Wind Transmitter compact xx

Similar documents
Wind Transmitter compact xx

Wind Direction Transmitter - compact - GMR, analogue output xxx xxx

Instruction for Use /05/09. Wind Transmitter - compact x0.xxx x0.xx x0.xx0

Wind Transmitter - compact

Wind Direction Transmitter - compact - with Poti Output xx.712

Wind Direction Transmitter - compact - with serial output x0.x00

Wind Direction Transmitter - compact

Wind Transmitter First Class

Wind Transmitter First Class / 141 / / 141 / 161

Wind Direction Transmitter - compact - GMR, analogue output xxx

Wind Direction Transmitter - compact - with Poti Output xx.712

Wind Transmitter First Class Advanced Classified according to IEC ( )

Wind Direction Transmitter - compact - TMR, analogue output x.xxx xxx

Wind Direction Transmitter First Class analogue output x0.1xx

Wind Transmitter - with analogue output xxx

Wind Transmitter - with frequency output xx.xxx

Combined Wind Transmitter - with analogue output xxx

Wind Direction Transmitter First Class analogue output x0.1xx

Precipition Sensor with analogue Intensity Output ,

Precipitation Monitor ,

Wind Direction Transmitter First Class Low Power Device with digital output, 8 Bit serial-synchronous x0.000

WIND VANE THIES COMPACT

Precipitation transmitter

WIND VANE THIES COMPACT TMR

Precipitation Transmitter / 008 / 009 / 010 / 011 / 107 / / 009

Brightness Transmitter

THE WORLD OF WEATHER DATA Measurement and Documentation: Thies range of service for meteorology, environmental protection and industry

Wind Direction Transmitter First Class - Device with digital output, RS Wind velocity signal acquisition x0.400

WIND VANE THIES FIRST CLASS 2014 TMR

Precipitation Transmitter xxx / xxx

NEW. Automation Technology 768 series

Combi sensor C B1. A: Wind wheel. west, east, south C: Dawn sensor D: Rain sensor. Ref.-No. with DCF77 receiver WS 10 KSDCF (No KNX device)

WIND T H E W O R L D O F W E A T H E R D A T A

SW 16mm. SW 15mm. SW 19mm

Digital Anemometer

HARAX. Contents Technical characteristics circular connector with HARAX rapid termination 50.02

XXXX e. X d.. X X X a

XXXX e. X d.. X X X a

n Measurable displacements between n Linearity: max. ± 0.05 % n Housing diameter 12.9 mm n Service life: 10 8 movements

INSTALLATION INSTRUCTION RRU DOUBLE LIGHT POLE MOUNT

Sensor PAR xxx

Ensat driving tools...

Material Packing Brown Grey Pine Black White

Introduction. Applications

- 4 - Fig. 3b. Fig. 1b. Fig. 2. Fig. 2b MT 300

ABSOLUTE ROTARY ENCODER MULTI-TURN BIT PARALLEL

Enclosures, guards and partitions 6. Clamp Profiles Hangers Dual-Rod Mesh Hanger Lifting-Door System Door Security

Clamping devices 521

Adjustable Feet Castors Accessories for Floor Elements

Digital Input Output Module 24 V for Ex n Zone 2 Series 9472/35

OPERATING INSTRUCTIONS

Zero Point Clamping System. ZERO lock BALL lock

INSTRUCTION MANUAL VIBRATION SWITCH CVS 100 LC

MEFA mounting accessories

Digital flow ELEMENT transmitter for continuous flow measurement

Top spin Nr /

LENORD. +BAUER... automates motion. GEL 295x Customer-specific precision encoder. Technical Information Version General information.

Empfangsantennen / Receiving ROD Antennas STA E, STA E / EAU

Table and Furniture Base Fittings Plinth Adjusting Fittings

K1FO 12 ELEMENT 144/147 MHz YAGI

KINAX SR 719 Programmable Transmitter for Position Feedback

87.5 TO MHz BAND II 2 WAY 4.8dBi STACKED DIPOLE ANTENNA

ABSOLUTE ROTARY ENCODER SSI

Torque Sensor Series 3000 and Series 4000

Incremental Shaft Encoders Industrial types

Rotary Measurement Technology Incremental Encoders

INSERTION paddle wheel flowmeter for continuous flow measurement

Standard Sendix 5000 / 5020 (shaft / hollow shaft) Push-Pull / RS422 / Open collector. Robust performance. Many variants

TZ-RD-1740 Rotary Dipole Instruction Manual

STA 60 E = approx. 6 m STA 70 E = approx. 7 m. STA 60 E = approx. 5.3 kg STA 70 E = approx. 6.2 kg

