8248AU. 4-Ch Isolated Amplifier with Optional Bridge Conditioning FEATURES TYPICAL APPLICATIONS

Similar documents
V or 64-channel Scanning ADC. APPLICATIONS. The V213 is a single-width, C-size, register-based, VXIbus

TECHNICAL MANUAL. SERIES AP5103 DIN-Rail DC Strain Gage Conditioner ISO 9001/AS9100

QUAD-CHANNEL CONDITIONER BALANCED CURRENT EXCITATION ±10 V Common Mode; 255 or 510 Cutoff Frequencies

Features EX1629. High-performance Remote Strain Gage Measurement Unit. Overview. 48 programmable channels in a single unit

Signal Conditioning Amplifier

28104A. QUAD-CHANNEL WIDEBAND BRIDGE CONDITIONER Constant Voltage Excitation; 700 khz Bandwidth PRECISION 28104A APPLICATIONS

Product Description. SIGnal Workbench. Programmable Signal Conditioning System

Isolated Linearized 4-Wire RTD Input 5B35 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

EX FEATURES. Stand-alone 48-channel unit with built-in Ethernet controller. Built-in bridge completion and Excitation

SCXI 8-Channel Isolated Analog Input Modules

28454A. QUAD-CHANNEL CONDITIONER BALANCED CURRENT EXCITATION Constant Current Excitation; 700 khz Bandwidth PRECISION 28454A APPLICATIONS

Isolated, Linearized Thermocouple Input 5B47 FEATURES APPLICATIONS PRODUCT OVERVIEW

Isolated, Frequency Input 5B45 / 5B46 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Precision Octal-Channel Bridge Conditioner with Constant Voltage Excitation

Precision Quad-Channel Transducer Conditioner with Voltage and Current Excitation

imc CANSAS-L-HCI8. High isolated module for the capture of temperature, voltage, current (20 ma) and resistance

ASK Cards. Features Analog signal isolation Digital signal isolation. Applications

DC MHZ PXI Differential Instrumentation Amplifier

Model SR554 Transformer Preamplifier

imc C-SERIES: CS-1016-N, CL-1032-N

Isolated High Level Voltage Output 7B22 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

MODEL: M2VF MODEL: M2VF [1][2] [3][4]

DIN Thermocouple Conditioner MODEL 5M14(V)

QUAD PROGRAMMABLE FILTER/AMPLIFIERS For the and Signal Conditioning Systems

Strain Gauge Measurement A Tutorial

LV3-8 for imc CRONOS-PL/-SL/compact

Transducer for Measurement Bridges SCM90, SIGS15

Model A. DIN Rail Strain Gage Conditioner. Installation and Operating Manual

Module Input type Ranges TEDS Filters (LP = lowpass, HP = highpass) Piezoresistive bridge ±0.5 to mv/ma 1 ma exc

Kistler LabAmp for DynoWare

VMIVME Channel 16-bit Arbitrary Waveform Generator Board with Autocalibration

Isolated, Linearized Thermocouple Input 7B47 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated, Thermocouple Input 7B37 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

EX1000 Series EX1000A EX1000A-TC EX1016A EX1032A EX1048A EX10SC EX1000A-TCDC RELIABLE DATA FIRST TIME EVERY TIME.

Tel: (949) Fax: (949) IAA100 Product Manual

Precision Quad-Channel Wideband Transducer Conditioner with Voltage and Current Excitation

DBK45. 4-Channel SSH and Low-Pass Filter Card. Overview

Isolated, Linearized RTD Input 7B34 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Precision 28918A 8-Channel CVLD/IEPE Conditioner

Signal Conditioning Amplifier

DP2000 ORDERING GUIDE To Order MODEL NO.

Signal Conditioning Systems

Kistler LabAmp. Electronics & Software. Charge Amplifier and Data Acquisition Unit for Dynamic Measurements. Type 5165A...

