VAC 60HZ A 120V; 0..18A 277V 40W PF ,000 LM 125 LM/W >82 <19. Arcata VDC 1.2A 120V 88% Edison

Similar documents
Test Report. Report No.: EED35I Page 1 of 10. Customer : EIKO GLOBAL LLC Address : W 84TH ST SHAWNEE, KS USA

1X4 LED Panel Light RoHS 0-10V Dimmable QPL ID #

CTI nm mg. Test Report. Report No.: EED35H l Page 1 of 15. EiKO Global, LLC W 84th St, Shawnee, KS

RoHS QPL ID # PLC6V1PABNUJS

RoHS. Dimming: PWM/VR/0-10V QPL ID # PL21D5Q1B95E. Cat# W FlatPanel Pole Mount. EPA Rating 2.33ft 2.

2X4 LED Panel Light RoHS 0-10V Dimmable QPL ID #

Cat# LED Classic Large Wall-Pack

RoHS QPL ID # P9JSE2P8. Cat# Watts Trunion Mount. Model: master carton: L*W*Hmm 1PCS. EPA Rating 1.

RoHS 0-10V Dimmable QPL ID # PXQGXDYK

RoHS QPL ID # PNZ72BAB

RoHS QPL ID # PNZ72BAB

Cat# 71426A LED Wall-PACK QPL ID # PLO3JLI4OV69

71345A. 50W LED Floodlight Yoke(Bracket) Mount. RoHS QPL ID # PLDUWHES4P5Q. Model: 71345A


RoHS VAC 50/60HZ 1.8A Max 150W PF LM 123 LM/W x 90 Aluminium + PC Lens 36-60VDC 4.4A 88% Philips 3030 LED 36 PCS

RoHS VAC 50/60HZ 0.38A Max W PF LM LM/W x 90


Dimming: PWM/TIME/0-5V/0-10V. RoHS

RoHS. Model: VAC 50/60HZ 0.127A Max 14.6 W PF LM LM/W x90 Aluminium Housing + Polycarbonate Lens

71352A QPL ID # PLT2P2L2UNWR. RoHS

Cat# 71146A 150W Trunion Mount

RoHS. Model: VAC 50/60HZ.83A Max 100W

Cat# 71440A LED Classic Large Wall-Pack

Direct to wall VAC / 30W PF ,290 LM 110 LM/W B2-U0-G1. Alluminium + Tempered Glass 24-48VDC 0.

Cat# LED High Bay

Cat# LED Classic MINI Wall-PACK

LED Floodlight. RoHS. Model: inner box: L 17" X W 12.5" X H 9.33" 1PCS AC 50/60HZ. Input Voltage 0.85A MAX. Input Current 78 W.

Cat# LED Wall-PACK

Catalog Number UPC Number LED Spot Bullet Flood Light 15W 1620 Lumens Bronze

Catalog Number UPC Number LED Spot Bullet Flood Light 42W 4204 Lumens White

Morris Products 53 Carey Road, Queensbury, NY 12804

Report No.: EASZE Page 2 of 14

LM Test Report. for EiKO Global, LLC. 25W Floodlight Model: FLM-2C-N-U

71332 LED Dusk To Dawn (Area Light)

LM Test Report. for Maxlite Inc. LED Canopy Model: MLCAN20LED50

LM Test Report. for Maxlite SK America Inc. WALLPACK Model: MLSWP30LED50DS

Morris Products 53 Carey Road, Queensbury, NY 12804

LM Test Report

LM Test Report. for Maxlite SK America Inc. 2*4 Retrofit Kits Model: RKT4514U5550DV

LM Test Report

Morris Products 53 Carey Road, Queensbury, NY 12804

QPL ID # PLG2YNJ831VZ

Dark Sky Wallpack 50W. General ACD12 Aluminum Heat Sink High Light Transmittance Polycarbonate, Anti-UV and Fire Resistant Finish:

LM Test Report. For. T8 LEDTUBE Model: LED9WT8 F/24/850K-G7D

Report No.: HZ b. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

LED DOWN LIGHT (Dimmable)

LM Test Report. for. Philips (China) Investment Co., Ltd. InstantFit LEDtube Model:

(Lumens) Stabilization Time CRI (K) (Light & Power) Table 1 Executive Data Summary

Report No.: HZ k/R1. (Lumens) Stabilization Time CRI (K) (Light & Power) Table 1: Executive Data Summary

LM Test. for LED. Cabinet

LM Test Report

Report No.: HZ c/R1. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

LM Test Report

LM Test Report

LED DOWN LIGHT Size : Φ196x76mm(7.72x2.99") Characteristics. Item Number Description. 5/6 LED Gimbal Down Light. CRI 90 Lumens.

