ABB NEW. Multifunctional three-phase monitoring relays. CM-MPS.23 and CM-MPS.43 Data sheet. Features J. Approvals. Marks.

Similar documents
CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. UL 508, CAN/CSA C22.2 No.14 GL GOST CB scheme CCC

ABB NEW. Three-phase monitoring relays. CM-PVS.31 and CM-PVS.41 Data sheet. Features J. Approvals. Marks. Order data. Order data - Accessories

Three-phase monitoring relays

ABB 1. Multifunctional three-phase monitoring relays. CM-MPN.52, CM-MPN.62 and CM-MPN.72 Data sheet. Features. Approvals. Marks.

ABB 1. Multifunctional three-phase monitoring relays. CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. Features. Approvals. Marks.

Multifunctional three-phase monitoring relays CM-MPS CM-MPS.23 and CM-MPS.43

Multifunctional three-phase monitoring relays CM-MPS CM-MPS.23

Three-phase monitoring relays CM-PVS CM-PVS.31, CM-PVS.41 and CM-PVS.81

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet

Multifunctional three-phase monitoring relays CM-MPN CM-MPN.52, CM-MPN.62 and CM-MPN.72

Three-phase monitoring relay

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC

Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents

Electronic timer CT-SDS.22

Electronic timer CT-SDD.22

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Three-phase monitoring relays CM-PVS.81

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Current monitoring relays CM-SRS.1 for single-phase AC/DC currents

Voltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages

Electronic timer CT-TGD.22

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41

Current monitoring relays CM-SRS.2 For single-phase AC/DC currents

Three-phase monitoring relay

Current monitoring relays CM-SRS.1 For single-phase AC/DC currents

Three-phase monitoring relay CM-PFS

Three-phase monitoring relay CM-PBE

Three-phase monitoring relay CM-PVE

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Three-phase monitoring relays CM-PFE and CM-PFE.2

Three-phase monitoring relays Product group picture

Current monitoring relays CM-SRS.M1 For single-phase AC/DC currents

Electronic timer CT-MFS.21

Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact

Electronic timer CT-MVS.12 Multifunctional with 1 c/o (SPDT) contact

Three-phase monitoring relays Product group picture

Electronic timer CT-WBS.22 Impulse generating and flashing with 2 c/o (SPDT) contacts

Three-phase monitoring relays Table of contents

Electronic timer CT-YDE Star-delta change-over with 1 c/o (SPDT) contact

Electronic timer CT-MXS.22 Multifunctional with 2 c/o (SPDT) contacts

Electronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts

Insulation monitoring relay CM-IWN.5 For unearthed AC, DC and mixed AC/DC systems up to U n = 400 V AC and 600 V DC

Liquid level monitoring relay CM-ENS.2x

Electronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts

Electronic timer CT-EBE Flasher starting with OFF, 1 c/o (SPDT) contact

Electronic timer CT-ERS ON-delayed with 2 c/o contacts Data sheet

Electronic timer CT-MFS.21 Multifunctional with 2 c/o (SPDT) contacts

Electronic timer CT-MFS.21 Multifunctional with 2 c/o (SPDT) contacts

Control module CP-A CM

Electronic timer CT-SDE Star-delta change-over with 1 n/c + 1 n/o contact

Electronic timer CT-MBS.22 Multifunctional with 2 c/o (SPDT) contacts

Electronic timer CT-AWS Impulse-OFF with 1 c/o contact Data sheet

Power supply CP-E 24/0.75

Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC

Type CP-S, CP-C & CP-A Switch mode

Control module CP-A CM

Power supply CP-E 24/2.5

Insulation monitoring relays CM-IWN.4/5/6 For unearthed AC, DC and mixed AC/DC systems up to U n = 400 V AC and 600 V DC

Power supply CP-E 24/2.5

Power supply CP-E 24/20.0

Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC

Power supply CP-D 24/1.3

Power supply CP-E 48/5.0 Primary switch mode power supply Data sheet

Power supply CP-E 12/10.0 Primary switch mode power supply Data sheet

ABB ABB 59 2CDC110004C0205. Measuring and monitoring relays. CM and C5xx range. Content