Selection BASIC LINE BASIC LINE PLUS VARIO LINE SERIES TUBE LINE STEEL LINE

Spiderbeam Balun Construction Guide

Phone: Fax: Web: -

Rudder or propeller angular position transmitter KINAX WT720

Sport-Thieme. Handball Goal. Assembly instruction. 3x2 m, Free-standing with Fixed Net Brackets

10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units

NEWS Part. N /0 MINITEC NEWS

ELECTRIC TOOL CORPORATION

CHAINSAW SHARPENER MODEL: ECSS-1

Technical Information Condumax CLS21D/CLS21

N. 15th Street, Middlesboro, KY FLIP TARP DUMP BODY INSTALLATION INSTRUCTIONS

aluminium profile system

Single-point fixing serie S32/35

Condumax CLS21 and CLS21D

Amphenol. Circular. Connectors C 16-1 / C Circular Connectors. Amphenol-Tuchel Electronics

Instruction manual SUN-PM100L. SUN-PM100L Polishing Machine English

INLINE flowmeter for continuous flow measurement

The Ensat self-tapping threaded

INLINE flowmeter for continuous flow measurement

Diesel Pile Hammer D30-32 Part # 66508

adaptivemechanical adaptive

On-Roof Mounting Sets for Flat-Plate Collectors

Operating Instructions K-POWERgrip EWL Always on the safe site.

ABSOLUTE ROTARY ENCODER SSI

Measuring and Controlling Unit Multronic OC

Easy Step by Step Manual

Digital flow ELEMENT transmitter for continuous flow measurement

Condumax CLS21 and CLS21D

Product Manual MNX10050 / REV B MODELS:

Explosion proof rotary actuator - On/Off or programmable regulating actuator

Transcription:

THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA Instruction for Use 021720/03/14 Wind Transmitter compact 4.3519.xx.140... 961

Contents 1 Models... 3 2 Application... 4 3 Mode of Operation... 4 4 Recommendation Site Selection / Standard Installation... 4 5 Installation... 5 5.1 Mechanical Mounting... 5 5.2 Electrical Mounting... 6 5.3 Plug mounting... 6 6 Connecting Diagram... 7 7 Maintenance... 8 8 Technical Data... 9 9 Dimension diagram... 10 Figure Figure 1: plug mounting... 6 Figure 2: Connecting Diagram for Models with fixed Connecting Cable... 7 Figure 3: Connecting Diagram for Models with Connector... 8 Figure 4: Dimensional Drawing Model cable gland... 10 Figure 5: Dimensional Drawing Model plug... 10 Figure 6: Counter nut... 11 2-12 021720/03/14

