PLE 2CS Plena Two-zone Call Station

Similar documents
LBC 3201/00 Line Array Indoor Loudspeaker

LBC 3200/00 Line Array Indoor Loudspeaker

Bosch Plena Public Address Solutions A flexible approach to sound management

Vari directional Array

Amplifiers and battery charger

PRS xpxxx and LBB 4428/00 Power Amplifiers

PLENA SOLUTIONS F E A T U R E S PUBLIC ADDRESS GUIDE

BS 17 SINGLE CHANNEL BELTPACK. User Manual. January 2017 V1.0

PA0688 Microphone Pre-Amplifier Module

TOA NEW 900 SERIES MIXER PREAMPLIFIER M-900A

PS 19 AM SINGLE CHANNEL BELTPACK IN METAL CASE WITH PGM (AUX) INPUT

LBC 34xx/12 Horn Loudspeakers

Dante Kit MEB 114-S. Thanks to its rugged housing and its high-quality microphone capsule the MEB 114-S ensures the best speech intelligibility.

Bosch Communications Systems Get your message across, effectively.

EVID Surface Mount S Series - X Models

XLA 3200 Line Array Loudspeakers

The ME 36 is a condenser microphone capsule. This mini shotgun microphone features for an outstanding background noise rejection.

Dante Kit MEG FEATURES DELIVERY INCLUDES PRODUCT VARIANTS

Dante Kit MEG basic

USER MANUAL QSM-606AZ QSM-612AZ QSM-624AZ MIXER AMPLIFIER

TOA 900 SERIES POWER AMPLIFIER P-924A

SA 125 mixer amplifier. user manual

TOA 500 SERIES MIXER POWER AMPLIFIER

User Manual TUBE CONDENSER MICROPHONE T-1. Vacuum Tube Condenser Microphone

Q-Tech. Q-Tech Commercial Series QTA 1360P/1480P Power Amplifiers. User Manual

LBC 3253/xx Intellivox 2c Active Line Array Loudspeakers

Integrated mixer amplifier PA-60/120/240

TOA NEW 900 SERIES MIXER POWER AMPLIFIER A-901A. General Description. TOA Corporation. Operation Instruction Manual

OPERATING INSTRUCTIONS. VHF Transceiver AR Subject to technical changes

ELECTRONIC COMPONENTS LP4 32 USER MANUAL

AC/DC Clamp Meter. Owner's Manual. Model No Safety Operation Maintenance Español

mix 502, mix 802, mix 1202FX mixer user manual

LBC 3201/00 Line Array Indoor Loudspeaker

Application overview. Commercial Audio Solutions. boschsecurity.com

Operating Instruction Manual ELECTRONIC MUSIC AMPLIFICATION SYSTEM. Model KD-1. Toa Electric Co., Ltd. KOBE, JAPAN

LBC 3252/xx Intellivox 2b Active Line Array Loudspeakers

PM7400MKII. Instruction manual

INSTRUCTION MANUAL FM HANDHELD TRANSCEIVER

AUTOMATIC MIXER AX-1OOOA

ZM 84 Audio Mixer. User Manual. Order code: CRAM41. Audio Mixer ZM 84 AUX 3 AUX 1 AUX 2 AUX 4 MASTER 1 MASTER 2 OFF BASS BASS TREBLE TREBLE BASS BASS

User Manual. MA 240 Mixing amplifier

TM-800 Main Station. Instruction Manual. TELIKOU Systems All Rights Reserved

Q-Tech Commercial Series. 86 Derby St. Pascoe Vale VIC 3055 ( : *

Making Your Tour. State of the Art. TourGuide 2020-D

SL TS 133 GN Set DW FEATURES

Achat 212 H passive subwoofer. user manual

FreeSpace DS 16F VA TECHNICAL DATA SHEET. loudspeaker. Key Features. Product Overview. Technical Specifications

LBC3200/00 Line array loudspeaker, 30W

SpeechLine Digital Wireless SL TS 133 GN Set DW

Overview. Features. Technical Data Sheet 1 / 5. Power Amplifier XMV8140-D

CommCenter Digital Message Center

Instruction Kit MIXER AMPLIFIER GT 60C GT 125C. GROMMES-PRECISION SINCE-46

DPAfour125, DPAfour250 AMPLIFIERS. Operating Manual

SpeechLine Digital Wireless SL TS 153 GN-L Set DW

User Manual VOLUME PTT 1 MIC/LINE 2 MIC/LINE 3 MIC/LINE 4 MIC/LINE 5 MIC/LINE 6 MIC/LINE 7 MIC/LINE 8 MIC/LINE 9 MIC/LINE 10 LEVEL LEVEL TREBLE 6 MIC

