PD132 Loop Detector Specification

Similar documents
Short form User Manual

AGP-0230 USER MANUAL AMANO

Single Channel Loop Detector

Single Channel Loop Detector

Single Channel Loop Detector

Single Channel Loop Detector

FLUX 11 Pocket installation manual SENSITIVE INDUCTIVE LOOP DECTOR

Single Channel Loop Detector

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

Single Channel Loop Vehicle detector User Manual

USER MANUAL ULD 910. October 2003 Revision: 03. Single Channel Vehicle Detector ULD 910. Part Number: MIC

SMARTSCAN INFORMATION

Dual Channel Vehicle Detector ULD 920 USER MANUAL Part Number: MIC ULD 920

Dual Channel Traffic/Parking Detector User Guide

BEA s digital inductive single loop solution

DSP-20 Dual Channel Vehicle Detector With Directional Logic

USERS GUIDE MATRIX2 DIGITAL INDUCTIVE LOOP SENSORS

USERS GUIDE MATRIX P/N SINGLE DIGITAL INDUCTIVE LOOP SENSOR

TECHNICAL MANUAL FOR LOOP DETECTORS WITH POWERFAIL MEMORY Article Codes: RDET1CM & RDET2CM

MD12-2 Metal Loop Detector

DSP-21 Directional Counting Detector

PD230 Enhanced Vehicle Detector USER MANUAL

FG2 TWO-CHANNEL DETECTOR

RME1-RME1BT INSTRUCCIONES DE INSTALACION INSTALLATIEVOORSCHRIFTEN INSTRUCTIONS D INSTALLATION ИНСТРУКЦИИ ПО УСТАНОВКЕ ISTRUZIONI DI INSTALLAZIONE

SPECIAL SPECIFICATION 1257 Digital Card Rack Non-Invasive Micro Loop Detector Assembly (8 Slot Rack)

DSP-10 Vehicle Detector

FACTORY AUTOMATION. MANUAL LC10-* Laying loops for Loop detector LC10-1 and LC10-2

Underground Loops and Loop Detectors. DoorKing Plug-In Loop Detectors and Loop Accessories Single Channel CH1

Connection and installation manual. Induction loop detector ISD 4, ISD 4/2

601/602 Series Inductive Loop Detector

SPECIAL SPECIFICATION 6004 Digital Card Rack Inductive Loop Detector Assembly

MODEL T-110 SERIES OPERATION MANUAL

Loops /29/2018 8:00 AM. Ben Luke

ULT-MVP O P E R A T I N G I N S T R U C T I O N S ULTRALOOP V E HI C L E L O O P DETECTOR Johnston Parkway, Cleveland, Ohio 44128

Loop Installation. Manual

Operating Instructions

SOUTH DUBLIN COUNTY COUNCIL Traffic Management Centre Roads (Traffic and Transportation) Department

LMD622 and LMD624 Series

ULT-DIN O P E R A T I N G I N S T R U C T I O N S ULTRALOOP V E HI C L E L O O P DETECTOR Johnston Parkway, Cleveland, Ohio 44128

MATRIX INDUCTIVE LOOP CONTROL BOX

ITS specification Inductive loops and feeder cables (ITS-03-01)

SECTION 5 TRANSFORMERS

Loop Installation. Manual.

Inductive Loop Detector

Operating Instructions

MODEL L-1200 SERIES OPERATION MANUAL

Driveway Alarm INSTALLATION MANUAL

With Audible Detect Signal

Operating Instructions MAGSTOP Traffic Barrier MIB 20/30/40 MLC Controller Unit

Diamond Knowledge Base. Inductive Loop Guide. Introduction

Operations Manual. Model NT11 & NT11-E. June 18 th 2002

INSTRUCTIONS: 1. Record the transmittal letter number, date, and subject on the transmittal record sheet located in the front of the manual.

WPT-1000 Wireless Probe Transmitter. Owner s Manual

SUBJECT: Standard Plate 9102 Turf Establishment Areas At Pipe Culvert Ends

IRIS \ IRIS-I QUICK SET-UP GUIDE STEP 1 INSTALL

SUBJECT: Standard Plate Turf Establishment Areas (at Pipe Culvert Ends)

Manhole or Catch Basin Type A & B Cone Sections Precast - Design F Manhole or Catch Basin Cover (Reducer Cone Section Precast) Design D

Standard Plate 7036 is discontinued. It is replaced by Standard Plan Pedestrian Curb Ramp Details.

