IPA FITTINGS FOR REHAU NORDIC

Similar documents
IPA FITTINGS FOR REHAU NORDIC DESIGN A/S J. PETERSENS BESLAGFABRIK JACOB PETERSENSVEJ 9, DK-9240 NIBE TEL: (+45)

IPA FITTINGS FOR VEKA DANLINE 70 A/S J. PETERSENS BESLAGFABRIK JACOB PETERSENSVEJ 9, DK-9240 NIBE TEL: (+45)

IPA FITTINGS FOR ALUPLAST NORD-LINE A/S J. PETERSENS BESLAGFABRIK JACOB PETERSENSVEJ 9, DK-9240 NIBE TEL: (+45)

IPA FITTINGS FOR SCHÜCO ALU INSIDE NORDIC A/S J. PETERSENS BESLAGFABRIK JACOB PETERSENSVEJ 9, DK-9240 NIBE TEL: (+45)

IPA BESLAG FOR SCHÜCO ALU INSIDE NORDIC A/S J. PETERSENS BESLAGFABRIK JACOB PETERSENSVEJ 9, DK-9240 NIBE TEL: (+45)

NORTH STAR 2-PANEL PATIO DOOR ASSEMBLY INSTRUCTIONS

NORTH STAR 4-PANEL PATIO DOOR ASSEMBLY INSTRUCTIONS

Canopy Bed Frame. Date: 8 Jun 15 www. potterybarn.com Page 1 of 12 Rev:

TUR DOORS SHOWER DOORS

FOR DEVICES SOLD PRIOR TO

ASSEMBLY INSTRUCTIONS

* * 33/3549A CS 33/3549A. 2-Point Latch includes these additional parts. 1-Point Latch (LBL) Customer Service. Installation Instructions

UPTOWN CANOPY FRAME T/F/Q

Fitting & User Instructions

Tubing Spacers. Backing Plate. a a. a a. a a. a a. a a. a a. a a. a a. a a. a a. a a. a a. a a. a a. a a. a a. a a a. a a. a a

ET 51 EXTERIOR ROOF DRIP SIDE FINISH MOULDING INSTALLATION

Packing List MODEL TEL-IAL-481 For Inactive Leaf TRIDENT double door

Multi-Point Astragal Prehanger Installation Instructions

ASSEMBLY INSTRUCTIONS 5PC Storage Dining Set

Assembly instructions. 6x4. Model GH1354A. 6x6. Model GH1357A. 6x8. Model GH1360A. 6x10. Walk-in Greenhouse. Model GH1363A

TECHNOLOGY IN MOTION MACO TILT AND TURN FITTINGS. MULTI POWER fully concealed fittings INSTALLATION INSTRUCTIONS

Please Do Not Return Product to Store!

MATKI ONE MOWP - WETROOM PANEL & BRACE BAR MOWV - WETROOM PANEL & CEILING BAR

Weatherfold 4s 50, 75 & 100

670 Freestyle/Style Door with In-Line Panel

Nervous Nelly Vinyl Gate REALLY. Important stuff to know about installing your WamBam gate

Roller chains. Roller chains

Frami transport hook Art. n models onward

RETRACTABLE SCREEN ASSEMBLY AND INSTALLATION INSTRUCTIONS. SINGLE OUTSWING (Retro) / (Full-Size) STEP 1: REVIEW & CHECK FIG.

463-GP. Swing Door. Technical Assistance is available Monday - Friday, 8:00 a.m. - 5:00 p.m. (Central Time) (Toll Free) 463-GP 5/06

PARAGON BATH SHOWER DOOR/ BATH TUB SCREEN INSTALLATION INSTRUCTIONS. DR-584b

* * 98/9949 CS 98/ Point Latch includes these additional parts. 1-Point Latch (LBL) Customer Service. Installation Instructions

Weatherfold 4s 50 & 100 Brio Australia P: W: brio.com.au

blu The most efficient solution for manufacturing a flush casement window whilst maintaining the traditional image along with modern performance

Series Door with In-Line Panel (GIH / AHD)

Ultimate Trilennium Astragal Prehanger Installation Instructions

ELEGANCE SHOWER DOOR/ENCLOSURE INSTALLATION INSTRUCTIONS. Style A Style B Style C Style D

MODEL 351 POWERGLIDE SERIES INSTRUCTIONS FOR INSTALLING SARGENT DOOR CLOSERS WITH "H" HOLDER ARMS

W6 series greenhouse

Plain Jane Vinyl Gate REALLY. Important stuff to know about installing your WamBam gate

LEXUS IS250/IS350 FRONT SPOILER Section I - Installation Preparation. Part Number: Section I - Installation Preparation.

General Instructions 03HEL1010DDFW-V3. Please retain product label and instructions for future reference. 10x10 Helios Summer House

WETROOM WALK-IN AWL1500 AWL1200 AWL900 AWC850

PB-735 HD DP. Industrial Line. Automatic punch and bind machine for books and calendars

C. Side Panel 1 pc. B. Side Panel. 1 pc. J2. Shelf. 4 pcs. Adjustable Pin 24 pcs. (+1 extra) M3.5x16 Wood Screw 20 pcs. (+1 extra) 2 pcs.

TP Series - Triple PV Top of Pole Solar LED Lighting System

Steady Freddy Vinyl Gate REALLY. Important stuff to know about installing your WamBam gate

Incremental encoders Solid shaft with clamping or synchro flange pulses per revolution

846-GP. Neo-Angle Enclosure. Technical Assistance is available Monday - Friday 8:00 a.m. - 5:00 p.m. (Central Time) GP 12/05

Assembly instructions

PRIME SHOWER ENCLOSURE INSTALLATION INSTRUCTIONS

DRAWING TABLE SYSTEM

EAUZONE PLUS EPH - HINGED DOOR WITH HINGE PANEL FOR RECESS

CORNERVIEW / FRENCH CORNER

How To Measure Your Finished Opening

Exercise 1-1. The Sine Wave EXERCISE OBJECTIVE DISCUSSION OUTLINE. Relationship between a rotating phasor and a sine wave DISCUSSION

PREASSEMBLED ELEMENTS FOR LIFTING AND SLIDING DOORS

Ambient Light Rejecting Fixed Frame Screen. (3.9 width frame) User s Guide

Kitchen Island IMPORTANT Carefully remove all the parts from the carton and place them individually on a soft cloth to prevent scratches o

001CK CK0012 FR-001CK0013 FR EN English

620 Freestyle/Style Swing Door

DICTATOR RTS Tube Door Closer

GENERAL NOTES 1600 SYSTEM NOTES STRUCTURAL SEAL NOTES 1 - HANDLING, STORING AND PROTECTING ALUMINUM MATERIAL. 2 - GENERAL RULES

MIRAGE-X / BELLA. Shower Door Installation Instructions

DOOR BiFOLD DOOR SET (3 + 1)

B. Side Panel. E. Middle Panel 1 pc. 1 pc. 1 pc. S. Side Rack. 1 pc. T. Base Rack. U. Pipe 3 pcs. M6x35 Head Cap Bolt 14 pcs.

