FLEXIBLE CURRENT PROBES

Similar documents
FlexProbe FLEXIBLE AC CURRENT PROBE. User Manual. FlexProbe ON OL 1000V CAT III 300A 3000A OFF

MiniFlex MF MF FLEXIBLE AC CURRENT SENSOR. User Manual

MiniFlex MF HF MF HF FLEXIBLE AC CURRENT SENSOR. User Manual. High Frequency Response for Oscilloscopes

CLAMP-ON METER. Models 500, 501, 502, 503, 511, 512 & 514. Call toll free (800) or visit

AC/DC Current Probes Model MR411 Model MR521

AC/DC Current Oscilloscope Probe Model SL261

MR461 MR561 AC/DC OSCILLOSCOPE CURRENT PROBES. User Manual. AC/DC CURRENT PROBE Model MR 561. AC/DC CURRENT PROBE Model MR V CAT III - 600A

TRMS LEAKAGE CURRENT CLAMP-ON METER 565

Flexible AC current probes

CM605. User Manual AC/DC LOW CURRENT CLAMP-ON METER ENGLISH

E Series 9.00 (1/2) E series

Wide-band Models from DC to 100 MHz

FALL-OF-POTENTIAL GROUND RESISTANCE TESTER

10.00 (1/2) PAC series

CLAMP-ON METER 670. User Manual

SERIE E N. The E N series clamps use Hall-effect technology for the measurement of AC and DC currents from several milliamps to over 100 A.

Wide-band Models from DC to 100 MHz

Digital Ground Resistance Tester. Model 4610 & 4610 Kits

Wide-band Models from DC to 100 MHz

Fluke 370 FC Series True-rms Wireless AC/DC Clamp Meters

TORKEL 900-series Battery Load Unit

TORKEL 900-series Battery Load Unit

Current clamps for AC current

AC FLEXIBLE CURRENT PROBE CA 3000

AC/DC current clamps (1/2) E N series

Preface Shenzhen Zhiyong Electronics Co., Ltd. First of all, thank you for purchasing our products, this instruction manual is the description about t

current clamps catalogue

Preface First of all, thank you for purchasing our products, this instruction manual is the description about the function, usage, operation attention

Current Clamps. Catalogue

Fault Mapper Cable Length Meter & Fault Locator Alphanumeric TDR Model CA7024

GROUND FAULT/LEAKAGE DETECTOR

Fluke 370 FC Series true-rms wireless AC/DC clamp meters

METRAClip85 and 86 Clamp Multimeters

374/375/376 Clamp Meter. Users Manual

GROUND TESTERS For all of your Ground Testing needs...

Fluke 370 FC Series True-rms Wireless AC/DC Clamp Meters

PT-2000series AC/DCcurrentprobe PT-2710 PT-2720 PT-2740 PT-2770 MANUAL INSTRUCTION

Preface Shenzhen Zhiyong Electronics Co., Ltd. First of all, thank you for purchasing our products, the product specification is about the function, u

Fluke 355 and 353 True-rms 2000 A Clamp Meters Versatile and rugged tools for applications with high currents

Agilent 1146A AC/DC Oscilloscope Current Probe

METRAClip87 and 88 Clamp Multimeters

80i-110s AC/DC CURRENT PROBE

374/375/376 Clamp Meter

Current clamps for AC current

Current Clamp TP-CC80. User s manual. Rev. 1.1

K1 K2. User's manual AC/DC CURRENT PROBE C H A U V IN A R N O U X AC/DC CURRENT PROBE. 1 mv/ma OFF 300V CAT II

with the Artifical Neutral AN-1

DM-III Multitest & DM-III Multitest F Power Quality Recorders

Non-Contact Capacitance Gauging Instrument & Series 2800 Capacitive Probes

User s Manual Current Probe. IM E 2nd Edition. Yokogawa Electric Corporation

DC/AC CLAMP METER ISO-TECH 2000 USERS MANUAL

Clamp-On Harmonic Probe Model 725 OFF V. Model 725 HARMONIC METER AEMC. TDHF K FACTOR khz AV% ODD RECORD-PAUSE MAX MIN AVG

netzerotools.com 374/375/376 Users Manual Clamp Meter

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com # # AAC Clamp Meter. Instruction Manual