Model WM1000/WM2000. Wall Mount Intercom Stations. User Instructions

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information

OWNER S MANUAL FM HANDHELD TRANSCEIVER

PS 260T DUAL CHANNEL AUDIO INTERFACE USER MANUAL

PERMA Series Revision 2 Amplifiers

SL TS 153 GN-L Set DW

evolution wireless G4 ew 300 G4-HEADMIC1-RC Bodypack Headmic Set

TOA NEW 900 SERIES POWER AMPLIFIER

SPA2060, SPA2120, SPA2240 amplifier. User Manual

Ver Tornado KT2 - KT2C KTL2 - KTL2C. USER GUIDE English KT2 KTL2 KT2C KTL2C

User Manual. MA 21 Two zone mixing amplifier

PowerShare PS604A adaptable power amplifier

D3400 digital power amplifier. user manual

USER GUIDE English. Tornado KT2 - KT2-HV KT2C - KT2C-HV KTL2 - KTL2-HV KTL2C - KTL2C-HV KT2 - KT2-HV KTL2 - KTL2-HV KT2C - KT2C-HV KTL2C - KTL2C-HV

L1 Model 1S TECHNICAL DATA SHEET. portable line array system. Key Features. Product Overview. Technical Specifications

User s Guide. 400A AC/DC Clamp Meter. Model MA Washington Street Melrose, MA Phone Toll Free

Trace Elliot Elf Bass Instrument Amplifier

SETUP and OPERATING MANUAL ADVANCED MULTI-CHANNEL VEHICLE INTERCOM SYSTEM (AMCVIS)

USER MANUAL VIVALDI MZ550A. Distribution Mixer Amplifier

TA 450 MK-X TA 600 MK-X TA 1050 MK-X TA 1400 MK-X TA 2400 MK-X power amplifier. user manual

SHURE INCORPORATED KSM109 CARDIOID CONDENSER MICROPHONE. Thank you for selecting the KSM109

L1 Model I TECHNICAL DATA SHEET. portable line array system. AV-Concept - tlf web: Key Features.

KWM Quartet Wireless microphone system

ALM473 DUAL MONO \ STEREO AUDIO LEVEL MASTER OPERATION MANUAL IB

SQN Electronics Ltd. SQN-4S Series IVe Miniature 4:2 Sound Mixer The original broadcast quality stereo portable mixer for TV, film and radio locations

Model 7000 Low Noise Differential Preamplifier

EVID High Performance Ceiling Speakers

Professional UHF Rechargeable Wireless Microphone System POWER ON/OFF BATTERY CHARGE. Green Light (Full) Better Music Builder DOWN VOLUME

HARMONY SINGER 2. Battery-Powered Vocal Effects Stompbox with Guitar-Controlled Harmony, Reverb and Tone. User Manual

E-400 endstufe. user manual

PLA-240. Small Room Loop Amplifier System. USER Manual MAN 211A

plifier D-501 otion Am Tactile M

Bedienungsanleitung Instructions for use Notice d emploi Istruzoni per l uso Instrucciones de uso Gebruiksaanwijzing 912 S

EC Declaration of Conformity

Power quality Harmonics up to 40th harmonic Unbalance, rotary field indication Distortion factor THD-U / THD-I

Block-800B bass head. user manual

Passive Loudspeaker Owner s Manual

Model 1791 VHF Radio User's Manual

MediaMatrix X-Frame 88

INSTALLATION AND OPERATION MANUAL IODA INPUT/OUTPUT MULTI-FUNCTION BOARD (Part No. 9668)

Portable Multi-Channel Recorder Model DAS240-BAT

User's Manual PS 2/2A LTO R. Version 1.1 Septemper 2005 English

MA V 35W Mixer Amplifier

Model 526T Series II Super Punch Microphone User Guide

IMPORTANT SAFETY INSTRUCTIONS

Transcription:

