least be checked by the user before the Inverter is operated for the first time. The parameters listed in section 5 are intended to provide a starting point to allow for basic operation of the Optidrive Inverter. See section 6 to learn how to set a parameter value. 5.1 Parameters to check and values to set If any of the parameters have been changed previously, follow the procedure in section 14 to reset the Inverter to Factory Defaults. P-01 Maximum Frequency (Hz) Maximum frequency for the Inverter. Default is 50 which suits many applications. P-02 Minimum Frequency (Hz) Minimum frequency for the Inverter. Default is 0; 3 suits many applications. P-03 First Acceleration Time (s) Default is 5 seconds; increase or decrease if faster or slower acceleration is required. P-04 First Deceleration Time (s) Default is 5 seconds; increase or decrease if faster or slower deceleration is required. P-05 Stopping Mode Default is 0, ramped stop. Change to 1 for coast stop; this may suit some fan loads. P-07 Motor Rated Voltage (V) Rated Voltage of the motor. Set to match the motor nameplate eg 230 V P-08 Motor Rated Current (A) Rated current of the motor. Set to match the motor nameplate eg 2.4 A P-09 Motor Rated Frequency (Hz) Rated frequency of the motor. Default is 50 Hz; change to suit the motor. P-10 Motor Rated Speed (rpm) Rated rpm of the motor. Set to match the motor nameplate eg 1460 rpm (min-1) P-11 Low Frequency Torque Boost (%) Default is rating dependent. Can be increased to improve low speed torque performance if required. P-12 Primary Command Source Default is 0 for terminal control. For keypad or PID control selection is required. P-13 Operating Application Type Default is 0 (constant torque); can be set to 1 for centrifugal pump or 2 for fan applications. P-14 Extended Menu Access Code Default is 0. Set to 101 to gain access to extended parameters (P-15 to P-50). Set to 201 to gain access to extended and advanced parameters (P-15 to P-60). P-15 Digital Input Function Selection (Extended Access Required) Default is 0; will suit most applications. 17 different Macros available. Defaults given in this guide are based on P-15 = 0 (default). P-17 Switching Frequency (Extended Access Required) Default is 8kHz. Only change if required; default will suit most applications. Note: each Optidrive E3 includes a pull-out reference card (marked ). This contains details of parameters P-01 to P-14 and the default control terminal configuration. Page 5

6. How to set a Parameter value 6.1 Press the navigation key to access parameters. When powered up the Optidrive default display is Stop. To access the parameter list press and hold the navigation key for approx. 2 seconds. P-01 or the last viewed parameter will be displayed with the last digit flashing. 6.2 Select the required parameter. Use the up and down arrow keys to select the required parameter. In this example, select P-08 (Motor Rated Current). Note: By default, parameters P-01 to P-14 will be visible. To enable extended parameters (P-15 to P- 50) set P-14 to 101. For advanced parameters (P-15 to P-60) set P-14 to 201. 6.3 Change the parameter value and save. Press the navigation key to show the parameter value. Use the up and down arrows keys to change the value as required. Press the navigation key return to the parameter list. to save the changes and 6.4 Return to the main operating display. Once all parameter changes are complete press and hold the navigation key for approx. 2 seconds to return to the main operating display. Note: The parameter list or value will automatically return to the main operating display after approx. 20 seconds of inactivity. Any unsaved changes will be lost. Page 6

7. How to operate the Inverter from the keypad 7.1 Select local control mode. As default, the Optidrive E3 is set to operate from the integrated IO terminals. To operate from the keypad, the Optidrive needs to be set to local control. To do this, change parameter P-12 from 0 to 1. Terminals 1 and 2 must also be linked to enable the Inverter (as shown, right). Link 7.2 Set the desired speed. Press the red stop key. The set point value in Hz will be displayed (the default value is 0.0). Use the up and down keys to change the value as required. This value can set to any value between the minimum (P-02) and maximum (P-01) frequencies. 7.3 Press the green RUN key to start the motor. The green key will start the motor. The display will increase from 0.0 as the motor accelerates. The time taken for the motor to accelerate to the desired speed (in seconds) is proportional to parameter P-03. To change the speed whilst the motor is running, use the up and down keys. Note: When running, the navigation key can be used to cycle through status values such as current in Amps (A) and Power in kw (P). 7.4 Press the red Stop key to stop the motor. The red key will stop the motor. The time taken (in seconds) to stop the motor is proportional to parameter P-04. Once the motor is stopped, the display will show StoP. Note: Once the desired speed has been set the start and stop keys will run the motor to/from this value even if the drive is power-cycled. Page 7