First Round Solutions Grades 4, 5, and 6

RETRACTABLE SCREEN ASSEMBLY AND INSTALLATION INSTRUCTIONS. DOUBLE INSWING (Retro) / (Full-Size) FIG. 1A STEP 1: REVIEW & CHECK FIG.

1200 SERIES 2 PANEL DOOR rev.1 DETAILED INSTALLATION INTRUCTIONS

Closet Wall Drawer Unit

FLEX ENCLOSURE SHOWER ENCLOSURE INSTALLATION INSTRUCTIONS

AQUA ULTRA SHOWER DOOR & TUB DOOR INSTALLATION INSTRUCTIONS

DRAWER BASE DRAWING TABLE

Section 1 Cubicles. Section 2 IPS Duct Panel Systems. Section 3 - Vanity Units Components & Assembly 12. Section 4 Basic Maintenance.

INFINITY-Z SHOWER DOOR / TUB DOOR INSTALLATION INSTRUCTION. MODEL #s 01-Chrome

Products no longer available

Installation & User Manual

UNIDOOR X (STYLE L1)

Aquauno Select MINUTES. (duration) FREQUENCY LED. OFF 8h AQUAUNO SELECT 5 MIN FREQUENCY. the timer is being programmed;

Brio. Weatherfold 5c 80. Codes B WC 4-80 S H SS. Sets all sets shown with hinge type H except BW2L/R-80SR. No finishes shown. Brio Weatherfold 5c

Seven Sisters. Visit for video tutorials

MULTI MAMMUT Heavy-duty hardware

INSTALLATION & OPERATION INSTRUCTIONS LEVER HANDLE LOCKSETS.

Brio. Weatherfold 5c 80. Codes B WC 4-80 S H SS. Sets all sets shown with hinge type H except BW2L/R-80SR. No finishes shown. Brio Weatherfold 5c

ESSENCE. Shower / Tub Door Installaion Instructions

PRISM LUX / PYRAMID SHOWER ENCLOSURE INSTALLATION INSTRUCTIONS

UNIDOOR (STYLE B & C)

FLEX 28 / 32 / 42 x 72

ARK CHEVRON INSTALLATION GUIDE

N. 15th Street, Middlesboro, KY FLIP TARP DUMP BODY INSTALLATION INSTRUCTIONS

QUATRA LUX SHOWER ENCLOSURE INSTALLATION INSTRUCTIONS

4 BAY Low Profile - SINGLE XL DISPLAY WALL MOUNT CABINET

CANOPY SYSTEMS PAGE 1 OF 14

CAVALIER. Shower Door Installation Instructions

MSRS90. Hi efficiency Notched and No-hand insert for MSRS90

J. Shelf 4 pcs. L. Door. K. Door. 1 pc. Magnet. 2 pcs. Adjustable Pin. 16 pcs. (+1 extra)

INSTALLATION MANUAL. English Edition D75X ULTRA SHORT SERIES

Drywall Lift Storage & Transportation Cart Model 110 Patents Pending

ESSENCE - H SHOWER / TUB DOOR INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Transcription:

IP FITTINGS FOR REHU NORDIC DESIGN PLUS 2017 /S J. PETERSENS BESLGFBRIK JCOB PETERSENSVEJ 9, DK-9240 NIBE TEL: (+45) 98 35 15 00

3 FITTINGS FOR REHU NORDIC DESIGN PLUS Table of contents PGE REHU Nordic Design Plus profile 4 Suggestion - Number of Hinges 6 Suggestion - Hinge Positions 7 FITTINGS IP No. 61874 Window hinge 8 IP No. 61808 Doorhinge for top mounting 9 IP No. 60896 djustable Door hinge 9-10 IP No. 60821 Threated Plate 9-10 IP No. 62896-97 Side swing window - adjustable 11-12 IP No. 62844-52 Top swing fi tting 13-15 IP No. 62862 Safety Restrictor 13-15 IP No. 62886-87 + 89 djustable Canopy Stay 17-18 IP No. 62888 djustable Canopy Stay - djustable Friction 19-20 IP No. 62836 Safety Restrictor 21-22 IP No. 62827 Friction Stay for Windows 23 IP No. 63811 Friction Stay for Doors 24 IP No. 62822 Support Fitting 25 IP No. 63830 Guide Block 25 IP No. 21371 Casement Hook 26-27 IP No. 21379 Casement Hook 26-27 IP No. 21382 Hook Catch 26-27 IP No. 21396 Casement Fasteners 26-27 Lubrication Instructions 28-29 17/05

4 REHU NORDIC DESIGN PLUS PROFILE FITTING INSTRUCTIONS 16.5 12.4 23 4.5 2.2 11.8

5 REHU NORDIC DESIGN PLUS PROFILE IP HS IN COOPERTION WITH REHU DEVELOPED SERIES OF FITTINGS FOR THE REHU NORDIC DESIGN PLUS PROFILE.

