EFFECT OF ARTIFICIAL MOUTH SIZE ON SPEECH TRANSMISSION INDEX. Ken Stewart and Densil Cabrera

Similar documents
Influence of artificial mouth s directivity in determining Speech Transmission Index

Implementation of a new metric for assessing and optimising speech intelligibility inside cars

ODEON APPLICATION NOTE Calculation of Speech Transmission Index in rooms

DESIGN OF VOICE ALARM SYSTEMS FOR TRAFFIC TUNNELS: OPTIMISATION OF SPEECH INTELLIGIBILITY

Measuring procedures for the environmental parameters: Acoustic comfort

THE USE OF VOLUME VELOCITY SOURCE IN TRANSFER MEASUREMENTS

Validation of lateral fraction results in room acoustic measurements

Measurement of weighted harmonic distortion HI-2

INTERNATIONAL STANDARD

EFFECTS OF PHYSICAL CONFIGURATIONS ON ANC HEADPHONE PERFORMANCE

Part V: Requirements and Test Methods for Magnetic Output From Handset Telephones for Hearing Aid Coupling and for Receive Volume Control

Technique for the Derivation of Wide Band Room Impulse Response

ECMA-108. Measurement of Highfrequency. emitted by Information Technology and Telecommunications Equipment. 5 th Edition / December 2010

Application Note: Headphone Electroacoustic Measurements

Technical Note Vol. 1, No. 10 Use Of The 46120K, 4671 OK, And 4660 Systems in Fixed instaiiation Sound Reinforcement

group D DSA250 Specifications 2-WAY FULL-RANGE DIGITALLY STEERABLE ARRAY See TABULAR DATA notes for details CONFIGURATION Subsystem Features

XLA 3200 Line Array Loudspeakers

Application Note 3PASS and its Application in Handset and Hands-Free Testing

ECMA-108. Measurement of Highfrequency. emitted by Information Technology and Telecommunications Equipment. 4 th Edition / December 2008

Convention e-brief 310

iw62 TDC Product Description Features Applications

iw6 TDC Product Description Features Applications

Loudspeaker Test. Report

3GPP TS V ( )

iw6 TDC Product Description Features Applications

Audio Engineering Society. Convention Paper. Presented at the 115th Convention 2003 October New York, New York

Case study for voice amplification in a highly absorptive conference room using negative absorption tuning by the YAMAHA Active Field Control system

Product Description. Features. Applications

High intensity and low frequency tube sound transmission loss measurements for automotive intake components

ODEON APPLICATION NOTE ISO Open plan offices Part 2 Measurements

Speech quality for mobile phones: What is achievable with today s technology?

Modeling Diffraction of an Edge Between Surfaces with Different Materials

Practical Limitations of Wideband Terminals

MK2399i Specifications

VLS 15. Technical Data Sheet. Product description. Features

Advanced techniques for the determination of sound spatialization in Italian Opera Theatres

CMS401e. Product Description

COMPARATIVE ANALYSIS OF ON-SITE STIPA MEASUREMENTS WITH EASE PREDICTED STI RESULTS FOR A SOUND SYSTEM IN A RAILWAY STATION CONCOURSE

iw6 DS Product Description Features Applications

INTERNATIONAL STANDARD

Considerations in characterising an almost anechoic room for interactive spatial audio reproduction

Improving the Effectiveness of Communication Headsets with Active Noise Reduction: Influence of Control Structure

PRODUCT DATA. DIRAC Room Acoustics Software Type Photo courtesy of Muziekcentrum Frits Philips, Eindhoven, The Netherlands

Electro-Voice S40. Full Range Compact Speaker System 160 Watts Power Handling Available is Black or White

IS SII BETTER THAN STI AT RECOGNISING THE EFFECTS OF POOR TONAL BALANCE ON INTELLIGIBILITY?