Electronic timer CT-SDE

Insulation monitoring relay CM-IWS.1 For unearthed AC, DC and mixed AC/DC systems up to U n = 250 V AC and 300 V DC

Insulation monitoring relay CM-IWS.2 For unearthed AC systems up to U n = 400 V AC

Electronic timer CT-AHE OFF-delayed with 1 c/o (SPDT) contact

Analog signal converters CC range

Electronic timer CT-AWE Impulse-OFF with auxiliary voltage, 1 c/o (SPDT) contact

Thermistor motor protection relays

Insulation monitoring relay CM-IWN.1 For unearthed AC, DC and mixed AC/DC systems up to U n = 400 V AC and 600 V DC

Power supply CP-T 24/40.0 Primary switch mode power supply

Power supply CP-T 24/10.0 Primary switch mode power supply

Power supply CP-D 12/2.1

Analog signal converters CC-E I/I

Power supply CP-T 48/5.0 Primary switch mode power supply

Primary switch mode power supplies Product group picture

s s s 3-60 s min min 3-60 min h h 3-60 h V AC, 50/60 Hz

Power supply CP-T 24/20.0 Primary switch mode power supply

Power supply CP-T 48/20.0 Primary switch mode power supply

CP-E range Benefits and advantages

Thermistor motor protection relays

CP-T range Product group picture

Power supply CP-D 24/4.2 Primary switch mode power supply

CP-T range Benefits and advantages

V2UM230V10 Art.Nr.: V2UM230V10P Art.Nr.: Control elements. Tripping delay. Function selector. Status indication 230 V AC/DC

Electronic measuring and monitoring relays CM-range

Grid feeding monitoring relay acc. VDE AR-N 4105 CM-UFD.M21

DATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection

Signal converters Index

DATASHEET - ETR4-51-A. Delivery program. Technical data General. Timing relay, star-delta, 50 ms, 1W, 3-60s, VAC/DC

Pluggable interface relays CR-P Pcb relays

Switching power supplies CP range, Linear power supplies CP-L range. Content

V2IM10AL10 Art.Nr.: V2IM10AL10P Art.Nr.: Control element. Tripping delay. Function selector. Status indication 24...

VEO. V2PF480Y/277VS01 Art.Nr.: B TECHNICAL DATA

Transcription:

2CDC 251 052 F0t08 CM-MPS.23 2CDC 251 053 F0t08 CM-MPS.43 - relay status, timing - fault message - fault message Adjustment of the tripping delay t V Adjustment of the threshold value for overvoltage 6 Adjustment of the threshold value for undervoltage 7 Adjustment of the threshold value for phase unbalance 8 Function selection (see DIP switch functions) / Marker label Features Monitoring of three-phase mains for phase sequence (can be switched off), phase failure, over- and undervoltage as well as phase unbalance Automatic phase sequence correction configurable Interrupted neutral monitoring possible with CM-MPS.23 CM-MPS.23 can also be used to monitor single-phase mains Can be used for mains with a frequency of 45 to 440 Hz Threshold values for phase unbalance, over- and undervoltage are adjustable as absolute values Tripping delay can be adjusted or switched off by means of a logarithmic scale ON-delayed or OFF-delayed tripping delay selectable Powered by the measuring circuit True RMS measuring principle 1x2 or 2x1 c/o (SPDT) contact configurable 3 LEDs for status indication Approvals A C D K E Marks a b Order data UL 508, CAN/CSA C22.2 No.14 GL GOST CB scheme CCC CE C-Tick Type Rated control supply voltage = measuring voltage Interrupted neutral monitoring Order code CM-MPS.23 3x180-280 V AC yes 1SVR 630 885 R4300 CM-MPS.43 3x300-500 V AC no 1SVR 630 884 R4300 Order data - Accessories Type Description Order code ADP.01 Adapter for screw mounting 1SVR 430 029 R0100 MAR.02 Marker label for devices with DIP switch 1SVR 430 043 R0000 COV.01 Sealable transparent cover 1SVR 430 005 R0100 Application The CM-MPS.x3 are multifunctional monitoring relays for three-phase mains. They monitor the phase parameters phase sequence, phase failure, over- and undervoltage and phase unbalance. CM-MPS.23 also monitors the neutral for interruption. The threshold values for over- and undervoltage and phase unbalance are adjustable. The devices can be used for mains with a frequency of 45-440 Hz. CM-MPS.23 is also suitable for monitoring single-phase mains. For this, all three external conductors (L1, L2, L3) have to be jumpered and connected as one single conductor. Phase sequence monitoring has to be deactivated and the threshold value for phase unbalance has to be set to the maximum (25 %). ABB