Communications Systems PLE 2CS Plena Two-zone Call Station PLE 2CS Plena Two-zone Call Station Modern two-zone call station for the PLE series Selectable gain Speech filter and limiter Output level control Loop-through option for up to 8 call stations LED indications for zone selection, busy, and power on The Plena two-zone call station is a modern, high-quality call station with a stable metal base design, a flexible microphone stem and a unidirectional condenser microphone. It can make calls to selected zones in a public address system built with the PLE series two-zone mixer and mixer amplifiers. In addition to tabletop use, the Plena design allows neat flush-mounting in desktops. Functions Gain, speech filter and intelligibility This call station features selectable gain, a selectable speech filter, and a limiter for improved intelligibility. Range The call station has a balanced line level output, giving it a maximum range of 200 meters from the mixer, when using CAT-5 extension cables. Loop-through With the loop-through RJ-45 connector, it is possible to daisy chain multiple call stations. Priority The priority is automatic i.e. the call station nearest the mixer has priority and can override a call station further from the mixer. When a call is being made by a higher priority call station, a yellow light will display on the lower priority call stations. Dip switches and status DIP switches at the base of the call station select different microphone gain levels, chimes, and the speech filter. A service accessible rotary control provides microphone level attenuation. LEDs on the call station show which zones have been selected. An additional LED give visible feedback on the active state of the microphone and the system: Green flashing means standby (chime is sounding) Green indicates microphone active Amber indicates a higher priority call Controls and indicators 2 x status LEDs PTT key 2 x zone selection keys 2 x zone selection LEDs DIP switches Rotary volume control Interconnections 2 x RJ45 jacks Certifications and Approvals Region Europe Certification CE www.boschsecurity.com

2 PLE 2CS Plena Two-zone Call Station Safety acc. to EN 60065 Immunity acc. to EN 55103-2 Emission acc. to EN 55103-1 Environmental Operating temperature -10 ºC to +45 ºC (14 ºF to +113 ºF) Storage temperature -40 ºC to +70 ºC (-40 ºF to +158 ºF) Relative humidity <95% Parts Included Quantity Components 1 PLE-2CS Plena two-zone call station 1 Cable terminated with a lockable CAT-5 connector Ordering Information PLE 2CS Plena Two-zone Call Station metal base design, a flexible microphone stem with a unidirectional condenser microphone and zone selection PLE-2CS Technical Specifications Electrical Voltage range Current consumption Performance Nominal sensitivity Nominal output level Input sound level (max) Gain preset Limiter threshold 24 VDC supplied by PLE mixer amplifier or mixer <30 ma 85 db SPL (gain preset 0 db) 700 mv 110 db SPL -15 / 0 / +6 db 2 V Compression ratio limiter 1:20 Distortion Input noise level (equiv.) Frequency response Speech filter Output impedance Selections Chimes 6 Mechanical Base dimensions (H x W x D) without microphone Stem length with microphone Cable length Weight Mounting Color <0.6% (maximum input) 25 db SPLA 100 Hz to 16 khz -3 db at 315 Hz, high-pass, 6 db/oct 200 ohm 40 x 100 x 235 mm (1.57 x 3.97 x 9.25 in) 390 mm (15.35 in) 5 m (16.4 ft) Approx. 1 kg (2.2 lb) Standalone Charcoal with silver Americas: Bosch Communications Systems 12000 Portland Avenue South Burnsville, Minnesota 55337, USA Phone: +1-800-392-3497 Fax: +1-800-955-6831 audiosupport@us.bosch.com www.boschsecurity.com Europe, Middle East, Africa: Bosch Security Systems B.V. P.O. Box 80002 5600 JB Eindhoven, The Netherlands Phone: + 31 40 2577 284 Fax: +31 40 2577 330 emea.securitysystems@bosch.com www.boschsecurity.com Asia-Pacific: Robert Bosch (SEA) Pte Ltd 11 Bishan Street 21 Singapore 573943 Phone: +65 6571 2600 Fax: +65 6571 2698 apr.securitysystems@bosch.com www.boschsecurity.com Represented by Bosch Security Systems Inc. 011 Data subject to change without notice T4227052683 Cur: en-us, V19, 27 Jan 2011

Plena Two-zone Call Station en Installation and User Instructions PLE-2CS

Plena Two-zone Call Station Installation and User Instructions Important safeguards en 2 Important safeguards Before installing or operating this product, always read the Safety Instructions, which are available as a separate document (9922 141 7014x). These instructions are supplied together with all equipment that can be connected to the mains. Thank you for choosing a Bosch Security Systems product!