ETSI TS V1.1.1 ( ) Technical Specification

INTERIM EUROPEAN I-ETS TELECOMMUNICATION January 1996 STANDARD

Loudspeaker Test. Report

Impulse response. Frequency response

Estimates based on a model of room acoustics. Arthur Boothroyd 2003 Used and distributed with permission for 2003 ACCESS conference

REVERBERATION CHAMBER FOR EMI TESTING

3D Intermodulation Distortion Measurement AN 8

Measurement of Weighted Harmonic Distortion HI-2

Polar Measurements of Harmonic and Multitone Distortion of Direct Radiating and Horn Loaded Transducers

Public Address Systems

datasheet Impact 55T IMPACT SERIES ENGINEERING INFORMATION FEATURES APPLICATIONS 70v/100v line transformer with low impedance tap

USBPRO User Manual. Contents. Cardioid Condenser USB Microphone

Experimental evaluation of inverse filtering using physical systems with known glottal flow and tract characteristics

Operating Mode: PERFORMANCE Operating Range: Nominal Beamwidth: (rotatable) Horz 90 Vert 45 Axial Sensitivity (whole space SPL):

Operating Mode: PERFORMANCE 1 Operating Range: 57 Hz to 15 khz Nominal Beamwidth: (rotatable) Horz 120 Vert 60 Axial Sensitivity (whole space SPL):

Headphone Testing. Steve Temme and Brian Fallon, Listen, Inc.

SERIES P: TERMINALS AND SUBJECTIVE AND OBJECTIVE ASSESSMENT METHODS Voice terminal characteristics

Di5DC. Product Description. Features. Applications

Characterising the variation in oral-binaural room impulse responses for horizontal rotations of a head and torso simulator

Di6DC. Product Description. Features. Applications

SOURCE DIRECTIVITY INFLUENCE ON MEASUREMENTS OF SPEECH PRIVACY IN OPEN PLAN AREAS Gunilla Sundin 1, Pierre Chigot 2.

DISTANCE CODING AND PERFORMANCE OF THE MARK 5 AND ST350 SOUNDFIELD MICROPHONES AND THEIR SUITABILITY FOR AMBISONIC REPRODUCTION

Quadra 10 Available in Black and White

THE ERATO PROJECT AND ITS CONTRIBUTION TO OUR UNDERSTANDING OF THE ACOUSTICS OF ANCIENT THEATRES

datasheet TQ-310 QLIGHT SERIES ENGINEERING INFORMATION FEATURES APPLICATIONS CEW technology Trapezoidal cabinet Rotatable HF waveguide

VX 6. Product Description. Features. Applications

Loudspeaker Array Case Study

ANALYSIS OF MECHANICAL AND ELECTRICAL MODIFICATIONS THAT ALTER FREQUENCY RESPONSE

ENGINEERING STAFF REPORT. The JBL Model L40 Loudspeaker System. Mark R. Gander, Design Engineer

3D impulse response measurements of spaces using an inexpensive microphone array

PRELIMINARY. group S. M i cro W e dge M W 15 Speci f i cations. 2-Way full-range stage monitor See NOTES TABULAR DATA for details FEATURES DESCRIPTION

3GPP TS V ( )

PRELIMINARY. group S. MicroWedge MW12 Specifications 2-WAY FULL-RANGE STAGE MONITOR FEATURES DESCRIPTION. CONFIGURATION Subsystem

CMS401 DCe. Product Description. Features. Applications

LINE ARRAY Q&A ABOUT LINE ARRAYS. Question: Why Line Arrays?

How Accurate is Your Directivity Data?

COM 12 C 288 E October 2011 English only Original: English

OCV 6. Product Description. Features. Applications

3GPP TS V ( )

6-channel recording/reproduction system for 3-dimensional auralization of sound fields

R SERIES Premium Music R.5-96MAX HIGH OUTPUT FULL-RANGE 90 x 60 WEATHER-RESISTANT LOUDSPEAKER

Characterising the variation in oral-binaural room impulse responses for horizontal rotations of a head and torso simulator

Measurement Procedure & Test Equipment Used

MEASUREMENT PROCEDURE AND TEST EQUIPMENT USED

3GPP TS V ( )

not overpower the audience just below and in front of the array.