Advanced Test Equipment Rentals ATEC (2832)

High Speed FET-Input INSTRUMENTATION AMPLIFIER

ADAM Isolated DC Input/Output Signal Conditioning Module. User s Manual

DIFFERENTIAL CURRENT GENERATOR «POCDIF» (AC/DC - 32A - 50V - 12 ranges)

DRG-SC Series Signal Conditioners

2014 Short Form Test and Measurement Catalog

TRANSDUCER INTERFACE APPLICATIONS

ARD154. DIN rail mountable amplifier for strain gage sensors. User s guide. User s guide ARD CONNECTING 4-WIRE SENSORS

Analog Signal Conditioning Accessories

Models 900CT & 900BT. Tunable Active Single Channel Certified Filter Instrument

CSG110 Strain Gauge Universal Amplifier

Correlation of Voltage and Temperature Measurement

SB.5.1 MODEL STRAIN GAGE CONDITIONER INSTRUCTION MANUAL. Instrument Series

USB-TEMP and TC Series USB-Based Temperature Measurement Devices

EX CHANNEL ISOLATED THERMOCOUPLE AND VOLTAGE MEASUREMENT INSTRUMENT

Analog Isolation Amplifiers

Four-Channel Transient Strain Signal Conditioning Plug-on VT1511A

MODEL: M2XPA3. [2] EXCITATION 2: 4 V DC / 20 ma 3: 8 V DC / 20 ma 4: 12 V DC / 20 ma Configurator software is used to change the excitation value.

Analog Isolation Amplifiers

MODEL AT-10 ANALOG TRANSMITTER

MECE 3320 Measurements & Instrumentation. Data Acquisition

DMS Insert Module MSR 282

Economical Digital Indicators For Process and Electrical Measurement

RX1032 PRECISION TEMPERATURE MEASUREMENTS FOR RUGGED ENVIRONMENTS FEATURES. 32-Channel Thermocouple Measurement System

Isolated DIN Rail Mount Loop-Powered 2-Wire Signal Conditioners. DRLP Series

Zero Drift, Unidirectional Current Shunt Monitor AD8219

Modular Smart Interfaces

Octal Sample-and-Hold with Multiplexed Input SMP18

Ethernet-Based Temperature, Voltage and Strain Measurement Modules

DC Current Transducers CT-200 CT-300 CT-400 User s Manual All Rights Reserved CAEN ELS d.o.o. Rev. 1.0 November 2014

Model 176 and 178 DC Amplifiers

Signal Conditioning Fundamentals for PC-Based Data Acquisition Systems

LAUREL ELECTRONICS, INC.

D100L Series. 100 Hz to 100 khz Low Noise Fixed Frequency. 4- and 8- Pole Low-Pass Filters

imc C-SERIES: CS-3008-N, CL-3016-N

SENSOTEC, INC Arlingate Lane Columbus, Ohio Phone (614) Facsimile (614) Toll Free Free (800)

SC-4/M User manual 4-channel measuring amplifier

Installation and Operating Manual

Model 140 Inline Amplifier

High Common-Mode Voltage, Programmable Gain Difference Amplifier AD628

PRECISION CURRENT TRANSDUCERS. DC Current Transducers CT-100 CT-150. User s Manual. All Rights Reserved CAEN ELS d.o.o. Rev. 1.

Making Basic Strain Measurements

EPAD2/CPAD2/CPAD3 Modules. Modules with CAN or RS-485 Interface

Introduction ISOLATED SIGNAL CONDITIONING can significantly increase

Micropower, Single-Supply, Rail-to-Rail, Precision Instrumentation Amplifiers MAX4194 MAX4197

Hardware Adjustment 13 Trimpots 13 CAL/NORM, CAL1/RUN, and CAL2/RUN Switches 13

DSSIU-6-1U. Dedicated 6-channel system interface unit for ultra-stable, high precision fluxgate technology DS series current transducers.

12/4/ X3 Bridge Amplifier. Resistive bridge amplifier with integrated excitation and power conditioning. Logos Electromechanical

Operation. Displayed channel. Measuring range. Status indication/ remote control Key lock Measuring mode/ time constant. Scale.

MODEL: 20VS2-02. Hybrid IC Isolation Amplifiers 20 Series

120 khz Bandwidth, Low Distortion, Isolation Amplifier AD215

DS2000ICLA. Specification highlights Symbol Unit Min Typ Max. Features. Applications: 1 ppm linearity. MPS for particles accelerators.

