Precision displacement measurement by active laser heterodyne interferometry

Similar documents
High stability multiplexed fibre interferometer and its application on absolute displacement measurement and on-line surface metrology

Two-Mode Frequency Stabilization of an Internal-Mirror 612 nm He-Ne Laser

CHAPTER 5 FINE-TUNING OF AN ECDL WITH AN INTRACAVITY LIQUID CRYSTAL ELEMENT

visibility values: 1) V1=0.5 2) V2=0.9 3) V3=0.99 b) In the three cases considered, what are the values of FSR (Free Spectral Range) and

Development of innovative fringe locking strategies for vibration-resistant white light vertical scanning interferometry (VSI)

Optical phase-locked loop for coherent transmission over 500 km using heterodyne detection with fiber lasers

Multiply Resonant EOM for the LIGO 40-meter Interferometer

Use of single-mode optical fiber in the stabilization of laser frequency

D.C. Emmony, M.W. Godfrey and R.G. White

Wavelength Control and Locking with Sub-MHz Precision

Experimental Test of an Alignment Sensing Scheme for a Gravitational-wave Interferometer

ULTRASONIC TRANSDUCER PEAK-TO-PEAK OPTICAL MEASUREMENT

Polarization Sagnac interferometer with a common-path local oscillator for heterodyne detection

R. J. Jones Optical Sciences OPTI 511L Fall 2017

Optical fiber-fault surveillance for passive optical networks in S-band operation window

High Sensitivity Interferometric Detection of Partial Discharges for High Power Transformer Applications

Active cancellation of residual amplitude modulation in a frequency-modulation based Fabry-Perot interferometer

A broadband fiber ring laser technique with stable and tunable signal-frequency operation

Real-time displacement measurement using VCSEL interferometer

Stability of a Fiber-Fed Heterodyne Interferometer

Advanced Virgo commissioning challenges. Julia Casanueva on behalf of the Virgo collaboration

Realization of 16-channel digital PGC demodulator for fiber laser sensor array

Powerful Single-Frequency Laser System based on a Cu-laser pumped Dye Laser

Installation and Characterization of the Advanced LIGO 200 Watt PSL

Measurements of linewidth variations within external-cavity modes of a grating-cavity laser

Temporal coherence characteristics of a superluminescent diode system with an optical feedback mechanism

Optical generation of frequency stable mm-wave radiation using diode laser pumped Nd:YAG lasers

A Multiwavelength Interferometer for Geodetic Lengths

A novel algorithm for the signal interpolation of the displacement measurement based on a Fabry-Perot interferometer

Recent Developments in Fiber Optic Spectral White-Light Interferometry

Optical phase-coherent link between an optical atomic clock. and 1550 nm mode-locked lasers

A review of Pound-Drever-Hall laser frequency locking

Periodic Error Correction in Heterodyne Interferometry

21.0 Quantum Optics and Photonics

Stabilized Interrogation and Multiplexing. Techniques for Fiber Bragg Grating Vibration Sensors

Orthogonally Polarized Lasers

Synchronization in Chaotic Vertical-Cavity Surface-Emitting Semiconductor Lasers

Investigation of some critical aspects of on-line surface. measurement by a wavelength-division-multiplexing. technique

Timing Noise Measurement of High-Repetition-Rate Optical Pulses

SUPPLEMENTARY INFORMATION DOI: /NPHOTON

STABILIZED FIBER OPTIC SENSOR FOR ULTRASOUND DETECI10N

arxiv: v1 [physics.optics] 19 May 2016

Electronically tunable fabry-perot interferometers with double liquid crystal layers

Stable dual-wavelength oscillation of an erbium-doped fiber ring laser at room temperature

Cost-effective wavelength-tunable fiber laser using self-seeding Fabry-Perot laser diode

Frequency stability and reproducibility of iodine stabilised He-Ne laser at 633 nm

INTEGRATED ACOUSTO-OPTICAL HETERODYNE INTERFEROMETER FOR DISPLACEMENT AND VIBRATION MEASUREMENT

Optical Phase Lock Loop (OPLL) with Tunable Frequency Offset for Distributed Optical Sensing Applications