6 FITTING SUGGESTION INSTRUCTIONS - NUMBER OF HINGES The charts below show the number of hinges, we suggest to use on different sizes of windows and doors. The charts shall ONLY be considered as a guidance, as the number of hinges also will depend on the use and weight of the window/door. If the window/door is mounted in a public building with many users (Schools, Railway Stations etc.) then more or even larger hinges are recommended. lso we suggest to use a support fi tting whenever possible. WINDOW HINGES: Valid for the window hinges shown in this catalogue. ll window hinges meets the requirements of class 9 (60 Kgs.) in accordance with DS/EN 1935. The numbers in brackets are number of hinges in windows with 3-layer glass. Width Height < 500 501-600 601-700 701-800 1401-1500 2 (3) 3 (3) 3 (3) 3 (4) 1301-1400 2 (3) 3 (3) 3 (3) 3 (4) 1201-1300 2 (3) 3 (3) 3 (3) 3 (4) 1101-1200 2 (3) 3 (3) 3 (3) 3 (4) 1001-1100 2 (3) 3 (3) 3 (3) 3 (3) 901-1000 2 (2) 2 (2) 2 (2) 3 (3) 801-900 2 (2) 2 (2) 2 (2) 3 (3) 701-800 2 (2) 2 (2) 2 (2) 3 (3) 601-700 2 (2) 2 (2) 2 (2) 501-600 2 (2) 2 (2) < 500 2 (2) DOORHINGES: Valid for door hinges shown in this catalogue. ll door hinges with steel pin meets the requirements of class 13 (120 Kgs.) in accordance with DS/EN 1935. The same hinges with brass pin meets the requirements of class 11 (80 Kgs.) in accordance with DS/EN 1935 Width Height < 700 701-800 801-900 901-1000 1001-1100 2501-2600 5 5 5 2401-2500 5 5 5 5 2301-2400 4 4 4 5 5 2201-2300 4 4 4 4 5 2101-2200 3 3 3 4 4 2001-2100 3 3 3 3 4 < 2000 3 3 3 3 4

7 SUGGESTION - HINGE POSITIONS 90 130 130 180 250 250 90 400 250 130 400 130 TTENTION: The suggested placement of the hinges is ONLY a recommendation. When mounting Window - or Door elements in buildings the fastening points of the Frame should be by the hinges, supporting the Frame as best as possible in the areas where the load from the sash/door is transferred to the Frame. 225 18.08

4.5 8 WINDOW HINGE IP NO. 61874 C ORDERING NO. MTERIL SURFCE IP NO. STEEL FIXED STEEL PIN SQURE EDGES LEFT SQURE EDGES RIGHT ELECTROPL. + GREY IP NO. 61874 FITTING INSTRUCTIONS REHU NORDIC DESIGN PLUS: 11.8 ELECTROPL. + WHITE 2.2 GLVNIZED INDUSTRY PCKING IN BOXES OF 100 PCS. MM B MM C MM MTERIL MM PIN MM SCREW PPROX. WEIGHT KGS / PIECES 61874 2 3 4 64 66 87 2 90 38 37 2,5 8 4,0 0,19 B FIG. 1 FIG. 2 12.4 16.5 USE SCREW NO. 4.0. MINTENNCE: TEST THE OPERTION FROM TIME TO TIME. WHEN FITTING - GRESE THE PIVOT/MOVBLE METL PRTS OF THE MECHNISM WHILE CTIVTING REPETEDLY. HEREFTER GRESE MINIMUM TWICE YER. SEE LSO INSTRUCTIONS ON PGE 28-29.

9 DJUSTBLE DOOR HINGE IP NO. 60896, IP NO. 60821 & IP NO. 61808 C ORDERING NO. MTERIL SURFCE IP NO. STEEL FIXED STEEL PIN SQURE EDGES LEFT SQURE EDGES RIGHT GLVNIZED STNDRD PCKING IN BOXES OF 50 PPIECES MM B MM C MM MTERIL MM PIN MM SCREW PPROX. WEIGHT KGS / PIECES 60896 2 3 4 87 2 120 42 42 4 9,5 5,0 0,39 DJUSTBLE VERTICLLY B RIGHT THRETED PLTE B ORDERING NO. IP NO. MTERIL STEEL W/O SPECIFICTION SURFCE ELECTROPLTED STNDRD PCKING IN BOXES OF 10 PIECES MM B MM MTERIL MM THRETED HOLES MM PPROX. WEIGHT KGS / PIECES 60821 1 0 21 1 60 13 3 5 0,02 DOOR HINGE FOR TOP MOUNTING ORDERING NO. MTERIL SURFCE B IP NO. STEEL LEFT RIGHT ELECTROPL. + GREY ELECTROPL. + WHITE GLVNIZED STNDRD PCKING IN BOXES OF 10 PIECES MM B MM MTERIL MM SCREW PPROX. WEIGHT KGS / PIECES 61808 1 7 8 64 66 87 1 106 55 2,5 4,0 0,11

4.5 10 IP NO.s 60896 & 60821 FITTING INSTRUCTIONS REHU NORDIC DESIGN PLUS: 11.8 2.2 FIG. 3 FIG. 2 12.4 16.5 UPPER HINGE PRT 18 LOWER HINGE PRT CUT OUT FOR THRETED PLTE 27.5 8 60 THRETED PLTE IP NO. 60821 FIG. 1 FITTING: ON LRGE DOORS IT IS RECOMMENDED TO USE THE THRETED PLTES IP NO. 60821-10211. THESE RE CUT INTO THE PROFILE ON THE BCK OF THE FRME. USE SCREWS NO. 5 FOR THE TWO THRETED HOLES. SEE FIG. 4 ND 5. DJUSTMENT: THE HINGE IP NO. 60896 CN BE DJUSTED VERTICLLY TO WNTED POSITION BY TURNING THE SCREW IN THE BOTTOM OF THE HINGE ±3 MM. FIG. 4 THRETED PLTE MINTENNCE: TEST THE OPERTION FROM TIME TO TIME. WHEN FITTING - GRESE THE PIVOT/MOVBLE METL PRTS OF THE MECHNISM WHILE CTIVTING REPETEDLY. HEREFTER GRESE MINIMUM TWICE YER. SEE LSO INSTRUCTIONS ON PGE 28-29. FIG. 5

SIDE SWING WINDOW 90 0 DJUSTBLE IP NO.s 62896-97 11 ORDERING NO. MTERIL SURFCE IP NO. STEEL LEFT RIGHT ELECTROPLTED STNDRDPCKING IN BOXES OF 5 SETS MM B MM SCREW PPROX. WEIGHT KG / SET 62896 1 7 8 21 1 31,5 183 4,0 0.33 62897 1 7 8 21 1 31,5 326 4.0 0.53 CONVENIENT FOR CLENING SWINGS 90 OPENS CLER FROM CURTINS ND WINDOW FRME MX. VENTILTION CONCELED FITTINGS NODIZED LUMINIUM RILS VERTICLLY DJUSTBLE ± 1.5 MM B TOP FITTING BOTTOM FITTING FIRE-ESCPE OPENING: PLESE SEE WWW.IPFITTINGS.COM/RESCUE 1 SET RIGHT HND 16/11