ITU-T P.57. Artificial ears. SERIES P: TERMINALS AND SUBJECTIVE AND OBJECTIVE ASSESSMENT METHODS Objective measuring apparatus

Binaural room impulse response database acquired from a variable acoustics classroom

EUROPEAN ETS TELECOMMUNICATION December 1994 STANDARD

VLS 15. Technical Data Sheet. Product description

Quadra 15 Available in Black and White

ETSI TS V1.1.2 ( ) Technical Specification

Technical Notes Volume 1, Number 25. Using HLA 4895 modules in arrays: system controller guidelines

Tonehole Radiation Directivity: A Comparison Of Theory To Measurements

ROOM SHAPE AND SIZE ESTIMATION USING DIRECTIONAL IMPULSE RESPONSE MEASUREMENTS

Transcription:

ICSV14 Cairns Australia 9-12 July, 27 EFFECT OF ARTIFICIAL MOUTH SIZE ON SPEECH TRANSMISSION INDEX Ken Stewart and Densil Cabrera Faculty of Architecture, Design and Planning, University of Sydney Sydney, NSW 26, Australia stewa_k@arch.usyd.edu.au Abstract For this study a head and torso simulator was constructed with a variable mouth size. Directivity measurements confirmed that a larger mouth size yields a more directional radiation pattern. The effect of the mouth size on speech transmission index (STI) measurements was investigated for various azimuth angles around the simulator and various room acoustical contexts. In some circumstances source directivity does affect STI values. 1. INTRODUCTION Speech transmission index (STI) is an objective method for rating speech intelligibility derived from the measurement of modulation transfer functions [1]. It yields a number between and 1, which is primarily affected by room acoustical effects (reverberation, early reflections and echoes) and signal to noise ratio (while room acoustical effects can degrade intelligibility, they can also increase signal to noise ratio, and so in some circumstances enhance intelligibility). To use STI in architectural acoustics, the test signal must be generated by a loudspeaker, the radiation characteristics of which should be similar to those of a human talker. One way to achieve this is with a head and torso simulator. Head and torso simulators are commercially available (the most common one is the Brüel & Kjær HATS) based on a specification from the International Telecommunication Union [2], which is concerned with the testing of telephone handsets and headsets. The extent to which this simulates long term average human speech directivity was examined by Chu and Warnock [3], with results indicating that the simulator is slightly more directional than humans (conversational speech). Other head and torso simulators have been developed for various purposes by Flanagan [4], Olson [5], Kob [6] and Bozzoli et al. [7], which probably all have different properties in terms of directivity, frequency-dependent sound power and temporal response. Bozzoli et al. [8] provide a precursor to the present study by examining how STI measurements are affected by the directivities of three head and torso simulators the Bruel & Kjaer HATS, a head-sized rectangular loudspeaker on a solid torso, and a shop mannequin with a small loudspeaker in the mouth position. Their study shows that STI can be substantially affected by the sound source in a car cabin (with an off-axis direct sound path), but there is very little effect in either a small or large classroom (with approximately on-axis direct sound paths).