Results from the Stanford 10 m Sagnac interferometer

All-Optical Clock Division Using Period-one Oscillation of Optically Injected Semiconductor Laser

NEW LASER ULTRASONIC INTERFEROMETER FOR INDUSTRIAL APPLICATIONS B.Pouet and S.Breugnot Bossa Nova Technologies; Venice, CA, USA

A Fast Phase meter for Interferometric Applications with an Accuracy in the Picometer Regime

Optical Vernier Technique for Measuring the Lengths of LIGO Fabry-Perot Resonators

la. Smith and C.P. Burger Department of Mechanical Engineering Texas A&M University College Station Tx

How to Build a Gravitational Wave Detector. Sean Leavey

Wave Front Detection for Virgo

Koji Arai / Stan Whitcomb LIGO Laboratory / Caltech. LIGO-G v1

The Florida control scheme. Guido Mueller, Tom Delker, David Reitze, D. B. Tanner

Actively Stabilized Scanning Single-Frequency. Ti:Sa /Dye Ring Laser External Doubling Ring Ti:Sa /Dye Standing Wave Laser

FREQUENCY COMPARISON AT 633 NM WAVELENGTH: DETERMINATION OF DIAGONAL ELEMENTS OF MATRIX MEASUREMENTS BY USING A MASTER-SLAVE He-Ne LASER SYSTEM

Fabrication of large grating by monitoring the latent fringe pattern

OPSENS WHITE-LIGHT POLARIZATION INTERFEROMETRY TECHNOLOGY

Absolute distance interferometer in LaserTracer geometry

R. J. Jones College of Optical Sciences OPTI 511L Fall 2017

Swept Wavelength Testing:

Use of Computer Generated Holograms for Testing Aspheric Optics

Extending the Offset Frequency Range of the D2-135 Offset Phase Lock Servo by Indirect Locking

Module 5: Experimental Modal Analysis for SHM Lecture 36: Laser doppler vibrometry. The Lecture Contains: Laser Doppler Vibrometry

Sinusoidal wavelength-scanning common-path interferometer with a beam-scanning system for measurement of film thickness variations

William R. Scott, Stephen Huber*, and Martin Ryan

OPSENS WHITE-LIGHT POLARIZATION INTERFEROMETRY TECHNOLOGY

Ph 77 ADVANCED PHYSICS LABORATORY ATOMIC AND OPTICAL PHYSICS

Pound-Drever-Hall Locking of a Chip External Cavity Laser to a High-Finesse Cavity Using Vescent Photonics Lasers & Locking Electronics

PHASE TO AMPLITUDE MODULATION CONVERSION USING BRILLOUIN SELECTIVE SIDEBAND AMPLIFICATION. Steve Yao

- Near Field Scanning Optical Microscopy - Electrostatic Force Microscopy - Magnetic Force Microscopy

The Virgo detector. L. Rolland LAPP-Annecy GraSPA summer school L. Rolland GraSPA2013 Annecy le Vieux

The VIRGO injection system

Characteristics of absorption and dispersion for rubidium D 2 lines with the modulation transfer spectrum

RADIO-OVER-FIBER TRANSPORT SYSTEMS BASED ON DFB LD WITH MAIN AND 1 SIDE MODES INJECTION-LOCKED TECHNIQUE

Fiber Optic Sensing Applications Based on Optical Propagation Mode Time Delay Measurement

SENSITIVITY OF AN EMBEDDED FIBER OPTIC ULTRASOUND SENSOR

레이저의주파수안정화방법및그응용 박상언 ( 한국표준과학연구원, 길이시간센터 )

Fabry Perot Resonator (CA-1140)

Theory and Applications of Frequency Domain Laser Ultrasonics

THE TUNABLE LASER LIGHT SOURCE C-WAVE. HÜBNER Photonics Coherence Matters.