Report No.: HZ b. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

LM Test Report. for Elec-Tech International Co.,Ltd. LED CEILING LIGHT Model: XX(XX: 01-10)

Report No.: HZ h/R1. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

LM Test Report. for Elec-Tech International Co.,Ltd. LED CEILING LIGHT Model: XX(XX: 61-70)

LM Test Report. for Elec-Tech International Co.,Ltd. LED CEILING LIGHT Model: XX(XX: 01-10)

NVLAP LAB CODE LM Test Report. For. MaxLite Inc. (Brand Name: MaxLite) 12 York Ave West Caldwell NJ 07006

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MAXLED) 12 York Avenue West Caldwell, NJ

Report No.: HZ a/R2. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

NVLAP LAB CODE LM Test Report. For. Maxlite Inc. (Brand Name: ) 12 York Avenue, West Caldwell, NJ

L Test Report. LED TUBE 1odel: LED11.5WT8/48/850-PET-G7DR

LM Test Report. For. GREEN LOGIC LED ELECTRICAL SUPPLY INC (Brand Name: GLLUSA) Shenfubao Industry Park, Bonded area, Futian District,Shenzhen

NVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING)

Report No.: HZ a/R2. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

(Lumens) Stabilization Time CRI (K) (Light & Power) Table 1 Executive Data Summary

Report No.: HZ h. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

LM Test Report. for Elec-Tech International Co.,Ltd. LED PAR30 Spot light Model: XX(XX:41-50)

Approved Method: Electrical and Photometric Measurements of Solid-State Lighting Products

LM Test Report. For KEYSTONE TECHNOLOGIES LLC. (Brand Name: KEYSTONE) 1390 Welsh Road North Wales, PA 19454

NVLAP LAB CODE LM Test Report. Outdoor Non-Cutoff and Semi-Cutoff Wall-mounted Area Luminaires. Model name(s): WML-50W

NVLAP LAB CODE LM Test Report. Outdoor Full-Cutoff Wall-mounted Area Luminaires. Model name(s): LWA-50W

LED DOWN LIGHT (Dimmable)

LM Test Report. For FALKOR INDUSTRY INC. (Brand Name: Falkor Lighting) 5580 Bandini Blvd Bell,CA USA

DRAFT. Approved Method: Electrical and Photometric. Measurements of Solid-State Lighting Products. LCTECH (Zhongshan) Testing Service Co.

NVLAP LAB CODE LM Test Report. Outdoor Non-Cutoff and Semi-Cutoff Wall-mounted Area Luminaires

LM Test Report. for Elec-Tech International Co., Ltd. BR40 LAMP Model: XX(XX:01-10), WBR40L27S2A

NVLAP LAB CODE LM Test Report. For. Maxlite INC. (Brand Name: Maxlite) 12 York Ave., West Caldwell, NJ 07006

LED DOWN LIGHT (Dimmable)

Approved Method: Electrical and Photometric. Measurements of Solid-State Lighting Products

NVLAP LAB CODE LM Test Report. For MAXLITE,INC. (Brand Name: N/A) 12 YORK AVENUE WEST CALDWELL,NJ 07006

Photometric Test Report

NVLAP LAB CODE LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name: N/A) 188 S. Northwest Highway Cary, IL 60013

NVLAP LAB CODE LM Test Report. For ATG ELECTRONICS CORP. (Brand Name: N/A) th Street Rancho Cucamonga, CA 91730

Report No.: HZ f. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

NVLAP LAB CODE LM Test Report. For HOCAN GROUP CO LTD. (Brand Name: N/A)

NVLAP LAB CODE LM Test Report For. Outdoor Pole/Arm-mounted Area and Roadway Luminaires

NVLAP LAB CODE LM Test Report. For GREEN LOGIC LED ELECTRICAL SUPPLY INC. Outdoor Full-Cutoff Wall-mounted Area Luminaire

NVLAP LAB CODE LM Test Report. For HOCAN GROUP CO LTD. (Brand Name: N/A)

