SVM F27 Compact. Ultrasonic heatmeter. Data sheet

Similar documents
SVM F27 / C27. Ultrasonic BTU meter for heating or cooling. Data sheet

SVM F27 Compact. Compact heat meter. Users manual

SVM F22. Calculator for heating or cooling applications. Data sheet

SVM F2 Calculator. A small competent calculator for compact or wall montage. Users manual

User s Manual. F2 Calculator. A metering component for thermal energy applications

SHARKY 775 ULTRASONIC COMPACT METER. 4 Approved according EN 1434 and MID in class 2 with dynamic range of 1:250 (qi:qp) in class 2

SHARKY 775 ULTRASONIC COMPACT METER. 4 Approval with dynamic range up to 1:250 (qi:qp) MID in class 2 (depends on meter size), standard 1:100

SHARKY 775 ULTRASONIC COMPACT METER. 4 Approved according EN 1434 and MID in class 2 with dynamic range of 1:250 (qi:qp) in class 2

RAY MECHANICAL COMPACT METER. 4 MID approved class 2 from ND 15 mm qp 0,6 m3/h up to ND 40 mm qp 10 m3/h

SVM F22 SVM F27. Calculator for heating or cooling applications. Ultraljudsmätare. Installation Guide. Datablad

SONOMETER TM 1100 Ultrasonic compact energy meter

Brunata Optuna H. Properties. Counter

RAY COMPACT ENERGY METER MECHANICAL

SonoMeter 31 Energy Meters

SONOMETER TM 1100 Ultrasonic compact energy meter

EW447-EW452 Series Mechanical Heatmeters FOR HEATING AND COOLING APPLICATIONS

RAY MC COMPACT ENERGY METER MECHANICAL

RAY MC COMPACT ENERGY METER MECHANICAL

WESAN WP E ELECTRONIC METER WOLTMAN

Portfolio. and ULTRAWATER. Ultrasonic Static Meters. Ultrasonic Meters Residential and District Heating/ Cooling Water Measurement

INFOCAL 8 Energy calculator

ULTRASONIC D. Compact ultrasonic heat meter

SonoSelect 10 and SonoSafe 10 Energy Meters

SONOMETER TM 1000 Ultrasonic compact heat meter

SONOMETER 2000 Ultrasonic heat meter

Infocal 9 Energy calculator

Supercal 531 Multi function Integrator that lives up to Your highest expectations

MULTICAL 302 DATA SHEET

Heat meter Q heat 5 US

US-W/V US-S/FFL. Certificate No.: DE-09-MI004-PTB018 (MID heat) / 22.72/09.01 (National German cooling)

SONO 1500 CT Ultrasonic flow sensor

MULTICAL 601 DATA SHEET

MULTICAL Energy meter TS PTB. Application

Electronic Heating Energy Meters

ultego III smart plus

Siemens Switzerland Ltd HVAC Products. SIEMECA Electronic Heat and Cooling Meters

FLOMID FX Electromagnetic Flowmeter

ULTRAHEAT / ULTRACOLD T330. The Evolutionary. Ultrasonic Heat Meter / Cooling Meter. Ultrasonic Heat Meter / Cooling Meter.

MULTICAL 403. Data sheet

ULTRAHEAT / ULTRACOLD T330. The Evolutionary. Ultrasonic Heat Meter / Cooling Meter. Ultrasonic Heat Meter / Cooling Meter.

ULTRAFLOW. Application. Cooling flow sensor. Ultrasonic flow sensor. Compact design. Static meter with no moving parts. Large dynamic range.

ULTRAHEAT T230 ULTRACOLD T230

MULTICAL 602 DATA SHEET

3 PHASE ENERGY ELECTRONIC METERS MKT & MKT2. (Code to ) INSTRUCTION MANUAL ( M / 00 A ) (c) CIRCUTOR S.A.

Size : Connection End : Min Temperature : Max Temperature : Materials : Cast iron body

ULTRAFLOW TS PTB. Application. Ultrasonic flow sensor. Compact design. Static meter with no moving parts. Large dynamic range.

Installation and Operating Instructions Compact Heat Meter Compact Heat / Cooling Meter Amtron

HDU-SF (Horizontal Distribution Units - Single Flat)

Size : Connection Ends : Min Temperature : Max Temperature : Materials : Cast iron body

MULTICAL 602. Data sheet. Heat and cooling meters with unlimited communication

MULTICAL 603. Data sheet. The future-proof heat and cooling meter with full flexibility

Single phase meter with direct connection and pulse or Modbus RS485 output

Design and applications

microclima Single Jet SENSOSTAR 2/2+ DE-07-MI004-PTB025 (MID, heat)