Modeling, Simulation And Implementation Of Adaptive Optical System For Laser Jitter Correction

Alignment control of GEO 600

Stabilizing an Interferometric Delay with PI Control

History of Velocimetry Technology

LIGO SURF Report: Three Input Matching/Driving System for Electro-Optic Modulators

STUDY ON SAW ATTENUATION OF PMMA USING LASER ULTRASONIC

DIRECT MODULATION WITH SIDE-MODE INJECTION IN OPTICAL CATV TRANSPORT SYSTEMS

VIRGO. The status of VIRGO. & INFN - Sezione di Roma 1. 1 / 6/ 2004 Fulvio Ricci

Photonic Microwave Harmonic Generator driven by an Optoelectronic Ring Oscillator

attosnom I: Topography and Force Images NANOSCOPY APPLICATION NOTE M06 RELATED PRODUCTS G

Simple interferometric fringe stabilization by CCD-based feedback control

Coherence length tunable semiconductor laser with optical feedback

Sensitivity evaluation of fiber optic OC-48 p-i-n transimpedance amplifier receivers using sweep-frequency modulation and intermixing diagnostics

High-resolution frequency standard at 1030 nm for Yb:YAG solid-state lasers

EE119 Introduction to Optical Engineering Fall 2009 Final Exam. Name:

Transcription:

Precision displacement measurement by active laser heterodyne interferometry Yi-Jyh Lin and Ci-Ling Pan We demonstrate an active laser heterodyne interferometer which can automatically compensate environmental disturbances and is capable of precision displacement measurement. Two Zeeman He-Ne lasers were employed. Laser II was used as the light source to stabilize the interferometer by using a piezomirror in a feedback loop. The hetereodyne signal of the two lasers was used to directly calibrate mirror displacement, with the wavelength of laser I tuned to compensate change in the interference signal due to displacement only. Separation of the contributions to the interference signal from displacement and external disturbances was accomplished by using polarization optics. This interferometer was used to measure the hysteresis of a piezoelectric transducer (PZT) over a dynamic range of 0.5 um with a resolution of 0.8 nm. Key words: Metrology, laser. I. Introduction Traditionally, precision displacement measurements were performed using fringe counting-type laser interferometers.1 If desired, dc drifts and low frequency phase noise in these interferometers could be eliminated to a large extent by employing various feedback schemes. For example, this can be achieved simply by altering the optical path length in the reference arm of a Michelson interferometer by physically moving a piezomirror. 2 Improved versions using flexure elements have also been recently demonstrated. 3 Another technique involves the use of optical fibers and compensating path length changes by straining the fiber. 4 Shajenko and Green 5 first proposed using a tunable laser for signal stabilization of optical interferometric hydrophones. This was experimentally demonstrated by Olsson et al. 6 using a dye laser with an electrooptical (EO) tuner. Employing widely tunable laser diodes as the light source, Yoshino and co-workers 7 improved fringe stability by 2 orders of magnitude and achieved displacement measurement over a dynamic range of 89 gm with a precision of 10-16 nm. In these so-called active laser interferometers, the change in the interference signal from displacement, The authors are with National Chiao Tung University, Institute of Electro-Optical Engineering, Hsinchu, Taiwan 30050, R.O.C. Received 22 May 1990. 0003-6935/91/131648-05$05.00/0. 1991 Optical Society of America. etc. was compensated by tuning the frequency of the laser. The measurement resolution was limited by the linewidth of the laser, while the laser tuning range determined the measurement range. It is not necessary to calibrate the wavelength of the tunable laser in these active interferometers if a heterodyne arrangement is employed. For example, Brillet and Hall 8 measured space anisotropy by locking a tunable laser to a cavity resonance and measuring the heterodyne beat frequency between the tunable laser and a second fixed frequency laser. The same technique was employed by Riis et al. 9 recently to calibrate the electrical response of piezoelectric elements used in scanning tunneling microscopes. Alternatively, Bjorklund et al. 10 used a FM sideband technique by locking a laser FM sideband to an interferometer resonance. In these works, extreme care was taken for environmental control. The Fabry-Perot interferometer setup used was also not suitable for general purpose displacement measurement. Previously we showed preliminary results for a Zeeman He-Ne laser-based active laser interferometer The Zeeman beat frequency of the laser varies as a function of the laser wavelength and can be calibrated such that it provides a convenient frequency marker for the laser output. 1 2 Utilizing the extreme narrow linewidth and excellent frequency stability (<1 MHz) of the laser, we were able to demonstrate fringe stabilization and precision displacement measurements with subnanometer resolution. While the single-mode tuning range of this laser is only 300 MHz, displacement measurements over many wavelengths can be obtained by adjusting the optical path length difference (OPD) 1648 APPLIED OPTICS / Vol. 30, No. 13 / 1 May 1991