The present study tests various head and torso simulator configurations by varying the mouth size of a mannequin based on the Brüel & Kjær HATS. This was done by building a new head from a casting of a Brüel & Kjær HATS (4128C), furnishing it with a loudspeaker, and making a collection of mouth inserts with a variety of orifice areas. We measured the directivity of these mouths in an anechoic chamber, along with that of the commercially produced HATS. Finally, we measured the STI produced by the various HATS mouths in two normal rooms as a function of rotation angle of the HATS. 2. CONSTRUCTION OF THE SIMULATOR For this experiment a cast was made in plaster of a Brüel & Kjær 4128C HATS. Using the cast a new head was fashioned using plastic vehicle repair putty. A large aperture was cut into the finished head so as to allow the insertion of various mouth shapes formed from Perspex. The mouth sizes chosen were: Regular :- 42mm x 16mm rectangular aperture the same size of the mouth of the 4128C HATS Small :- 42mm x 8mm rectangular aperture the same mouth height, but half the width; Round :- 12mm circular hole; and Large :- A fourth larger aperture obtained by leaving the mouth insert cavity vacant, yielding a 6mm x 32mm rectangular mouth size. Figure 1 shows the front section of the completed head with the regular sized mouth installed and the small and round mouths beside it. A 4-inch loudspeaker was installed directly behind the mouth and the new head was mounted on a Brüel & Kjær HATS torso. Figure 2 shows the completed new head along side the Brüel & Kjær HATS. Figure 1. Various mouth shapes and sizes Figure 2. Modified head and torso simulator 3. DIRECTIVITY MEASUREMENTS Firstly the directivity patterns of the various mouth configurations of the head and torso simulator were measured along with a Brüel & Kjær Type 4128C HATS. These patterns were measured using both a swept sinusoid impulse response technique and a steady state response technique using a computer controlled Brüel & Kjær Pulse electro-acoustic audio analysis

measurement system. The Pulse software was set up to control a turntable Type 964, generate a logarithmic sine-sweep tone into a Type 356 D-A converter and through a Type 2716C amplifier present the tone as a signal to the loudspeaker of the HATS under test. A half inch, free field measuring microphone Type 4189 was positioned in the horizontal plane of the HATS mouth centre and 2 metres directly in front with the HATS facing forward. The microphone returned a signal through the Type 356 input A-D converter, through a one-third octave band filter to record a decibel level for each centre frequency. After each measurement the turntable was set to rotate 1 degrees after which another measurement would be taken until completing the full 36 degrees. The measurements were conducted in a large anechoic room. Measurements were taken in the horizontal plane, as well as for elevation angles of 9 degrees, 6 degrees, 3 degrees and 3 degrees to the horizontal plane at a distance of 2 metres. The horizontal directivity patterns of every third 1/3-octave band are show in Figure 3. Figure 3. 1/3-octave band horizontal directivities centred on 125 Hz, 25 Hz, 5 Hz, 1 khz, 2 khz, 4 khz and 8 khz. Values are in decibels relative to degrees.

Chu and Warnock [3] have previously measured the directivity of the Brüel & Kjær HATS. Figure 4 provides a graph of deviations comparing of our measurements from their measurements (in every third 1/3 octave band). Deviations are within ±1 db up to 1 khz. The variation, which is more prominent in the higher frequencies, could be partly due to different axial centre zero alignments of the HATS with respect to the placement of the microphone, to minor reflections in one or the other measurement situation, and to differences in the centre of rotation. Deviation (db) 2 1-1 -2-3 -4-5 -6-7 -8-9 3 6 9 12 15 18 25Hz 5Hz 1Hz 2Hz 4Hz 8Hz Azimuth (degrees) Figure 4. Deviations in HATS directivity to Chu & Warnock measurements 4. STI MEASUREMENTS In order to check that the mouth fittings did not compromise STI values, STI was measured in the anechoic room for horizontal angles around the dummy head. The resulting STI was 1. in every case, meaning that the STI was not degraded by the measurement system itself. The five mouth size configurations were employed in three different room acoustical conditions to compare STI measurements. Two rooms were used a small conference room shown in Figure 5 and a lecture theatre. The conference room is approximately 18 cubic metres (6 x 5 x 3.6 m) and is dominated by a 2.4 metre diameter round table which has a laminated top. All the surfaces are hard and reflective and the STI was expected to be quite low for a room of this size. The measurement was recorded from one side of the table to not quite the other maintaining a distance of 2 m between source and receiver. STI measurements were taken at 2 degree rotations of the HATS using a swept sine tone convolved into an impulse response. The measurement excluded background noise (it was only sensitive to room acoustical effects). The STI values ( male weighting) were then assessed through the full rotation of the HATS (Figure 6). Figure 5. Modified HATS in the conference room