MODEL C-1000 SERIES OPERATION MANUAL

Double Channel Loop Detector

4-Channel-Loop-Detector Euro-card plug-in 19"

Single Channel Loop Detector

Wisconsin Contractors Institute Continuing Education

RECOGNITION OF VEHICLES BY THE INDUCTION LOOP DETECTOR

2. Remove from the Standard Plate manual: Standard Plate Index, Sheets 1-4 of 4, Numerical Index of Standard Plates (August 31, 2012)

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

TELESCOPIC GATE MANUFACTURING AND INSTALLATION MANUAL.

Telemetrie-Messtechnik Schnorrenberg

Current Standard Plates including Transmittal Letters are available on the web at:

SHADOWBOX INSTALLATION FOR: Standard 6 H x 8 W Shadowbox Fence 5 x 5 Routed Posts Dog Ear or Straight-Edge Pickets 1.75 x 3.5 Rail

Train Detection Handbook

Installation requirements

INDEX. Accessories and Components System Unit and Joystick Assembly and Charging the Battery Using with LED System...

Twisted Wire in the Loop Itself Test

Current Probes. User Manual

Current transducer FHS 40-P/SP600

Application Note # 5438

eguard EG2233, EG3333, EG3355, EG3388 & EG8406: Installation and Set-up Procedures Tx 2200 and Rx 4200 Boards

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

Installation Manual. UL 325 Compliant. For Pre-2016 Convenience Open Operators ONLY

Kentaur Turnstiles Full-height gates

Four Channel Inductive Loop Detector

Installation Guide. Capped Cellular PVC Fencing. Table of Contents. Storage and Handling Tools Needed Fence Layout and Locating Posts

Kentaur Turnstiles Kentaur Full-Height Gates

SDCS-03 DISTRIBUTION NETWORK GROUNDING CONSTRUCTION STANDARD (PART-I) UNDERGROUND NETWORK GROUNDING. Rev. 01

Golden Mask Deep Hunter LE

SUBJECT: Standard Plates 4132, 4155, Drainage Structures and Castings Info

Com-Trol ADV-6000 Trouble Shooting Guide Click on red text to go to that page in guide

PRIVACY INSTALLATION FOR: Standard 6 H x 8 W Privacy Fence 4 x 4 Post Sleeve & Brackets Dog Ear or Straight-Edge Pickets 1.75 x 3.

USER MANUAL APG DYNAMIC PROCESSORS MATRIX ARRAY SYSTEMS 4000SP 6000SP 9000SP

Status Date Prepared Reviewed Endorsed Approved

Dakota Alert. WPT-3000 Wireless Probe Transmitter. Owner s Manual

Aqua-Gen 3BR INSTRUCTIONS

SDCS-03 DISTRIBUTION NETWORK GROUNDING CONSTRUCTION STANDARD (PART-II) OVERHEAD NETWORK GROUNDING. Rev. 01

Safety Warnings Features Specifications Instrument Layout Operation Preparation AC Current Measurement How to Use Peak Hold Function How to Use The

Heritage MedCall. Sentry E-Call Model HM-527 Resident Host Panel

PART 4 STANDARD DRAWINGS FOR CONSTRUCTION

USER S MANUAL PULSE INPUTS MODULE WITH PROVER SUPPORT

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

USER MANUAL 600A AC Clamp Meter + NCV Model MA610

Transcription:

PD132 Loop Detector Specification (Version 1.00)

Content 1. Application... 3 2. Technical Data... 3 3 Wiring Diagram... 3 4 Use and operational... 4 4.1 Frequency adjust... 4 4.2 Sensitivity adjust... 4 4.3 Filter option... 5 4.4 Function output relay... 5 4.5 Duration output time setting... 5 4.6 Reset... 5 5. Operating Guide... 6 5.1 Operational Constraints... 6 5.1.2 Crosstalk... 6 5.1.3 Reinforcing... 6 6 Installation Information... 7 6.1 Loop and Feeder Specification... 7 6.2 Sensing Loop Geometry... 7 6.3 Loop Installation... 7