H Pi I1.ti., /2 =_ -L* Zeeman He-Ne Servo Electroics Det. Fig. 1. Schematic representation of a generic active laser interferometer. of the two arms of the Michelson interferometer. One difficulty we encountered with this instrument was its extreme sensitivity to environmental disturbances, such as thermal drift, air flow, and mechanical vibrations. The laser would tune its wavelength to compensate change in the optical phase, regardless of its origin. The situation is particularly severe for an interferometer with long OPD. This is overcome to a large extent in this work by stabilizing the interferometer in a separate loop using a heterodyne technique. We present basic principles of this active laser heterodyne interferometer in Sec. II. Experimental techniques and results are presented in Secs. III and IV, respectively. Preliminary results were presented at the 1989 OSA Annual Meeting. 13 II. Basic Principles and Experimental Methods For convenience, let us consider a generic active laser interferometer using a Zeeman He-Ne laser as the light source and a Michelson interferometer as the displacement sensor (Fig. 1). The optical phase between the interfering beams of the two arms is given by OPD where X is the wavelength of the laser. A variation of the OPD or X will cause a phase change: 2ir(XAOPD - OPDAX) (2) In an active laser interferometer, the phase change is nulled by wavelength tuning of the laser such that AOPD= (OPD) AX -( OPD) Af (3) where f = c/x is the frequency of the laser. External disturbances such as air current, temperature fluctuations, etc., as well as the actual displacement xm, contribute to AOPD. In this work we are interested in the measurement of displacement for which AOPD << OPD and the use of laser sources with a tuning range Af << f. Equation (3) indicates that the range of displacement that can be measured for a given tuning range of the laser is linearly proportional to the OPD. Either subnanometer displacement or change in the OPD of Fig. 2. Block diagram of the active laser heterodyne interferometer: L1, laser I; L2, laser II; BE, beam expanders; P1 and P2, polarizers; BS, beam splitter; PBS1 and PBS2, polarizing beam splitters; D1 and D2, photodiodes; and APD, avalanche photodiode. many wavelengths can be measured by employing a laser with a sufficiently large tuning range or an appropriate choice of the OPD. The optical phase at the output of the interferometer can thus be viewed as biased by the OPD, which is the product of the index of refraction and the preset path length difference of the two arms, i.e., OPDbias = nlbias. If the environmental disturbances can be eliminated or neglected, we can write OPDbias Lbias m= 2f 2f (4) Xm= 2fAf = Af. In Eq. (4), the displacement compensation ratio Xm/Af is essentially a constant for a given Lbias. For example, this ratio is 0.11 nm/mhz for Lbia, = 10 cm. That is, a displacement of 0.11 nm would be compensated by shifting the frequency of the laser by 1 MHz. Equation (4) also shows that the transfer function for the active laser interferometer is essentially linear. The experimental arrangement of our active laser heterodyne interferometer is shown in Fig. 2. Two A ' ~~~~~~~~~~~~~~(1) Zeeman He-Ne lasersl2 4 1 5 were employed. These were stabilized by phase locking the Zeeman beat signal to an external reference clock. The error signals were fed back as a current through a heater wound around the laser tube to control its cavity length. The Allan variance' of these lasers has been measured for averaging times r between 10 ms and 100 s. It exhibits the familiar bathtub shape and the frequency stability was 3 X 10-10 for r = 0.01 s, 5 X 10-11 for r between 0.1 and 1 s, and better than 10-10 for - of the order of a few seconds. Laser II serves as the light source for an auxiliary interferometer formed by mirrors Ml and M 2 as well as beam splitter BS and polarizing beam splitter PBS1. Clearly, one arm of the auxiliary interferometer coincides with that of the main interferometer (formed by mirrors M 1, M 3, and the beam splitters). Mirrors M 2 and M 3 were carefully positioned relative to the polarizing beam splitter PBS1, such that the bias length of the other arm of the two interferometers as equal within a millimeter. The interference signals derived from these two interferometers were separated by using a 1 May 1991 / Vol. 30, No. 13 / APPLIED OPTICS 1649