VMIVME-3122 Specifications

SC200 Series. Signal Conditioner MNX10020, REV H 10/17/ Connection Technology Center, Inc Rae Boulevard Victor, NY (585)

Sensor Interfacing and Operational Amplifiers Lab 3

MEP 382: Design of Applied Measurement Systems Lecture 5: Signal Conditioning

EPAD2/CPAD2/CPAD3 Modules. Modules with CAN or RS-485 Interface

Transcription:

8248AU The 8248AU is a single-width, 4-Ch Isolated Amplifier with Optional Bridge Conditioning 6U, CompactPCI/PXI module with 4 channels of Isolated Signal Conditioning feeding two buffered outputs. This single-module signal conditioner solution can be coupled with any data acquisition system, including analogto-digital converter products from KineticSystems. Optional configurations support complete bridge signal conditioning. The 8248AU is a single-width, 6U, CompactPCI/PXI module with 4 channels of Isolated Signal Conditioning feeding two buffered outputs. TYPICAL APPLICATIONS Automotive test cells Industrial monitoring and control Automatic Test Equipment (ATE) FEATURES Isolated inputs and bridge excitation 300 Volts common mode Filtered or wideband analog outputs gain and filter per channel Bridge option available 6 pole, low pass filter with programmable cutoff from 20Hz to 50kHz Bridge Completion for 1, 2, or 4 active arms Voltage and current excitation shunt calibration and excitation per channel bridge balance

GENERAL DESCRIPTION The 8248AU is a single-width, 6U, CompactPCI/PXI module with 4 channels of Isolated Signal Conditioning feeding two buffered outputs. This singlemodule signal conditioner solution can be coupled with any data acquisition system, including analog-to-digital converter products from KineticSystems. Optional configurations support complete bridge signal conditioning. Two buffered outputs are provided with the 8248AU. One buffered output is a pre-filter output that is at the sensor input ground potential. The second buffered output is an isolated version of the input signal at chassis potential. This second output can be selected to be either pre-filter or post-filter. The secondary buffered output is isolated through the use of optical isolation. The input signal is digitized at a rate of 250 khz by an analog-to-digital converter (ADC). An ADC is present for each channel to eliminate the multiplexing effects of a single ADC implementation. The converted data is then fed into an optical isolator for re-generation by a digital-to-analog converter. Each channel of the 8248AU isolated amplifier provides isolated inputs with operation up to ±300V common mode. Software selectable filter cutoff frequencies are programmed on a per-channel basis and include 20Hz, 200Hz, 500Hz, 1kHz, 2kHz, 5kHz, 25kHz, 50kHz and filter bypass (wide-band). gain settings of 1, 2, 5, 10, 20, 50,100, 200, 500, 1000, 2000, 5000 and 10000 are provided. The 8248AU bridge option supports 10 wire transducer connections. The bridge signal conditioning option adds shunt calibration, bridge balance, and excitation selection on a per channel basis. Each channel input is completely isolated from the other channel inputs, including excitation supplies, through extensive use of DC/DC converters. On-board bridge completion handles 120Ω, 350Ω or 1000Ω bridges in ¼, ½ and full configurations. The per-channel excitation sources are programmable from 0 to 10 volts in 4096 steps and contain alarm circuitry to monitor excitation supply health. Each channel can be programmed for either voltage or current excitation. Bridge offsets may be nulled using on-board 12-bit DACs to maximize the dynamic range of the instrument. BASIC CIRCUIT OPERATION