DM-5 Power Quality Analyzer

Featured Product: New Features in DataView Customer Support Tip: Connecting a Simple Logger II to the Data Logger Control Panel

HHMA2 DC / TRUE RMS AC NON-CONTACT MILLIAMMETER

User s Guide. 400A AC/DC Clamp Meter. Model MA Washington Street Melrose, MA Phone Toll Free

USER'S MANUAL ACDC-100 TRMS ACDC-100. Versatile AC/DC Clamp-on Multimeter Series

QUICK TESTER FOR TRANSFORMERS AND CAPACITORS

Fluke Fluke-Direct.ca. Three-Phase Power Logger. Technical Data

SINGLE-PHASE POWER QUALITY ANALYZER. User Manual ENGLISH

USER MANUAL. Model MA A AC Clamp Meter DMM Model MA445 True RMS 400A AC/DC Clamp Meter DMM

AC/DC CLAMP METER CM4371, CM4373

1587/1577 Insulation Multimeters

User s Guide. 400A AC/DC Clamp Meter. Model MA220

Pince Multimètre - Courants de fuites Leakage Clamp-on Meter Multimeter und Fehlerstrom-Messzange Pinza Multimetro - Correnti di fuga

DIGITAL MULTIMETER with Non-Contact Detection

APPA 300 Series. The Most User-Friendly High Performance Multimeter

Simple measurement at the best price

DM-III MULTITEST Power Quality Recorder

User s Manual Current Probe. IM E 2nd Edition IM E

79/26 Series III Multimeter

DIGITAL MULTIMETER with Non-Contact Detection

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

34134A AC/DC DMM Current Probe. User s Guide. Publication number April 2009

Clamp-On Ground Resistance Tester Model 3705

IMPORTANT WARRANTY NOTE:

600A Clamp Meters w/tightsight Display

Measure voltage without test leads. Product Highlights

Clamp-on Testers. 300 Series and CL Series of Clamp-on Testers. Series

Safety Warnings Features Specifications Instrument Layout Operation Preparation AC Current Measurement How to Use Peak Hold Function How to Use The

Installation Tester and DMM Kits

CABLE TESTER. Models CA7024, CA7026 & CA7028. Call toll free (800) or visit

DIGITAL ANALOG MEGOHMMETERS

374/375/376 Clamp Meter

Safety Warnings Features Specifications Instrument Layout Operation Preparation AC Current Measurement How to Use Peak Hold Function How to Use The

AC/DC CLAMP METER CM4370 series

400Amp True RMS AC/DC Clamp Meter Model EX613

USER MANUAL 600A AC Clamp Meter + NCV Model MA610

Electrical measurement technology. Re-invented.

AC/DC Clamp Meter. Owner's Manual. Model No Safety Operation Maintenance Español

Fluke 712B and 714B Temperature Calibrators

LH240 LH1040 LH2040 LH2015

Quick Start Guide AT-6000 Advanced Wire Tracer Series

Fluke 1740 Series. Three-Phase Power Quality Loggers Memobox. Assess power quality and conduct long-term studies with ease

ET-3888 True RMS Clamp Meter. User Manual

GROUND RESISTANCE TESTERS

AC/DC CLAMP METER CM4370 series

MEGOHMMETER. User Manual

Transcription:

FLEXIBLE CURRENT PROBES AmpFlex, LongLife AmpFlex & FlexProbe Ranges from 30 to 30,000Arms (AmpFlex Flexible Current Probes) Single or dual range to measure up to 3000A (LongLife AmpFlex Flexible Current Probes) Dual measurement ranges of 300A and 3000AAC (FlexProbe Flexible Current Probes) Shape Memory for custom pre-shaping of sensor before use (no drooping)