pair of polarizing beam splitters and fed to detectors DI and D2, respectively. Phase sensitive detection schemes were used to extract the error signal used for feedback control. The change in the optical phase detected by D2 was nulled by using piezomirror M 1 via a servo loop to compensate the change in the OPD because of environmental disturbances as well as frequency drift or fluctuation of laser II. As a result, (a) I R LOOP OFF R Lnp ni lomhzi5nm AOPD, + AOPD _ Af 2 OPD f2 where AOPDn and AOPDC were changes in the OPD because of environmental factors and compensational displacement from piezomirror M, 2 is the output frequency of laser II, and Af 2 is its fluctuation. In the main interferometer, nulling the optical phase by wavelength tuning of laser I results in (AOPD + AOPDC) + OPD,,, OPDbias where AOPDm is the change in the OPD because of displacement of piezomirror M 3, which we wish to measure. We have also assumed that AOPDn for the two interferometers is essentially the same. If follows from Eqs. (5) and (6) that or Affl - Af 1- Af = -OPDb- AOPDm. (7a) Af/ Lbias A f -f2)- (7b) Equation (7) differs from Eq. (4) in that heterodyne frequency A(fl - f2) replaces Af. It is.no longer necessary to know the absolute frequency of either of the two lasers. The heterodyne frequency is also independent of the change in the OPD resulting from environmental disturbances. The range of A(fl - f2) is limited by the tuning range of the lasers used (300 MHz in our case). Experimentally, the heterodyne frequency of the two lasers was detected by an avalanche photodiode (APD) and extracted from the auxiliary output ports of a RF spectrum analyzer (RFSA) with sampleand-hold circuits. The access time for beat frequency measurement was 0.3 s. Frequency counters were also employed initially. In this case, broadband preamplifiers had to be used. The amplifier that was available to us generated spurious signals at the harmonic frequencies of A(fl - f2). This rendered the use of counter for signal processing impossible. It should be feasible to replace the RFSA with appropriately designed counting circuits in future experiments. Ill. Results and Discussions We have determined the measurement time constant of the interferometer to be 1.2 s from the rise time of the change in the beat signal when a step voltage was applied to PZT2. This was limited by the thermal response of the laser, but sufficiently short for our purposes. The results reported here thus represent average displacement measured over this time inter- fi (5) (6) (b) B LOOP OFF AvAvwr1Y[ U- m B LOOP ON I OMHzI 5 nm Fig. 3. (a) Residue fluctuation of the interferometer as represented by the beat frequency of the lasers with the feedback loop (B loop) for the auxiliary interferometer open or closed. (b) Same as (a) except that PBS1 was removed. (See Fig. 2 for reference.) val, i.e., -1.2 s. Figure 3(a) illustrates the measurement resolution of our interferometer for Lbia, = 140 cm, corresponding to a displacement compensation ratio Xm/lAf = 1.48 nm/mhz. With feedback loop B for the auxiliary interferometer closed, the residue fluctuation in the OPD of the interferometer was less than +0.8 nm. Part of this residue error was attributed to the fact that, while the optical paths in the two interferometers were essentially the same, they were not identical. To check, we did the following experiment. The two arms of the main interferometer were BS-Ml and BS-PBS1-M3, while those of the auxiliary interferometer were BS-M1 and BS-PBS1-M2, respectively (see Fig. 2). By removing PBS1, we could render the arms of the two interferometers exactly the same. In so doing, the residue noise reduced to 0.4 nm [Fig. 3(b)]. It is not essential to use a frequency stabilized laser as the light source, laser II, in the auxiliary interferometer. Piezoelectric transducer PZT1 can, in principle, be used to compensate frequency drift of laser II also. Experimental verification of the above statement is shown in Fig. 4. The hysteresis of PZT2, which displaces mirror M3, measured by our apparatus is shown in Fig. 5. The specification of the PZT was 3,m/1 kv. From our data it was determined that this ratio was 3.7 ± 0.8 nm/v. We note that the data points on the hysteresis loop were repeatable if we cycled the voltage applied to the PZT. We now address the question of the error in the measurement of displacement employing our interferometer. Using Eq. (7), we can show that 1650 APPLIED OPTICS / Vol. 30, No. 13 / 1 May 1991

