PCB Relay G5Q Compact, High Isolation Relay D Compact single pole relay with high isolation between coil and contacts. D Up to 10 A switching on the NO contacts. D Ensures a withstand impulse voltage of 8,000 V between the coil and contacts. D Low coil power consumption. D UL class F coil insulation. D UL, CSA, and VDE approvals. D Ideal for appliance and HVAC controls. D RoHS Compliant. Ordering Information To Order: Select the part number and add the desired coil voltage rating, (e.g., G5Q-14-DC12) Classification Enclosure rating Model Single contact, class F coil SPST-NO Vented G5Q-1A insulation i Sealed G5Q-1A4 SPDT Vented G5Q-1 Sealed G5Q-14 Specifications J COIL RATINGS Rated voltage (V) Rated coil Coil current (ma) resistance sta (Ω) Pick-up voltage Drop-out voltage Percent of rated voltage Maximum voltage SPDT DC 5 80 63 75% max. 5% min. 190% @ 23 C 400 DC 12 33.3 360 DC 24 16.7 1440 SPST-NO DC 5 40 125 200 DC 12 16.7 720 DC 24 8.3 2880 Note: Rated current and coil resistance are measured at 23 C with a tolerance of ±10%. Power consumption o (mw) 638 PCB Relay G5Q
J CONTACT RATINGS Load SPDT SPST-NO Rated load (resistive) Contact material Rated carry current Max. switching voltage Max. switching current Max. switching capacity Min. permissible load 10 A @ 125 VAC (NO) 3 A @ 250 VAC (NO) 5A@30VDC(NO) 3 A @ 125 VAC (NC) 3 A @ 30 VDC (NC) Ag Alloy 10 A (NO)/3 A (NC) 277 VAC, 30 VDC AC: 10 A (NO)/3 A (NC) DC: 5 A (NC)/3 A (NC) 1250 VA, 150 W (NO) 375 VA, 90 W (NC) 10 ma at 5 VDC (P level: λ60=0.1 x 10 -- 6 operation) 10 A @ 125 VAC 3 A @ 250 VAC 5A@30VDC J CHARACTERISTICS Contact resistance (See Note 2.) Operate time Release time Insulation resistance (See Note 3.) Dielectric strength Impulse withstand voltage Vibration resistance 100 mω max. 10 ms max. 5 ms max. 1,000 MΩ min. 4,000 VAC, 50/60 Hz for 1 min between coil and contacts 1000 VAC, 50/60 Hz for 1 min between contacts of same polarity 8kV(1.2x50 µs) between coil and contacts Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours Malfunction: 10 to 55 Hz, 1.5-mm double amplitude for 5 minutes Shock resistance Destruction: 1,000 m/s 2 (approx. 100G) Malfunction: 100 m/s 2 (approximately 10G) Life expectancy (See Note 4.) Mechanical 10,000,000 operations (18,000 operations per hour) Ambient temperature Ambient humidity Electrical Switching frequency Operating & storage Operating & storage 200,000 operations: 3 A (NO)/3 A (NC) at 125-VAC resistive load 100,000 operations: 3 A (NO)/3 A (NC) at 250 VAC 5 A (NO)/3 A (NC) at 30-VDC resistive load 50,000 operations: 10 A (NO) at 125-VAC (900 operations per hour) 1,800 operations per hour --40 C to 105 C (--40 F to 221 F) with no freezing or condensation 5% to 85% Note: 1. The data shown above are initial values. 2. The contact resistance is possible with 1 A applied at 5 VDC using a fall-of-potential method. 3. The insulation resistance is possible between coil and contacts and between contacts of the same polarity at 500 VDC. 4. The electrical life data items shown are possible at 23 C. PCB Relay G5Q 639
J APPROVED STANDARDS UL508 (File No. E41515) CSA C22.2 No. 14 (File No. LR31928) Model Coil ratings Contact ratings (See Note) NO contacts G5Q 5--48 VDC 10 A, 250 VAC resistive 10 A, 30 VDC resistive 4 A, 120 VAC resistive, 100,000 ops. 4 FLA, 4 LRA 120 VAC, definite purpose, 100,000 ops. 400W, 120 VAC, Tungsten, 25 C 5 LRA, 4 FLA, 120 VAC, definite purpose, 30,000 ops., 25 C NC contacts 3 A, 250 VAC resistive 3A,30VDCresistive 4 LRA, 2 FLA, 120 VAC definite purpose, 100,000 ops. 400W, 120 VAC, Tungsten, 25 C 5 LRA, 4 FLA, 120 VAC, definite purpose, 30,000 ops., 25 C Note: Ratings for both NO contacts and NC contacts are given at 105_C (221_F), unless specified. VDE (Reg. No. 125314) Model Coil ratings Contact ratings G5Q 5, 12, 24 VDC 10 A, 250 VAC cosφ=1 (NO) 5A,30VDCL/R=0ms(NO) 3A,30VDCL/R=0ms(NC) 640 PCB Relay G5Q
Engineering Data J AMBIENT TEMPERATURE VS. MAXIMUM VOLTAGE Maximum coil voltage (% of rated) 200 180 160 140 120 100 80 60 40 20 0 -- 40 J AMBIENT TEMPERATURE VS. RATED CARRY CURRENT -- 20 0 20 40 60 80 100 Ambient temperature ( C) 105 120 0 20 40 60 80 100 105 120 Ambient temperature ( C) J MAX. SWITCHING CAPACITY Switching current (A) 12 11 10 9 8 7 6 5 4 3 2 1 0 1 DC resistive load (NO) DC resistive load (NC) AC resistive load (NC) AC resistive load (NO) 10 30 100 250 277 Switching voltage (V) 1000 Rated carry current (A) 12 11 10 9 8 7 6 5 4 3 2 1 0 NO contact NC contact PCB Relay G5Q 641