Flow Measurement SITRANS F US Inline

3-phase meter with direct connection and pulse or Modbus RS485 output

microclima/sensostar 2/2+ MSH

Price list 2018 Devices

Universal process controller econtrol

MULTICAL 403. Data sheet

The innovative way forward symphonic sensor net radio system

SITRANS F flowmeters SITRANS F US. Transmitter FUS080. 4/194 Siemens FI

ULTRAFLOW TS Application OIML R75 DS/EN 1434

SITRANS F US SONOCAL series 3000

Brunata. Technical Manual for HGP-series. Volume and Energy Meters, 15 to 600 m3/h

Ultrasonic heat and cooling energy meters

SITRANS F US SONOCAL series 3000

Flow Measurement. SITRANS F US Inline. Flowmeter SITRANS FUS380 standard. 4/254 Siemens FI Overview

Universal process controller econtrol

Brunata Optuna H Ultrasonic energy meter Type 775 Installation Guide Edition 1.2

HMM/CHW CHW Heat Meters

High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals

mass flowmeter for compressed air

Digital flowmeter for continuous flow measurement

1.2 M-Bus (optional) The M-Bus is a galvanically isolated interface for the transmission of meter data (absolute values).

Measurement. SITRANS F US Inline. 3/262 Siemens FI Transmitter SITRANS FUS080/FUE080

Flow Measurement SITRANS F US Inline

Technical Description ULTRAFLOW 54 DN

Universal process controller econtrol

Acti 9 Energy Meters. iem3000 Series. Technical data sheet

HMM/LPHW LPHW Heat Meters

Acti 9 Energy Meters. iem3000 Series. Technical data sheet

SITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview

Energy Meters for DIN Rail Mounting Electric energy meter WS0101, WS0102,WS1102 WS0301, WS0302,WS1302

flowiq 3100 Data sheet

Digital flowmeter for continuous flow measurement

Flow Switch - 2 programmable thresholds. Stand Alone (Battery) - Battery powered, - 2 totalizers display, - Local flow display,

Installation & Operation Manual

SITRANS F flowmeters SITRANS F US. Flowmeter FUE380 with approval. 4/230 Siemens FI Overview

ULTRA RAPID POWER QUALITY ANALYZER

UTM10 Series Ultrasonic Transit-time Flowmeters

MULTICAL 603. Data sheet. The future-proof heat and cooling meter with full flexibility

Instruction. SONOMETER 1100 Ultrasonic compact energy meter. 1.0 Table of contents. 2.0 Safety notes and product information

DUK COMPACT ULTRASONIC FLOWMETER

MID MP-01, MP WATER MEASUREMENT

Measuring and Controlling Unit Multronic OC

ISO 9001 PN-N ISO

Instruction. INFOCAL 8 Energy calculator. 1.0 Table of contents. 2.0 Safety notes and product information

DIGEM f 96 x 48 EK. Applications. Description

SITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview

Transcription:

SVM F27 Compact Ultrasonic heatmeter Data sheet

Application field F27 is a heat meter for debiting and monitoring heat energy consumption. F27 is a flexible compact heat meter with an ultra sonic flow sensor. The calculator part of F27 can be mounted on the flow sensor in four different positions or on a wall (split), cable length 1m. F27 s flow sensor can be delivered for threaded connection or flanged. F27 threaded Qp 0.6 2.5 [m³/h] are prepared for direct mounted temperature sensor. Measurement The energy calculation is based on measured volume and measured temperature difference between the temperature sensors (H/L). The temperatures are measured at each energy calculation or at each 60 seconds. F27 is designed for good dynamic behavior. The energy measurement is done every 5 seconds and the flow is measured twice every second. Communication F27 has a galvanic isolated M-Bus data output, M-bus according to EN1434-3. Data can be read through the optical interface or two wire M-Bus connection (isolated). Display F27 has a 7-digit LCD-display. The display can be ordered with backlight. Example of a display image, showing accumulated energy. Pulse inputs / pulse outputs F27 has two pulse outputs, energy (pulse 1) and volume (pulse 2). The pulse outputs are of the type open collector. In the F27 there are jumpers to set the pulse outputs to pulse inputs. One or both outputs can be changed to pulse inputs. Pulse inputs can be used to read off other meters, e.g. cold, hot water meters. Option The F27 can be factory mounted with options, these are: Peek values Tariff Logg