I L Z m~ 1 B LOOP OFF 1 B LOOP ON k^+* 1OMHz15 nm 1 min Fig. 4. Residue fluctuation of the interferometer as represented by the beat frequency of the lasers with the feedback loop (B loop) for the auxiliary interferometer open or closed. Laser III was freeruning. I co U- t -60-30 0-30 60 PZT voltage Fig. 5. Beat frequency as a function of the dc voltage applied to the piezoelectric transducer PZT2. The displacement was calculated using Eq. (7). (AXm) 2 (xm AK) 2 + (Kf 1 2) 2 (8) where Axm, AK, and Afl_ 2 are, respectively, the rms error in displacement xm, displacement compensation ratio K = -Xm/A(f - f2) = -Lbias/2f1, and the beat frequency of the two lasers A(f 1 - f2). The first term on the right-hand side of Eq. (8) represents the accuracy in the measured value of the displacement, while the second term determined the minimum displacement that can be measured. Since the frequency stability of our lasers was better than 10-9, AK is dominated by ALbias only, i.e., AK/K ALbias/Lbias. As an example, if Lbi = 140 cm, ALbias = 2 mm, K = 1.48 nm/mhz, Afi 2 = 0.5 MHz, and xm = 500 nm, we find that the accuracy of the measured value of the displacement is better than 0.15% and the resolution is -0.5 nm. As a result, total error Axm 1 nm. Thus, measurement with a 0 'a U1 3 dynamic range of -0.5 Am with a combined error of 1 nm is possible with the present experimental arrangement. This is consistent with the data shown in Figs. 3 and 5. In our interferometer, separation of the contributions to the interference signal because of displacement and external disturbances was accomplished by using polarization optics. We then expect that polarization leakage from a nonideal PBS would adversely affect the interferometer. Let the optical field amplitude incident on mirrors MI and M2 be Al and A 2, respectively. We have shown that Eq. (7b) should be modified as 16 Lba Xm = -1 2' 2f 1 A(1-2), where x = 1 A, cos 27r 1, Lbias and A 2 << A 1. Because of the presence of polarization leakage, displacement xm is no longer linearly proportional to A(f 1 - f2). Instead, it is modulated with a period of X 1 /2 and peak-to-peak variation of 2(A 2 /Al). The measurement resolution of the interferometer as expressed in Eq. (8) is affected in that the factor AK/K is modified: (AK/K) 2 = (n/n) 2 + (ALbas 5 /Lbias) 2. We require that Aql/q1 < 1/2(Lbas 5 /Lbas). The extinction ratio of the PBS used should then be better than 7 X 10-4 for Lbias = 140 cm and ALbias = 2 mm. Finally, we note that the present interferometer can be used for tilt angle measurement of a reference plane. For this application, PBS1, M 2, and M 3 in Fig. 2 are replaced by the arrangement shown in Fig. 6. The orthogonally polarized beams from the two lasers are separated spatially by a distance D. By displacing the PZT, tilt angle 0 is given by the ratio xm/d. With D 4 mm and Axm = +0.4 mm, the angular resolution AO 1 X 10-7 rad. IV. Conclusion The basis concepts and experimental realization of an active laser heterodyne interferometer have been presented. The advantage of the conventional active interferometer is retained: displacement is obtained directly from frequency shift of the laser without postdetection processing. In our interferometer it is, however, not necessary to know the absolute frequency of the lasers because of the heterodyne arrangement used. Our interferometer is also relatively insensitive (2) PBS \ ( I Fig. 6. Setup for the proposed method for tilt angle measurement with the present interferometer. Here, L 1 and L 2 are collinear orthogonally polarized beams from lasers I and II. Li, L 2 - l - J D D - I IXm PZT 1 May 1991 / Vol. 30, No. 13 / APPLIED OPTICS 1651

