Creating an urban street reverberation map

Similar documents
Validation of lateral fraction results in room acoustic measurements

Meteorological influence on sound propagation between adjacent city canyons: A real-life experiment

A cellular automaton for urban traffic noise

19 th INTERNATIONAL CONGRESS ON ACOUSTICS MADRID, 2-7 SEPTEMBER 2007 TRANSPARENT CONCERT HALL ACOUSTICS

EFFECT OF STIMULUS SPEED ERROR ON MEASURED ROOM ACOUSTIC PARAMETERS

SMART CITIES AND INDUSTRY 4.0 RESEARCH AT UGENT - WAVES. Prof. Dr. ir. Dick Botteldooren

Estimation of Reverberation Time from Binaural Signals Without Using Controlled Excitation

Characterisation of noise in homes affected by wind turbine noise

Experimental study of traffic noise and human response in an urban area: deviations from standard annoyance predictions

Reverberation time and structure loss factor

Revision of ISO Standards on field sound insulation testing. Carl Hopkins

ODEON APPLICATION NOTE Calculation of Speech Transmission Index in rooms

STUDIES OF EPIDAURUS WITH A HYBRID ROOM ACOUSTICS MODELLING METHOD

Characterisation of noise in homes affected by wind turbine noise

Psychoacoustic Cues in Room Size Perception

DESIGN OF VOICE ALARM SYSTEMS FOR TRAFFIC TUNNELS: OPTIMISATION OF SPEECH INTELLIGIBILITY

The effects of the excitation source directivity on some room acoustic descriptors obtained from impulse response measurements

ACOUSTICAL COMPUTER SIMULATIONS OF THE ANCIENT ROMAN THEATRES

Low frequency sound reproduction in irregular rooms using CABS (Control Acoustic Bass System) Celestinos, Adrian; Nielsen, Sofus Birkedal

Advanced techniques for the determination of sound spatialization in Italian Opera Theatres

SOUND FIELD MEASUREMENTS INSIDE A REVERBERANT ROOM BY MEANS OF A NEW 3D METHOD AND COMPARISON WITH FEM MODEL

Environmental noise mapping study for heterogeneous traffic conditions

ECMA-108. Measurement of Highfrequency. emitted by Information Technology and Telecommunications Equipment. 4 th Edition / December 2008

SIA Software Company, Inc.

Trials of a mobile MLS technique for characterising road surface absorption. Abstract

Acoustical Active Noise Control

Technique for the Derivation of Wide Band Room Impulse Response

EBU UER. european broadcasting union. Listening conditions for the assessment of sound programme material. Supplement 1.

STUDIO ACUSTICUM A CONCERT HALL WITH VARIABLE VOLUME

THE USE OF VOLUME VELOCITY SOURCE IN TRANSFER MEASUREMENTS

Investigation of Noise Spectrum Characteristics for an Evaluation of Railway Noise Barriers

ECMA-108. Measurement of Highfrequency. emitted by Information Technology and Telecommunications Equipment. 5 th Edition / December 2010

Simulation and auralization of broadband room impulse responses

The vibration transmission loss at junctions including a column

ODEON APPLICATION NOTE ISO Open plan offices Part 2 Measurements

Convention e-brief 310

Adaptive Filters Application of Linear Prediction

ASSESSMENT AND PREDICTION OF STRUCTURE-BORNE RAIL NOISE IN DOMESTIC DWELLINGS

International Journal of Technical Research and Applications e-issn: , Volume 3, Issue 4 (July-August 2015), PP.