Data In addition to accumulated energy, the following (among others) values are accessible in F27: Accumulated volume for the extra pulse inputs Error code and accumulated time for the relevant error Momentary power Momentary flow Flow temperature Return temperature Temperature difference Total operating time Meter number Manufacturing number Real time clock with date function Pulse value Flow sensor placing (high or low temp.) Accumulated volume according to flow sensor Accumulated volume registered in conjunction with energy calculation Total error time Preceding error code and accumulated time for this error Up to 37 monthly registers ( same values as for account days, see below) Recommended date for battery replacement. Two account days. On each account day the following values are stored: Date Accumulated energy Accumulated volume according to the flow sensor Accumulated volume registered during energy calculation Accumulated volume for the extra pulse inputs Possible error code at the time of saving and accumulated time for the relevant error Service With a service button and the display button it is possible to change several parameters without using a special service tool. Following values can be changed: Time and Date Account days Communication address Flow sensor placing (H/L), supply (H) or return (L) Recommended date for battery replacement Furthermore, the total error time can be reset. Other parameters in F27 can be altered through a PC-program. Technical data F27 Power supply Battery Mains 3.6 V 16 Ah Operation time max. 10 years* 230 V ± 10%, 45-65 Hz, battery 3.6 V - 1.0 Ah as spare Ambient temperature Operation +5 C to +55 C Storage/transport -20 C to +70 C Temperature sensors Approved and matching pairs type Pt 100 can be used Max. cable length 2,5 m at 0,22 mm² cable area 5,0 m at 0,50 mm² cable area Max sensor current 4 µa (RMS) for Pt 100 Display 7 + 2 digits, LCD Backlight (option) only in mains supplied F27 Temperature Range 0-190 C Difference 2-120 K Protection IP54 Environmental class C according to EN1434 Data output M-Bus (EN1434-3) OPTO interface (EN60870-5) and buss connection, terminals (isolated) Pulse outputs Pulse length Max voltage Max current Pulse inputs Max frequency Min pulse length Voltage from calculator to be connected to inputs of the type open collector 250 ms 30 V 20 ma of the type open collector can be set with jumpers 12 Hz 40 ms 3.6 V Alarm output Pulse length Open collector 250 ms * Vaild at normal operation. When F27 is equipped with additional functions or operating at high load contact Metrima for battery calculation.

Technical data flow sensor Accuracy class 2* Environmental class C Metrological class 1:100 (dynamic range) Installation orientation Horizontal or Vertical Installation placing Return or supply Temperature range +10 C -- +130 C Max. temperature +150 C in max. 2000h Max. flow 2.8 x qp (for some types even more) Medium Water * Qp 2.5 accuracy class 3 Pulses Kv- graph qp Kv Flow [m3/h] At flows higher than Kv the flow sensor will emitt pulses equal to Kv Threaded Type Qp G length Qs max.fl. Qi min.fl. Qstart Pressure drop at qp PN Weight Kv [m³/h] [mm] [m³/h] [l/h] [l/h] [mbar] [m³/h] [kg] [l/p] 0 0.6 G3/4 110 1.2 6 2.4 140 16 1.6 1 1 1 1.5 G3/4 110 3 15 6 130 16 4.2 1 1 2 0.6 G1 130 1.2 6 2.4 140 16 1.6 1 1 3 1.5 G1 130 3 15 6 130 16 4.2 1 1 4 2.5 G1 130 5 25 10 205 16 -- 1.5 1 5 3.5 G1¼ 260 7 35 14 65 16 14.3 3 2.5 6 6 G1¼ 260 12 60 24 190 16 14.6 3 2.5 7 10 G2 300 20 100 40 120 16 29 4 10 Flanged Type Qp DN length Qs max.fl. Qi min.fl. Qstart Pressure drop at qp PN Weight Kv [m³/h] [mm] [m³/h] [l/h] [l/h] [mbar] [m³/h] [kg] [l/p] A 3,5 25 260 7 35 14 65 25 14.3 5 2.5 B 6 25 260 12 60 24 190 25 14.6 5 2.5 C 10 40 300 20 100 40 120 25 29 7 10 D 15 50 270 30 150 60 120 25 43 8 10 E 25 65 300 50 250 100 70 25 94 11 10 F 40 80 300 80 400 160 120 25 115 13 25 G 60 100 360 120 600 240 140 16 160 22 25 Pulse value Pulse value Pressure drop characteristics 1000 Pressure drop [mbar] 100 500 mbar 250 mbar qp 0.6 qp 1.5 qp 2.5 qp 3.5/6 qp 10 qp 15 qp 25 qp 60 qp 40 10 0,1 1 10 Flow rate [m3/h] 100

Dimensions All dimensions are in mm Threaded Type Qp G a b h [m³/h] 0 0.6 G3/4 110-77 1 1.5 G3/4 110-77 2 0.6 G1 130-77 3 1.5 G1 130-77 4 2.5 G1 130-74 5 3.5 G1¼ 260 51 111 6 6 G1¼ 260 51 111 7 10 G2 300 68 108 h b a G Flanged Type Qp DN a b h Øc Ød Øe No.of f g [m³/h] holes HCD A 3,5 25 260 51 111 115 85 14 4 68 18 B 6 25 260 51 111 115 85 14 4 68 18 C 10 40 300 48 108 150 110 18 4 88 18 D 15 50 270 46 106 165 125 18 4 102 20 E 25 65 300 52 112 185 145 18 8 122 22 F 40 80 300 56 116 200 160 18 8 138 24 G 60 100 360 68 128 235 190 22 8 158 24 a g Øc Ød Øe f b h Electronics The electronic can be separated from the flow part and hooked on to a wall. The fastening device on flow part can be used to screw the electronics on the wall. 67 Ø7.8 SERVICE 75 112 60 120

