Features 1. Peak wavelength at 25 o C:980 nm (typical) 2. Standard light output:200mw (CW) 3. TO-18 (ψ5.6mm) Packaged, cap window with flat Pb-free lens, monitor PD inside. Applications 1. Laser indicator 2. Laser detector 3. Night vision External dimensions(unit : mm) No.156, Gaoshih Rd., Yangmei Township, Taoyuan County 326, Taiwan (R.O.C.) TEL: 886-3-485-2687 FAX : 886-3-475-4378 E-mail: sales@uocnet.com Website:http://www.uocnet.com 1 / 5
Absolute Maximum Ratings(Tc=25 ) Parameter Symbol Rating Unit Optical Output Po 200 mw Reverse Voltage Vr 2 V Operating Temperature(Case) Top -10~+40 Storage Temperature Tstg -40~+85 Electrical and Optical Characteristics(Tc=25 ) Parameter Symbol Condition Min. Typ. Max. Unit Threshold Current Ith Po=200mW - 60 80 ma Operating Current Iop Po=200mW - 280 365 ma Operating Voltage Vop Po=200mW 1.0 1.48 2.0 Volts Slope Efficiency η Po=50-150mW 0.7 0.9 - mw/ma Monitor current Im Po=200mW - 0.4 1.0 ma Beam Divergence Parallel θ // Po=200mW - 10 - deg. (FWHM) Perpendicular θ Po=200mW - 36 - deg. Lasing Wavelength λ Po=200mW 970 980 990 nm θ // and θ are defined as the angle within which the intensity is 50% of the peak value. Quality Notice This device is still under product development, the long-term lifetime test has not been qualified yet. Typical characteristic curves Optical Output Power (mw) 250 225 200 175 150 125 100 75 50 25 0 Optical Output Power v.s. Forward Current 25 o C 40 o C 50 o C 60 o C 70 o C 85 o C 0 50 100 150 200 250 300 350 400 Forward Current (ma) 2 / 5
Forward Voltage (V) Forward Voltage v.s. Forward Current 1.8 25 o C 40 o C 50 o C 60 o C 70 o C 85 o C 1.5 1.2 0.9 0.3 0 0 50 100 150 200 250 300 350 400 Forward Current (ma) 1005 Peak Wavelength v.s. Case Temperature Peak Wavelength (nm) 1000 995 990 985 980 975 970 Relative Intensity 1.0 0.8 0.4 0.2 0.0 Po=200mW Tc=25 o C Perpendicular Far-Field Pattern Parallel -60-50 -40-30 -20-10 0 10 20 30 40 50 60 Angle (degree) 3 / 5
Monitor Current (ma) 0.50 Tc=25 o C 0.40 0.30 0.20 0.10 Monitor Current v.s. Optical Output Power 0.00 0 40 80 120 160 200 Optical Output Power (mw) Slope Efficiency (mw/ma) 1.0 0.8 0.4 0.2 0.0 Slope Efficiency v.s. Case Temperature 100 Threshold Current v.s. Case Temperature Threshold Current (ma) 10 4 / 5
Precautions QUALITY ASSURANCE After any processing of laser chip or laser diode TO-CAN (LD) by the customer, the performance, yield and reliability of the product, in which the chip or LD is applied, are subject to change due to customer s handling, assembly, testing, and processing. Because laser chip and LD are strongly affected by environmental conditions, physical stress, and chemical stresses imposed by customer that are not in Union Optronics Corp. (UOC) control and hence no guarantee on the characteristics and the reliability at all after the shipment. Also, UOC does not have any responsibility for field failures in a customer product. When attaching a heat sink to laser chip or LD, be careful not to apply excessive force to the device in the process. SAFETY PRECAUTIONS Although Union Optronics Corp. (UOC) keeps improving quality and reliability of its laser chip and laser diode TO-CAN (LD), semiconductor devices in general can malfunction or fail due to their intrinsic characteristics. Hence, it is required that the customer s products are designed with full regard to safety by incorporating the redundancy, fire prevention, error prevention so that any problems or error with UOC laser chip or LD does not cause any accidents resulting in injury, death, fire, property damage, economic damage, or environmental damage. In case customer wants to use UOC laser chip or LD in the systems requiring high safety, customer is requested to confirm safety of entire systems with customer s own testing. SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE. The information provided by Union Optronics Corp. (UOC), including but not limited to technical specifications, recommendations, and application notes relating to laser chip or laser diode TO-CAN (LD) is believed to be reliable and accurate and is subject to change without notice. UOC reserves the right to change its assembly, test, design, form, specification, control, or function without notice. 5 / 5