Dimensions Unit: mm (inch) J G5Q SPDT 20.3 max. (0.799) 10.3 max (0.406) PCB Mounting Holes Tolerance: ±0.1 mm Terminal Arrangement/ Internal Connections 3.4 (0.134) j0.4 1.0 (0.04) 15.8 max (0.622) 0.4 1.18 (0.046) 1.19 (0.047) 10.16 (0.400) 5.08 (0.20) 2.54 (0.10) Five, 1.3±0.1-dia. holes (No coil polarity) J SPST-NO 20.3 max. (0.799) 10.3 max (0.406) PCB Mounting Holes Tolerance: ±0.1 mm Terminal Arrangement/ Internal Connections 3.4 (0.134) j0.4 1.0 (0.04) 15.8 max (0.622) 0.4 1.18 (0.046) 1.19 (0.047) 10.16 (0.400) 1.08 (0.043) Four, 1.3±0.1-dia. holes (No coil polarity) Precautions For general precautions on PCB Relays, refer to the precautions provided in the Relay Catalog Reference Information Section. Document available on line.! Caution Do not touch the terminals of the Relay or the charted part of the socket when power is supplied to the Relay. Otherwise, an electric shock may occur. 642 PCB Relay G5Q
Certain Precautions on Specifications and Use 1. Suitability for Use. Seller shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in Buyer's application or use of the Product. At Buyer's request, Seller will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer's application, product or system. Buyer shall take application responsibility in all cases but the following is a nonexhaustive list of applications for which particular attention must be given: (i) Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this document. (ii) Energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. (iii)use in consumer products or any use in significant quantities. (iv)systems, machines and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to this product. NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. 2. Programmable Products. Seller shall not be responsible for the user's programming of a programmable product, or any consequence thereof. 3. Performance Data. Performance data given in this publication is provided as a guide for the user in determining suitability and does not constitute a warranty It may represent the result of Seller's test conditions, and the users must corre late it to actual application requirements. Actual performance is subject to Seller's Warranty and Limitations of Liability. 4. Change in Specifications. Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our prac tice to change part numbers when published ratings or features are changed or when significant construction changes are made. However, some specifica tions of the Product may be changed without any notice. When in doubt, spe cial part numbers may be assigned to fix or establish key specifications for you application. Please consult with your Seller representative at any time to con firm actual specifications of purchased Product. 5. Errors and Omissions. The information in this publication has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors, or omissions. 6. RoHS Compliance. Where indicated, our products currently comply, to the bes of our knowledge as of the date of this publication, with the requirements of the European Union's Directive on the Restriction of certain Hazardous Sub stances ("RoHS"), although the requirements of RoHS do not take effect unti July 2006. These requirements may be subject to change. Please consult ou website for current information. Complete Terms and Conditions of Sale for product purchase and use are on Omron s website at www.components.omron.com under the About Us tab, in the Legal Matters section. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. OMRON ELECTRONIC COMPONENTS LLC 55 E. Commerce Drive, Suite B Schaumburg, IL 60173 847-882-2288 Cat. No. JB301-E3-01 OMRON CANADA, INC. 885 Milner Avenue Toronto, Ontario M1B 5V8 416-286-6465 3/05 Specifications subject to change without notice OMRON ON-LINE Global - http://www.omron.com USA - http://www.components.omron.com Canada - http://www.omron.ca Printed in USA