F27 threaded F27 ABCDEFGHIJ KLM A 1 Pt100 2-wire measurement, flow sensor in low (L) temp. A 2 Pt100 2-wire measurement, flow sensor in high (H) temp. B 1 Battery supply (3.6V 16Ah) B 3 Mains supplied 230V (with backup battery 1.0 Ah) C 1 Pulse weight 2.5 [l/p] at qp= 3.5/6.0 [m³/h] C 5 Pulse weight 1 [l/p] at qp= 0.6 / 1.5 / 2.5 [m³/h] C 6 Pulse weight 10 [l/p] at qp= 10.0 [m³/h] D 0 kwh [kw m³ m³/h] D 1 MWh [kw m³ m³/h] D 2 GJ [kw m³ m³/h] D 3 MBTU [kw m³ m³/h] D 4 MBTU [kusg kw USG/m] E - Standard order E S Special, extra ordering information enclosed with order. Example customer information F H Pulse output, STANDARD. Jumpers for pulse inputs 1000[l/p]. G 1 No backlight (STANDARD) G 0 Backlight (option, ONLY in F27 mains supplied) H 0 qp= 0.6 [m³/h], 110[mm], G3/4 PN16 C5 1 l/p H 1 qp= 1.5 [m³/h], 110[mm], G3/4 PN16 C5 1 l/p H 2 qp= 0.6 [m³/h], 130[mm], G1 PN16 C5 1 l/p H 3 qp= 1.5 [m³/h], 130[mm], G1 PN16 C5 1 l/p H 4 qp= 2.5 [m³/h], 130[mm], G1 PN16 C5 1 l/p H 5 qp= 3.5 [m³/h], 260[mm], G1 1/4 PN16 C1 2.5 l/p H 6 qp= 6.0 [m³/h], 260[mm], G1 1/4 PN16 C1 2.5 l/p H 7 qp=10.0 [m³/h], 300[mm], G2 PN16 C6 10 l/p I - No temperature sensor eqipped with F27 I 1 TDA26 temperature sensor, 2m silicone (ONLY qp=0.6 qp=2.5 can a TDA26 be mounted directly in the flow sensor) I 3 TL045, 2m silicone I S Special temperature sensors, specified separately on order J 1 Standard mounting KLM #00 Country code Only TDA26 temperature sensors with a cut in the screw may be used in the flow part. F27 threaded flow parts

F27 Flanged F27 ABCDEFGHIJ KLM A 1 Pt100 2-wire measurement, flow sensor in low (L) temp. A 2 Pt100 2-wire measurement, flow sensor in high (H) temp. B 1 Battery supplied (3.6 16Ah) B 3 Mains supplied 230V (with backup battery 1.0 Ah) C 1 Pulse weight 2.5 [l/p] endast qp=3.5/6 [m³/h] C 2 Pulse weight 25 [l/p] endast qp=40/60 [m³/h] C 6 Pulse weight 10 [l/p] endast qp=10/15/25 [m³/h] D 0 KWh D 1 MWh D 2 GJ D 3 MBTU D 4 MBTU [kusg kw USG/m] E - Standard order E S Special, extra information enclosed with order. Example customer information F H Pulse output, STANDARD. Jumpers for pulse inputs 1000[l/p]. G 1 No backlight (STANDARD) G 0 Backlight (option, ONLY in F27 mains supplied) H A qp= 3.5 [m³/h], 260[mm], DN25, flange PN25 C1 2.5 l/p H B qp= 6.0 [m³/h], 260[mm], DN25, flange PN25 C1 2.5 l/p H C qp=10.0 [m³/h], 300[mm], DN40, flange PN25 C6 10 l/p H D qp=15.0 [m³/h], 270[mm], DN50, flange PN25 C6 10 l/p H E qp=25.0 [m³/h], 300[mm], DN65, flange PN25 C6 10 l/p H F qp=40.0 [m³/h], 300[mm], DN80, flange PN25 C2 25 l/p H G qp=60.0 [m³/h], 360[mm], DN100, flange PN16 C2 25 l/p I - No temperature sensor equipped with F27 I 3 TL045, 2m silicone sensor I S Special temperature sensors, specified separately on order J 1 Standard mounting KLM #00 Country code F27 flanged flow parts Metrima AB Norra Stationsgatan 93 SE-113 64 Stockholm Phone: +46-8 23 60 30 Fax: +46-8 23 60 31 www.metrima.se info@metrima.se 3-02-07E 060120/EW