4.5 12 IP NO.s 62896-97 FITTING INSTRUCTIONS REHU NORDIC DESIGN PLUS: MRK 2.2 11.8 ECCENTRIC PIN 16.5 FIG. 2 HORIZONTL PLN HINGE SIDE FITTING SHOWN ON FRME CILL RIGHT HND ILLUSTRTION IP NO. 62896 62897 MX. WEIGHT OF SSH KGS 20 40 MIN. FRME WIDTH MM 240 405 MX. FRME WIDTH MM 405 900 USE SCREW NO. 4.0 4.0 FIG. 3 FIG. 1 VERTICL PLN REG. TLL ND NRROW WINDOWS: PLESE NOTICE THT ON TLL ND NRROW SSHES THE FLEXIBILITY OF THE MTERIL MY EFFECT HE MOVEMENT OF THE FITTING'S SLIDING ELEMENTS IN TOP ND BOTTOM. IT CN THEREFOR BE NECESSRY TO USE BOTH HNDS TO STBILIZE THE SSH WHEN OPENING THE WINDOW. THESE FITTINGS RE NOT SUITBLE FOR DOOR HEIGHT WINDOWS. MOUNTING: 1. THE FITTING SHOULD BE POSITIONED IN THE GROOVES T HED ND CILL OF FRME GINST THE SIDEFRME ND SCREWED ON (FIGURE 1 ND 2). FSTEN THE STOP RINGS THROUGH THE MIDDLE HOLE IN THE LU-RILS. 2. OPEN THE FITTING ND PUSH THE WINDOW SSH INTO POSITION BETWEEN THE 2 FITTINGS GINST THE NGLE ND FSTEN THE SCREWS. STRT WITH THE SCREW IN THE NGLE. 3. THE OPENING BETWEEN SSH ND FRME CN BE DJUSTED BY MENS OF THE ECCENTRIC PIN - USE TORX-20 KEY. ON THE PIN IS MRK THT ON DELIVERY IS IN NEUTRL POSITION. THE PIN CN BE TURNED 90 TO ETHER SIDE, WHICH GIVES N DJUSTMENT OF ±0.5 MM. MINTENNCE: THE FITTINGS RE NOT TO BE PINTED. TEST THE OPERTION FROM TIME TO TIME. WHEN FITTING - LUBRICTE THE PIVOT/MOVBLE METL PRTS OF THE MECHNISM WHILE CTIVTING REPETEDLY. HEREFTER LUBRICTE MINIMUM TWICE YER. DO NOT LUBRICTE THE LUMINIUM RILS. SEE LSO INSTRUCTIONS ON PGE 28-29.

13 TOP SWING FITTING IP NO.s 62844-52 & IP NO. 62862 ORDERING NO. IP NO. MTERIL STEEL WITHOUT SPECIFICTION SURFCE ELECTROPLTED STNDRD PCKING IN BOXES OF 1 SET MM B MM FRME DIMENSION OUTSIDE MM SCREWS PPROX. WEIGHT KG / SET 62844 1 0 21 1 18 642 588-687 3,5 & 4,0 1,24 62845 1 0 21 1 18 742 688-787 3,5 & 4,0 1,44 B 62846 1 0 21 1 18 842 788-887 3,5 & 4,0 1,65 62847 1 0 21 1 18 942 888-987 3,5 & 4,0 1,85 1/2 SET 62848 1 0 21 1 18 1042 988-1087 3,5 & 4,0 2,05 62849 1 0 21 1 18 1142 1088-1187 3,5 & 4,0 2,25 62850 1 0 21 1 18 1242 1188-1287 3,5 & 4,0 2,45 62851 1 0 21 1 18 1342 1288-1387 3,5 & 4,0 2,66 62852 1 0 21 1 18 1442 1388-1487 3,5 & 4,0 2,86 CONCELED FITTINGS DJUSTBLE FRICTION FULLY REVERSIBLE 170 0 OPENS CLER OF CURTINS ND WINDOW FRMES NODIZED RILS FIRE-ESCPE OPENING: PLESE SEE WWW.IPFITTINGS.COM/RESCUE ORDERING NO. MTERIL SURFCE IP NO. STEEL LEFT ELECTROPLTED STNDRD PCKING IN BOXES OF 20 PCS. MM SCREW PPROX. WEIGHT KG / PC. RISTRICTOR IP NO. 62862 62862 1 7 21 1 87,5 4,0 0,05 16/11

14 IP NO.s 62844-52 & IP No. 62862 FITTING MCHINING INSTRUCTIONS REHU NORDIC DESIGN PLUS: CUT OUT IN SIDE FRME IN FULL LENGTH 12 20 5.5 3 75 R5 7 TOP FRME 10.3 4.5 DEPTH 3 MM FIG. 1 REMOVE THE INNER NOSE PLUS THE SMLL REIN- FORCEMENT ON THE OUTER NOSE IN FULL LENGTH OF SIDE SSH FIG. 3 6 3 20 17 TOP CORNER OF SIDE FRME Ø14 26 21 105 37 DEPTH 6 MM 10 HOLE IN UPPER FRME (FOR SWING ELEMENT) SEE FIG. 2 SEE FIG. 3 Ø14 X 10 DEPTH 3 MM R5 FIG. 2 FIG. 4 PROFILE ND CUT OUTS: IT IS NECESSRY TO CUT WY MTERIL IN SSH S WELL S FRME FROFILE BEFORE MOUNTING THE REVERSIBLE PROJECTING GER. LSO IT IS NECESRY TO MKE THE SSH 2 MM LESS WIDER THN FOR OTHER WINDOW TYPES. SSH: 1. SSH MUST BE MNUFCTURED SO THT THERE IS ONE MM EXTR SPCE BETWEEN SIDE FRME ND SIDE SSH COMPRED TO OTHER WINDOWS. 2. ON THE SIDE SSH THE INNER NOSE PLUS THE SMLL REINFORCEMENT ON THE OUTER NOSE HS TO BE REMOVED IN FULL LENGTH OF THE SIDE SSH. FRME: 1. THE SIDE FRME IS MDE WITH THROUGH GOING GROOVE (12 X 7 MM) PLCED 20 MM FROM FRONT EDGE OF FRME, SEE FIG. 1 ND 2. IMPORTNT: GROOVE MUST BE MDE CCORDING TO THESE SPECI- FICTIONS. EXTR TTENTION MUST BE PID TO THE GROOVES WHEN WELDING THE FRME CORNERS TOGETHER. MKE SURE THT THE PROFILE ND THE GROOVE KEEP ITS FORM, S DEFORMED PROFILE WILL CUSE PROBLEMS FOR THE RESTRICTORS ND FOR THE OPERTING OF THE GER. 2. HOLE FOR THE SWING ELEMENT HS TO BE MDE IN THE UPPER FRME, SEE FIG. 4 3. CUT OUT FOR THE BERING PLTE IN THE TOP CORNER OF THE FRME HS TO BE MDE, S SHOWN IN FIG. 2, 3 ND 4. FITTING INSTRUCTIONS - SEE NEXT PGE