Operating mode Configuration of the devices is made by means of setting elements accessible on the front of the unit and signalling is made by means of front-face LEDs. Adjustment potentiometer Threshold values By means of three separate potentiometers with direct reading scales, the threshold values for over- and undervoltage as well as for phase unbalance can be adjusted within the measuring range. Measuring range for overvoltage Measuring range for undervoltage Measuring range for phase unbalance CM-MPS.23 3x240-280 V AC 3x180-220 V AC 2-25 % of average CM-MPS.43 3x420-400 V AC 3x300-380 V AC of phase voltages Tripping delay t V The tripping delay t V can be adjusted within a range of 0.1-30 s by means of a potentiometer with logaritmic scale. By turning to the leftop, the tripping delay can be switched off. DIP switches Position 4 3 2 1 ON OFF 2CDC 252 041 F0b08 ON = ON-delayed A In case of a fault, the de-energizing of the output relays and the respective fault message are suppressed for the adjusted tripping delay t V. DIP switch 1 = Timing function OFF = OFF-delayed B In case of a fault, the output relays de-energize instantaneously and a fault message is displayed and stored for the length of the adjusted tripping delay t V. Thereby, also momentary undervoltage conditions are recognized. ON = Phase sequence monitoring deactivated l Phase sequence errors will not be recognized. DIP switch 2 = Phase sequence monitoring OFF = Phase sequence monitoring activated k The output relays de-energize as soon as a phase sequence error occurs. The output relays re-energize automatically as soon as the phase sequence is correct again. 2 ABB

ON = 2x1 c/o (SPDT) contact i DIP switch 3 = Operating principle of the output relays Depending on the configuration of automatic phase sequence correction and on the fault type, the output relays R1 (/18) and R2 (/28) react differently, if operating principle 2x1 c/o (SPDT) contact is selected. Auto. phase sequence correction deactivated n: Overvoltage: only 1st c/o (SPDT) contact R1 (/18) switches Undervoltage: only 2nd c/o (SPDT) contact R2 (/28) switches Phase unbalance, phase sequence, phase failure, interrupted neutral: both output relays R1 (/18) and R2 (/28) react synchronously Auto. phase sequence correction activated m: Overvoltage, undervoltage, phase unbalance, phase failure, interrupted neutral: only 1st c/o (SPDT) contact R1 (/18) switches Phase sequence: only 2nd c/o (SPDT) contact R2 (/28) switches Operating principle 2x1 c/o (SPDT) contact is mandatory if automatic phase sequence correction is activated. OFF = 1x2 c/o (SPDT) contacts j If operating principle 1x2 c/o (SPDT) contacts is selected, both output relays R1 (/18) and R2 (/28) reacynchronously, independent of the fault type. ON = Phase sequence correction activated m DIP switch 4 = Automatic phase sequence correction In conjunction with a reversing contactor combination, it is ensured that the correct phase sequence is applied to the input terminals of the load. OFF = Phase sequence correction deactivated n No automatic phase sequence correction in case of phase sequence error. LEDs Function Control supply voltage applied, output relay energized R/T: yellow LED F1: red LED F2: red LED V - - Tripping delay t V active W - - Phase failure - V W Phase sequence - W alternating Overvoltage - V - Undervoltage - - V Phase unbalance - V V Interruption of the neutral - V W Adjustment error 1) W W W 1) Possible misadjustments of the front-face operating controls: Overlapping of the threshold values: An overlapping of the threshold values is given, if the threshold value for overvoltage is set to a smaller value than the threshold value for undervoltage. DIP switch 3 = OFF and DIP switch 4 = ON: Automatic phase sequence correction is activated and selected operating mode is 1x2 c/o (SPDT) contacts DIP switch 2 and 4 = ON: Phase sequence detection is deactivated and the automatic phase sequence correction is actived ABB 3

