CONVERTITORE ECONOMICO PER MISURATORE ELETTROMAGNETICO DI PORTATA LOW COST CONVERTER FOR ELECTROMAGNETIC FLOW METER

Similar documents
ISOMAG Millennium ML 210 A QUADRO 210 PANEL MOUNTING VERSION ML 210 VERSIONE A PARETE ML 210 WALL VERSION

ISOMAG UNIQUE PID REGULATOR + MAG CONVERTER THE FRIENDLY MAG METER

ISOMAG Millennium ML 210 A QUADRO 210 PANEL MOUNTING VERSION ML 210 VERSIONE A PARETE ML 210 WALL VERSION

FAST SAMPLING CONVERTER

( F L O W I Z F A M I L Y )

TU SERIES. SENSORI ULTRASONICI M30 - SERIE TU TU series - M30 ultrasonic SENSORS TU 1 / C 0-0 E

Warranty conditions are available on this website: only in English version

FLOWIZ ( M L ) Warranty conditions are available on this website: only in English version

Millenium ML110 CONVERTER OPERATING & INSTALLATION MANUAL

USER MANUAL 2AMIN514VPBS

OPERATING AND INSTALLATION MANUAL CONVERTER

ISOIL ML210 CONVERTER For use with ELECTROMAGNETIC FLOWMETERS

SITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview

USER MANUAL 2AMCV551VPBS

Serie FQ / FQ Series

R&D TECHNICAL SPECIFI

ELETTRONICA DUE. Serie / Series C - 3X Contaimpulsi bidirezionali multifunzione DIN 72X72 DIN 72X72 µ Processor Multifunction up / down counter FOTEK

APPENDIX APPENDIX A 1

FOTOCELLULE CILINDRICHE M18 TASTEGGIO DIRETTO PHOTOELECTRIC CYLINDRICAL SENSORS DIFFUSE TYPE

Electromagnetic Flow Transmitter

EGC100W MAGMAX. Converter for Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification

FLOMID-MX Control unit for electromagnetic flowmeters USERS MANUAL. instrumentación para fluidos. Realitzat: Revisat R+D Electrònic: Aprovat: Data:

Flow - Rotor. Characteristics. Applications. Mechanical-magnetical, Infrared. Quantity measurement for filling processes

FLOMID FX Electromagnetic Flowmeter

Sistema di connessione LED Chip Array / LED Chip array connection system

Digital flow transmitter for continuous flow measurement

Supercal 531 Multi function Integrator that lives up to Your highest expectations

Digital flowmeter for continuous flow measurement

Digital flowmeter for continuous flow measurement

DM series M12 cylindrical photoelectric sensors

SITRANS F flowmeters SITRANS F US. SONOFLO SONO 3000 transmitter. 4/152 Siemens FI Overview

SITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview

Electro-Magnetic Flowmeters COPA-XE

Level Limit Switch nivotester FTL 325 P

Ultrasonic level transmitter, non-contact

Type PLC Fitting. Valve for Continuous control. Diaphragm valve. Output

KMS101W. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Wafer Flowmeters with S100 display

MHCO MHCO-RI. General Characteristics The transducer MHCO provide a measurement of current or voltage fully isolated and safe.

CURRENT/FREQUENCY CONVERTER S 104

Digital batch controller

Customer: Standard type Page 1 of 7 Description Fluxgate current sensor with toroidal core PCB mounting

MID. Energy Management Energy Analyzer Type EM11 DIN. Product Description. How to order EM11 DIN AV8 1 X O1 PF. Type Selection EM11 DIN

MULTICAL Energy meter TS PTB. Application

Valve Island with Electronic I/O

Flow Switch - 2 programmable thresholds. Stand Alone (Battery) - Battery powered, - 2 totalizers display, - Local flow display,

LST400 Ultrasonic level / open channel flow transmitter

TEK-TEMP 2100A. Explosion-Proof Temperature Transmitter. TEMPERATURE. Technology Solutions

The transducer component converts the measured signal and displays the actual value.

DM series M12 cylindrical photoelectric sensors

ph / ORP Measurement mypro CPM 431

minimal installation depth: 57 mm without plug-in terminal min-/max-value recording display flashing at threshold exceedance / undershooting

Power analyzers and Energy Meters Power Analyzer Type WM14-96

Magnetic-inductive flow meter. PITe / UMF2. Technical Datasheet. Maintenance-free Nearly no pressure drop Robust design Easy installation and start-up

} Max. Load Resistance : 750Ω when power supply voltage is 24V DC (Max. load resistance (Ω) = 50x Power Supply Voltage -450 ).