34.7 2 32.6 4 3 6.5 28 8.4 26 1 24 12 HATS1 Regular Small Large Round 22 2 18 16 14 Figure 6. STI in conference room The next measurements were taken in a moderately large (1 seat) lecture theatre with a volume of approximately 56 cubic metres. The first sets of measurement (Figure 7) were taken at a distance of 2 m in the horizontal plane, directly in front of the speaker which was situated in the front of the room. The second set (Figure 8) was made with the microphone moved into the centre of the seating area, approximately 7 m from the source. In each case the speaker was rotated through 36 degrees. 34.8 2 32.7 4 3.6 6 28 26.5.4 8 1 24 12 HATS1 Regular Small Large Round 22 2 18 16 14 Figure 7. STI at 2 m distance in the lecture theatre

34.7 2 32.6 4 3 6 28 26.5.4 8 1 24 12 Regular Small Large Round 22 14 2 16 18 Figure 8. STI in the lecture theatre audience area The STI measurements show little variation between the mouth configurations with source rotation. The only variation occurs when the simulator is facing away from the microphone for the 2 m sourcereceiver position in the lecture theatre (Figure 7). 5. DISCUSSION The directivity measurements show that mouth size can have an effect on source directivity. Differences are particularly prominent at 1 khz, for which the head diameter is approximately half a wavelength. Discrepancies between our directivity measurements and those of Chu and Warnock highlight the difficulty in accurately measuring source directivity. Discrepancies between the 4128C and our replication of it are partly due to a small rubber insert that is present in the orifice of the 4128C, but not in our model (making the effective mouth area smaller in the 4128C). The findings on the effect of simulator on STI are consistent with those Bozzoli et al. [8] i.e. there is very little effect in normal rooms. Our method of rotating the sound source provides an efficient way of exploring this question. In the small reverberant room, the reverberant field had a strong effect on STI, and so the rotation had little effect. An effect of rotation was only seen in the situation where the direct sound was relatively strong (within a reverberant field). Further measurements will be made to confirm this. One of the limitations of the 4128C is its low maximum acoustic power. A larger mouth area provides the potential for greater sound power, which could be helpful for measurements (for example, of singers or situations where stage voices are used). Combined with a higher power long excursion loudspeaker driver, our modified HATS has the potential to be useful in such situations.

6. CONCLUSIONS This study has shown that mouth directivity of a head and torso simulator is related to the mouth shape and size, but that this does not have a significant effect on STI measurements in general room acoustical conditions. 7. ACKNOWLEDGMENTS The authors thank National Acoustic Laboratories (Sydney, Australia) for providing access to their large anechoic chamber for directivity measurements. REFERENCES [1] International Electrotechnical Commission, Sound system equipment Part 16: Objective rating of speech intelligibility by speech transmission index, IEC 6268-16 (23). [2] International Telecommunication Union, Head and torso simulator for telephonometry, ITU-T Rec. P.58 (1996) [3] W.T. Chu and A.C.C. Warnock, Detailed directivity of sound fields around human talkers, National Research Council Canada IRC-RR-14 (22). [4] J. L. Flanagan, Analog measurements of sound radiation from the mouth, Journal of the Acoustical Society of America 32, 1613-162 (196). [5] H.F. Olson, Field-type artificial voice, Journal of the Audio Engineering Society 2, 446-452 (1972). [6] M. Kob, Physical modeling of the singing voice, PhD thesis, Logos Verlag, Berlin (22). [7] F. Bozzoli, M. Viktrorovitch and A. Farina, Balloons of directivity of real and artificial mouth used in determining speech transmission index, Proceedings of 118 th Audio Engineering Society Convention, Barcelona, Spain, May 25. [8] F. Bozzoli, P. Bilzi and A. Farina, Influence of artificial mouth s directivity in determining speech transmission index, Proceedings of 119 th Audio Engineering Society Convention, New York, New York, USA, October 25.