AMPFLEX Flexible Current Probes Model 1000-24-2-1 The AmpFlex is an AC current probe composed of a flexible sensor and an electronic module. The flexible sensor permits measurements on conductors where standard clamp-on probes cannot be used. In particular, it can be installed in tight spaces, around cable bundles, around wide or large bus bars, or even wrapped around irregular shapes. The Shape Memory feature enables the user to pre-shape the sensor before inserting it between or around conductors. This feature facilitates positioning the sensor around the conductor, enhances user safety and alleviates the drooping effect associated with other flexible sensors that require reaching around the conductor to complete the loop. FEATURES Models ranging from 30 to 30,000Arms Accuracy 1% of Reading TRMS measurements when connected to a TRMS instrument No core saturation or damage if overloaded Overrange LED for measurement circuitry Waterproof sensor 9V Alkaline battery, provides typical 150 hour continuous operation Shape Memory for custom pre-shaping of sensor before use (no drooping) Very high frequency response Low phase shift for power measurements Insensitive to DC, measures only AC component on DC + AC signals Excellent linearity Lightweight EN 61010, 1000V Cat. III (sensor); EN 61010, 600V Cat. III (module) APPLICATIONS Measuring around wide bus bars Measuring crowded circuit breaker panels Measuring around large cable bundles Measuring in any traditional application Measuring around irregular shapes The AmpFlex is lightweight and does not use magnetic cores like standard transformers. The transformation principle is based on an air core. It presents virtually no load to the system under test, has a low phase shift and excellent frequency response, and cannot be damaged by current overloads. The sensor assembly is waterproof and insulated for 1000V working voltage. The AmpFlex has a millivolt output proportional to the current measured for direct readings on DMMs, loggers, oscilloscopes and power or harmonic meters. The length of the flexible sensor can be selected from 24" (450mm) to 60" (1520mm). Longer lengths are available. Flexibility to easily measure where standard clamp-ons cannot! 2 www.aemc.com Technical Assistance (800) 343-1391

SPECIFICATIONS ELECTRICAL Current Range 30A 200A 300A 300A 30/300A 500A 50/500A 1000A 100/1000A 3000A Measurement Range 5 to 30A 5 to 200A 5 to 300A 5 to 300A 5 to 300A 5 to 500A 5 to 500A 5 to 1000A 5 to 1000A 5 to 3000A Output Signal(s) 100mV/A 10mV/A 100mV/A 10mV/A 10mV/A 10mV/A Crest Factor (mid-range) 3.0 >10 3.0 >10 3.0 >10 >10 9.0 9.0 3.0 Phase Shift @ 50/60Hz 1.3 0.7 0.7 0.7 1.3 0.7 0.7 0.7 0.7 0.7 Residual Noise 200mA 200mA 200mA 200mA 200mA 200mA 200mA 200mA 200mA 200mA ELECTRICAL Current Range 300/3000A 300/3000A 6000A 600/6000A 10,000A 1000/10,000A 30,000A 3000/30,000A Measurement Range 5 to 3000A 5 to 3000A 5 to 6000A 5 to 10,000A 5 to 10,000A 5 to 10,000A 5 to 30,000A 5 to 30,000A Output Signal(s) 10mV/A 3.3mV/A 0. 0. 0. 0.3mV/A 0. 0. 0. Crest Factor (mid-range) 3.0 3.0 >10 >10 9.0 9.0 3.0 3.0 Phase Shift @ 50/60Hz 0.7 0.7 0.5 0.5 0.5 0.5 0.5 0.5 Residual Noise 200mA 200mA 500mA 500mA 500mA 1A 1A 1A ELECTRICAL COMMON Accuracy 1% of Reading Frequency Range 10 to 20,000Hz* Working Voltage EN 61010, 1000V Cat.III Power Source 9V Alkaline battery Battery Life Approx. 150 hours of continuous use Low Battery Indication Blinking green LED Electronic Overload Indication Red LED MECHANICAL Cable Length 6.5 ft (2m) sensor to module Water and Dustproof Sensor IP45; Module IP40 Dimensions Sensor: 24", 36", 48" or 60" (609, 914, 1219 or 1524mm); Module: 4.9 x 2.5 x 1.1" (124.5 x 64 x 28mm) Weight (with battery) 24": 11.84 oz (0.33kg); 36": 14.24 x (0.4kg); 48": 15.2 oz (0.l43kg); 60": 1.13 lb (0.51kg) Maximum Conductor Size 24": 7.64" (190mm); 36": 11.46" (290mm); 48": 15.28" (390mm); 60": 19.10" (490mm) Output Termination 3 /4" spaced banana jacks, optional banana plug to BNC adapter available, 6.5 ft (2m) lead from sensor to module ENVIRONMENTAL Operating Temperature 14 to 131 F (-10 to 55 C) Storage Temperature -40 to 158 F (-40 to 70 C) Operating Relative 50 to 86 F (10 to 30 C) 85 to ±5% RH (non-condensing) Humidity 104 to 122 F (40 to 50 C) 45 to ±5% RH (non-condensing) SAFETY Rating EN 61010, 1000V Cat. III, Pollution Degree: 2 Double Insulation CE Mark *Intentionally limited for optimum performance CONSTRUCTION Common: black banana plug ( ) Positive: red Power ON indicator banana plug (+) (green LED) Range selection switch OVERLOAD indicator (red LED) Electronic module Flexible sensor Model 1000-24-2-1 Lead, 6.5 ft (2m) Connector/ latch Technical Assistance (800) 343-1391 www.aemc.com 3