1 Models Order - No. 4.3519.00.140 4.3519.00.840* Electrical Output Measuring range Heating power Connection 0...20 ma 0...50 m/s 20 W 12 m Cable LiYCY 6 x 0,25 mm² 4.3519.00.141 4...20 ma 0...50 m/s 20 W 12 m Cable LiYCY 6 x 0,25 mm² 4.3519.00.161 0...10 V 0 50 m/s 20 W 12 m Cable LiYCY 6 x 0,25 mm² 4.3519.00.167 0...2 V 0 50 m/s 20 W 12 m Cable LiYCY 6 x 0,25 mm² 4.3519.00.173 0...5 V 0 50 m/s 20 W 12 m Cable LiYCY 6 x 0,25 mm² 4.3519.00.361 0...10 V 0 3 m/s max. 13,8 V @ >3m/s 20 W 12 m Cable LiYCY 6 x 0,25 mm² 4.3519.00.441 4...20 ma 0 40 m/s 20 W 3 m PUR -Cable 6 x 0,25 mm² 4.3519.00.641 4...20 ma 0 60 m/s 20 W 12 m Cable LiYCY 6 x 0,25 mm² 4.3519.00.740 0 20 ma 0 50 m/s 20 W 7 pol. Plug 4.3519.00.741 4...20 ma 0 50 m/s 20 W 7 pol. Plug 4.3519.00.761 0...10 V 0...50 m/s 20 W 7 pol. Plug 4.3519.00.773 0...5 V 0...50 m/s 20 W 7 pol. Plug 4.3519.00.961 0...10 V 0 15 m/s 20 W 12 m Cable LiYCY 6 x 0,25 mm² 4.3519.01.140 0...20 ma 0 50 m/s 20 W 1,5-3 m Spiral Cable LiYY 6x0,14 mm² 4.3519.02.141 4...20 ma 0 50 m/s 10 W 2 m Cable 6 x 0,56 mm² 4.3519.04.441 4...20 ma 0 40 m/s 20 W 0,95 m PUR- Cable 6 x 0,25 mm² 4.3519.05.141 4...20 ma 0 50 m/s 20 W 15 m Cable LiYCY 6 x 0,25 mm² 4.3519.05.161 0 10 V 0 50 m/s 20 W 15 m Cable LiYCY 6 x 0,25 mm² 4.3519.05.641 4...20 ma 0 60 m/s 20 W 15 m Cable LiYCY 6 x 0,25 mm² 4.3519.10.441 4...20 ma 0 40 m/s Without heating 12 m Cable LiYCY 6 x 0,25 mm² 4.3519.20.141 4...20 ma 0...50 m/s 10 W 12 m Cable LiYCY 6 x 0,25 mm² 4.3519.39.141 4...20 ma 0 50 m/s 20 W 12 m Cable LiYCY 6 x 0,25 mm² with cable lug at the shield 4.3519.40.140 0...20 ma 0...50 m/s 60 W 12 m Cable LiYCY 6 x 0,5 mm² 4.3519.40.141 4...20 ma 0...50 m/s 60 W 12 m Cable LiYCY 6 x 0,5 mm² 4.3519.40.161 0...10 V 0 50 m/s 60 W 12 m Cable LiYCY 6 x 0,5 mm² 4.3519.40.167 0...2 V 0 50 m/s 60 W 12 m Cable LiYCY 6 x 0,5 mm² 4.3519.40.173 0...5 V 0 50 m/s 60 W 12 m Cable LiYCY 6 x 0,5 mm² 4.3519.40.740 0 20 ma 0 50 m/s 60 W 7 pol. Plug 4.3519.40.741 4...20 ma 0 50 m/s 60 W 7 pol. Plug 4.3519.40.761 0...10 V 0...50 m/s 60 W 7 pol. Plug * Counter nut inverse-mounted, see figure 6. 3-12 021720/03/14

2 Application The wind transmitter detects the horizontal wind speed. The measured values are available at the output as analogue voltage or current signal to control for instance wind power plant. An electronically-regulated heating system has been installed in some models (see chapter 1) for winter time use, in order to prevent the ball-bearing and the external rotation parts from freezing. Thanks to the 60-Watt-heating as well as to the optimized regulating characteristic, model no. 4.3519.40.xxx is especially suited for the extremely difficult application in high mountains or at other critical sites, where icing is to be expected. 3 Mode of Operation The cup star (in ball bearing) is set into rotation by the wind. An opto-electronic speed scanning produces a frequency which is transformed into an analogue signal by an integrated measuring transformer. The outer parts of the instrument are made of corrosion-resistant materials. Labyrinth gaskets protect the parts inside the instrument against precipitations. 4 Recommendation Site Selection / Standard Installation In general wind measurement instruments should be able to detect the wind conditions of a large area. In order to obtain comparable values when determining the surface wind, measurements should be taken at a height of 10 meters over an even area with no obstacles. An area with no obstacles means that the distance between the wind direction transmitter and an obstacle should be at least 10 times the height of the obstacle (s. VDI 3786). If it is not possible to fulfil this condition then the wind direction transmitter should be set up a height where local obstacles do not influence the measured values to any significant extent (approx. 6-10 m above the obstacle). The wind direction transmitter should be set up in the centre of flat roofs and not on the edge in order to avoid any preferential directions. 4-12 021720/03/14

5 Installation Attention: Storing, mounting and operation under weather conditions is permissible only in vertical position, as otherwise water can get into the instrument. Remark: When using fastening adapters (angle, traverses, etc.) please take a possible effect by turbulences into consideration. Caution: The device may only be supplied with a power supply of the,,class 2, limited power. 5.1 Mechanical Mounting The mounting of the transmitter could be done for example at a support with a boring of PG 21 or on hangers with a boring of 29 mm. Tools: Procedure: Hexagonal wrench SW36 1. Push cable/ plug connector of the wind transmitter through the borehole of the mast, tube, arm etc. 2. Put wind transmitter on mast, tube, arm etc. 3. Safeguard the wind direction transmitter by two hexagonal nuts (PG21, SW 36). Remark: The support is not included in delivery. 5-12 021720/03/14