5.5 15 REHU NORDIC DESIGN PLUS: IP NO.s 62844-52 & IP No. 62862 FITTING INSTRUCTIONS 4.5 2.2 11.8 TORX20 FIG. 2 12.4 16.5 FIG. 3 FITTING INSTRUCTIONS: 1. SHORTEN THE LU-RIL TO FIT THE HEIGHT OF THE INNER FRME. PLCE FITTING INTO BOTH SIDES OF THE FRME ND GINST TOP FRME ND FSTEN THE SCREWS. 2. PLCE THE BERING PLTE IN THE CUT-OUT IN TOP CORNER OF FRME ND FSTEN. THE BERING PLTE MUST BE LEVEL WITH TOP FRME ND LEVEL WITH THE SIDE FRME IN THE LOWER PRT OF THE BERING PLTE. 3. INSERT THE SSH BETWEEN HINGE RMS ND PUSH THE SSH GINST THE STOP BRCKET. FSTEN THE SSH STRTING WITH THE SCREWS IN THE STOP BRCKET. OBS: IT IS IMPORTNT THT THE STOP BRCKET IS CENTERED IN THE GROOVE. THE HINGE RMS MUST BE RESTING GINST THE SIDES OF THE GROOVE IN THE FULL LENGTH OF THE GROOVE, LSO BY THE SWING ELEMENT IN THE TOP. 4. THE SSH CN BE OPENED TO NY NGLE. FOR KEEPING IT OPEN T LRGE OPENING NGLE LIGHT FRICTION CN BE OBTINED BY MENS OF THE FRICTION SCREWS IN THE SIDES. THE FRICTION HS TO BE THE SME ON BOTH SIDES. PLESE NOTE THT THE SSH IS NOT SECURED FOR HEVY WINDS ND OTHER HEVY INFLUENCE. 5. THE SSH CN BE DJUSTED VERTICLLY ±0.75 MM BY MENS OF THE SCREW IN THE BERING PLTE (USE TORX 20), SEE TOP OF FIG. 1. MKE SURE THT THE SSH IS CENTERED IN THE FRME. 6. MKE SURE THT THE SWING ELEMENT CN MOVE FREELY INTO THE UPPER FRME, WHEN THE WINDOW IS CLOSED. 7. FIT THE RESTRICTOR IP NO. 62562 ON THE LEFT SIDE, SEE FIG. 1. PLESE CHECK RESTRICTED OPENING POSITION S WELL S CLENING POSITION. 8. IN CLENING POSITION THE TOP NOTCH SHOULD LWYS BE USED, SEE BOTTOM OF FIG 1. BOTTOM NOTCH IS FOR RESTRICTED OPENING POSITION ONLY. OPERTION INSTRUCTIONS: 1. OPEN THE WINDOW - THE RESTRICTOR WILL UTOMTICLLY RESTRICT THE WINDOW. 2. PULL THE SSH 20 MM - THE RESTRICTOR IS RELESED BY PULLING IN ON THE LITTLE FINGER IN THE BOTTOM OF THE RESTRICTOR (SEE BOTTOM OF FIG. 1). OPEN THE WINDOW. 3. WHEN THE WINDOW IS REVERSED FOR CLENING, THE RESTRICTOR WILL LOCK UTOMTICLLY. DISENGGE S MENTIONED IN POINT 2. FITTING ON FRME FIG. 1 IP N0. FINGER FITTING LENGTH MM IP NO. 62862 MX. WEIGHT KGS. 62844 642 60 62845 742 60 62846 842 60 62847 942 60 62848 1042 60 62849 1142 60 62850 1242 60 62851 1342 60 62852 1442 60 USE THE LRGEST POSSIBLE FITTING MINTENNCE: THE FITTINGS RE NOT TO BE PINTED. WHEN FITTING - LUBRICTE THE PIVOT/ MOVBLE METL PRTS OF THE MECHNISM WHILE CTIVTING REPETEDLY. HERFTER LIBRICTE MINIMUM TWICE YER. DO NOT GRESE THE LUMINIUM RILS. TEST THE OPERTION FROM TIME TO TIME. SEE LSO INSTRUCTIONS ON PGE 28-29.

16 FITTING INSTRUCTIONS

DJUSTBLE CNOPY STY WITH FRICTION IP NO.s 62886-87 & 62889 17 ORDERING NO. IP NO. MTERIL STEEL WITHOUT SPECIFICTION SURFCE ELECTROPLTED INDUSTRY PCKING IN BOXES OF 25 SETS MM B MM SCREW PPROX WEIGHT KG / SET B 62886 1 0 21 2 30 253 4,0 0,44 62887 1 0 21 2 30 486 4,0 0,78 62889 1 0 21 2 30 744 4,0 1,00 1/2 SET VERTICLLY DJUSTBLE ± 1.5 MM CONCELED FITTINGS DJUSTBLE FRICTION NODIZED LUMINIUM RILS FRICTION IN LL POSITIONS FIRE-ESCPE OPENING: PLESE SEE WWW.IPFITTINGS.COM/RESCUE