NVLAP LAB CODE LM Test Report. For HOCAN GROUP CO LTD. (Brand Name: N/A)

LM Test Report. For FALKOR INDUSTRY INC. (Brand Name: Falkor Lighting) 5580 Bandini Blvd Bell,CA USA

Address: IES LM Luminaire Description: Indoor High Bay Light Source: LGIT 5630 Ballast/Driver: VPL Overdrive L320HBL46DIM/50K

NVLAP LAB CODE LM Test Report. For BEYOND LED TECHNOLOGY Mountain Industrial Blvd. Suite A-1 Tucker, GA USA

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD. (Brand Name: THAILIGHT)

NVLAP LAB CODE LM Test Report. For. LED2 Lighting Group, Inc. (Brand Name: LED2) 600 Minnesota Ave, Kansas City, KS 66101

NVLAP LAB CODE LM Test Report. For. LED2 Lighting Group, Inc. (Brand Name: LED2) 600 Minnesota Ave, Kansas City, KS 66101

NVLAP LAB CODE LM Test Report. For EIKO GLOBAL, LLC W 84th St., Shawnee, KS

Transcription:

71781 2X2 LED Troffer RoHS 0-10V Dimmable QPL ID # PR3BFQPW Model: 71781 Input Voltage 120-277 VAC 60HZ Input Current.3339A Max @ 120V; 0..18A Max @ 277V Input Power 40W Power Factor PF 0.99 Luminance 5,000 LM OVERALL LAMP PARAMETERS Luminous Efficiency 125 LM/W CRI >82 R9 9 Beam Angle 112 SDCM <7 UGR <19 Brand Arcata 2835 Output Voltage 12-24 VDC LED DRIVER Output Current 1.2A THD 12% @ 120V Driver Efficiency 88% LED Manufacturer Edison LED Type 2835 SMD LED LED Quantity LED Efficacy 238 PCS 140 LM/W Color Temperature 4000K Output Current 50mA Max; 37.5mA Applied Lifespan 50,000+ Hrs. Warranty 5 Years LIFESPAN & ENVIRONMENT IP Rating IP21 Dry Locations Operating Temperature -20 +40 Storage Temperature.Humidity -40 +80, 10 90% RH Safety Norms UL1598,UL8750, EN60598, EN61347-2-13, EN62031, EN62471 SAFETY&EMC Withstand Voltage Grounding Resistance I/P-FG: 2121VDC 25A 100mΩ Electromagnetic Compatibility EN55015, EN61000-2-3, EN61000-3-3, EN61547 Dimension Pls refer to attached dimension drawing Net Weight 0.6KG OTHERS Gross Weight Q'ty / Carton 纸箱 Volume Housing Color Main Structure 0.8KG 2 PCS 0.52Cbm/carton White Aluminium Frame + Polystyrene Lens www.morrisproducts.com

Report No.:EED35I000625-2 Page 1 of 9 Customer Address : Morris Products Inc. : 53 Carey Rd. Queensbury, NY 12804 Description of the submitted sample(s): Sample Name : LED Luminaire Model/Type : 71780 Brand : MORRIS Sample No. : 35I0625-02 Ratings : 120-277 V AC, 50/60 Hz, 40 W, 5000 K Test Item : Total Luminous Flux, Luminous Efficacy, Zonal Lumen Density, Luminous Intensity Distribution, Correlated Color Temperature, Color Rendering index, State of Sample(s) Sample Quantity Manufacturer Chromaticity Coordinate and Electrical Parameters : Normal : 1 pc : Morris Products Inc. Sample Received Date : Nov. 09, 2016 Sample Tested Date : Nov. 09, 2016 to Nov. 10, 2016 Test Requested : All test items were measured according to IES LM-79-08 Approved Method for the Electrical and Photometric Measurements of Solid-State Lighting Products Laboratory Note: The laboratory that conducted the testing items in this report has been accredited by the National Voluntary Laboratory Accreditation Program (NVLAP LAB CODE: 200889-0), for IES LM-79 testing of SSL products. And the report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. Compiled by Reviewed by Approved by Date Dec. 22, 2016 Engineer/Heven Liu Check No.: 2457570188 CENTRE TESTING INTERNATIONAL CORPORATION NO.1996, Xin jin qiao Road, Pudong New District, Shanghai, 201206, China