Audio Engineering Society. Convention Paper. Presented at the 115th Convention 2003 October New York, New York

An experimental evaluation of a new approach to aircraft noise modelling

WITHIN GENERATOR APPLICATIONS

Convention Paper Presented at the 130th Convention 2011 May London, UK

Reducing the influence of microphone errors on in- situ ground impedance measurements

ROOM SHAPE AND SIZE ESTIMATION USING DIRECTIONAL IMPULSE RESPONSE MEASUREMENTS

inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE

EFFECT OF ARTIFICIAL MOUTH SIZE ON SPEECH TRANSMISSION INDEX. Ken Stewart and Densil Cabrera

Spatialisation accuracy of a Virtual Performance System

MEASURING SOUND INSULATION OF BUILDING FAÇADES: INTERFERENCE EFFECTS, AND REPRODUCIBILITY

Influence of ground reflections and loudspeaker directivity on measurements of in-situ sound absorption

Investigating the acoustics of ancient theatres by means of a modular scale model

PRODUCT DATA. DIRAC Room Acoustics Software Type Photo courtesy of Muziekcentrum Frits Philips, Eindhoven, The Netherlands

Airborne Sound Insulation

29th TONMEISTERTAGUNG VDT INTERNATIONAL CONVENTION, November 2016

A3D Contiguous time-frequency energized sound-field: reflection-free listening space supports integration in audiology

Do wavelet filters provide more accurate estimates of reverberation times at low frequencies.

PRODUCT DATA. Applications. Uses

THE ATTENUATION OF NOISE ENTERING BUILDINGS USING QUARTER- WAVE RESONATORS: RESULTS FROM A FULL SCALE PROTOTYPE. C.D.Field and F.R.

IS SII BETTER THAN STI AT RECOGNISING THE EFFECTS OF POOR TONAL BALANCE ON INTELLIGIBILITY?

Holographic Measurement of the Acoustical 3D Output by Near Field Scanning by Dave Logan, Wolfgang Klippel, Christian Bellmann, Daniel Knobloch

Proceedings of Meetings on Acoustics

Noise and vibration generation for laboratory studies on sleep disturbance

Analysis of room transfer function and reverberant signal statistics

Experimental Investigation on the Effect of Origami Geometry on the Acoustic Characteristics

In situ assessment of the normal incidence sound absorption coefficient of asphalt mixtures with a new impedance tube

AN AUDITORILY MOTIVATED ANALYSIS METHOD FOR ROOM IMPULSE RESPONSES

Predictions and measurements for lightweight constructions and low frequencies C. Guigou-Carter, M. Villot CSTB

Three-dimensional sound field simulation using the immersive auditory display system Sound Cask for stage acoustics

Characterization of Train-Track Interactions based on Axle Box Acceleration Measurements for Normal Track and Turnout Passages

Considerations in characterising an almost anechoic room for interactive spatial audio reproduction

Contact person Date Reference Page Joachim Stadig P (7) Building Technology

ON WAVEFORM SELECTION IN A TIME VARYING SONAR ENVIRONMENT

Acoustic effects of platform screen doors in underground stations

ACOUSTIC BARRIER FOR TRANSFORMER NOISE. Ruisen Ming. SVT Engineering Consultants, Leederville, WA 6007, Australia

Railscan: A Tool for the Detection and Quantification of Rail Corrugation

Jurnal Teknologi THE ACOUSTIC EFFECTS OF THE AUDIENCE IN THE MODERN USE THE OF ANCIENT THEATRES. Full Paper. Gino Iannace *, Amelia Trematerra

Case study for voice amplification in a highly absorptive conference room using negative absorption tuning by the YAMAHA Active Field Control system

PRODUCT DATA. DIRAC Room Acoustics Software Type 7841

Acoustics `17 Boston

1319. A new method for spectral analysis of non-stationary signals from impact tests

inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE

Proceedings of Meetings on Acoustics

Signal Detection with EM1 Receivers

IE-35 & IE-45 RT-60 Manual October, RT 60 Manual. for the IE-35 & IE-45. Copyright 2007 Ivie Technologies Inc. Lehi, UT. Printed in U.S.A.