Number of Channels Item 4 Isolated differential inputs Specifications Inputs Input Impedance Input Protection Input Coupling Analog Differential Input Range Common-Mode Range Analog Outputs Range Gain Filter Gain Selections Filter Type Filter Cutoff Frequencies Excitation * Excitation Type Excitation Sense Excitation Voltages Excitation Current Line Regulation Load Regulation Temperature Coefficient Bridge Completion * Bridge Configuration Completion Resistance Shunt Calibration * Shunt Resistor Location Bridge Balance * Bridge Offset Null Analog Input Connector Type Analog Output Connector Type Transfer Characteristics Gain Non-Linearity DC Accuracy, % of Full Scale Range Gain=1 Gain=2 Gain=5 Gain=10 Gain=20 Gain=50 Gain=100 Gain=200 Gain=500 Gain=1000 Gain=2000 Gain=5000 Gain=10000 10 MΩ minimum, > 100 MΩ typical (DC-coupled) ± 32 V differential, ±300 V common-mode DC or AC ±10.24 Volts 300 Volts peak AC or DC ±10 Volts peak @ 20mA max (isolated and non-isolated outputs) 1, 2, 5, 10, 20, 50, 100, 200, 500, 1000, 2000, 5000 and 10000 6 pole, Bessel or Butterworth (as ordering option), on a per channel basis 20Hz, 200Hz, 500Hz, 1kHz, 2kHz, 5kHz, 25kHz, 50kHz and filter bypass (wideband) Independent isolated excitation source for each channel. Voltage or Current per channel for local or remote. per channel for 0 to 10 volts in 4096 steps, 50 ma drive. per channel for 0 to 50 ma in 4096 steps, 10 volt. 0.003 %/V (0.005% for current excitation regulation) 0.001 V/mA 2 ppm/ C (2.8 ppm/ C for current excitation) ¼, ½ and Full Bridge 120Ω, 350Ω or 1000Ω Internal or External (User Selected and Supplied) Utilizing 12 bit DAC, range set by resistor value 4-15 contact DSUB connectors 1-9 contact DSUB connector 0.005% FSR for gain settings <= 1000 0.006% FSR for gain setting = 2000 0.025% FSR for gain setting = 5000 0.035% FSR for gain setting = 10000 After calibration utilizing DAS 0.005% 0.005% 0.006% 0.006% 0.011% 0.0125% 0.015% 0.025% 0.025% 0.030% 0.060% 0.150% 0.300%

Gain Stability All Gains Offset Stability, RTI Common Mode Rejection Ratio Noise, RTI Channel to Channel Crosstalk Power Requirements +5 V +3.3V +12 V -12 V Environmental and Mechanical Temperature range Operational Storage Relative humidity Cooling requirements Dimensions Front-panel potential Item *Indicates specification supported when bridge option installed Specifications Output 2 (chassis potential) ± 40 ppm/ C maximum ± 2mV/ C maximum @Gain=1000-105 db minimum DC to 60 Hz for gain>=10; 80dB minimum at any gain DC to 60Hz < 5mV rms @ Gain=1000, External ADC Rate = 100 khz < 1 mv rms @ Gain=1000, External ADC Rate = 100kHz 200 Hz filter -110 db minimum between adjacent channels DC to 2kHz 3250 ma 325 ma 400 ma 400 ma 0 C to +50 C -25 C to +75 C 0 to 90%, non-condensing to 40 C 10 CFM 233.35 mm x 160 mm (6U CompactPCI/PXI module) Chassis ground

SOFTWARE The 8248AU comes with a Plug and Play driver for configuring and using the device and application examples to illustrate its basic functionality. ORDERING INFORMATION MODEL 8248AU-xyz1 DESCRIPTION 4 Channel Isolated CompactPCI/PXI Amplifier with Optional Bridge Conditioner X: Filter Option B = 6-pole Bessel K = 6-pole Butterworth Y: Bridge Option A = Not Installed B = Installed Z: Completion Resistors (Select Option A when Bridge Option not installed) A = None B = 120 Ω C = 350 Ω D = 1000 Ω RELATED PRODUCTS MODEL 5856-Nxyz 5938-Z1A 5938-Z2A 5856-Lxyz Cable 59XX-wxyz DIN-15S-01 V755-ZA11 DESCRIPTION Cable: 15-contact D to 15-contact DSUB 15-contact DSUB Mating Connecter 15-contact DSUB Solder-Cup Connector 9-contact DSUB to Unterminated, Shielded Twisted Pair 9-contact DSUB Mating Connector DIN Rail Mount Termination Panel 15-position Front Panel Mount Screw Termination Panel Updated June 19, 2014 Specifications contained within this data sheet are subject to change without notice. 900 N. State St. Lockport, IL 60441-2200 Toll-Free (US and Canada): phone 1-800-DATA NOW 1-800-328-2669 Direct: phone +1-815-838-0005 fax +1-815-838-4424 Email: mkt-info@dynamicsignals.com To find your local sales representative or distributor or to learn more about KineticSystems products visit: KineticSystems is a product brand of DynamicSignals LLC, and ISO 9001:2008 Certified Company Copyright 2014 DynamicSignals, LLC. All rights reserved.