8. How to enable/disable Sensorless Vector mode The standard motor control mode of the Optidrive E3 is Sensorless Vector. By default, the E3 uses the motor parameters for this mode. However, low-speed torque can be improved further by performing an Autotune. The Autotune process improves performance by building a model of the motor. This requires the Inverter to operate the motor for a few seconds to gather the necessary data. To fully enable Sensorless Vector control by performing an Autotune, first set the parameter values specified in 8.1 (below) and then complete the steps described in 8.2 and 8.3. If Sensorless Vector control is not desired, change parameter P-51 from 0 to 1 to disable Sensorless Vector control and set the motor control mode to simple V/f. 8.1 Parameters to check prior to an Autotune. Parameter Description How to set P-14 Extended Menu Access Code Default is 0; set to 201 to gain access to advanced parameters (P-15 to P-60). P-07 Motor Rated Voltage (V) Rated Voltage of the motor. Set to match the motor nameplate eg 230 V P-08 Motor Rated Current (A) Rated current of the motor. Set to match the motor nameplate eg 2.4 A P-09 Motor Rated Frequency (Hz) Rated frequency of the motor. Default is 50 Hz; change to suit the motor. P-10 Motor Rated Speed (rpm) Rated rpm of the motor. Set to match the motor nameplate eg 1460 rpm (min-1) P-51 Motor Control Mode Default is 0 for (Sensorless) Vector Control Mode. Default is required for this example. To disable Sensorless Vector mode set to 1 to change to simple V/f mode. 8.2 Start Autotune. Once the parameters in 8.1 have been set, select parameter P-52 and press the navigate key to edit the value. Use the up and down keys to change the value from 0 to 1 then press the navigate key again to start the Autotune. 8.3 The Autotune process. There is no visible indication that an Autotune is in progress but motor excitation noise will be heard for a few seconds whilst the required values are measured. When complete, the value of P-52 will return to 0. Press and hold the navigate key for approx. 2 seconds to return to the main operating display. Page 8

9. How to connect and configure a Potentiometer for remote speed control If speed control via the integrated keypad is unsuitable for the application, a remote Potentiometer can be used instead. This provides the benefit of allowing motor speed to be controlled from a more convenient location such as a cabinet door (if the Optidrive is cabinet-mounted) or on the machine itself. Any potentiometer rated from 1kOhm to 10kOhm can be used. The number of turns depends on the application. Both single and multiturn Potentiometers are available from The Inverter Drive Supermarket at InverterDrive.com. 9.1 Parameters to check for remote Potentiometer speed control Parameter Description How to set P-14 Extended Menu Access Code Default is 0; set to 101 to gain access to extended parameters (P-15 to P-50). P-16 Analogue Input 1 Signal Format Default is U0-10 (0 to 10V). Default is required for this example. +10V AI1 0V 9.2 Connecting the Potentiometer 3 2 1 A wiring diagram is shown in the illustration opposite. The most important connection at the Potentiometer end is the centre terminal or wiper. The wiper will output a variable voltage between 0 and 10 Volts and should be connected to the AI1" terminal on the Inverter. It is this voltage which provides the speed signal with 0V being slowest and 10V fastest. Screen to Earth Terminal Screened Cable The default output frequency at 0V is the minimum frequency of the Inverter. To change this, edit parameter P-02. The default output frequency at 10V is 50Hz. To change this, edit parameter P-01. 1 2 3 If the rotation of the Potentiometer is the opposite to that required (ie. turn anticlockwise to increase speed instead of clockwise) reverse connections GND and 10V. Use shielded cable between Potentiometer and Inverter and ensure that the cable screen is connected to the Inverter earth terminal only. 10kOhm Potentiometer [Order Code 21302] Page 9

10. How to connect and configure a Run Forward or Run Reverse switch The procedure described in section 7 enables Run/Stop operation via the start and stop buttons on the Inverter keypad. If this is unsuitable for the application, a remote switch can be used instead. 10.1 Parameters to check for remote Run/Stop Parameter Description How to set This section explains how to enable 2-wire control with Run Forward / Stop / Run Reverse commands via a single selector switch. When set to operate in this way, the Inverter can no longer be operated via the integrated keypad. P-12 Primary Command Source Default is 0 for terminal control. Default is required for this example. P-14 Extended Menu Access Code Default is 0; set to 101 to gain access to extended parameters (P-15 to P-50). P-15 Digital Input Function Selection (Extended Access Required) Default is 0; set to 5 to select run fwd/run rev control. This value can be set to 0 if reverse is not required and a 2 position switch will be used. +24V DI1 DI2 10.2 Connecting the Switch 2 3 1 A wiring diagram is shown in the illustration opposite. A suitable 3 position NO (Normally Open) switch should be installed between terminals 24V, DI1 and DI2. The centre position should remain open circuit. When a connection is made between terminals 24V and DI1, the motor will run forward. When terminals 24V and DI2 are connected, the motor will run in reverse. R 1 2 3 F If terminals DI1 and DI2 are connected to 24V at the same time the motor will stop. Parameter P-24 can be used to set the time to stop in seconds. Switch, 3 Position Normally Open Run Forward / Stop / Run Reverse Page 10