THE ACOUSTICS OF A MULTIPURPOSE CULTURAL HALL

PREDICTING SOUND LEVELS BEHIND BUILDINGS - HOW MANY REFLECTIONS SHOULD I USE? Apex Acoustics Ltd, Gateshead, UK

MEASURING DIRECTIVITIES OF NATURAL SOUND SOURCES WITH A SPHERICAL MICROPHONE ARRAY

Influence of artificial mouth s directivity in determining Speech Transmission Index

PRODUCT DATA USES. BENEFITS Normal incidence parameters are determined Fast and accurate measurements. Type 4206A. Type Type 4206T 50 Hz 1.

Modal Parameter Estimation Using Acoustic Modal Analysis

Fundamentals of Environmental Noise Monitoring CENAC

Lion s Gate Secondary Wastewater Treatment Plant Pile Driving North Vancouver, BC. Final Report Rev 1

CHAPTER 3 THE DESIGN OF TRANSMISSION LOSS SUITE AND EXPERIMENTAL DETAILS

Convention Paper 6274 Presented at the 117th Convention 2004 October San Francisco, CA, USA

Performance of Roadside Sound Barriers with Sound Absorbing Edges

Façade insulation at low frequencies influence of room acoustic properties

From concert halls to noise barriers : attenuation from interference gratings

IS INTERNATIONAL STANDARD. Acoustics - Attenuation of sound during propagation outdoors - Part 2: General method of calculation

9LEUDWLRQ 0HDVXUHPHQW DQG $QDO\VLV

Technical Note 2. Standards-compliant test of non-ionizing electromagnetic radiation on radar equipment

Transcription:

Creating an urban street reverberation map P. Thomas, E. De Boeck, L. Dragonetti, T. Van Renterghem and D. Botteldooren Pieter.Thomas@intec.ugent.be Department of Information Technology (INTEC), Ghent University, St. Pietersnieuwstraat 4, B-9 Gent, Belgium Summary Reverberation increases sound levels in streets and aversely influences the perceived sound field quality. To assess this, it is studied if "reverberation maps" could be useful. Knowledge on street reverberation could be used as a valuable alternative to physical methods such as ray tracing, beam tracing etc. to obtain an estimate of expected noise levels and sound quality indicators. But also on itself, a map showing the reverberation times of the streets could be very informative. In this work a reverberation map of some neighborhoods in Ghent, Belgium, is produced. To enable fast determination of EDT and T 3 on different positions in a multitude of streets, a dedicated measurement set-up is mounted on the roof of a car. It is investigated to what extend interpolation between measurement points and extrapolation to other areas is possible on the basis of the geometry and architectural aspects of the street and surrounding buildings, features that are available from geographical information layers. PACS no. 43.5.Rq, 43.55.-n. Introduction Large percentages of the urban population are exposed to high traffic noise levels, causing annoyance[], sleep disturbance[] and other negative health impacts[3]. To estimate noise exposure, noise maps are a useful tool. Typically, noise maps are estimates of the long-term averaged noise levels and are commonly based on numerical calculations using geometrical acoustics. In a highly complex city lay-out, a high number of sound reflections occur, which have to be taken into account when accurately predicting the noise level. However, the maximum number of reflections is chosen to be low and fixed to limit computation times. In this way accuracy is lost as the noise level is only calculated based on the first few reflections. To have an estimate of the influence of later reflections, knowledge of the reverberation time EDT and T 3 could be of help. Furthermore, as these parameters describe the sound energy decay, a map depicting the reverberation time in the city-streets, combined with knowledge on the traffic pass-by and noise sources in those streets, is most useful to identify problem cases. Other parameters related to room acoustics could also be used. Examples are center time T s, which (c) European Acoustics Association indicates the point of gravity of the impulse response energy, and clarity C 8, which gives the ratio of early sound energy to reverberant sound energy[4]. Measurements of such parameters are based on an in-situ measurement of the impulse response[5]. In order to obtain a high number of impulse response measurements in a reasonable time, a dedicated measurement set-up is proposed, which allows fast and mobile measurements of the impulse response and reverberation time in streets. However, even the measurement of the impulse responses with the mobile measurement system is time consuming. It thus remains difficult to measure the impulse response of a high number of locations in a multitude of streets, prior to the construction of a noise map. Therefore it will be checked if a correlation can be found between different geometrical and architectural properties and acoustical parameters.. Measurement set-up The determination of the acoustic parameters is based on in-situ measurements of the impulse response. For these impulse response measurements an omnidirectional loudspeaker is needed, which reproduces an excitation signal. The response to this signal is then recorded by one or more omnidirectional microphones. As these measurements have to be conducted on a multitude of different positions, while the urban traffic should be disturbed as little as possible, the set-up