to environmental disturbances by using a novel design with main and auxiliary interferometers. To demonstrate its capabilities, we measured the displacement of a PZT over a range of -0.5,gm with a resolution of 10.8,gm. A hysteresis loop of the PZT was observed which remained closed after repeated cycling. Displacement measurement over a range of many wavelengths or subnanometers in length should be possible with judicious choice of Lbias and narrow linewidth tunable lasers. This work was partially supported by the National Science Council and the Industrial Technology Research Institute of the Republic of China. References 1. See, for example, H. J. Tiziani, "Optical Methods for Precision Measurements," Opt. Quantum Electron. 21, 253-282 (1989) and references therein. 2. C. H. Palmer and R. E. Green, "Materials Evaluation by Optical Detection of Acoustic Emission Signals," Mater. Eval. 35, 100-106 (1977). 3. R. G. White and D. C. Emmony, "Active Feedback Stabilisation of a Michelson Interferometer Using a Flexure Element," J. Phys. E 18, 658-663 (1985). 4. K. Fritsch and G. Adamovsky, "Simple Circuit for Feedback Stabilization of a Single Mode Fibre Interferometer," Rev. Sci. Instrum. 52, 996-1000 (1981). 5. P. Shajenko and E. L. Green, "Signal Stabilization of Optical Interferometric Hydrophones by Tuning of the Light Source," Appl. Opt. 19, 1895-1897 (1980). 6. A. Olsson, C. L. Tang, and E. L. Green, "Active Stabilization of a Michelson Interferometer by an Electrooptically Tuned Laser," Appl. Opt. 19, 1897-1899 (1980). 7. T. Yoshino, M. Nara, S. Mnatzakanian, B. S. Lee, and T. C. Strand, "Laser Diode Feedback Interferometer for Stabilization and Displacement Measurements," Appl. Opt. 26, 892-897 (1987). 8. A. Brillet and J. L. Hall, "Improved Laser Test of the Isotropy of Space," Phys. Rev. Lett. 42, 549-552 (1979). 9. E. Riis, H. Simonsen, T. Worm, U. Nieisen, and F. Besenbacher, "Calibration of Piezoelectric Elements at Low Voltage Using Laser Interferometry," Appl. Phys. Lett. 54, 2530-2531 (1989). 10. G. C. Bjorklund, K. Jain, J. D. Hope, "Interferometric Measurements with Laser FM Sidebands," Appl. Phys. Lett. 38,747-749 (1981). 11. Ci-Ling Pan, "Zeeman Laser-Based Active Laser Interferometer," in Technical Digest, Annual Meeting of the Optical Society of America (Optical Society of America, Washington, DC, 1988), paper MGG3. 12. T. Baer, F. V. Kowalski, and J. L. Hall, "Frequency Stabilization of a 0.633-,um He-Ne Longitudinal Zeeman Laser," Appl. Opt. 19, 3173-3177 (1980). 13. Ci-Ling Pan and Y. T. Lin, "Improved Active Laser Interferometer with Automatic Compensation," in Technical Digest, Annual Meeting of the Optical Society of America (Optical Society of America, Washington, DC, 1989), paper THS6. 14. Ci-Ling Pan and P.-Y. Jean, "Simultaneous Output Power and Frequency Stabilization of a Zeeman He-Ne Laser," Appl. Opt. 25, 1375-1376 (1986). 15. Yi-Jyh Lin, "The Study of an Active Interferometer," M. S. Thesis, National Chiao Tung University, Hsinchu, Taiwan, 1989. 16. D. W. Allan, "Statistics of Atomic Frequency Standards," Proc. IEEE 54, 221-230 (1966). 1652 APPLIED OPTICS / Vol. 30, No. 13 / 1 May 1991