11. How to connect and configure a Run/Stop switch with Forward/Reverse selection The procedure described in section 7 enables Run/Stop operation via the start and stop buttons on the Inverter keypad. If this is unsuitable for the application, remote switches can be used instead. 11.1 Parameters to check for remote Run/Stop Parameter Description How to set This section explains how to enable 2-wire control with Run/Stop and Forward/Reverse commands via separate selector switches. When set to operate in this way, the Inverter can no longer be operated via the integrated keypad. P-12 Primary Command Source Default is 0 for terminal control. Default is required for this example. P-14 Extended Menu Access Code Default is 0; set to 101 to gain access to extended parameters (P-15 to P-50). P-15 Digital Input Function Selection (Extended Access Required) Default is 0; default is required for this example. +24V DI1 DI2 11.2 Connecting the Switches 1 2 3 A wiring diagram is shown in the illustration opposite. Two suitable 2 position NO (Normally Open) switches should be installed: One between terminals 24V and DI1 (Run / Stop) and the other between terminals 24V and DI2 (Forward / Reverse). 1 2 1 3 R Note that the Forward/Reverse switch only selects the direction of rotation - it will not start or stop the motor. The direction can be set either before the motor is started or whilst it is running. If the application only requires the motor to turn in one direction, the Forward/Reverse switch can be omitted. Switch, 2 Position Normally Open Run / Stop Switch, 2 Position Normally Open Forward / Reverse Page 11

12. How to configure 3-Wire control with Run Forward Run Reverse and Stop pushbuttons The procedure described in section 7 enables Run/Stop operation via the start and stop buttons on the Inverter keypad. If this is unsuitable for the application, remote switches can be used instead. 12.1 Parameters to check for remote 3-wire control Parameter Description How to set This section explains how to enable 3-wire control with Run Forward, Run Reverse and Stop commands via separate pushbuttons. When set to operate in this way, the Inverter can no longer be operated via the integrated keypad. P-12 Primary Command Source Default is 0 for terminal control. Default is required for this example. P-14 Extended Menu Access Code Default is 0; set to 101 to gain access to extended parameters (P-15 to P-50). P-15 Digital Input Function Selection (Extended Access Required) Default is 0; set to 11 for 3 wire control. +24V DI1 DI2 DI3 12.2 Connecting the Switches 1 2 3 4 1 2 13 1 4 A wiring diagram is shown in the illustration opposite. Three suitable pushbuttons should be installed:- Stop: a normally closed contact between terminals +24V and DI1 Run Forward: a normally open contact between terminals +24V and DI2. Run Reverse: a normally open contact between terminals +24V and DI3. A momentary connection between +24V and DI2 will start the motor (forward). It will continue to run until the connection between +24V and DI2 is broken. A momentary connection between +24V and DI3 will behave in the same way but the motor will run in reverse. Pushbutton Normally Open Run Forward Pushbutton Normally Closed Stop Pushbutton Normally Open Run Reverse If the application only requires the motor to turn in one direction, the Run Reverse pushbutton can be omitted. Page 12

13. Brake Resistor Connection (size 2 and above) Before commencing, confirm that the Inverter and all cables are completely isolated from the power supply, have been isolated for at least 5 minutes and that the motor is not turning. High inertia loads can cause overvoltage trips during deceleration and lead to O-Volt" error messages. In many cases, the solution is to increase the deceleration time to compensate. A Brake Resistor is first installed to absorb braking energy and dissipate it as heat. The resistor must be correctly sized for both the Inverter and application. However, if the application requires it, dynamic braking can be enabled to maintain or reduce deceleration times by absorbing the energy generated by such loads. 13.1 Parameters to check for Dynamic Braking Parameter Description How to set The brake chopper within the Inverter detects excessive braking energy and redirects it to the resistor when required. P-14 Extended Menu Access Code Default is 0; set to 101 to gain access to extended parameters (P-15 to P-50). P-34 Brake Chopper Enable (Extended Access Required) Default is 0; set to 3 for Enabled With Software Protection to suit most applications. 13.2 Connecting the Resistor A wiring diagram is shown in the illustration opposite. Connect the brake resistor to the + and BR terminals on the Inverter. The order of the connections is unimportant. The braking resistor may get hot during operation. Ensure that it is suitably-mounted so any heat generated will not affect other equipment. Some resistors may include a thermal relay for additional protection. + BR BR + It is essential that a resistor of the correct rating is used. Consult the Inverter product listing at InverterDrive.com or manual issued by the manufacturer for details. Heat Resistant Cable Page 13

14. How to reset the Inverter to Factory Defaults 14.1 Three Button Reset To reset all parameters to their factory default values, press and hold the up, down and stop keys together for approx. 2 seconds. The display will show P-dEF to indicate Parameter Defaults. 14.2 Confirm the Reset Press the red stop key to confirm the reset. The display will show StoP indicating that the process is complete. 14.3 Enable Extended or Advanced Parameters (optional) Parameters above P-14 will not be visible once a factory reset has been completed. If access to extended parameters (P-15 to P-50) is required, set P-14 to 101. For advanced parameters (P- 15 to P-60) set P-14 to 201. Note: see section 6 to learn how to set a parameter value. Page 14