4.5 18 IP NO.s 62886-87 & 62889 FITTING INSTRUCTIONS REHU NORDIC DESIGN PLUS: 11.8 2.2 12.4 FIG. 1 16.5 IP NO. 62886 62887 62889 MX. SSH WEIGHT KG 40 50 70 MX. FRME HEIGHT MM 700 1400 1600 USE SCREW NO. 4.0 4.0 4.0 FIG. 2 OBS! RE. IP NO. 62887 FOR BIG WINDOWS (>1200 MM) WITH 3-LYER GLSS ND NO REQUIREMENTS FOR EGRESS OPENINGS THE USE OF IP NO. 62889 IS RECOMMENDED, S THE VENTILTION POSITION OTHERWISE MY BE DIFFICULT TO CHIEVE BECUSE OF THE OPENING GEOMETRY OF THE GERS. FITTING: 1. CLOSE THE FITTING ND PLCE IT IN THE GROOVE OF THE SIDE FRME. PLCE THE FITTING GINST THE TOP FRME. PLCE ND FSTEN THE SCREW IN THE BOTTOM HOLE OF THE FITTING. OPEN THE FITTING ND FSTEN THE REMINING SCREWS. FOR IP NO. 62889 FSTEN THE STOP THROUGH THE TOP SCREW HOLE. 2. PUSH THE SSH INTO ITS PLCE BY INSERTING IT BETWEEN THE FITTINGS, GUIDED BY THE GROOVES IN THE SSH, TILL THE SSH HITS THE STOPS OF THE FITTING. FSTEN THE FITTING STRTING WITH THE CREW IN THE STOP BRCKET. 62887: FSTEN THE STOP PLTE THROUGH THE UPPER SCREW HOLE IN THE STOP PLTE ND THROUGH THE UPPER SCREW HOLE IN THE LURIL. THIS ENBLES MX. FIRE ESCPE OPENING. USE LOWER SCREW HOLE IN STOP PLTE TO CHIEVE MX,. SSH LOD OF 60 KGS. IF LOWER SCREW HOLE IS USED THE FIRE ESCPE OPENING WILL BE REDUCED. 62889: LWYS USE THE UPPER SCREW HOLE IN THE LURIL FOR MOUNTING THE STOP PLTE. USE THE UPPER SCREW HOLE IN STOP PLTE FOR MX. FIRE ESCPE OPENING. USE THE MIDDLE SCREW HOLE IN THE STOP PLTE TO CHIEVE MX. SSH LOD OF 85 KGS. USE THE LOWER SCREW HOLE IN THE STOP PLTE TO CHIEVE MX. SSH LOD OF 100 KGS. IF MIDDLE OR LOWER SCREW HOLES IN STOP PLTE RE USED THE FIRE ESCPE OPENING WILL BE REDUCED. 3. NOW THE FRICTION MY BE DJUSTED BY MENS OF THE SCREWS IN THE SLIDES. THE BEST RESULT FOR THE WINDOW MOVEMENT IS CHIEVED BY EQUL FRICTION T EITHER SIDE. 4. THE SSH CN BE DJUSTED ±1.5 MM UP OR DOWN. BEFORE NY DJUSTMENT THE MOUNTING SCREWS IN THE BOTTOM IN ECH SIDE OF THE FRME HVE TO BE LOOSENED. THEN DJUST BY USING TORX-20 KEY TO TURN THE ECCENTRIC PIN. BY DELIVERY THE MRK ON THE ECCENTRIC PIN IS IN VERTICL PERSITION INDICTING THE 0-POSITION. WHEN THE MRK IS IN HORIZONTL POSTION IN EITHER TOP OR BOTTOM, THE FITTING IS DJUSTED TO IT S MX OF ±1.5 MM. FTER THE DJUSTMENT THE MOUNTINGSCREWS IN THE BOTTOM OF ECH SIDE RE FSTENED. ECCENTRIC PIN MRK FIG. 3 MINTENNCE: THE FITTINGS RE NOT TO BE PINTED. TEST THE OPERTION FROM TIME TO TIME. WHEN FITTING - LUBRICTE THE PIVOT/MOVBLE METL PRTS OF THE MECHNISM WHILE CTIVTING REPETEDLY. HEREFTER LUBRICTE MINIMUM TWICE YER. DO NOT LUBRICTE THE LUMINIUM RILS. SEE LSO INSTRUCTIONS ON PGE 28-29. 16/11

DJUSTBLE CNOPY STY WITH DJUSTBLE FRICTION IP NO. 62888 19 ORDERING NO. MTERIL SURFCE B IP NO. STEEL W/O SPECIFICTION ELECTROPLTED INDUSTRYPCKING IN BOXES OF 25 SETS 62888 1 0 21 2 30 502 4,0 0,70 MM B MM SCREW PPROX. WEIGHT KG / SET 1/2 SET VERTICLLY DJUSTBLE ± 1.5 MM DJUSTBLE FRICTION CONCELED FITTINGS NODIZED LUMINIUM RILS FIRE-ESCPE OPENING: PLESE SEE WWW.IPFITTINGS.COM/RESCUE

4.5 20 IP No. 62888 FITTING INSTRUCTIONS REHU NORDIC DESIGN PLUS: 11.8 2.2 FIG. 1 12.4 16.5 FIG. 2 IP NO. 62888 MX. SSH WEIGHT KG 70 MX. FRME HEIGHT MM 1400 SCREW 4.0 FITTING: 1. CLOSE THE FITTING ND PLCE IT IN THE GROOVE OF THE SIDE FRME. PLCE THE FITTING GINST THE TOP FRME. PLCE ND FSTEN THE SCREW IN THE BOTTOM HOLE ND THE HOLE IN THE SIDE PRT OF THE LURIL. OPEN THE FITTING ND FSTEN THE REMINING SCREWS. 2 PUSH THE SSH INTO ITS PLCE BY INSERTING IT BETWEEN THE FITTINGS, GUIDED BY THE GROOVES IN THE SSH, TILL THE SSH HITS THE STOPS OF THE FITTING. FSTEN THE FITTING STRTING WITH THE SCREW IN THE STOP BRCKET. FINLLY FSTEN THE STOP IN THE LURIL. 3. NOW THE FRICTION MY BE DJUSTED BY MENS OF THE SCREWS IN THE SLIDES. WHEN DJUSTING MKE IS SO, THT THE TOP GLIDER MOVES FIRST DOWN TO THE STOP. THE BEST RESULT FOR THE WINDOW MOVEMENT IS CHIEVED BY EQUL FRICTION T EITHER SIDE. ECCENTRIC PIN 4. THE SSH CN BE DJUSTED ±1.5 MM UP OR DOWN. BEFORE NY MRK DJUSTMENT THE MOUNTING SCREWS IN THE BOTTOM IN ECH SIDE OF THE FRME HVE TO BE LOOSENED. THEN DJUST BY USING TORX-20 KEY TO TURN THE ECCENTRIC PIN. BY DELIVERY THE MRK ON THE ECCENTRIC PIN IS IN VERTICL PERSITION INDICTING THE 0-POSITION. WHEN THE MRK IS IN HORIZONTL POSTION IN EITHER TOP OR BOTTOM, THE FITTING IS DJUSTED TO IT S MX OF ±1.5 MM. FTER THE DJUSTMENT THE MOUNTINGSCREWS IN THE BOTTOM OF ECH SIDE RE FSTENED. FIG. 3 MINTENNCE: THE FITTINGS RE NOT TO BE PINTED. TEST THE OPERTION FROM TIME TO TIME. WHEN FITTING - LUBRICTE THE PIVOT/MOVBLE METL PRTS OF THE MECHNISM WHILE CTIVTING REPETEDLY. HEREFTER LUBRICTE MINIMUM TWICE YER. DO NOT LUBRICTE THE LUMINIUM RILS. SEE LSO INSTRUCTIONS ON PGE 28-29.