Multifunction network analyzer Q15U Q96U2L - Q96U4... Q15E Q96E MCU - MCUH Programmable transducer MCUU

J Series induq VMZ MAGNETIC INDUCTIVE FLOW SENSORS. DB_Magnetic_Inductive_Flow_Sensors 05/2016

BS-BV SERIES. SENSORI FOTOELETTRICI RETTANGOLARI - SERIE BS-BV BS-BV series - rectangular photoelectric sensors BS 2 / C

KMS305W. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Wafer Flowmeters with S300 display

Power analyzers and Energy Meters. Multifunction indicator. Type WM12-DIN. Product Description. How to order WM12-DIN AV5 3 D X.

Energy Management Power Analyzer with plug-in Output Modules Type W M22-DIN

B850 Boiler House Energy Monitor

Digital inductive conductivity transmitter

Customer: Standard type Page 1 of 7 Description Fluxgate current sensor with toroidal core PCB mounting

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

IS-3000 SERIES INFRARED SCANNER

Model Sono-Trak Transit Time

Operation. Displayed channel. Measuring range. Status indication/ remote control Key lock Measuring mode/ time constant. Scale.

LKAT2 Portable. High Current, Portable, Multi-size Head AC / DC Current Measurement System. Application Examples. Key Features

S103C ELECTROMAGNETIC FLOW METERS. Main application fields MOUNTING

Flow - Rotor. Characteristics. Applications. Mechanical-magnetical, Infrared. Quantity measurement for filling processes

INTRODUCING SOME GREAT NEW PRODUCTS FROM OUR DWYER INSTRUMENTS RANGE:

minimal installation depth: 25 mm without plug-in terminal min-/max-value recording display flashing at threshold exceedance / undershooting

Efcon Water. Installation & User Manual Electro Magnetic Flowmeter (EMF) Efcon Water compact Electro Magnetic Flowmeter (EMF) Manual Version UK

EXPERT-LINE. KOBO-pH. Transmitter for ph-value and ORP Model APM-X

DOCUMENTATION. Its affordable price allows you to meet your budget target.

High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals

B850 Boiler House Energy Monitor

Energy Management. Type WM14-DIN Basic Version. How to order WM14-DIN AV5 3 D PGX. Type Selection. Input specifications. CptBSoft

6.00 INFRARED ANALYZER

The Radar Level Meters can be installed both in metallic or non metallic tanks; their use is not harmful to humans or environment.

Measurement. SITRANS F US Inline. 3/262 Siemens FI Transmitter SITRANS FUS080/FUE080

Power analyzers and Energy Meters Power Analyzer Type WM14-DIN

Model Range code System Power supply Option. variables. Housing for panel mounting, (front) protection degree IP50 and optional RS485 serial output.

INSTRUCTION MANUAL Redox sensor M 1322 C

PHOTOELECTRIC S300 MAXI SENSORS APPLICATIONS.

BATCHFLUX 5500 C Technical Datasheet

UMF. Transmitter for magnetic-inductive flowmeters. Operating Instructions

Energy Management Energy Meter with plug-in Output Modules Type EM4-DIN

KFS. Flap-type flow meter. Design and range of application

ABB MEASUREMENT & ANALYTICS DATA SHEET. Ultrasonic level LST400 Open channel flow transmitter

MS 5000 CIAO SENSOR EXTREMELY EASY TO INSTALL THANKS TO PATENTED WRAPPER FIXING SYSTEM

T/3000 T/3000. Substation Maintenance and Commissioning Test Equipment

Technical Information Nivector FTC968, FTC968Z

Design and applications

MIM. Electromagnetic Flowmeter. Compact, All-metal Design

02/11/2015

Brunata Optuna H. Properties. Counter

Nivotester FTR325. Technical Information. 1-channel switch amplifier for the microwave barrier Soliwave FDR50/FQR50

Operating Instructions

Series 10-ZSE30A(F)/10-ISE30A

Transcription:

M I S U R A T O R I E L E T T R O M A G N E T I C I D I P O R T A T A S E R I E E L E C T R O M A G N E T I C F L O W M E T E R S E R I E S ISOMAG Millennium CONVERTER MODEL M L 1 1 0 CONVERTITORE ECONOMICO PER MISURATORE ELETTROMAGNETICO DI PORTATA LOW COST CONVERTER FOR ELECTROMAGNETIC FLOW METER ML 110 VERSIONE COMPATTA ML 110 COMPACT VERSION