LONGLIFE AMPFLEX Flexible Current Probes Model LGLF 1000-24-1-1 FEATURES Single or dual range models to measure up to 3000A TRMS measurements when connected to a TRMS instrument No core saturation or damage if overloaded Waterproof sensor 9V Alkaline battery, provides typical 2000 hour continuous operation Shape Memory for pre-shaping of sensor before use (no drooping) Insensitive to DC, measures only AC component on DC + AC Excellent linearity EN 61010, 1000V Cat. III (sensor); EN 61010, 600V Cat. III (module) APPLICATIONS Load analysis Data logging Power quality monitoring General purpose current monitoring The LongLife AmpFlex is an AC current probe composed of a flexible sensor and an electronic module. The flexible sensor permits measurements on conductors where standard clamp-on probes could not be used. In particular, it can be installed in tight spaces, in breaker panels, around cable bundles, around wide or large bus bars, or even wrapped around irregular shapes. The Shape Memory feature enables the user to pre-shape the sensor before inserting it between or around conductors. This feature facilitates closing, enhances user safety and alleviates the drooping effect associated with other flexible sensors that require reaching around the conductor to complete the loop. The LongLife AmpFlex is lightweight and does not use magnetic cores like standard transformers. The transformation principle is based on an air core. It presents virtually no load to the system under test, has a low phase shift and excellent frequency response, and cannot be damaged by overloads. The sensor assembly is waterproof and insulated for 1000V Cat. III. The LongLife AmpFlex has a millivolt output proportional to the current measured for direct readings on data loggers, DMMs and oscilloscopes. TRMS measurements are taken when connected to a TRMS meter. The LongLife AmpFlex is insensitive to DC currents; only the AC component of the measured signal is measured. Model LGLF 1000-24-1-1 measuring on one phase of the primary side of an in-plant three-phase transformer. 4 www.aemc.com Technical Assistance (800) 343-1391