FORUM ACUSTICUM 7. June -. July, Aalborg crossing point between the decaying slope and averaged noise level of the time-averaged band response[6]. From the processed band levelfunctions the reverberation time can then be calculated by using the slope of the best fitted line between [ db, db] for EDT and [ 5 db, 35 db] for T 3... Influence of the car Figure. Mobile measurement set-up. An omnidirectional speaker is mounted on the roof of a car. An omnidirectional microphone Type 489 of Bruël & Kjær is mounted in front and behind the speaker at.5 m distance. should enable both mobile and fast measurements. For this reason it is decided to build the set-up with omnidirectional speaker and microphones on the roof of a car. The loudspeaker is placed near the middle of the roof, while two Bruël & Kjær omnidirectional microphones Type 489 are placed at a distance of.5 m at both sides of the speaker (fig. ). In this way, two impulse response measurements can be conducted simultaneously. The excitation signal used for the measurements is an exponential sweep of 3 s and covers the 63 Hz to 6 khz octave band. With this test signal, each frequency is excitated at a different moment in time, while each octave band contains an equal amount of energy. This measurement cycle is repeated minimum three times at each location. In this way disturbed measurements can be filtered out. While performing the measurements, the position in the street is logged and architectural aspects are noted. The street geometry (length, and height) was found in GIS databases... Signal processing From the recorded sweep the impulse response can be extracted by spectral division with the emitted sweep. The resulting impulse response is analyzed in octave bands and for each band filtered impulse response a levelfunction is calculated, describing the energy decay in function of time. Since the measurements of the impulse response are conducted in an urban environment, they are likely to be contaminated with noise. This results in a lower signal-to-noise ratio and thus limits the decay of the sound produced by the loudspeaker (and levelfunction) in the street. Choosing an appropriate test signal such as an exponential sweep, high emission levels and repetitions can partly counter this. Other techniques to lower the influence of the background noise include subtraction of a mean squared average of the noise from the band filtered response and truncation of the impulse response, of which the truncation point is determined as the The measurements of the impulse response and related parameters are valid only if the influence of the car and set-up on the results can be ignored. Therefore, reference measurements are conducted in an open rural area with no reflecting boundaries, except for the soil. Five successive measurement cycles are conducted and the reverberation time is analyzed, which should be significantly lower than the reverberation measured in the streets. Fig. depicts the resulting mean reverberation time EDT and T 3. These results are calculated from an average of five measurement cycles. A comparison is made between results from the microphone at the back and front. As can be noted from fig. (a), the EDT is lower than.7 s at octave bands higher than the 63 Hz octave band. The standard deviation from the mean value is negligible and the results from both the back and front microphone are alike. However, for the 63 Hz octave band, the deviation and difference between microphones is higher. Investigation of the used loudspeaker learns that these frequencies are not accurately reproduced. This octave band will thus be omitted. For the T 3 (fig. (b)), somewhat higher values are found. However, when comparing to street measurements, these are still sufficiently limited. The highest value (at the 5 Hz octave band) is near 6 s. The standard deviation is larger than for the EDT, but still acceptable. Some difference in T 3 between front and back can be observed, but the difference between both microphone positions is limited (Δ max.9 s at 5 Hz). In general the influence of the car and measurement set-up on the resulting reverberation time is negligible compared to reverberation times measured in most street configurations. However, more open streets, with gaps between buildings, could have very low reverberation. Care should be taken to interpret such results, so a selection procedure will be built in to detect reverberation measurements which are not significantly different from the reference measurements. 3. Urban street reverberation measurements In order to produce a reverberation map of a city and investigate whether the reverberation can be correlated to architectural and geometrical parameters, the reverberation is measured at 77 points in Ghent, Belgium. Streets of various, building height, length