Function descriptions/diagrams Function diagram legend G Control supply voltage not applied / Output contact open / LED off B Control supply voltage applied / Output contact closed / LED glowing Interrupted neutral monitoring The interruption of the neutral in the main to be monitored is detected by means of phase unbalance evaluation. If the star point is displaced by asymmetrical load in the three-phase main, an interrupted neutral will be detected. Determined by the system, in case of unloaded neutral, i.e. symmetrical load between all three phases, it may happen that an interruption of the neutral will not be detected. Phase sequence and phase failure monitoring Applying control supply voltage begins the fixed start-up delay t S. When t S is complete and all phases are present with correct voltage, the output relays energize and the yellow LED R/T glows. Phase sequence monitoring If phase sequence monitoring is activated, the output relays de-energize as soon as a phase sequence error occurs. The fault is displayed by alternated flashing of the LEDs F1 and F2. The output relays reenergize automatically as soon as the phase sequence is correct again. Phase failure monitoring The output relays de-energize instantaneous if a phase failure occurs. The fault is indicated by lightning of LED F1 and flashing of LED F2. The output relays re-energize automatically as soon as the voltage returns to the tolerance range. L1, L3, L2 L1, L2 L1 = start-up delay fixed 200 ms L3 L2, L3 2CDC 252 094 F0207 4 ABB

Over- and undervoltage monitoring 1x2 c/o (SPDT) contacts j Applying control supply voltage begins the fixed start-up delay t S. When t S is complete and all phases are present with correct voltage and with correct phase sequence, the output relays energize and the yellow LED R/T glows. Type of tripping delay = ON-delay A If the voltage to be monitored exceeds or falls below the set threshold value, the output relays de-energize after the set tripping delay t V is complete. The LED R/T flashes during timing and turns off as soon as the output relays de-energize. The output relays re-energize automatically as soon as the voltage returns to the tolerance range, taking into account a fixed hysteresis of 5 %. The LED R/T glows. > U > U - 5 % < U + 5 % < U ts tv <tv tv = start-up delay fixed 200 ms t v = ajdustable tripping delay 2CDC 252 090 F0207 Type of tripping delay = OFF-delay B If the voltage to be monitored exceeds or falls below the set threshold value, the output relays de-energize instantaneously and the LED R/T turns off. As soon as the voltage returns to the tolerance range, taking into account a fixed hysteresis of 5 %, the output relays re-energize automatically after the set tripping delay t V is complete. The LED R/T flashes during timing and turns steady when timing is complete. > U > U - 5 % < U + 5 % < U ts tv <tv <tv 2CDC 252 091 F0207 = start-up delay fixed 200 ms t v = ajdustable tripping delay ABB 5

Over- and undervoltage monitoring 2x1 c/o (SPDT) contact i Applying control supply voltage begins the fixed start-up delay t S. When t S is complete and all phases are present with correct voltage and with correct phase sequence, the output relays energize. The yellow LED R/T glows as long as at least one output relay is energized. Type of tripping delay = ON-delay A If the voltage to be monitored exceeds or falls below the set threshold value, output relay R1 (overvoltage) or output relay R2 (undervoltage) de-energizes after the set tripping delay t V is complete. The LED R/T flashes during timing. The corresponding output relay re-energizes automatically as soon as the voltage returns to the tolerance range, taking into account a fixed hysteresis of 5 %. > U > U - 5 % < U + 5 % < U ts tv <tv tv = start-up delay fixed 200 ms t v = ajdustable tripping delay 2CDC 252 006 F0207 Type of tripping delay = OFF-delay B If the voltage to be monitored exceeds or falls below the set threshold value, output relay R1 (overvoltage) or output relay R2 (undervoltage) de-energizes instantaneously. As soon as the voltage returns to the tolerance range, taking into account a fixed hysteresis of 5 %, the corresponding output relay re-energizes automatically after the set tripping delay t V is complete. The LED R/T flashes during timing. > U > U - 5 % < U + 5 % < U ts tv <tv <tv 2CDC 252 007 F0207 = start-up delay fixed 200 ms t v = ajdustable tripping delay 6 ABB