1. Application Loop detectors are used wherever vehicles have to be detected. Like monitoring and safe guarding access ways to counting vehicles. The output signal can be used for controlling door and gate drive mechanisms, operating barriers, controlling traffic light systems in car parks or activating card dispensers in car parks. 2. Technical Data Operating voltage: 220V AC ±10% Power Consumption: 5VA Output relays: 240V/5A AC Frequency range: 20 khz to 170 khz Reaction time: 10ms Signal holding time: Unlimited / limited when loop is permanently covered 10 minutes Sensitivity: adjustable in 8 increments Wiring: 50µH to 1000 µh. Ideal is 150-300µH Loop connection wiring: Maximum length 20 meters, twisted at least 20 times per meter Autocorrecting time: 1to 2seconds Operating temperature: -20 C to +65 C Storage temperature: -40 C to +85 C Dimensions (include pedestal ): 78x40x108 mm (L x W x H) Net Weight (include pedestal): 265g Specific set the table below. In trial runs, first sensitivity in the lower stalls, the actual test vehicle detection if no response should be an increased sensitivity to stall, so repeated several times until the car seized stability for normal work. 3 Wiring Diagram Pin Designation 1 Live 230V AC 50/60 Hz 2 Neutral 3 Pulse Relay Normally Open contact 4 Pulse Relay Common contact 5 Presence Normally Open contact 6 Presence Relay Common contact 7 Blue Loop (twist this pair back to the control) 8 Blue Loop 9 Green Earth 10 Presence Relay Normally Closed contact 11 Pulse Relay Normally Closed contact

4 Use and operational On powering the PD-132 loop detector, it will automatically calibrate. When correct, it will show 2 LEDs. Do not leave a car on the loop or any other metallic objects when it is calibrating. If the calibration is successful, the detect LED turns off. Failure of the calibration is indicated by a flashing detect LED. When a car passes over the loop, the detect LED turns on. 4.1 Frequency adjust To avoid Crosstalk, please to select different frequencies and screened cables. There are 4 opt frequency.the can be altered by means of DIP1, DIP2Switch. 4.2 Sensitivity adjust The sensitivity can be adjusted on the front of the housing by means of a DIP3, DIP4 and DIP5 dip switches. Specifically set by varying the switches in the table below. Carry out trial runs with different vehicles, cars, bikes etc. Repeat several times until the detector has stability for normal work. Low high

4.3 Filter option When the environment has electromagnetic disturbance, resulting in frequent detector mis-operation, turn the DIP6 switch on to increase the filter coefficient, (filtering disturbance.) Please note that when the environment is normal turning DIP6 to the on position may reduce detector sensitivity detection or increase the delay time. Note: If the loop parameters laid are unreasonable, it may also lead to frequent detector mis-operation. These loop parameters should be amended or re-buried loop. 4.4 Function output relay *Pin5, pin 6, pin10: Relay Pulse Output. The output pulse relay can be altered by means of DIP7-Switch OFF when the car enters the loop, the pin5, pin6 closes the contacts and after 500ms switches-off. ON: only when the car leaves the loop, the pin5, pin6 closes the contacts and after 500ms switches-off. *pin3, pin4, pin11: Relay Presence Output. When the loop is occupied by the car or metal, the Pin3, pin 4 closes the contacts until the car leaves the loop. The duration decided by DIP8 4.5 Duration output time setting The duration output time setting can be programmed by means of DIP8-Switch. The presence time may be set to permanent presence or to limited presence. In permanent presence mode the detector will continuously compensate for all environmental changes whilst there is a vehicle present over the loop. The presence mode is set with switch No. 8 and is configured as follows: - SW8 Off - Limited Presence (The loop will automatically recalibrate after 10 minutes) On - Permanent Presence (The loop will only recalibrate by the reset switch) 4.6 Reset By powering off, then on again or pressing the reset panel buttons, or in limited duration mode over time there will detector reset operation. After reset, the detector will be initialized for a car-free state.