SPECIFICATIONS MODELS LGLF 1000-24-1-1 LGLF 1000-24-2-1 LGLF 3000-36-1-1 LGLF 3000-36-2-1 ELECTRICAL Measurement Range 5 to 1000A 5 to 100A: 50 to 1000A 5 to 3000A 5 to 300A: 50 to 3000A Output Signal 10mV/A & 0.333mV/A 3.33mV/A & 0.333mV/A Accuracy* 1% of Reading + 200mA 1% of Reading + 200mA 1% of Reading + 200mA 1% of Reading + 200mA from 50 to 1000A from 50 to 3000A 1% of Reading + 500mA 1% of Reading + 500mA 1% of Reading + 500mA 1% of Reading + 500mA from 5 to 50A from 5 to 50A from 5 to 50A from 5 to 50A Crest Factor 3 3 3 3 Phase Shift <1 @ 50 to 60Hz <1 @ 50 to 60Hz <1 @ 50 to 60Hz <1 @ 50 to 60Hz Current Range 1000A 100A: 1000A 3000A 300A: 3000A Working Voltage 1000Vrms max (Cat. III) 1000Vrms max (Cat. III) 1000Vrms max (Cat. III) 1000Vrms max (Cat. III) Common Mode Voltage 600Vrms 600Vrms 600Vrms 600Vrms Residual Noise 500mArms 500mArms 500mArms 500mArms Power Source 9V Alkaline battery Battery Life 2000 hours typical; 4000 hours max Low Battery Indication Blinking red LED MECHANICAL Cable Length 6.5 ft (2m) sensor to module Water and Dustproof Sensor: IP45; Module: IP65 Dimensions Sensor: 24" or 36" (609 or 914mm); Module: 1.56 x 2.5 x 4.5" (40 x 64 x 114mm) Weight (with battery) 24": 14.9 oz (0.42kg); 36": 1.5 lbs (0.56kg) Maximum Conductor Size 24": Ø 7.64" (190mm); 36": Ø 11.46" (290mm) Output Termination 14" (350mm) double insulated cable with 4mm banana plug ENVIRONMENTAL Operating Temperature 14 to 131 F (-10 to 55 C) Storage Temperature -4 to 158 F (-20 to 70 C) Operating Relative 50 to 86 F (10 to 30 C) 85 to ±5% RH (non-condensing) Humidity 104 to 122 F (40 to 50 C) 45 to ±5% RH (non-condensing) SAFETY Rating EN 61010, 1000V Cat. III, Pollution Degree: 2 Double Insulation CE Mark *Reference Conditions: 73.4 F (23 C) ±3 K, 20 to 70% RH, 50/60Hz, no external AC magnetic field, DC magnetic 40A/m (earth field), supply: 8V + 10%. 1MΩ Load. CONSTRUCTION Lead, 6.5 ft (2m) Power ON indicator (Green LED) Low battery indicator (Red LED) Range selection push button Connector/latch Banana plugs: Common: black ( ) Positive: red (+) Electronic module Lead, 14" (0.35m) Flexible sensor Model LGLF 1000-24-1-1 Technical Assistance (800) 343-1391 www.aemc.com 5

FLEXPROBE Flexible Current Probes Model 24-3001 The FlexProbe Models 24-3001 and 24-3002 are low cost AC current measurement probes designed to plug into DMMs, oscilloscopes and power monitors. The Model 24-3001 is composed of a flexible sensor and an electronic module with a 14" double insulated cable, while the Model 24-3002 has a flexible sensor and an electronic module with 4mm safety banana plugs with 3/4" spacing. The flexible sensors are designed to fit around large or small conductors and are capable of getting into tight or difficult places. They are ideal for measuring AC current in a group of conductors. The Shape Memory feature enables the user to pre-shape the sensor before inserting it between or around conductors. This feature facilitates closing, enhances user safety and alleviates the drooping effect typically associated with flexible sensors, which can be a safety hazard. FEATURES 24" flexible sensor fits around conductors up to 7.6" in diameter Dual measurement ranges of 300A and 3000AAC Read amperage directly on DMM display Millivolt output directly proportional to the AC current measured Output is 10mV/A on 300A range and on 3000A range Accuracy of 1% of Reading ± 500mA 9V Alkaline battery, provides typical 300 hour continuous operation Dual banana plug termination for direct input into DMMs (Model 24-3001) Electronic module with 4mm safety banana plugs with 3 /4" spacing (Model 24-3002) Flashing LED low battery indicator EN 61010, 1000V Cat. III, Pollution Degree: 2 APPLICATIONS Motor testing and troubleshooting Load monitoring HVAC troubleshooting Power analysis Transformer testing Substation testing The FlexProbe is lightweight and does not use magnetic cores like standard transformers. The transformation principle is based on an air core. It presents virtually no load to the system under test, has a low phase shift and excellent frequency response, and cannot be damaged by overloads. The sensor assembly is waterproof and insulated for 1000V Cat. III. The FlexProbe has a millivolt output proportional to the current measured for direct readings on DMMs, data loggers, oscilloscopes and power or harmonic meters. TRMS measurements are taken when connected to a TRMS meter. The FlexProbe is insensitive to DC currents and only the AC component of the measured signal is measured. FlexProbe conveniently plugs into the standard DMM voltage input for direct read-out of the measured current. 6 www.aemc.com Technical Assistance (800) 343-1391