FORUM ACUSTICUM 7. June -. July, Aalborg.9 front back.9 front back.7.7 EDT (s).5 T3 (s).5.3..3.5.6.6.5.6.4.3..3.3....... 63 Hz 5 Hz 5 Hz 5 Hz khz khz 4 khz 8 khz 6 khz octave band (a) EDT.3..3 6.6 4..8.5.5.6.3.3.5.3.. 63 Hz 5 Hz 5 Hz 5 Hz khz khz 4 khz 8 khz 6 khz octave band (b) T3 Figure. Measurement of the mean EDT and T 3 for the reference situation, based on five measurement cycles. In blue the results when using the front microphone, in red the results for the microphone at the back. The standard deviation from the mean value is also indicated. Figure 3. Geographical map indicating the different locations (77) measured in the city of Ghent. The marker at the left indicates the reference measurement position. The colors indicate different measurement dates. and architectural styles were selected and for each of the locations, the reverberation EDT and T 3 is measured. Fig. 3 shows a map of Ghent with the different measurement positions and also the location of the reference measurement position. Fig. 4 resp. fig. 5 shows a reverberation map of the EDT resp. T 3. A difference is observed in the course of EDT and T 3. For the EDT a lower value is measured in the city outskirts. Streets in these areas are typically wider and detached housing is more common. In the city-center, the reverberation increases. T 3 is a less sensitive parameter than EDT, as little differences are observed between measurements at center areas and outskirts. These maps however only depict the reverberation at discrete measurement points within streets.

FORUM ACUSTICUM 7. June -. July, Aalborg.7 -. s.7 -. s. - s. - s -.3 s -.3 s.3 - s.3 - s -.5 s -.5 s.5 - s.5 - s -.7 s -.7 s (a) EDT at 5 Hz octave band. (b) EDT at khz octave band. Figure 4. Reverberation map of Ghent for EDT, measured at the 5 Hz and khz octave band. -.75 s -.75 s.75 -.9 s.75 -.9 s.9 -.5 s.9 -.5 s.5 -. s.5 -. s. -.35 s. -.35 s.35 -.5 s.35 -.5 s.5 -.65 s.5 -.65 s (a) T 3 at 5 Hz octave band. (b) T 3 at khz octave band. Figure 5. Reverberation map of Ghent for T 3, measured at the 5 Hz and khz octave bands. 3.. Correlation analysis Rather then measuring the reverberation at a huge number of discrete locations, a time consuming work, it can be investigated to what extent the reverberation time could be calculated in function of the geometrical and architectural parameters. If this would be the case, a reverberation map with higher resolution could be created, based on simple parameters. Therefore, the reverberation time is plotted in function of street, height, length and height- ratio. In fig. 6 the correlation between EDT and the resp. height- ratio is shown for the 5 Hz and khz