5. Operating Guide The detector must be installed in a convenient weatherproof location as close to the loop as possible. WARING: 1) This unit must be earthed. 2) Installation and operation by service professional only. 3) Disconnect power before working on this unit. A correct loop configuration and detector installation will ensure a successful inductive loop detection system. 5.1 Operational Constraints 5.1.2 Crosstalk When two loop configurations are in close proximity, the magnetic field of one can overlap and disturb the field of the other. This phenomenon, known as crosstalk, can cause false detect and detector lock-up. Crosstalk can be eliminated by: 1. Careful choice of operating frequencies of operation frequency. The closer together the two loops, the further apart the frequencies of operation must be. 2. Separation between adjacent loops.where possible a minimum spacing of 2 meters between adjacent loops. Where possible a minimum spacing of 2 meters between loops should be adhered to. 3. Careful screening of feeder cables if they are routed together with other electrical cables. The screen must be earthed at the detector end only. 5.1.3 Reinforcing The existence of reinforced steel below the road surface has the effect of reducing the inductance, and therefore the sensitivity, of the loop detection system.in this case two additional turns of wire should be added to the loop. The ideal spacing between the loop cable and steel reinforcing is 150mm, although this is not always practically possible. The slot depth should be kept as shallow as possible, talking care that no part of the loop or feeder remains exposed after the sealing compound has been applied.

6 Installation Information 6.1 Loop and Feeder Specification The loop must consist of insulated wire with a minimum copper cross-sectional area equivalent to 1.5 square millimeters. The feeder should be of the same material but twisted a minimum of 20 twists per meter. Joints in the loop or feeder are not recommended. Where this is not possible, Joints are to be soldered and terminated in a waterproof joint bow. This is extremely important for reliable detector performance. Where long loop feeders are used, or feeders are routed together with other electrical wiring, the use of a screened cable is suggested for the feeder. The screen must be earthed at the detector end only. 6.2 Sensing Loop Geometry Sensing loops should, unless site conditions prohibit, be rectangular in shape and should normally be installed with the longest sides at right angles to the direction of traffic movement. These sides should ideally be 1meter apart. The length of the loop will be determined by the width of the roadway to be monitored. The loop should reach to within 300rnmof each edge of the roadway. In general, loops having a circumference measurement in excess of 10 meters should be installed using 2 turns of wire, while loops of less than 10 meters in circumference should have three or more turns. Loops having a circumference measurement less than 6meters should be have four turns, It is good practice at time of installation to construct adjacent loops with alternate three and four turn windings to escape crosstalk. 6.3 Loop Installation All permanent loop installations should be installed in the roadway by cutting slots with a masonry cutting disc or similar device. A 45 crosscut should be made across the loop corners to reduce the chance of damage that can be caused to the loop cable at right angle corners. Nominal Slot width: 4mm Nominal Slot depth: 30mm to 50mm A slot must also be cut from the loop circumference at one corner of the loop to the roadway edge to accommodate the feeder. A continuous loop and feeder is obtained by leaving a tail long enough to reach the detector before inserting the cable into the loop slot. Once the required numbers of turns of wire are will into the slot around the loop circumference, the wire is routed again via the feeder slot to the roadway edge. A similar length is allowed to reach the detector and these two tree ends are twisted together to ensure they remain in close proximity to one anther.(minimum 20 turns per

meter).maximum recommended loop sensitivity decreases as the feeder length increases, so ideally the feeder cable should be kept as short as possible. The loops are seated using a quick-set black epoxy compound or hot bitumen mastic to blend with the roadway surface. 0.5m-1.5m 0.5m-1.5m road edge Sliding road edge Traffic direction Diagram 6

Wiring Example to gate controller for pulse exiting It is recommended that the condominium setting is enabled on gate controllers when using inductive loops. Gate Controller Com Start 0 0 Pin Designation 1 Live 230V AC 50/60 Hz 2 Neutral 3 Pulse Relay Normally Open contact 4 Pulse Relay Common contact 5 Presence Normally Open contact 6 Presence Relay Common contact 7 Blue Loop (twist this pair back to the control) 8 Blue Loop 9 Green Earth 10 Presence Relay Normally Closed contact 11 Pulse Relay Normally Closed contact

Inductive Loop Detectors Basic Layout Inductive loops work by detecting metal objects such as motor vehicles when the frequency of the loop is disturbed by the passing or presence of a vehicle. There are two basic ways to form a driveway inductive loop. In both cases the nearest wire to the surface 1) A saw cut loop buried directly in the traffic lane and the saw cut filled with a flexible resin. (Typically a concrete or tarmac surface) 2) With a preformed loop made from conduit

The loop itself is a continuous run of wire that enters and exits from the same point. A typical size of the loop in a single traffic lane would be 2.5m X 1m and the wire should go three or four times around the loop before exiting at the same point. The two ends of wire that exit the loop and return to the loop control box should be twisted together