Phase unbalance monitoring Applying control supply voltage begins the fixed start-up delay t S. When t S is complete and all phases are present with correct voltage and with correct phase sequence, the output relays energize and the yellow LED R/T glows. Type of tripping delay = ON-delay A If the voltage to be monitored exceeds or falls below the set phase unbalance threshold value, the output relays de-energize after the set tripping delay t V is complete. The LED R/T flashes during timing and turns off as soon as the output relays de-energize. The output relays re-energize automatically as soon as the voltage returns to the tolerance range, taking into account a fixed hysteresis of 20 %. The LED R/T glows. Unbalance Unbalance - Hysteresis Unbalance + Hysteresis Unbalance L3 L1, L2 ts tv <tv tv = start-up delay fixed 200 ms t v = ajdustable tripping delay 2CDC 252 092 F0207 Type of tripping delay = OFF-delay B If the voltage to be monitored exceeds or falls below the set phase unbalance threshold value, the output relays de-energize instantaneously and the LED R/T turns off. As soon as the voltage returns to the tolerance range, taking into account a fixed hysteresis of 20 %, the output relays re-energize automatically after the set tripping delay t V is complete. The LED R/T flashes during timing and turns steady when timing is complete. Unbalance Unbalance - Hysteresis Unbalance + Hysteresis Unbalance ts L3 L1, L2 tv <tv <tv 2CDC 252 093 F0207 = start-up delay fixed 200 ms t v = ajdustable tripping delay ABB

Automatic phase sequence correction This function can be selected only if phase sequence monitoring is activated k (DIP switch 3 = ON) and operating mode 2x1 c/o (SPDT) contact j is selected (DIP switch 2 = OFF). Applying control supply voltage begins the fixed start-up delay t S1. When t S1 is complete and all phases are present with correct voltage, output relay R1 energizes. Output relay R2 energizes when the fixed start-up delay t S2 is complete and all phases are present with correct phase sequence. Output relay R2 remains de-energized if the phase sequence is incorrect. If the voltage to be monitored exceeds or falls below the set threshold values for phase unbalance, overor undervoltage or if a phase failure occurs, output relay R1 de-energizes and the LEDs F1 and F2 indicate the fault. Output relay R2 is responsive only to a false phase sequence. In conjunction with a reversing contactor combination, this enables an automatic correction of the rotation direction. See circuit diagrams. L1, L2 L1, L3, L2 t L3 t S1 S1 t S2 t S1 = start-up delay of R1 fixed 250 ms t S2 = start-up delay of R2 fixed 200 ms t S2 2CDC 252 085 F0207 L1 L2 L3 2CDC 252 086 F0b07 L1 L2 L3 1 3 5 -F1 2 4 6 2CDC 252 087 F0b07 K1 15 18 -K2 1 2 3 4 5 6 -K3 1 2 3 4 5 6 K1 25 28 K1 25 26 15 K1 16 -F2 1 3 5 2 4 6 97 98 95 96 N L1 L2 L3 K1 N K2 A1 A2 K3 A1 A2 H1 W1 V1 U1 -M1 M 3 ~ Control circuit diagram (K1 = CM-MPS.x3) Power circuit diagram 8 ABB

Connection diagrams L1 N L2 L1 L2 L3 15 L3 25 N 16 18 26 28 26 25 28 16 15 18 CM-MPS.23 2CDC 252 036 F0b08, N Control supply voltage = measuring voltage /18 Output contacts - /28 closed-circuit principle L1 L2 L3 L1 L2 L3 15 25 16 18 26 28 26 25 28 16 15 18 CM-MPS.43 2CDC 252 037 F0b08 Control supply voltage = measuring voltage /18 Output contacts - /28 closed-circuit principle ABB