5.2 Electrical Mounting For electrical connection please refer to the connecting diagram. 5.3 Plug mounting Applies only to instruments with connection plug. Coupling socket, Typ:Binder, Serial 423, EMC with cable clamp Cable connection: without cable shield Cable- pull- relief 1. Stringing parts on cable acc. to plan given above. 2. Stripping cable sheath 20 mm 3. Cutting uncovered shield 20 mm 4. Stripping wire 5mm. 5. Soldering wire to the insert 6. Positioning shield in cable clamp. 7. Screwing-on cable clamp. 8. Assembling remaining parts acc. to upper plan. 9. Tightening pull-relief of cable by screw-wrench (SW16 und 17). Cable clamp Wire Cable sheath Figure 1: plug mounting 6-12 021720/03/14

6 Connecting Diagram Order No. Separate Voltage Supply Shared Voltage Supply 4.3519.00.140 4.3519.00.141 4.3519.00.161* 4.3519.00.167 4.3519.00.173 4.3519.00.361* 4.3519.00.441 4.3519.00.641 4.3519.00.840 4.3519.00.961* 4.3519.01.140 4.3519.02.141 4.3519.04.441 4.3519.05.141 4.3519.05.161 4.3519.05.641 4.3519.10.441 4.3519.20.141 4.3519.39.141 4.3519.40.140 4.3519.40.141 4.3519.40.161* 4.3519.40.167 4.3519.40.173 Pg 9 Cable gland / Cable white 123456 brown ~~ ~~ + + Power 9 (13)...30 V D C or 24 V AC green yellow + + ~~ + Analog Output grey Heating pink Shield Ground Pg 9 Cable gland / Cable white 123 4 56 brown Power 24 V AC / DC green yellow grey pink Shield Ground Order-No 4.3519.10.441 (Instrument without heating) Pin 5 and 6 not connected Figure 2: Connecting Diagram for Models with fixed Connecting Cable 7-12 021720/03/14

Order No. Separate Voltage Supply Shared Voltage Supply 4.3519.00.740 4.3519.00.741 4.3519.00.761* 4.3519.00.773 4.3519.40.740 4.3519.40.741 4.3519.40.761* 7 pol. Plug Heating 7 pol. Plug Heating View on the soldered joint of the counter plug 1 2 3 4 5 6 7 ~ ~ ~ ~ + + 1 2 3 ~ ~ + + 4 5 6 7 3 4 2 7 1 6 5 + Power 9 (13).. 30 V DC or 24 V AC Analog Output Heating 24 V AC / DC Power 24 V AC / DC Analog Output Figure 3: Connecting Diagram for Models with Connector 7 Maintenance After proper mounting the instrument works maintenance free. Heavy pollution can clog up the slit between the rotating and the stationary parts of the wind transmitter. This slit must be kept clean. Cleaning For the cleaning of the device should use a damp cloth without chemical cleaning agents are used. 8-12 021720/03/14

8 Technical Data Measuring range Resolution Starting velocity Accuracy See model 0,1 m/s 0,5 m/s ± 0,5 m/s or ± 3% of measuring value Delay distance < 3,5 m (acc. to DIN ISO 17713-1) Measuring principle Electrical output Load for current output (ma) for current output (V) Electrical supply for electronics Opto-electronic (slotted disc) See model max. 500 Ohm (for operating voltage > 15 V DC) min. 1 KΩ U: 9 30 V DC oder 24 V AC/DC I: 0,05A P: 1,5 W *für 0-10 V output U: 13 30 V DC oder 24 V AC/DC I: 0,05A P: 1,5 W Electrical supply for heating 4.3519.00/01/02/04/05/20/39.xxx U: 24V AC/DC, 45 65Hz I: 0,83A P: 20 W Operating voltage heating Survival speed Connection Dimensions Montage 4.3519.20.xxx U: 24V AC/DC, 45 65Hz I: 0,42A P: 10 W Protection IP 55 Weight Material 4.3519.40.xx U: 24V AC/DC, 45 65Hz I: 2,5A P: 60 W Housing Cup star Bottom -40 C...70 C maximally 80 m /s, 30 minutes See model See dimensional drawing For ex. onto mast tube with receptacle thread Pg 21 or boring Ø 29 mm 0,40 0,75 kg depending on model Aluminium (AlMgSi1) Synthetic, with fibre glass (PC-GF10) Synthetic (POM H2320) 9-12 021720/03/14

9 Dimension diagram Figure 4: Dimensional Drawing Model cable gland Figure 5: Dimensional Drawing Model plug 10-12 021720/03/14

Assembly condition of the counter nut ex works 4.3129.xx.xxx 4.3129.00.840 Figure 6: Counter nut 11-12 021720/03/14

12-12 021720/03/14