21 SFETY CTCH IP NO. 62836 ORDERING NO. MTERIL SURFCE IP NO. STEEL LEFT RIGHT ELECTROPLTED STNDRDPCKING IN BOXES OF 5 SETS MM SCREW PPROX. WEIGHT KG / SET 1 SET RIGHT 62836 1 7 8 21 1 88 4,0 0,06

22 IP No. 62836 FITTING INSTRUCTIONS REHU NORDIC DESIGN PLUS: 28 11.8 2.2 4.5 MRK 12.4 16.5 X + 100 SSH X BOTTOM FRME SIDE FRME FIG. 1 RIGHT HND ILLUSTRTION FIG. 2 THE FITTING CN BE USED ON BOTH TOPHUNG/TOPGUIDED S WELL S SIDEHUNG/SIDEGUIDED WINDOWS. ON TOPHUNG/TOPGUIDED WINDOWS THE RESTRICTOR IS PLCED IN THE BOTTOM OF THE SIDE FRME ND THE RECEIVER IS PLCED IN THE BOTTOM OF THE SIDE SSH. ON THE SIDEHUNG/SIDEGUIDED WINDOWS THE RESTRICTOR IS PLCED IN TOP/BOTTOM FRME ON THE OPPOSITE SIDE OF THE HINGES ND THE RECEIVER IS PLCED IN THE TOP/BOTTOM SSH OPPOSITE THE HINGES. X-DIMENSION IS OPTIONL. BY USING LRGER X-DIMENSION THE VENTILTION OPENING WILL BE EXTENDED. IMPORTNT: THE RECEIVER MUST BE MOUNTED SO THT IT HITS THE MRK ON THE RESTRICTOR RM WHEN THE WINDOW IS CLOSED. SEE FIG. 1 OPERTING INSTRUCTIONS: 1. OPEN THE WINDOW UNTIL THE RESTRICTOR ENGGES. 2 PULL THE SSH PPROXIMTELY 20 MM BCKWRDS. 3. PRESS THE RESTRICTOR IN THE DIRECTION OF THE RROW S YOU OPEN THE WINDOW. 4. WHEN THE WINDOW IS CLOSED THE RESTRICTOR RE-ENGGES UTOMTICLLY. USE SCREW NO. 4.0 MINTENNCE: THE FITTINGS RE NOT TO BE PINTED. TEST THE OPERTION FROM TIME TO TIME. WHEN FITTING - LUBRICTE THE PIVOT/MOVBLE METL PRTS OF THE MECHNISM WHILE CTIVTING REPETEDLY. HEREFTER LUBRICTE MINIMUM TWICE YER. DO NOT LUBRICTE THE LUMINIUM RILS. SEE LSO INSTRUCTIONS ON PGE 28-29.

4,5 23 FRICTION STY for windows IP NO. 62827 ORDERING NO. MTERIL SURFCE B IP NO. STEEL LEFT RIGHT ELECTROPLTED STNDRD PCKING IN BOXES OF 25 PCS. MM B MM MTERIL MM SCREW PPROX. WEIGHT KG / PC. 62827 1 7 8 21 1 30 260 17X3 4,0 0,15 CONCELED FITTING OPENS UP TILL 100 FRICTION IN LL POSITIONS DJUSTBLE FRICTION NODIZED LUMINIUM RIL IP NO. 62827 FITTING INSTRUCTIONS 100 260 REHU NORDIC DESIGN PLUS: 11,8 2,2 135 DJUSTBLE FRICTION FIG. 1 FIG. 2 12.4 16.5 30 USE SCREW NO. 4.0 MINTENNCE: THE FITTING RE NOT TO BE PINTED. TEST THE OPERTION FROM TIME TO TIME. WHEN MOUNTING - LUBRICTE THE PIVOT/MOVBLE METL PRTS OF THE MECHNISM WHILE CTIVTING REPETEDLY. HERFTER LUBRICTE MINIMUM TWICE YER. DO NOT LUBRICTE THE LUMINIUM RIL. SEE LSO INSTRUCTIONS ON PGE 28-29. FIG. 3

4,5 24 FRICTION STY for doors IP NO. 63811 ORDERING NO. MTERIL SURFCE IP NO. STEEL LEFT RIGHT ELECTROPLTED STNDRD PCKING IN BOXES OF 10 PCS. MM B MM MTERIL MM SCREW PPROX. WEIGHT KG / PCS. B 63811 1 7 8 21 1 30 400 17X3 4,0 0,24 CONCELED FITTING OPENS UP TILL 100 FRICTION IN LL POSITIONS DJUSTBLE FRICTION NODIZED LUMINIUM RIL IP NO. 63811 FITTING INSTRUCTIONS REHU NORDIC DESIGN PLUS: 250 400 11,8 2,2 DJUSTBLE FRICTION 200 30 FIG. 1 FIG. 2 12.4 16.5 USE SCREW NO. 4.0 MINTENNCE: THE FITTING RE NOT TO BE PINTED. TEST THE OPERTION FROM TIME TO TIME. WHEN MOUNTING - LUBRICTE THE PIVOT/MOVBLE METL PRTS OF THE MECHNISM WHILE CTIVTING REPETEDLY. HERFTER LUBRICTE MINIMUM TWICE YER. DO NOT LUBRICTE THE LUMINIUM RIL. SEE LSO INSTRUCTIONS ON PGE 28-29. FIG. 3