Data at T a = 25 C and rated values, if nothing else indicated Type CM-MPS.23 CM-MPS.43 Input circuit = Measuring circuit, N Rated control supply voltage U S = measuring voltage 3x180-280 V AC 3x300-500 V AC Rated control supply voltage U S tolerance -15...+10 % Rated frequency 50/60/400 Hz Frequency range 45-440 Hz Typical current / power consumption 5 ma / 4 VA (230 V AC) 5 ma / 4 VA (400 V AC) Measuring circuit, N Monitoring functions Phase failure Phase sequence can be switched off can be switched off Automatic phase sequence correction configurable configurable Over-/undervoltage Phase unbalance Interrupted neutral - Measuring range Overvoltage 3x240-280 V AC 3x420-500 V AC Undervoltage 3x180-220 V AC 3x300-380 V AC Phase unbalance 2-25 % of average of phase voltages Thresholds Overvoltage adjustable within measuring range Undervoltage adjustable within measuring range Phase unbalance (switch-off value) adjustable within measuring range Hysteresis related to Over-/undervoltage fixed 5 % the threshold value Phase unbalance fixed 20 % Rated frequency of the measuring signal 50/60/400 Hz Frequency range of the measuring signal 45-440 Hz Maximum measuring cycle time 100 ms Measuring error within the rated control supply voltage tolerance 0.5 % Measuring error within the temperature range 0.06 % / C Measuring method True RMS Timing circuit Start-up delay t S and t S2 fixed 200 ms Start-up delay t S1 fixed 250 ms Tripping delay t V ON- or OFF-delay 0; 0.1-30 s adjustable Repeat accuracy (constant parameters) < w0.2 % Timing error within the rated control supply voltage tolerance 0.5 % Timing error within the temperature range 0.06 % / C Indication of operational states 1 yellow LED, 2 red LEDs Details see operating mode and function description/diagrams Output circuits /18, /28 Kind of output 2x1 or 1x2 c/o (SPDT) contacts configurable (Relays) Operating principle 1) closed-circuit principle Contact material AgNi alloy, Cd free Rated voltage (VDE 0110, IEC 60947-1) 250 V Minimum switching power 24 V / 10 ma Maximum switching voltage see load limit curve Rated operational current AC12 (resistive) 230 V 4 A (IEC/EN 60947-5-1) AC15 (inductive) 230 V 3 A DC12 (resistive) 24 V 4 A DC13 (inductive) 24 V 2 A AC rating (UL 508) Utilization category (Control Circuit Rating Code) B 300 max. rated operational voltage 300 V AC max. continuous thermal current at B 300 5 A max. making/breaking apparent power at B 300 3600/360 VA 10 ABB