Report No.:EED35I000625-2 Page 2 of 9 Equipment list: Test Equipment Equipment Model Equipment No. Calibration Date Calibration Due Date Goniophotometer GO-R5000 ATTEELSH00105 --- --- Standard Lamp D908 ATTEELSH00106 Jul. 06, 2016 Jul. 05, 2017 Digital Power Meter WT210 BTTEELSZ10093 Jun. 17, 2016 Jun. 16, 2017 Spectroradiometer HAAS-2000 TTF20120376 --- --- Integrating Sphere 2.0m ATTEELSH00007 --- --- Standard Lamp D204 TTE20141711 Jul. 06, 2016 Jul. 05, 2017 Digital Power Meter PF2010 ATTEELSH00011 Jun. 17, 2016 Jun. 16, 2017 1 Test Condition Ambient Condition : 25.1 Photometric Method Colorimetric Method Tested Stabilization Time Total Operation Time including Stabilization : Goniophotometer : Sphere-spectroradiometer : 120 V AC, 60 Hz : 60 minutes : 95 minutes 2 Test Method 2.1 Requirements of Ambient Condition The ambient temperature in which measurements are being taken shall be maintained at 25 ± 1, measured at a point not more than 1 m from the SSL product and at the same height as the SSL product. Air flow around the SSL product being tested should be such that normal convective air flow induced by device under test is not affected. 2.2 Seasoning of SSL Product For the purpose of rating new SSL products, SSL products shall be tested with no seasoning. Therefore, no seasoning was performed.

Report No.:EED35I000625-2 Page 3 of 9 2.3 Stabilization of SSL Product Before measurements are taken, the SSL product under test shall be operated long enough to reach stabilization and temperature equilibrium. The time required for stabilization depends on the type of SSL products under test. The stabilization time typically ranges from 30 minutes to 2 or more hours for SSL product. It can be judged that stability is reached when the variation (maximum minimum) of at least 3 readings of the light output and electrical power over a period of 30 minutes, taken 15 minutes apart, is less than 0.5%. 2.4 Photometric and Electrical Measurements Sphere-spectroradiometer Method A spectroradiometer and an integrating sphere were used to measure correlated color temperature, color rendering index, and chromaticity coordinates. The 4 geometry, shown as following, chart (a), is used for measurement. Ambient temperature was measured at a position inside the integrating sphere. Electrical measurements including voltage, current, and power were measured using the digital power meter. The calibration of the sphere-spectroradiometer system is traceable to the National Institute of Standards and Technology. 2.5 Photometric and Electrical Measurements - Goniophotometer Method A type C goniophotometer was used to measure total luminous flux and intensity at each angle of distribution. The photometric distance is 2.1m for near-field measurement or 26m for far-field measurement. Ambient temperature was measured at the same height of the sample mounted on the goniophotometer equipment. Electrical measurements including voltage, current, and power were measured using the digital power meter. Some graphics were created with Photometric Plus software. (a)

Report No.:EED35I000625-2 Page 4 of 9 3 Test Results 3.1 Photometric and Electrical Measurements Input Voltage (V AC) Input Current (A) Input Power (W) Power Factor THD of Current (%) 120.0 0.3339 39.69 0.9908 12.11 Total Luminous Flux (lm) Luminous Efficacy (lm/w) Correlated Color Temperature (K) Color Rendering Index/R a Color Rendering Index/R 9 4899.1 123.43 4996 82.3 9 Chromaticity Chromaticity Chromaticity Chromaticity Coordinate Coordinate Coordinate Coordinate Duv x y u' v 0.3457 0.3576 0.2095 0.4877 0.0027 Note: According to CIE 1976 (u', v') diagram, u' = u = 4x/(-2x+12y+3), v' = 3v/2 = 9y/(-2x+12y+3).

Report No.:EED35I000625-2 Page 5 of 9 3.2 Zonal Lumen Density

Report No.:EED35I000625-2 Page 6 of 9 3.3 Luminous Intensity Distribution

Report No.:EED35I000625-2 Page 7 of 9 3.4 Luminous Intensity Distribution Data

Report No.:EED35I000625-2 Page 8 of 9

Report No.:EED35I000625-2 Page 9 of 9 Photos of the Sample Fig.1- Overall view Fig.2- Back view *** End of Report *** This test report is effective only with both signature and specialized stamp. The result(s) shown in this report refer only to the sample(s) tested. Without written approval of CTI, this report can t be reproduced except in full.