25 CCESSORIES IP NO.s 62822 & 63830 ORDERING NO. IP NO. MTERIL LUMINIUM PLSTIC WITHOUT SPECIFICTION SURFCE NODIZED WHITE STNDRD PCKING IN BOXES OF 20 PIECES STNDRD PCKING IN BOXES OF 25 PIECES MM B MM C MM SCREW PPROX. WEIGHT KG / PIECES 62822 0-0 00 - - 1 40 29,4 19,8 4,0 0,02 63830-9 0-56 1-30,3 24 12 4,0 0,01 C B SUPPORT FITTING IP NO. 62822 C B GUIDE BLOCK IP NO. 63830

26 CSEMENT HOOKS & FITTING CSEMENT INSTRUCTIONS FSTENERS ORDERING NO. MTERIL SURFCE B B IP NO. ZINK LLOY W/O SPECIFICTION ELECTROPLTED / WHITE ELECTROPLTED ELECTROPLTED YELLOW STNDRD PCKING IN BOXES OF 50 PIECES INDUSTRY PCKING IN BOXES OF 250 PIECES MM B MM HOLE FOR PIN MM PPROX. WEIGHT KG / 100 PIECES 21371 21379 21371 0 0 06 21 25-2 130 95 6 6,0 0 0-21 25 1-21379 120 93 6 5,6 0 0 06 21 25-2 TTENTION: IP NO. 21379 IN POWDER PINTED VERSIONS CN ONLY BE USED TOGETHER WITH IP NO. 21382. B MTERIL ORDERING NO. SURFCE 21382 IP NO. STEEL W/O SPECIFICTION ELECTROPLTED / WHITE ELECTROPLTED ELECTROPLTED YELLOW STNDRD PCKING IN BOXES OF 50 PIECES INDUSTRY PCKING IN BOXES OF 250 PIECES INDUSTRY PCKING IN BOXES OF 500 PIECES MM B MM PIN MM SCREW PPROX. WEIGHT KG / 100 PIECES B 1 0-21 25 1 - - 21382 13,3 34 5,6 3,5 0,75 1 0 06-25 - 2-21396 1 0 06 21 25 - - 2 24 50-3,5 5,0 21396 18.08

27 FITTING INSTRUCTIONS IP NO. 21371 + 21379 + 21382 DRILL 5 MM HOLE FOR RING SCREW SSH 3,5 FRME 11 11 28,5 28 11 22 FIG. 1 IP NO. 21382 FIG. 2 IP NO. 21371 WITH 21382 FIG. 3 IP NO. 21379 WITH 21382 IP NO. 21396 SSH FRME FRME 23 12 11 7 28 22 28,5 SSH SSH FRME FITTING: 1. MOUNT THE RECEIVER 1 IN THE WNTED HEIGHT ON THE SIDEFRME. 2. FOR CSEMENT FSTENERS WITH SCREW PLTE 2 MESURE PRECISELY ON THE SSH ND PRE-DRILL FOR THE RING SCREW. MRK UP THE 2 SCREW HOLES ON THE SCREW PLTE ND FSTEN THE CSEMENT FSTENER. 17/05

28 MINTENNCE FITTING LUBRICTION INSTRUCTIONS GENERLLY all parts of a building have to be looked after and maintained from time to time. This of course also applies for fi ttings in windows and doors. How often fi ttings in windows and doors should be maintained depends to a large extent on how they are used, how often they are operated, and not least on the environment the fi ttings are exposed to. Corrosion may also be caused by other factors, such as corrosive liquids, air pollution etc. Special attention should be given to fi ttings used in windows and doors in urban and industrial areas or other areas with a high traffi c intensity as well as coastal areas. Fittings in such environments should be checked and greased more often than fi ttings used in areas with less corrosive effects. HINGES ND FITTINGS should be lubricated when necessary, or at the minimum twice a year. SLIDING ELEMENTS S WELL S LL LURILS with sliding surfaces are to be kept clean and free from dust and dirt to ensure a smooth sliding function. Stearin wax or a clean lubricating fi lm (but no oil and no grease!) can be applied onto the alluminium rails. ESPGNOLETTES ND OTHER LOCKING FITTINGS should be greased or lubricated with acid free grease or acid free oil on spray. The grease/oil should be applied into the mechanism box as well as on the joints of the side bolts, the roller bolts, or the mushroom head bolts while activating the mechanism repeatedly. Grease or lubricate when necessary or at the minimum twice a year. Continues...

29 MINTENNCE LUBRICTION INSTRUCTIONS BRSS will sooner or later get some discoloration in a brownish tone depending on the environment in which it is placed. The original brass surface can be maintained by polishing from time to time. STINLESS STEEL can get some discoloration, although this rarely happens. Different chemical infl uences like acid fumes, contamination from wood preservation treatments, or air pollution may cause discoloration of the metal, sometimes to a reddish tone which could look like rust. Thin discoloration can be removed just by using common cleaner or polish. PINTED FITTINGS will from time to time need repainting. Before painting all parts should be cleaned carefully. When choosing type of paint and when applying the paint remember to follow the instructions from the paint manufacturer very carefully. When painting a wooden window in a house, it is a good idea also to paint the visible parts of the fi ttings (please note: No alurails nor sliding parts should ever be painted!). The painting of the fi tting will minimize corrosion and add to the lifetime of the fi tting. lways make sure that the proper function of a fi tting is not affected by the painting. NODIZED LUMINIUM should be cleaned from time to time, depending on the surroundings in which it is placed. Cleaning of the surface with a cloth or sponge is recommended. Eventually a neutral solvent can be used. Emery cloth, steel wool, sodium carbonate, and other cleansers or abrasives containing alkalies or acid should never be used. ON THE WINDOW ND DOOR FCTORY SITE all fittings should be lubricated or greased before shipment. Hinges should be lubricated with acidfree oil while activating repeatedly, an acidfree grease can also be used. When using grease it should be applied directly onto the pin of the hinges. It may be necessary to dismantle the sash before greasing. Especially hinges with a brass pin should be greased. When mounting fi ttings, please make sure that the tools do not damage the original surface treatment. When original surface has been damaged make sure that remedial take place as soon as possible. WHEN IN DOUBT PLESE CONTCT YOUR LOCL SUPPLIER OR /S J. PETERSENS BESLGFBRIK.

30 FITTING NOTES INSTRUCTIONS

/S J. PETERSENS BESLGFBRIK JCOB PETERSENSVEJ 9, DK-9240 NIBE TEL.: (+45) 98 35 15 00 www.ipafittings.com ipa@ipafi ttings.com