Data at T a = 25 C and rated values, if nothing else indicated Type CM-MPS.23 CM-MPS.43 Mechanical lifetime 30 x 10 6 switching cycles Electrical lifetime (AC12, 230 V, 4 A) 0,1 x 10 6 switching cycles Short-circuit proof, n/c contact 6 A fast-acting maximum fuse rating n/o contact 10 A fast-acting General data Duty time 100 % Dimensions (W x H x D) 22.5 x 78 x 100 mm (0.89 x 3.07 x 3.94 inch) Weight 0.14 kg (0.31 lb) 0.13 kg (0.29 lb) Mounting DIN rail (EN 60715), snap-on mounting without any tool Mounting position any Minimum distance to other units not necessary Degree of protection enclosure / terminals IP50 / IP20 Electrical connection Wire size fine-strand with(out) wire end ferrule 2 x 0.75-2.5 mm² (2 x 18-14 AWG) rigid 2 x 0.5-4 mm² (2 x 20-12 AWG) Stripping length 7 mm (0.28 inch) Tightening torque 0.6-0.8 Nm Environmental data Ambient temperature ranges operation / storage -25...+60 C / -40...+85 C Damp heat (IEC 60068-2-30) 55 C, 6 cycles Climatic category 3K3 Vibration (sinusoidal) (IEC/EN 60255-21-1) Class 2 Shock (IEC/EN 60255-21-2) Class 2 Isolation data Rated insulation input circuit / output circuit 600 V voltage U i output circuit 1 / output circuit 2 300 V Rated impulse withstand voltage U imp (VDE 0110, IEC/EN 60664) Test voltage (type test) between input circuit 6 kv; 1.2/50 µs output circuit 4 kv; 1.2/50 µs isolated output circuits input circuit and isolated output circuits 2.5 kv, 50 Hz, 1 s 2.5 kv, 50 Hz, 1 s Basis isolation input circuit / output circuit 600 V Protective separation (VDE 0160 part 101 and 101/A, IEC/EN 61140) input circuit / output circuit Pollution degree (VDE 0110, IEC/EN 60664, UL 508) 3 Overvoltage category (VDE 0110, IEC 60664, UL 508) III Standards Productandard IEC/EN 60255-6, EN 50178 Low Voltage Directive 2006/95/EC EMC directive 2004/108/EC RoHS directive 2002/95/EC Electromagnetic compatibility Interference immunity EN 61000-6-1, EN 61000-6-2 electrostatic discharge (ESD) IEC/EN 61000-4-2 Level 3 (6 kv / 8 kv) electromagnetic field (HF radiation resistance) IEC/EN 61000-4-3 Level 3 (10 V/m) fast transients (Burst) IEC/EN 61000-4-4 Level 3 (2 kv / 2 khz) powerful impulses (Surge) IEC/EN 61000-4-5 Level 4 (2 kv L-N) Level 4 (2 kv L-L) HF line emission IEC/EN 61000-4-6 Level 3 (10 V) Resistance to harmonics EN 61000-4-13 Class 3 Interference emission EN 61000-6-3, EN 61000-6-4 electromagn. field (HF radiation resistance) IEC/CISPR 22, EN 50022 Class B HF line emission IEC/CISPR 22, EN 50022 Class B 1) Closed-circuit principle: Output relay(s) de-energize(s) if measured value exceeds or falls below the adjusted threshold value - ABB 11

Technical diagrams Load limit curves AC load (resistive) DC load (resistive) V V 300 200 100 80 60 50 40 30 20 2CDC 252 194 F0205 V V 300 200 100 80 60 50 40 30 20 2CDC 252 193 F0205 10 0.1 0.2 0.5 1 2 4 6 10 I A 10 0.1 0.2 0.5 1 2 4 6 10 I A Derating factor F at inductive AC load F 1.0 0.9 0.8 0.7 0.6 0.5 2CDC 252 192 F0205 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 cos ϕ Contact lifetime Switching cycles 250 V resistive load 2CDC 252 148 F0206 Switching current [A] 12 ABB

Dimensions in mm 2CDC 252 031 F0b03 Dimensions - Accessories in mm 4,5.177 62,5 2.46 60 2.36 11,5.453 10.394 22,5.886 2CDC 252 187 F0005 3A11 20.787 8.315 2CDC 252 186 F0005 ADP.01 - Adapter for screw mounting MAR.02 - Marker label 2.70 22,5.886 7.275 3,5.138 2CDC 252 185 F0005 68,5 front-to-back size 107 COV.01 - Sealable transparent cover Further documentation Document title Document type Document number Electronic Products and Relays Technical catalogue 2CDC 110 004 C020x CM-MPS.23, CM-MPS.43, CM-MPN.52, CM-MPN.62, CM-MPN.72 Instruction manual 1SVC 630 530 M0000 You can find the documentation online at www.abb.com/lowvoltage R Control Products R... ABB 13

ABB As part of the on going product improvement, ABB reserves the right to modify the characteristics of the products described in this document. The information given is noncontractual. For further details please contact (www.abb.com/contacts) the ABB company marketing these products in your country. Document number. 2CDC 112 127 D0201 (09/2008) ABB STOTZ-KONTAKT GmbH Eppelheimer Straße 82, 69123 Heidelberg, Germany Postfach 10 16 80, 69006 Heidelberg, Germany Internet http://www.abb.com/lowvoltage R Control Products You can find the address of your local sales organisation on the ABB home http://www.abb.com/contacts R Low Voltage products