FORUM ACUSTICUM 7. June -. July, Aalborg.9 y =.5x +.376 R =.574 p <..9 y =.x +.579 R =.77 p <..7.7 EDT (s) @ 5 Hz.5 EDT (s) @ khz.5.3.3.. 5 5 5 (a) Influence of at 5 Hz octave band. 5 5 5 (b) Influence of at khz octave band..9 y =.58x +.8 R = 7 p <..9 y = 5x +. R = 63 p <..7.7 EDT (s) @ 5 Hz.5 EDT (s) @ khz.5.3.3...5.5 height ratio (c) Influence of height- ratio at 5 Hz octave band..5.5 height ratio (d) Influence of height- ratio at khz octave band. Figure 6. Correlation analysis of EDT at the 5 Hz and khz octave bands in function of and height- ratio. The fitted line is indicated, as well as the correlation coefficient and significance. The color scale indicates the amount of facade roughness, with yellow meaning many irregularities and red meaning little. octave band. It is seen that EDT correlates negatively with the. As the street increases, energy is less contained in the street, so the EDT decreases. The EDT correlates positively with the height- ratio. The higher this ratio, the more the street can be seen as a street canyon, the more the sound energy remains in the street. These correlations become higher as the frequency rises. The measurements show that EDT is not correlated with the length of the street (not depicted). In fig. 7 the correlation between T 3 and the resp. height- ratio is given. The figures show a small positive correlation with and a small negative correlation with height- ratio. This correlation is however very small and furthermore not significant in most cases (p >.5). This is the case for all octave bands. In both figures the color of the points indicates the amount of facade roughness, with yellow meaning many facade irregularities and ornaments and red meaning only little. Quantification of the level of irregularities was based on visual evaluation of the facades. At first sight, no obvious correlation is seen between the amount of roughness and both EDT and T 3. However, further research should be conducted to incorporate a more thoroughly evaluation of the architectural details. 4. Conclusion In this paper a new method is designed to measure the reverberation time and other impulse response related parameters in a fast and mobile way. By putting the measurement equipment on the roof of a car, street

FORUM ACUSTICUM 7. June -. July, Aalborg.8 y =.6x + 9 R = 84 p <.5.8 y =.5x +.5 R = p >..6.6.4.4 T3 (s) @ 5 Hz. T3 (s) @ khz. 5 5 5 (a) Influence of at 5 Hz octave band. 5 5 5 (b) Influence of at khz octave band..8 y =.54x +. R = 6 p >..8 y =.3x +.3 R =.66 p >..6.6.4.4 T3 (s) @ 5 Hz. T3 (s) @ khz..5.5 height ratio (c) Influence of height- ratio at 5 Hz octave band..5.5 height ratio (d) Influence of height- ratio at khz octave band. Figure 7. Correlation analysis of T 3 at the 5 Hz and khz octave bands in function of and height- ratio. The fitted line is indicated, as well as the correlation coefficient and significance. The color scale indicates the amount of facade roughness, with yellow meaning many irregularities and red meaning little. reverberation measurements have been conducted in 77 streets in the city of Ghent, Belgium. The resulting EDT and T 3 is analyzed in octave bands and plotted on a map to identify regions with low or high reverberation. In districts further from the city-center the reverberation time (EDT) is typically lower due to more openness of the streets. In an attempt to predict the reverberation in the city, a correlation analysis is conducted. It is found that the EDT correlates highly with the street and height- ratio. However no significant correlation between the geometrical parameters and T 3 can be found. In following work other acoustical parameters such as center time T s will be investigated and further research for the influence of facade geometry will be included. References [] D. Ouis: Annoyance from road traffic noise: a review. J. of Env. Psych. () -. [] B. Griefahn, A. Marks, S. Robens: Noise emitted from road, rail and air traffic and their effects on sleep. J. Sound Vib. 95 (6) 9-4. [3] L. Barregard, E. Bonde and E. Öhrström: Risk of hypertension from exposure to road traffic noise in a population-based sample. Occup. Environ. Med. 66 (9) 4-45. [4] D. Paini, A. Gade, J. Rindel: Is reverberation time adequate for testing the acoustical quality of unroofed auditoriums? Proc IoA 8 (6) 66-73 [5] Acoustics - measurement of room acoustic parameters - part : performance spaces. ISO 338-:9(E) (9) [6] A. Lundeby, T. Vigran, H. Bietz, M. Vorländer: Uncertainties of measurements in room acoustics. Acustica 8 (995) 344-355.