Plena Two-zone Call Station Installation and User Instructions Table of contents en 3 Table of contents Important safeguards...2 Table of contents...3 1. Introduction...5 1.1 Purpose...5 1.2 Digital document...5 1.3 Intended audience...5 1.4 Related documentation...5 1.5 Alerts...5 1.6 Icons...5 1.6.1 Note icons...5 1.6.2 Caution, Warning, and Danger icons...5 1.7 Conversion tables...6 2. Description...7 2.1 The Plena product range...7 2.2 Contents of box...7 2.3 The Plena Two-zone Call Station...7 2.3.1 Balanced line level output...7 2.3.2 Loop-through RJ-45 sockets...7 2.3.3 DIP switches and status LEDs...7 2.3.4 PTT button...7 2.4 Controls, connectors and indicators...8 2.4.1 Top side...8 2.4.2 Bottom side...8 3. Installation...9 3.1 Unpack unit...9 3.2 Connect unit to PLE-series two-zone mixer (amplifier)...9 3.3 Make configuration settings...9 4. Connections and settings... 11 4.1 Connecting multiple call stations... 11 4.2 Configuration settings... 11 4.2.1 Chime settings... 11 4.2.2 Momentary or latching speaking setting... 11 4.2.3 Speech filter setting... 11 4.2.4 Microphone gain settings... 12 5. Operation... 13 5.1 Make calls (momentary speaking function)... 13 5.2 Make calls (latching speaking function)... 13 5.3 Adjust the call station output volume... 13 6. Technical data... 15 6.1 Electrical... 15 6.2 Performance... 15 6.3 Interconnection... 15 6.4 Mechanical... 15 6.5 Environmental conditions... 15 6.6 Certifications and Approvals... 15

Plena Two-zone Call Station Installation and User Instructions Table of contents en 4 Intentionally left blank

Plena Two-zone Call Station Installation and User Instructions Introduction en 5 1 Introduction 1.1 Purpose The purpose of these Installation and User Instructions is to provide information that is required to install, configure and operate a Plena Two-zone Call Station. 1.2 Digital document These Installation and User Instructions are also available as a digital document in the Adobe Portable Document Format (PDF). All references to pages, figures, tables, etc. in this digital document contain hyperlinks to the referenced location. 1.3 Intended audience These Installation and User Instructions are intended for installers and users of a Plena Two-zone Call Station. 1.4 Related documentation Safety Instructions (9922 141 ****). 1.5 Alerts Four types of alerts are used in this manual. The alert type is closely related to the effect that may be caused if it is not observed. These alerts - from least severe effect to most severe effect - are: Note Alert containing additional information. Usually, not observing a note alert does not result in damage to the equipment or personal injuries. Caution The equipment can be damaged if the alert is not observed. Warning Persons can be (severely) injured, or the equipment can be seriously damaged, if the alert is not observed. Danger Not observing the alert can result in death. 1.6 Icons 1.6.1 Note icons The icons used in combination with Notes provide extra information about the Note. See the following examples: Note General icon for notes. Note Consult the indicated source of information. 1.6.2 Caution, Warning, and Danger icons The icons used in combination with Caution, Warnings, and Dangers indicate the type of hazard present. See the following examples: Caution, Warning, Danger General icon for Cautions, Warnings and Dangers. Caution, Warning, Danger Icon for risk of electric shock. Caution, Warning, Danger Icon for risk of electrostatic discharge.

Plena Two-zone Call Station Installation and User Instructions Introduction en 6 1.7 Conversion tables In this manual, SI units are used to express lengths, masses, temperatures etc. These can be converted to non-metric units using the following information. table 1.1: Conversion of units of length 1 in = 25.4 mm 1 mm = 0.03937 in 1 in = 2.54 cm 1 cm = 0.3937 in 1 ft = 0.3048 m 1 m = 3.281 ft 1 mi = 1.609 km 1 km = 0.622 mi table 1.2: Conversion of units of mass 1 lb = 0.4536 kg 1 kg = 2,2046 lb table 1.3: Conversion of units of pressure 1 psi = 68.95 hpa 1 hpa = 0.0145 psi Note 1 hpa = 1 mbar. table 1.4: Conversion of units of temperature F 9 5 = -- C + 32 C = -- ( F 32) 5 9