SPECIFICA TECNICA Data Documento 15/10/03 Pagine 2/6 DATI TECNICI / TECHNICAL DATA Materiale custodia Housing Material Dimensioni / Dimensions Classe di protezione Protection rate Cavi connessione - Pressacavi Connection sensor cable/ Cable gland Temperatura ambiente/ Ambient Temperature Display LCD Tastiera di programmazione Programming key board Uscita impulsi/frequenza/allarmi Pulse / frequency/alarm output Uscita in corrente Current output Misura bidirezionale Bi-directional Valore di F.S. / FS value Funzione di autodiagnosi Diagnostic funct. Rilevazione tubo vuoto Empty pipe detect. Separazione galvanica Galvanic isolation Memorizzazione dati Data storage Presa programmazione Programming plug in Certificazione CE CE certification Incertezza delle misure Measurements tolerance Nylon caricato fibra vetro / Nylon with fiber glass 120 X 120 X 55 mm IP 65 C018 cable ( MAX 20 m ) / Standard N 3 PG 11 0 +50 C Display alfanumerico 16 caratteri x 2 righe non illuminato Alphanumerical display 16 characters x 2 rows not back light N 3 tasti interni / 3 internal keys N 2 funzioni programmabili / programmable function max 1250 Hz, 100mA, 40 Vdc N 1 0/4 20mA RL 800W Sì / Yes 0,4 10m/s Sì / Yes Sì / Yes Tutte le uscite sono separati tra loro e dall alimentazione All the outputs are galvanically isolated from power supply In mancanza di alimentazione i dati vengono memorizzati in una Eeprom / Eeprom stored measuring values on power failure Presa protetta per collegamento PC o terminale portatile Protected plug in for connection to PC or hand terminal Strumento certificato CE / Instrument with CE certificate Portata (volume) = ±0,1 % v.l./flow rate (volume) = ±0,1% v.l. Out 4/20 ma = ± 0,12 % v.l. Out Frequenza = ± 0,12% v.l. / Frequency Out = ± 0,12% v.l. Ripetibilità / Ripetibility +/- 0,2 % Alimentazione Power supply 90 265 Vac 45 66 Hz; 10 63Vdc/15 45 Vac-45 66Hz; Consumo / Consumption 5 VA 4 VA ( AC ) / 3 W max ( DC )

25 SPECIFICA TECNICA Data Documento 15/10/03 Pagine 3/6 DIMENSIONI D INGOMBRO / OVERALL DIMENSIONS 127 65 79 129 168 124

SPECIFICA TECNICA Data Documento 15/10/03 Pagine 4/6 1.SENSOR 1.1 ND 1.2 KA 1.3 KL + / - 1.4 E.P.DETECT 1.5 AUTOZERO CAL. 1.6 E.P. CALIBR. SET ND SET KA SET KL ON/OFF 2.SCALE 2.1 FS1 2.2 FS2 2.3 MU.TOT 2.4 IMP1 2.5 IMP 2 2.6 TPUL 1 2.7 TPUL 2 2.8 FRQ1 2.9 FRQ2 FULL SCALE 1 FULL SCALE 2 VALUE SET MEASURE UNIT PULSE CH. 2 PULSE CH. 1 DUR. PULSE CH.1 DUR. PULSE CH.2 F.S.FREQ. CH.1 F.S.FREQ. CH.2 VOLUME UNIT VOLUME UNIT TYPE OF UNIT MEASURE UNIT MEASURE UNIT TYPE OF UNIT TYPE OF UNIT N DECIMAL TOT. TYPE OF UNIT TYPE OF UNIT TIM. UN. MEASURE TIM. UN. MEASURE NUMERIC VALUE NUMERIC VALUE NUMERIC VALUE NUMERIC VALUE 3.MEASURE 3.1 T. CONST 3.2 SKIP THR 3.3 PEAK THR 3.4 CUT-OFF 3.5 FILTER 3.6 AUTOCAL. 3.7 AUTORANGE 3.8 E. SAVING TIME CONTANT ACC. THRESHOLD PICK CUT OFF TH. LOW FLOW TH. SET FILTRE 50/60Hz AUTOCALIB FUN. AUTO CH. SCALE 4.ALARM 4.1 MAX THR 4.2 MIN THR 4.3 HYST 4.4 E.P. THR 4.5 ma VAL.FAULT 4.6 Hz VAL.FAULT MAX.FLOW RATE MIN.FLOW RATE HYSTERESIS TH. EMPTY PIPE TH. 4/20 ma ALARM SET FREQUENCY ALARM 6.OUTPUT 6.1 OUT.1 6.2 OUT.2 6.3 DUTY CYCLE 6.4 OUT.MA1 SEE THE TAB REFER TO THE FUNCTIONS FOR OUTPUTS: MENU 6 "OUTPUT" CHOOSE CUR.VALUE 8. DISPLAY 8.1 LANGUAGE 8.2 D.RATE 8.3 CONTRAST 8.4 RESET T+ 8.5 RESET P+ 8.6 RESET T- 8.7 RESET P- REFRESH DISPLAY CONTRAST SET RESET + TOTALIZER RESET PARTIAL + RESET - TOTALIZER RESET PARTIAL - 8.8 CURRENCY 8.9 CUR. DECIM. 8.10 XXX/dm³ + 8.11 XXX/dm³ - EN. CURRENCY CHOICE DEC. CURR. CONV. FACTOR+ CONV. FACTOR- 10.DIAGN. 10.1 CALIBRATION 10.2 SELFTEST 10.3 SIMULATION CALIBRATION METER AUTOTEST F.R. SIMULATION 11.INT. DATA 11.1 L2 KEYCODE 11.2 LOAD FACT. PRES. 11.3 LOAD USER PRES. 11.4 SAVE USER PRES. 11.5 HOURS 11.6 KS LIVELL 2 CODE FACTORY RECALL USER RECALL USER SAVE OPERATION TIME SET KS