SPECIFICATIONS MODELS 24-3001 24-3002 ELECTRICAL Current Range 300/3000AAC 300/3000AAC Measurement Range 5 to 3000Arms 5 to 3000Arms Output Signal mv output (4000mV peak max) mv output (4000mV peak max) Three Position Slide 10mV/A 5 to 300Arms 5 to 300Arms Switch 50 to 3000Arms 50 to 3000Arms ON/OFF AC Current Accuracy 1% of Reading ± 500mA 1% of Reading ± 500mA Crest Factor 4.5 4.5 Phase Shift* <0.7 @ 50 or 60Hz <0.7 @ 50 or 60Hz Frequency Range 40 to 5kHz 40 to 5kHz Working Voltage 1000Vrms max (Cat. III) 1000Vrms max (Cat. III) Common Mode Voltage 600Vrms max 600Vrms max Residual Noise 200mArms 200mArms Power Source 9V Alkaline battery (NEDA 1604A, IEC 6LR61) Battery Life 150 hours typical (continuous use); 300 hours with Lithium battery Good Battery Indication Green LED Electric Overload Indication Red LED MECHANICAL Cable Length 6.5 ft (2m) Water and Dustproof Sensor: IP45; Module: IP40 Dimensions Sensor: 24"; Module: 4.9 x 2.5 x 1.1" (124 x 64 x 28mm) Weight (with battery) 1.1 lb (0.5kg) Maximum Conductor Size 7.64" (190mm) Output Termination Double insulated 14" (350mm) lead with safety banana plugs Two 4mm safety banana plugs; standard 3 /4" (19mm) spacing ENVIRONMENTAL Operating Temperature 14 to 131 F (-10 to 55 C) Storage Temperature 40 to 70 F (-40 to 158 C) Operating Relative 50 to 86 F (10 to 30 C) 85 to ±5% RH (non-condensing) Humidity 104 to 122 F (40 to 50 C) 45 to ±5% RH (non-condensing) SAFETY Rating EN 61010, 1000V Cat. III, Pollution Degree: 2 Double Insulation CE Mark *Reference Conditions: 73.4 (23 C) ± 3K, 20 to 70% RH, 50Hz, one minute warm-up, battery at 9V ± 0.1V, external magnetic field <40A/m, no DC component, no external current carrying conductor, 10MΩ load, conductor center CONSTRUCTION Power Lead, 14" (0.35mm) ON indicator (green LED) Range selection switch OVERLOAD indicator (red LED) Electronic module Model 24-3001 Leads: Double/reinforced 14" (350mm) lead with safety 4mm banana plug Model 24-3002 Shrouded Banana Plugs: Two 4mm safety banana plugs; standard 3 /4" (19mm) spacing Lead, 6.5 ft (2m) Flexible sensor Model 24-3001 Connector/latch Technical Assistance (800) 343-1391 www.aemc.com 7