Plena Two-zone Call Station Installation and User Instructions Description en 7 2 Description 2.1 The Plena product range The Plena Two-zone Call Station is part of the Plena product range. Plena provides public address solutions for places where people gather to work, worship, trade, or relax. It is a family of system elements that are combined to create public address systems tailored for virtually any application The Plena product range includes: mixers mixer amplifiers preamplifiers power amplifiers a music source unit a digital message manager a feedback suppressor call stations an All-in-One system a voice alarm system a timer a charger a loop amplifier The various elements are designed to complement each other thanks to matched acoustical, electrical and mechanical specifications. 2.2 Contents of box The packaging box contains the following: PLE-2CS Plena Two-zone Call Station Cable terminated with a lockable Cat-5 connector 2.3 The Plena Two-zone Call Station The Plena Two-zone Call Station is a modern, highquality call station with a stable metal base design, a flexible microphone stem and a unidirectional condenser microphone. It can make calls to selected zones (zone one or two) in a public address system built with the PLE-series two-zone mixer and mixer amplifiers. In addition to tabletop use, the Plena design allows neat flush-mounting in desktops. The Plena Two-zone Call Station features: a selectable microphone gain level, a selectable speech filter, and a limiter for improved intelligibility a balanced line level output. See section 2.3.1. two loop-through RJ-45 sockets. See section 2.3.2. DIP switches and status LEDs. See section 2.3.3. a push-to-talk (PTT) button. See section 2.3.4. For a detailed description of all controls, connections and indicators, see section 2.4. 2.3.1 Balanced line level output The Plena Two-zone Call Station has a balanced line level output, giving it a maximum range of 200 m from the controller when using Cat-5 Ethernet cables. 2.3.2 Loop-through RJ-45 sockets With the loop-through RJ-45 sockets, it is possible to daisy chain up to six call stations. The priority is automatic; the call station nearest to the mixer has priority and can override the call station further away from the mixer. 2.3.3 DIP switches and status LEDs With the DIP switches at the base of the call station you can select different microphone gain levels, seven different chimes (any.wav file), define the speech filter and the momentary or latching speaking functions. Two LEDs on top of the call station show which zones have been selected. One additional LED gives visible feedback on the active state of the microphone and the system: green flashing: microphone is standby (chime is sounding) green continuous: microphone is active off: a call is being made by a higher priority call station 2.3.4 PTT button To the PTT button, a pre- and post chime can be assigned that is played at the start or at the end of the call. To this end, the call station is equipped with seven built-in chimes.

Plena Two-zone Call Station Installation and User Instructions Description en 8 2.4 Controls, connectors and indicators 2.4.1 Top side See figure 2.1 for an overview of the controls and indicators on the top side of the call station: 1 Zone selection buttons - Two buttons to select the zones to which the business call is distributed. Each button has a green LED, which indicates the zone to which the business call is distributed. 2 Push-to-talk (PTT) button - A push-to-talk (PTT) button to start the business call. 3 Status indicator - A LEDs that indicates the status of the call station. See section 2.3.3. 2.4.2 Bottom side See figure 2.2 for an overview of the controls and indicators at the bottom of the call station: 1 Configuration settings - A set of DIP switches to configure the call station (by setting the microphone gain level, the chime and the speech filter). See section 4.2. 2 System sockets - Two redundant RJ-45 sockets to connect the call station to the PLE-series two-zone mixer or mixer amplifiers using Cat-5 Ethernet cables. When the system requires more than 2 call stations, the system sockets can be used to make loop-throughs. See section 4.1. 3 Rotary volume control - A rotary volume control (potentiometer) to set the output volume of the call station. See chapter 5.3. Plena 2 1 3 3 figure 2.1: Top view 2 1 2 3 4 5 6 7 8 ON 1 figure 2.2: Bottom view

Plena Plena Two-zone Call Station Installation and User Instructions Installation en 9 3 Installation 3.1 Unpack unit 1 Remove the unit from the box, and discard the packaging material according to local regulations. 2 Use your fingernails to carefully peel off the protective plastic film. Do not use sharp or pointed objects. 3.2 Connect unit to PLE-series two-zone mixer (amplifier) 1 Connect the Plena Two-zone Call Station to the PLE-series two-zone mixer or mixer amplifier using a Cat-5 Ethernet cable (see figure 3.1). Either one of the RJ-45 sockets can be used. Plena figure 3.1: Connecting the call station to the mixer or the mixer amplifier 3.3 Make configuration settings 1 Make the configuration settings (see section 4.2).