SPECIFICA TECNICA Data Documento 15/10/03 Pagine 5/6 CONNESSIONI ELETTRICHE /ELECTRICAL CONNECTIONS VISTA MORSETTIERA / TERMINAL BOARD 24V - OUT2 OUT1 24V E C E C + COILS SC B2 B1 SC 1 2 3 4 5 6 7 8 9 10 20 19 18 17 16 15 14 13 12 11 11 12 13 14 15 16 17 18 19 20 10 9 8 7 6 5 4 3 2 1 + - 4-20mA SC C E2 E1 ELECTRODES ON/OFF OUTPUT Terminal 16 18 (Out 1) (Out 2) 43 V Terminal 17 19 (Out 1) (Out 2) +24V INTERNAL ANALOG OUTPUT I ma Terminal (9+) 0/4..20mA OUT 24V COMMON Terminal (10-)

SPECIFICA TECNICA Data Documento 15/10/03 Pagine 6/6 COME ORDINARE / HOW ORDER VERSIONE COMPATTA COMPACT VERSION VERSIONE SEPARATA SEPARATE VERSION 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Uscita / output 0/4...20/22 ma >HV< 90..265VAC >LV< 15...45VAC 10...63VDC ML 110 Display A Versione cieca (senza display ) / Blind execution (without display and programming keys) B Versione con display alfanumerico a 2 righe da 16 cifre e tastiera interna di programmazione ( a 3 tasti) / Complete with 2 line back light display (each of 16 characters) and 3 programming keys Materiale custodia convertitore - Classe di protezione / Housing material - Protection rate 0 Nylon caricato fibra vetro ( IP 65 ) /Nylon with glass fiber (IP 65) Versione / Version A Versione compatta, con sensore MS... (massima temperatura del liquido 100 C) / Compact version with sensor MS... (liquid maximum temperature 100 C) B Esecuzione separata da campo per accoppiamento a sensori MS..., / Separate version for wall monting, complete with mounting accessories ( USARE CAVO C018 ) (C018 CABLE) Alimentazione / / Power supply 1 2 9 Alimentazione : 90... 265 V 45/66 Hz Alimentazione : 18...63 V dc / 15 45 V ac - 45...66 Hz Alimentazione : altre Uscita analogica / Analogue / output A Senza uscita analogica / Without analogue output B Uscita analogica 0/4 20/22 ma / Analogue output 0/4...20/22 ma / Power supply : 90... 265 V 45/66 Hz / Power supply : 18...63 V dc / 15...45 V ac - 45...66 Hz / Power supply : other ML 110 A 0 A 1 A ESEMPIO DI CODICE PER L'ORDINE/ EXAMPLE OF CODE FOR ORDER ATTENZIONE/WARNING I DATI POSSONO CAMBIARE SENZA ALCUN PREAVVISO/THE ABOVE DATA CAN BE CHANGED WITHOUT NOTICE