ORDERING INFORMATION AmpFlex Sensor Length/Diameter Current Range Output Signal 24"/8" 36"/11" 48"/15" 60"/19" (610mm/190mm) (910mm/290mm) (1220mm/390mm) (1520mm/490mm) 30A 100mV/A 200A 300A 10mV/A 300A 30/300A 100/10mV/A 500A 50/500A 10/mV/A 1000A 100/1000A 10/ 3000A 300/3000A 3-3/0.33mV/A* 300/3000A 10/ 6000A 0. 600/6000A 1/0. 10,000A 0. 1000/10,000A 1/0. 30,000A 0. 3000/30,000A 1/0. Cat. #2112.14 Model 30-24-1-100 Cat. #2112.20 Model 200-24-1-1 Cat. #2112.29 Model 300-24-1-10 Cat. #2112.24 Model 300-24-1-1 Cat. #2112.88 Model 300-24-2-10 Cat. #2112.34 Model 500-24-1-1 Cat. #2112.93 Model 500-24-2-1 Cat. #2112.39 Cat. #2112.41 Cat. #2112.42 Model 1000-24-1-1 Model 1000-36-1-1 Model 1000-48-1-1 Cat. #2112.98 Cat. #2113.00 Cat. #2113.01 Model 1000-24-2-1 Model 1000-36-2-1 Model 1000-48-2-1 Cat. #2112.46 Cat. #2112.48 Cat. #2112.49 Model 3000-24-1-1 Model 3000-36-1-1 Model 3000-48-1-1 Cat. #2114.87 Cat. #2114.88 Model 3000-24-2-0.3 Model 3000-36-2-0.3 Cat. #2113.05 Cat. #2112.00 Cat. #2112.01 Model 3000-24-2-1 Model 3000-36-2-1 Model 3000-48-2-1 Cat. #2112.62 Cat. #2112.64 Cat. #2112.65 Cat. #2112.66 Model 6000-24-1-0.1 Model 6000-36-1-0.1 Model 6000-48-1-0.1 Model 6000-60-1-0.1 Cat. #2113.19 Cat. #2113.21 Cat. #2113.22 Cat. #2113.23 Model 6000-24-2-0.1 Model 6000-36-2-0.1 Model 6000-48-2-0.1 Model 6000-60-2-0.1 Cat. #2112.70 Cat. #2112.72 Cat. #2112.73 Cat. #2112.74 Model 10000-24-1-0.1 Model 10000-36-1-0.1 Model 10000-48-1-0.1 Model 10000-60-1-0.1 Cat. #2113.27 Cat. #2112.02 Cat. #2112.03 Cat. #2113.29 Model 10000-24-2-0.1 Model 10000-36-2-0.1 Model 10000-48-2-0.1 Model 10000-60-2-0.1 Cat. #2112.78 Cat. #2112.80 Cat. #2112.81 Cat. #2112.82 Model 30000-24-1-0.1 Model 30000-36-1-0.1 Model 30000-48-1-0.1 Model 30000-60-1-0.1 Cat. #2113.33 Cat. #2113.35 Cat. #2113.36 Cat. #2113.37 Model 30000-24-2-0.1 Model 30000-36-2-0.1 Model 30000-48-2-0.1 Model 30000-60-2-0.1 LongLife AmpFlex Model LGLF 1000-24-1-1 (1000A, 24", 0.)............................................ Cat. #2120.66 LongLife AmpFlex Model LGLF 1000-24-2-1 (100/1000A, 24", 10mV/).................................... Cat. #2120.67 LongLife AmpFlex Model LGLF 1000-36-1-1 (3000A, 36", 0.3mV/A)............................................ Cat. #2120.68 LongLife AmpFlex Model LGLF 1000-36-2-1 (300/3000A, 36", 0.3mV/3.3mV/A).................................. Cat. #2120.69 FlexProbe Model 24-3001 (300/3000AAC, 24", 10mV/A/, with lead)........................................ Cat. #2120.81 FlexProbe Model 24-3002 (300/3000AAC, 24", 10mV/A/)................................................. Cat. #2120.82 Accessories (Optional) Banana (female) BNC (male) Adapter (XM-BB)......................................................... Cat. #2118.46 *These two models are specifically designed to be used with recorders or power analyzers with a Voltage AC input. A scale factor may need to be entered into the recorder to display the exact value. Banana (female) BNC (male) Adapter (XM-BB) Catalog #2118.46 (optional) Call the AEMC Instruments Technical Assistance Hotline for immediate consultation with an applications engineer: (800) 343-1391 Chauvin Arnoux, Inc. d.b.a AEMC Instruments 200 Foxborough Blvd. Foxborough, MA 02035 USA (800) 343-1391 (508) 698-2115 Fax (508) 698-2118 Visit our website at www.aemc.com 950.BR-FLEX-CT 12/05 Rev. 02 Printed in the USA