Plena Two-zone Call Station Installation and User Instructions Installation en 10 Intentionally left blank

Plena Plena Two-zone Call Station Installation and User Instructions Connections en 11 4 Connections and settings 4.1 Connecting multiple call stations When the configuration requires more than one call station, use the loop-through RJ-45 sockets on the call stations to make loop-throughs. Note In such a daisy chain configuration the priority is automatic; the call station nearest to the mixer has priority and can override the call station further away from the mixer. Call station number 2 has priority over call station number 3, etc. See figure 4.1. Plena 4.2 Configuration settings Use the DIP switches at the bottom of the call station to set the chime, the momentary or latching speaking function, the speech filter and the microphone gain. See figure 4.2. 4.2.1 Chime settings See figure 4.2. DIP switches number 1, 2 and 3 are used for setting the chime. 1 = ON-position, 0 = OFF-position. table 4.1: Chime settings DIP switch setting Description (1-2-3) 0-0-0 no chime 0-0-1 1-tone chime 0-1-0 2-tone chime 0-1-1 2-tone chime reversed 1-0-1 3-tone chime A 1-0-0 3-tone chime reversed B 1-1-0 4-tone chime A 1-1-1 4-tone chime C Plena Plena Plena 4.2.2 Momentary or latching speaking setting See figure 4.2. DIP switch number 4 is used for setting the momentary or latching speaking function. 1 = latching, 0 = momentary. 4.2.3 Speech filter setting See figure 4.2. DIP switch number 5 is used for setting the speech filter ON (1) of OFF (0). Plena figure 4.1: Connecting multiple call stations

ON Plena Two-zone Call Station Installation and User Instructions Connections en 12 4.2.4 Microphone gain settings See figure 4.2. DIP switches number 6 and 7 are used for setting the microphone gain. 1 = ON-position, 0 = OFF-position. table 4.2: Microphone gain settings DIP switch setting Description (6-7) 0-0 -15 db 1-0 0 db 0-1 +6 db 1-1 +6 db 1 2 3 4 5 6 7 8 ON(1) DIP OFF(0) 1 2 3 4 5 6 7 8(spare) figure 4.2: DIP switches

Plena Two-zone Call Station Installation and User Instructions Operation en 13 5 Operation 5.1 Make calls (momentary speaking function) 1 Press the push-to-talk button and keep the button depressed during the business call. 2 Make the business call. 3 Release the push-to-talk button after the business call. 5.2 Make calls (latching speaking function) 1 Shortly press the push-to-talk button to start the business call. 2 Make the business call. 3 Shortly press the push-to-talk button to stop the business call. figure 5.1: Adjust the output volume 5.3 Adjust the call station output volume 1 Use a screw driver to adjust the output volume of the call station. Turn clockwise to increase the output volume or turn counterclockwise to decrease the output volume. See figure 5.1. Caution Be careful not to damage the printed circuit board located directly underneath the orifice. Use a small screw driver, preferably a plastic one.

Plena Two-zone Call Station Installation and User Instructions Operation en 14 Intentionally left blank

Plena Two-zone Call Station Installation and User Instructions Technical data en 15 6 Technical data 6.1 Electrical Voltage range: 24 V(DC), supplied by PLE-series mixer or mixer amplifier. Current consumption: < 30 ma 6.2 Performance Nominal sensitivity: 85 db SPL (gain preset 0 db) Nominal output level: 700 mv Maximum input sound level: 110 db SPL Gain preset: -15 / 0 / +6 db Limiter threshold: 2V Compression ratio limiter: 1:20 Distortion: < 0.6% (maximum input) Equivalent input noise level: 25 db SPL(A) Frequency response: 100 Hz - 16 khz Speech filter: - 3 db @ 315 Hz, high-pass, 6 db/oct Output impedance: 200 Ω 6.3 Interconnection Type: 2x redundant RJ-45 sockets for daisy chaining multiple call stations. 6.4 Mechanical Base dimensions (H x W x D), without microphone: 40 x 100 x 235 mm (1.57 x 3.97 x 9.25 in) Stem length (with microphone): 390 mm (15.35 in) Cat-5 extension cable length: 5m (16.4 ft) Weight: Approx. 1 kg (2.2 lb) Mounting: Standalone Color: Charcoal with silver 6.5 Environmental conditions Operating temperature range: -10 C to +55 C (+14 F to +131 F) Storage temperature range: -40 C to +70 C (-40 F to +158 F) Relative humidity: < 95% 6.6 Certifications and Approvals Safety: According to EN 60065 EMC immunity: According to EN 55103-2 EMC emission: According to EN 55103-1

Plena Two-zone Call Station Installation and User Instructions Technical data en 16 Intentionally left blank

For more information visit www.boschsecuritysystems.com Bosch Security Systems B.V. Data subject to change without notice 2008-01 PLE-2CS en